The aim of this study was to explore whether time to surgery affects functional outcome in displaced proximal humeral fractures A total of 250 patients presenting within three weeks of sustaining a displaced proximal humeral fracture involving the surgical neck were recruited at 32 acute NHS hospitals in the United Kingdom between September 2008 and April 2011. Of the 125 participants, 109 received surgery (fracture fixation or humeral head replacement) as per randomization. Data were included for 101 and 67 participants at six-month and five-year follow-up, respectively. Oxford Shoulder Scores (OSS) collected at six, 12, and 24 months and at three, four, and five years following randomization was plotted against time to surgery. Long-term recovery was explored by plotting six-month scores against five-year scores and agreement was illustrated with a Bland-Altman plot.Aims
Methods
We describe a five-year-old child with neurofibromatosis type I who developed a Charcot knee. Infiltration of the joint by tissue associated with the disease caused
After total knee replacement a 57-year-old woman developed increasing pain in her left calf on exercise. This was due to erosion of the popliteal artery by a spur of cement. Removal of the spur with resection and Dacron grafting of the
Patellectomy is at present the best operation for recurrent dislocation, not only because the immediate result is excellent, but because it avoids the later arthritis which must inevitably arise if a patella so
Removal of well-fixed, cementless, acetabular components during revision arthroplasty remains a challenging problem. Further
1. Two cases of arterial
Retrosternal dislocation of the clavicle is an unusual injury. Serious complications may arise from
Previous studies have evidenced cement-in-cement techniques as reliable in revision arthroplasty. Commonly, the original cement mantle is reshaped, aiding accurate placement of the new stem. Ultrasonic devices selectively remove cement, preserve host bone, and have lower cortical perforation rates than other techniques. As far as the authors are aware, the impact of ultrasonic devices on final cement-in-cement bonds has not been investigated. This study assessed the impact of cement removal using the Orthosonics System for Cemented Arthroplasty Revision (OSCAR; Orthosonics) on final cement-in-cement bonds. A total of 24 specimens were manufactured by pouring cement (Simplex P Bone Cement; Stryker) into stainless steel moulds, with a central rod polished to Stryker Exeter V40 specifications. After cement curing, the rods were removed and eight specimens were allocated to each of three internal surface preparation groups: 1) burr; 2) OSCAR; and 3) no treatment. Internal holes were recemented, and each specimen was cut into 5 mm discs. Shear testing of discs was completed by a technician blinded to the original grouping, recording ultimate shear strengths. Scanning electron microscopy (SEM) was completed, inspecting surfaces of shear-tested specimens.Objectives
Methods
Hemicircumferential division of the periosteum was performed on the upper tibia of the rabbit. Division of the medial side regularly caused a valgus angulation, but other injuries about the upper tibia had no effect. The cause of deformity after periosteal
A case of posterior fracture-dislocation of the hip complicated by displacement of a segment of the acetabular rim into the joint at the time of closed reduction is reported. In treatment, it is stressed that the posterior approach to the hip should be used to minimise further
Closed tenotomy was used to treat triggering of the fingers and thumb in 54 patients. In 56 digits the method was successful; in seven it was a simple matter to proceed to open tenotomy. With experience, the closed procedure can be completed within minutes without risk of
Numerous intravascular bony spicules were found at necropsy in both lungs of an 84-year-old patient who had undergone total hip replacements three and 10 months before death. It is suggested that acetabular grindings enter the
This aim of this study was to assess the feasibility of designing and introducing generic 3D-printed instrumentation for routine use in total knee arthroplasty. Instruments were designed to take advantage of 3D-printing technology, particularly ensuring that all parts were pre-assembled, to theoretically reduce the time and skill required during surgery. Concerning functionality, ranges of resection angle and distance were restricted within a safe zone, while accommodating either mechanical or anatomical alignment goals. To identify the most suitable biocompatible materials, typical instrument shapes and mating parts, such as dovetails and screws, were designed and produced.Aims
Materials and Methods
We present the case of a 63-year-old woman who sustained an acrylic cement burn of the sciatic nerve at hip replacement. She was treated by resection of the
The aim of this study was to evaluate the differences in revision and complication rates, functional outcomes, and radiological outcomes between cemented and press-fit humeral stems in primary anatomical total shoulder arthroplasty (TSA). A comprehensive systematic review and meta-analysis was conducted searching for studies that included patients who underwent primary anatomical TSA for primary osteoarthritis or rheumatoid arthritis.Aims
Materials and Methods
A case of traumatic aneurysm of the peroneal artery at the level of its perforating branch is described. The intimate and variable relationship of this vessel to the flexor hallucis longus muscle and the tethering effect of its perforating branch predispose to its
1. The clinical and post-mortem findings are described of a patient who sustained a hyperextension injury of the neck with paraplegia. 2. There was no radiological evidence of fracture: osteoarthritis of the spine was present. 3. Evidence is presented that the cord was
1. A modified technique of tendon transference for irreparable