Advertisement for orthosearch.org.uk
Results 721 - 740 of 1189
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 627 - 634
1 Jun 2019
King JJ Dalton SS Gulotta LV Wright TW Schoch BS

Aims

Acromial fractures following reverse shoulder arthroplasty (RSA) have a wide range of incidences in reported case series. This study evaluates their incidence following RSA by systematically reviewing the current literature.

Materials and Methods

A systematic review using the search terms “reverse shoulder”, “reverse total shoulder”, or “inverted shoulder” was performed using PubMed, Web of Science, and Cochrane databases between 1 January 2010 and 31 March 2018. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used. Studies were included if they reported on RSA outcomes and the incidence rate of acromial and/or scapular spine fractures. The rate of these fractures was evaluated for primary RSA, revision RSA, RSA indications, and RSA implant design.


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 4 | Pages 488 - 491
1 Nov 1976
Menelaus M

Two children with radial club hand and absence of the biceps muscle were treated by centralisation of the ulna into the carpus and triceps transfer. The two operations were performed only a short time apart so that the period between the procedures could be used to stretch the triceps and to enable the children to adapt to an altered position of the wrist and to mobility of the elbow at one step and following a single period of plaster immobilisation. It is very likely that function is better than it would have been had the condition remained untreated. Before operation the children had only a crude hook function of the hand against the forearm and could not bring the hand to the mouth. Even if function is not much improved, the improvement in appearance is considerable and is by itself sufficient to justify the procedures


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 4 | Pages 430 - 436
1 Nov 1975
Jakob R Fowles JV Rang M Kassab MT

From an anatomical study and clinical review of fractures of the lateral humeral condyle in children, the following conclusions are drawn. The mechanism of injury is a violent varus force with the elbow in extension, the condyle being avulsed. by the lateral ligament and the extensor muscles. If the fracture is incomplete, with an intact hinge of pre-osseous cartilage medially, the fragment will not be displaced. If the fracture is complete the fragment may be displaced, and open reduction with internal fixation is mandatory. The results of open reduction more than three weeks after the fracture are no better than those of no treatment at all, and may kill the lateral condylar fragment by damaging its blood supply. The major problem of a neglected fracture is tardy ulnar nerve palsy; to avoid this, immediate anterior transposition of the nerve is recommended, operation for the fracture itself being of no benefit


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 293 - 295
1 Mar 1995
Le Huec J Schaeverbeke T Chauveaux D Rivel J Dehais J Le Rebeller A

We report two cases of epicondylitis of the elbow occurring after treatment with fluoroquinolone antibiotics. Both patients had intense pain which appeared very shortly after the first dose of the drug and was not relieved by conservative treatment. Ultrasonography revealed extensive inflammatory lesions with pseudonecrotic areas. MRI confirmed the lesions and also showed a subclinical abnormality of the adjoining tendons. The persistent nature of the pain was the indication for surgical release of the extensor mechanism. After operation pain disappeared completely and the patients were able to return to their normal activities. Lesions of the tendo Achillis are a well-known side-effect of treatment with fluoroquinolone. Our two cases show that such lesions may occur elsewhere. They also indicate the need for caution when prescribing these antibiotics to patients at risk of tendon lesions, such as top-level sportsmen or patients on dialysis or steroid treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 80 - 84
1 Jan 1999
Trail IA Nuttall D Stanley JK

We undertook a radiological analysis of 186 standard Souter implants to determine survivorship and to analyse the pattern of failure in those needing revision. The implants had been inserted as a primary procedure in patients with rheumatoid arthritis of the elbow at our hospital over the last 12 years. Taking revision as an endpoint, the survivorship after 12 years was 87%. If, however, revision and loosening, defined as the Hindex value equivalent to demarcation of 1 mm around the whole implant, are also included, the survivorship falls to 80%. Of the 24 implants revised, 18 (75%) were for problems with the humeral component, three (12.5%) with the ulnar component and three (12.5%) for instability. Loosening of the humeral component occurred when the implant extended into the humerus, with the tip moving anteriorly on to the anterior humeral cortex. Our study indicates that loosening can be predicted by the rate of change in this angle of extension of the prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 3 | Pages 367 - 372
1 May 1985
Fyfe I Mossad M Holdsworth B

This study was designed to compare the rigidity of the more commonly used techniques of internal fixation of fractures of the olecranon. Cadaveric elbow joints were mounted in a jig and controlled osteotomies performed to simulate transverse, oblique or comminuted fractures. Five techniques of internal fixation were tested by measuring movement at the fracture site after applying a bending moment to the ulna. At transverse osteotomies tension-band wiring with two tightening knots allowed least movement even at high loads. Intramedullary cancellous screw fixation gave erratic results; adding a tension band with a single know was little better. In oblique osteotomies, no statistically significant difference was shown between one-third tubular plate fixation and double-knot wiring. Comminuted osteotomies were held most rigidly by contoured one-third tubular plate fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 1024 - 1030
1 Nov 1998
Waikakul S Vanadurongwan V Unnanuntana A

We performed a prospective study in 186 patients with a minimum follow-up of two years in order to attempt to predict successful major re-implantation of the upper limb. There were 137 men and 49 women with 24 amputations of the palm, 75 of the wrist, 50 of the forearm, 9 disarticulations through the elbow, and 28 amputations through the upper arm. The degree of injury to the amputated segment and the stump were good predictors of the rate of success and the final outcome. Adequate preservation, contraction of the muscle in the amputated part after stimulation, the level of injury and a smoking habit were fair indicators, but the serum potassium concentration in the amputated segment was the best objective predictor. When it is higher than 6.5 mmol/l 30 minutes after re-perfusion, re-implantation should be avoided. A high systemic venous serum potassium concentration was also found before clinical signs of the re-perfusion syndrome were seen


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 805 - 808
1 Aug 2001
Ikeda M Fukushima Y Kobayashi Y Oka Y

Between 1993 and 1999, we treated ten patients with comminuted fractures of the olecranon by multiple tension-band wiring and a graft from the iliac crest. Their mean age was 35 years (19 to 56). The mean follow-up was for 28.5 months (15 to 46) and the mean time to union of the fractures was four months (3 to 7). No patient reported difficulties with activities of daily living or symptoms of instability of the elbow. The mean flexion was to 135° (125 to 145) with a mean flexion contracture of 15° (10 to 30). The mean pronation was 70° (60 to 80) and mean supination 79° (70 to 90). Only three patients had mild pain and loss of strength. Five patients had excellent and five good results with a mean Broberg and Morrey index score of 94.5 points (84 to 100). Our results compare favourably with those previously reported and the technique is thought to be a practical alternative to plate fixation in fractures with extreme comminution


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1116 - 1120
1 Nov 2002
Sanchez-Sotelo J Morrey BF

Seven patients with chronic insufficiency of the triceps were treated by either a rotation flap using anconeus (4) or an allograft of tendo Achillis (3). The latter procedure was selected for patients with a large defect in whom the anconeus muscle had been devitalised. Five disruptions were in patients who had previously undergone an elbow replacement. The patients were assessed for subjective satisfaction, pain, range of movement and strength, and the results were graded using the Mayo Elbow Performance Score (MEPS). The mean follow-up was for 33 months (9 to 63). One rotation flap failed six months after operation. At the most recent follow-up, the remaining six patients had no or slight pain, restoration of a functional arc of movement and normal or slightly decreased power of extension. All six were satisfied with the outcome and were able to resume their daily activities with no limitations other than those imposed by the previous elbow replacement. The final MEPS was 100 points in five patients and 75 in one


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 244 - 249
1 Mar 1996
Judet T de Loubresse CG Piriou P Charnley G

We report our experience over seven years with a floating radial-head prosthesis for acute fractures of the radial head and the complications which may result from such injury. The prosthesis has an integrated articulation which allows change of position during movement of the elbow. We present the results in 12 patients with a minimum follow-up of two years. Five prostheses had been implanted shortly after injury with an average follow-up of 49 months and seven for the treatment of sequelae with an average follow-up of 43 months. All prostheses have performed well with an improved functional score (modified from Broberg and Morrey 1986). We have not experienced any of the complications previously reported with silicone radial-head replacement. Our initial results suggest that the prosthesis may be suitable for the early or delayed treatment of Mason type-III fractures and more complex injuries involving the radial head


Bone & Joint 360
Vol. 8, Issue 5 | Pages 33 - 35
1 Oct 2019


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1416 - 1423
1 Nov 2018
Rajan PV Qudsi RA Dyer GSM Losina E

Aims

The aim of this study was to assess the quality and scope of the current cost-effectiveness analysis (CEA) literature in the field of hand and upper limb orthopaedic surgery.

Materials and Methods

We conducted a systematic review of MEDLINE and the CEA Registry to identify CEAs that were conducted on or after 1 January 1997, that studied a procedure pertaining to the field of hand and upper extremity surgery, that were clinical studies, and that reported outcomes in terms of quality-adjusted life-years. We identified a total of 33 studies that met our inclusion criteria. The quality of these studies was assessed using the Quality of Health Economic Analysis (QHES) scale.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 627 - 635
1 Jul 1994
Papagelopoulos P Morrey B

We report the results in 24 consecutive patients treated from 1976 to 1991 for nonunion of olecranon fractures. Their mean age was 42 years, and the mean interval from fracture to treatment for nonunion was 19 months. Management was by rehabilitation and activity as tolerated for three, continued immobilisation for one, and operative treatment for 20. Operations included excision of the olecranon fragment (1), osteosynthesis (16), and joint replacement (3). Four patients also had distraction arthroplasty. At a mean follow-up of 18 months no patient had severe residual elbow pain but three had moderate and six had mild symptoms. The mean arc of motion was 98 degrees representing an average improvement of 11 degrees. Twelve patients had an excellent result, four good, six fair, and two a poor result. Union had been achieved in 15 of the 16 patients treated by osteosynthesis


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 610 - 614
1 May 2019
Aibinder WR Bartels DW Sperling JW Sanchez-Sotelo J

Aims

Shoulder arthroplasty using short humeral components is becoming increasingly popular. Some such components have been associated with relatively high rates of adverse radiological findings. The aim of this retrospective review was to evaluate the radiological humeral bone changes and mechanical failure rates with implantation of a short cementless humeral component in anatomical (TSA) and reverse shoulder arthroplasty (RSA).

Patients and Methods

A total of 100 shoulder arthroplasties (35 TSA and 65 RSA) were evaluated at a mean of 3.8 years (3 to 8.3). The mean age at the time of surgery was 68 years (31 to 90). The mean body mass index was 32.7 kg/m2 (17.3 to 66.4).


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 2 | Pages 172 - 180
1 May 1953
Barnes R

1. Forty-eight cases of causalgia are reviewed and the clinical features are briefly described. 2. Multiple nerve injuries are common and the pain is often associated with all the injured nerves. In the upper limb there was always an incomplete lesion of the lower trunk or medial cord of the brachial plexus, or of the median nerve. In the lower limb there was always an incomplete lesion of the medial popliteal division of the sciatic, the medial popliteal, or the posterior tibial nerve. These nerves carry most of the sympathetic fibres to the hand and foot. With two exceptions all the nerve lesions were at or above the level of the knee or elbow. 3. Sympathectomy gives marked relief of pain in most cases of causalgia. Prompt treatment is essential to prevent the crippling deformities which follow prolonged voluntary immobilisation of the painful limb. The results of preganglionic are superior to those of postganglionic sympathectomy. 4. The possible pain pathways are discussed, and an explanation is offered for the successful results of sympathectomy in the treatment of causalgia


Bone & Joint Research
Vol. 8, Issue 10 | Pages 443 - 450
1 Oct 2019
Treacy RBC Holland JP Daniel J Ziaee H McMinn DJW

Objectives

Modern metal-on-metal (MoM) hip resurfacing arthroplasty (HRA), while achieving good results with well-orientated, well-designed components in ideal patients, is contraindicated in women, men with head size under 50 mm, or metal hypersensitivity. These patients currently have no access to the benefits of HRA. Highly crosslinked polyethylene (XLPE) has demonstrated clinical success in total hip arthroplasty (THA) and, when used in HRA, potentially reduces metal ion-related sequelae. We report the early performance of HRA using a direct-to-bone cementless mono-bloc XLPE component coupled with a cobalt-chrome femoral head, in the patient group for whom HRA is currently contraindicated.

Methods

This is a cross-sectional, observational assessment of 88 consecutive metal-on-XLPE HRAs performed in 84 patients between 2015 and 2018 in three centres (three surgeons, including the designer surgeon). Mean follow-up is 1.6 years (0.7 to 3.9). Mean age at operation was 56 years (sd 11; 21 to 82), and 73% of implantations were in female patients. All patients were individually counselled, and a detailed informed consent was obtained prior to operation. Primary resurfacing was carried out in 85 hips, and three cases involved revision of previous MoM HRA. Clinical, radiological, and Oxford Hip Score (OHS) assessments were studied, along with implant survival.


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 3 | Pages 285 - 293
1 Aug 1979
Mubarak S Carroll N

A review was conducted of the records of fifty-five children who were admitted to the Hospital for Sick Children in Toronto between 1955 and 1975 with a diagnosis of Volkmann's contracture in fifty-eight limbs. Ten patients had been transferred to this hospital with established ischaemia after Bryant's traction for a fractured femur; all had a very poor outcome. Thirteen other cases of Volkmann's contracture affecting the superficial posterior compartment had been treated with a fixed Thomas' splint and a Bradford frame after fractures of the femoral shaft. Supracondylar fractures of the elbow resulting in Volkmann's contracture frequently had both an arterial injury and a compartment syndrome. Most of the fifty-five children reviewed here had not had early appropriate treatment. For the past twenty-one years the frequency of Volkmann's contracture has not declined in spite of many published reports on the compartment syndrome, and the hazards of supracondylar fractures and of Bryant's traction


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 3 | Pages 429 - 439
1 Aug 1971
Jones ERL Esah M

1. Thirty-four cases of displaced fracture of the neck of the radius in children are reviewed with special reference to elbow and forearm function. 2. There were eight poor functional results-four after eighteen closed reductions and four after sixteen open reductions. 3. The causes of the poor functional results are recorded and the complications discussed. Union in a displaced position was the main cause of restricted movement. Deformity of the radial head due to avascular necrosis, and fibrous adhesions between the neck of the radius and the ulna, were other factors. 4. Fractures that were held reduced by Kirschner wires had better results than comparable fractures treated by closed reduction or op en reduction without fixation. 5. It is concluded that all fractures, whatever the age of the child, with angular displacement exceeding 15 degrees need accurate reduction. Closed reduction is not easy, and repeated check radiographs are needed to ensure maintenance of reduction. Certain of these fractures are unstable and require internal fixation with Kirschner wires


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 293 - 296
1 Mar 1985
Bell M Beauchamp C Kellam J McMurtry R

Excellent results can be achieved by plating fractures of the shaft of the humerus in patients with multiple injuries. This helps in nursing care and in the management of other injuries. In 38 patients admitted to a regional trauma centre, 39 humeral shaft fractures were plated. There were 27 men and 11 women, with an average age of 31.5 years. Fourteen of the humeral fractures were compound and 20 had significant comminution; 23 were fixed by a plate on the day of admission and all 39 by the twentieth day. Follow-up of 34 fractures showed that all had united, 33 primarily. All patients but one had a fully functional shoulder and no patient with a fractured humerus alone had lost any elbow movement. Complications were rare--one case each of non-union, fixation failure and infection. No permanent nerve injuries were produced at operation. The plating of fractures of the humerus in these circumstances has been shown to produce excellent results and has a place in the management of the patient with multiple injuries


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 888 - 893
1 Aug 2001
Mazda K Boggione C Fitoussi F Penneçot GF

We report the results of 116 consecutive displaced extension supracondylar fractures of the elbow in children treated during the first two years after the introduction of the following protocol; closed reduction under general anaesthesia with fluoroscopic control and lateral percutaneous pinning using two parallel pins or, when closed reduction failed, open reduction and internal fixation by cross-pinning. Eight patients were lost to follow-up during the first postoperative year. The mean follow-up for the remaining 108 was 27.9 months (12 to 47, median 26.5). At the final follow-up, using Flynn’s overall modified classification, the clinical result was considered to be excellent in 99 patients (91.6%), good in five (4.6%) and poor in four (3.7%). All the poor results were due to a poor cosmetic result, but had good or excellent function. Technical error in the initial management of these four cases was thought to be the cause of the poor results. The protocol described resulted in good or excellent results in 96% of our patients, providing a safe and efficient treatment for displaced supracondylar fractures of the humerus even in less experienced hands