Advertisement for orthosearch.org.uk
Results 701 - 720 of 1796
Results per page:
Bone & Joint 360
Vol. 8, Issue 3 | Pages 31 - 33
1 Jun 2019


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 24 - 33
1 Jan 2019
Kayani B Konan S Tahmassebi J Rowan FE Haddad FS

Aims

The objectives of this study were to compare postoperative pain, analgesia requirements, inpatient functional rehabilitation, time to hospital discharge, and complications in patients undergoing conventional jig-based unicompartmental knee arthroplasty (UKA) versus robotic-arm assisted UKA.

Patients and Methods

This prospective cohort study included 146 patients with symptomatic medial compartment knee osteoarthritis undergoing primary UKA performed by a single surgeon. This included 73 consecutive patients undergoing conventional jig-based mobile bearing UKA, followed by 73 consecutive patients receiving robotic-arm assisted fixed bearing UKA. All surgical procedures were performed using the standard medial parapatellar approach for UKA, and all patients underwent the same postoperative rehabilitation programme. Postoperative pain scores on the numerical rating scale and opiate analgesia consumption were recorded until discharge. Time to attainment of predefined functional rehabilitation outcomes, hospital discharge, and postoperative complications were recorded by independent observers.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 880 - 888
1 Jul 2019
Wei R Guo W Yang R Tang X Yang Y Ji T Liang H

Aims

The aim of this study was to describe the use of 3D-printed sacral endoprostheses to reconstruct the pelvic ring and re-establish spinopelvic stability after total en bloc sacrectomy (TES) and to review its outcome.

Patients and Methods

We retrospectively reviewed 32 patients who underwent TES in our hospital between January 2015 and December 2017. We divided the patients into three groups on the basis of the method of reconstruction: an endoprosthesis group (n = 10); a combined reconstruction group (n = 14), who underwent non-endoprosthetic combined reconstruction, including anterior spinal column fixation; and a spinopelvic fixation (SPF) group (n = 8), who underwent only SPF. Spinopelvic stability, implant survival (IS), intraoperative haemorrhage rate, and perioperative complication rate in the endoprosthesis group were documented and compared with those of other two groups.


Bone & Joint 360
Vol. 8, Issue 1 | Pages 40 - 42
1 Feb 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 3 | Pages 469 - 471
1 Aug 1965
Nickel VL Waring W

Future devices will be more reliable, although more versatile and complex. They will require less attention and maintenance, but more skill when maintenance or repair is necessary. They will require less training of the patient before he can use them successfully and will be more immediately responsive to his wishes, giving smooth, integrated movements, varying with the intensity and direction of his effort


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 448 - 449
1 May 1993
Noordeen M Lavy C Briggs T Roos M

Screw devices used to treat fractures of the femoral neck are usually positioned under image-intensifier control, using anteroposterior and lateral views. The volume projected by these views is over 27% larger than the femoral head; the tips of screws so placed may be outside the femoral head. This can be avoided by placement within the central two-thirds of the head: we have designed a template which can confirm safe placement


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 579 - 582
1 May 2002
Hallam PJB Fazal MA Ashwood N Ware HE Glasgow MMS Powell JM

Fractures of the anterior intercondylar eminence in children are relatively uncommon. There is considerable debate as to the best treatment of displaced fractures, but most methods described in the literature involve an open procedure combined with some form of fixation. Using human anatomical dissections, we have shown that the transverse meniscal ligament can become incarcerated within the fracture and act as a block to reduction. We describe an arthroscopic technique which requires no fixation device and report the results of its use in eight displaced fractures. This method gives reliable results and offers the advantage of less potential morbidity


Bone & Joint 360
Vol. 8, Issue 3 | Pages 37 - 40
1 Jun 2019


Bone & Joint 360
Vol. 8, Issue 1 | Pages 25 - 27
1 Feb 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 74 - 77
1 Jan 1992
Butler-Manuel P James S Shepperd J

A new method to reconstruct major acetabular floor defects is described. It relies on the placement of special nails into each of the three bones of the hemipelvis. Curved lugs attached to the nails are coalesced using bone cement forming a platform onto which a standard acetabular prosthesis is located. Forty-seven cases are reported with a mean follow-up of 4.4 years (1 to 8). No loosening of an acetabular cup or migration of the device has occurred


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 83 - 91
1 Jan 2019
Whitehouse MR Berstock JR Kelly MB Gregson CL Judge A Sayers A Chesser TJ

Aims

The aim of this study was to investigate the association between the type of operation used to treat a trochanteric fracture of the hip and 30-day mortality.

Patients and Methods

Data on 82 990 patients from the National Hip Fracture Database were analyzed using generalized linear models with incremental case-mix adjustment for patient, non-surgical and surgical characteristics, and socioeconomic factors.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 388 - 389
1 May 1997
Basu P Packer CJ Himstedt J

We have assessed the effect of a variety of implants commonly used in fracture fixation and joint replacement on the activation of metal detectors at airport security gates. A volunteer with metal implants strapped on and patients with implants in situ walked through the device. Implants used in fixation do not activate it, except for Richards cannulated screws. An Austin-Moore prosthesis does set off the detector, but a single joint replacement does not. Three or four joint replacements activate the alarm and patients with these implants should be warned of this possibility


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 19 - 22
1 Jan 2002
Kosygan KP Mohan R Newman RJ

We performed a randomised, prospective trial in 111 patients with intertrochanteric fractures of the hip comparing the use of the Gotfried percutaneous compression plate (PCCP) with that of the classic hip screw (CHS). Blood loss and transfusion requirement were less in the PCCP group but the operating time was significantly longer. The complication rate after operation was similar in both groups, and at a minimum follow-up of six months there was no difference in the rates of fracture healing or implant failure. The PCCP gives results which are similar to those obtained with a conventional device. Its suggested advantages seem to be theoretical rather than practical and, being a fixed-angle implant, it is not universally applicable


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 204 - 210
1 Mar 1985
McMaster M

Fourteen patients with ankylosing spondylitis had an extension osteotomy for severe flexion deformity of the spine. The Smith-Petersen technique was modified by using a compression device which allows a slow, finely controlled closure of the osteotomy, and provides rigid internal fixation. There were no serious neurological complications. All the patients were able to see straight ahead after operation, and all had solid fusion at nine months, having maintained good correction


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 199 - 202
1 Mar 1999
Luger EJ Nissan M Karpf A Steinberg EL Dekel S

The longitudinal arch between the heel and the forefoot and the transverse arch between the first and fifth metatarsal heads, absorb shock, energy and force. A device to measure plantar pressure was used in 66 normal healthy subjects and in 294 patients with various types of foot disorder. Only 22 (3%) of a total of 720 feet, had a dynamic metatarsal arch during the stance phase of walking, and all had known abnormality. Our findings show that there is no distal transverse metatarsal arch during the stance phase. This is important for the classification and description of disorders of the foot


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 351 - 354
1 May 1993
Gross M

There is an urgent need for the staged, controlled, introduction of new technology and new procedures to surgery. A classification system in four stages is proposed, which would allow for prospective assessment of new devices or methods before they are released for use by the surgical community. The proposal recognises the unique nature of a surgical operation and its learning curve. The issues of randomisation and of informed consent are discussed, and are shown not to be barriers to clinical trials, but necessary adjuncts to orderly testing. The importance of continued surveillance of innovations is emphasised


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 4 | Pages 937 - 943
1 Nov 1962
Klenerman L

The history of surgery is to a large extent written around the record of its technical advances. A pneumatic tourniquet is a humble instrument, when compared with many of the more complicated mechanical devices in the modern operation theatre. Nevertheless, it has played a significant role in making possible the precise operations of present-day orthopaedics. Simple tool though the tourniquet may be, its application carries many potential dangers, and it should only he entrusted to skilled hands


The Journal of Bone & Joint Surgery British Volume
Vol. 40-B, Issue 4 | Pages 694 - 700
1 Nov 1958
Bremner RA Graham WD

1. The results of treatment of 100 consecutive patients with pertrochanteric and basal fractures of the femur treated by early operative fixation with a McKee two-piece nail and plate are reviewed. 2. Technical failures are analysed and discussed. 3. The pattern of mortality is discussed and contrasted with that in a comparable series of patients treated conservatively. 4. It is concluded that early operative fixation is the method of choice in the management of these fractures, and that the McKee pin and plate is a satisfactory and reliable device for securing internal fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 1003 - 1007
1 Nov 1997
Oka M Chang Y Nakamura T Ushio K Toguchida J Gu H

We have studied damage to the tibial articular surface after replacement of the femoral surface in dogs. We inserted pairs of implants made of alumina, titanium and polyvinyl alcohol (PVA) hydrogel on titanium fibre mesh into the femoral condyles. The two hard materials caused marked pathological changes in the articular cartilage and menisci, but the hydrogel composite replacement caused minimal damage. The composite osteochondral device became rapidly attached to host bone by ingrowth into the supporting mesh. We discuss the clinical implications of the possible use of this material in articular resurfacing and joint replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 217 - 219
1 Mar 1990
Emery R Todd R Dunn D

We report the complications of prophylactic pinning of slipped upper femoral epiphysis with Crawford Adams pins in 95 cases. Complications of pin placement were seen in 13.7%. Although seven hips had penetration of the joint, there were no cases of chondrolysis or avascular necrosis. Excavation of the lateral femoral cortex was required at pin removal in 12.5% of cases. Analysis of the growth around pins allowed recommendations to be made regarding pin protrusion. The use of improved fixation devices may reduce the need for multiple pins