The aim of this study was to report patient and clinical outcomes following robotic-assisted total knee arthroplasty (RA-TKA) at multiple institutions with a minimum two-year follow-up. This was a multicentre registry study from October 2016 to June 2021 that included 861 primary RA-TKA patients who completed at least one pre- and postoperative patient-reported outcome measure (PROM) questionnaire, including Forgotten Joint Score (FJS), Knee Injury and Osteoarthritis Outcomes Score for Joint Replacement (KOOS JR), and pain out of 100 points. The mean age was 67 years (35 to 86), 452 were male (53%), mean BMI was 31.5 kg/m2 (19 to 58), and 553 (64%) cemented and 308 (36%) cementless implants.Aims
Methods
Anterior cruciate ligament (ACL) rupture commonly leads to post-traumatic osteoarthritis, regardless of surgical reconstruction. This study uses standing MRI to investigate changes in contact area, contact centroid location, and tibiofemoral alignment between ACL-injured knees and healthy controls, to examine the effect of ACL reconstruction on these parameters. An upright, open MRI was used to directly measure tibiofemoral contact area, centroid location, and alignment in 18 individuals with unilateral ACL rupture within the last five years. Eight participants had been treated nonoperatively and ten had ACL reconstruction performed within one year of injury. All participants were high-functioning and had returned to sport or recreational activities. Healthy contralateral knees served as controls. Participants were imaged in a standing posture with knees fully extended.Aims
Methods
This systematic review aims to compare the precision of component positioning, patient-reported outcome measures (PROMs), complications, survivorship, cost-effectiveness, and learning curves of MAKO robotic arm-assisted unicompartmental knee arthroplasty (RAUKA) with manual medial unicompartmental knee arthroplasty (mUKA). Searches of PubMed, MEDLINE, and Google Scholar were performed in November 2021 according to the Preferred Reporting Items for Systematic Review and Meta-Analysis statement. Search terms included “robotic”, “unicompartmental”, “knee”, and “arthroplasty”. Published clinical research articles reporting the learning curves and cost-effectiveness of MAKO RAUKA, and those comparing the component precision, functional outcomes, survivorship, or complications with mUKA, were included for analysis.Aims
Methods
An anteroposterior radiograph of the leg to include the hip and ankle, taken with the patient standing, provides an estimate of the line of load-bearing at the knee. Gait analysis may be used to determine the way in which the load in the knee is shared between the medial and
The aim of this study was to compare the clinical outcomes of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) during the first six weeks and at one year postoperatively. A per protocol analysis of 76 patients, 43 of whom underwent TKA and 34 of whom underwent bi-UKA, was performed from a prospective, single-centre, randomized controlled trial. Diaries kept by the patients recorded pain, function, and the use of analgesics daily throughout the first week and weekly between the second and sixth weeks. Patient-reported outcome measures (PROMs) were compared preoperatively, and at three months and one year postoperatively. Data were also compared longitudinally and a subgroup analysis was conducted, stratified by preoperative PROM status.Aims
Methods
Anterior tibial translation was measured in both knees using the radiological Lachman test and the lateral monopodal stance tests in 281 patients with unilateral anterior cruciate ligament (ACL) rupture. Measurements of translation in the medial compartment were more useful than those in the
Medial tibial plateaux excised during 46 unicompartmental arthroplasties for osteoarthritis were collected and photographed. The anterior cruciate ligament was intact in all joints. In every case the cartilage and bone erosion was centred anteriorly on the plateau and the posterior cartilage was intact. The site of the lesion and the intact state of the cruciate ligaments taken together explain why varus deformity was observed only in the extended knee, and why the deformity was correctable and had not become fixed. Failure of the anterior cruciate ligament may allow the erosion to extend posteriorly, producing fixed varus deformity and leading to degeneration of the
We describe 88 knees (79 patients) with lateral unicompartmental osteoarthritis which had been treated by the St Georg Sled prosthesis. At a mean follow-up of nine years (2 to 21) 15 knees had revision surgery, nine for progression of arthritis, six for loosening, four for breakage of a component and four for more than one reason. Six patients complained of moderate or severe pain at the final follow-up. Only five knees were lost to follow-up in the 21-year period. We performed survivorship analysis on the group using revision for any cause as the endpoint. At ten years the cumulative survival rate was 83%, and at 15 years, when ten knees were still at risk, it was 74%. Based on our clinical results and survival rate the St Georg Sled may be considered to be a suitable unicompartmental replacement for isolated
We have analysed retrospectively the relationship between the axial parameters of alignment of the lower limb and the recurrence of varus deformity after high tibial osteotomy. We studied 29 patients (37 knees) with a mean age at surgery of 66 years. The mean follow-up was for 7.4 years (5 to 10.5). Recurrence of varus deformity was defined as an increase in the femorotibial angle of 3° or more, compared with that obtained six months after the operation. There were four patients (four knees) with recurrence of varus deformity. They had a greater varus inclination of the distal femur than those without varus recurrence. An association between varus inclination of the distal femur and horizontal obliquity of the joint surface was observed. Excessive obliquity prevents the shift of weight-bearing to the
We evaluated the outcome of partial lateral meniscectomy of 31 knees in 29 patients whose knees were otherwise normal. The mean follow-up was 10.3 years. According to the Lysholm score, 14 knees were rated as excellent, four as good, five as fair and eight as poor, with a mean score of 80.5 points. Radiologically, only one
Osteoarthritis (OA) is the most prevalent systemic musculoskeletal disorder, characterized by articular cartilage degeneration and subchondral bone (SCB) sclerosis. Here, we sought to examine the contribution of accelerated growth to OA development using a murine model of excessive longitudinal growth. Suppressor of cytokine signalling 2 (SOCS2) is a negative regulator of growth hormone (GH) signalling, thus mice deficient in SOCS2 ( We examined vulnerability of Aims
Methods
When the Oxford unicompartmental meniscal bearing arthroplasty is used in the
We report the outcome of 135 knees with anteromedial osteoarthritis in which the Oxford meniscal-bearing unicompartmental arthroplasty was inserted in a district general hospital by a single surgeon. All the knees had an intact anterior cruciate ligament, a correctable varus deformity and the
Fresh osteochondral allografts were used to repair post-traumatic osteoarticular defects in 92 knees. At the time of grafting, varus or valgus deformities were corrected by upper tibial or supracondylar femoral osteotomies. A survivorship analysis was performed in which failure was defined as the need for a revision operation or the persistence of the pre-operative symptoms. There was a 75% success rate at five years, 64% at ten years and 63% at 14 years. The failure rate was higher for bipolar grafts than for unipolar and the results in patients over the age of 60 years were poor. The outcome did not depend on the sex of the patient and the results of allografts in the medial and
We describe the outcome of a series of 124 Oxford meniscal-bearing unicompartmental arthroplasties carried out for osteoarthritis of the medial compartment. They had been undertaken more than ten years ago in a non-teaching hospital in Sweden by three surgeons. All the knees had an intact anterior cruciate ligament, a correctable varus deformity and full-thickness cartilage in the
On three occasions we have reviewed a series of knees after high tibial osteotomy for osteoarthritis: 99 were reviewed at one to two years; 81 at a mean of 5.7 years; and 65 at a mean of 11.9 years. At one to two years and at 5.7 years over 50% were good and over 75% acceptable. At 11.9 years, 43% were good and 60% acceptable. We determined the mechanical axis through the knee in maximum varus and maximum valgus; significantly better results were found if a mean angulation of 3 degrees to 7 degrees of valgus had been achieved at operation. We also measured intercondylar distances under varus and valgus stress, and found no significant
We determined the outcome of 56 ‘Oxford’ unicompartmental replacements performed for anteromedial osteoarthritis of the knee between 1982 and 1987. Of these, 24 were in patients who had died without revision, one was lost to follow-up and two had been revised. Of the remaining 29 knees, 26 were examined clinically and radiologically, two were only examined clinically and one patient was contacted by telephone. The mean age of the patients was 80.3 years. At a mean follow-up of 11.4 years (10 to 14) the measurements of the knee score, range of movement and degree of deformity were not significantly different from those made one to two years after operation, except that the range of flexion had improved. Comparison of fluoroscopically-controlled radiographs at a similar interval of time showed no change in the appearance of the
In the last decade, interest in partial knee arthroplasties and bicruciate retaining total knee arthroplasties has increased. In addition, patient-related outcomes and functional results such as range of movement and ambulation may be more promising with less invasive procedures such as bicompartmental arthroplasty (BCA). The purpose of this study is to evaluate clinical and radiological outcomes after a third-generation patellofemoral arthroplasty (PFA) combined with a medial or lateral unicompartmental knee arthroplasty (UKA) at mid- to long-term follow-up. A total of 57 procedures were performed. In 45 cases, a PFA was associated with a medial UKA and, in 12, with a lateral UKA. Patients were followed with validated patient-reported outcome measures (Oxford Knee Score (OKS), EuroQol five-dimension questionnaire (EQ-5D), EuroQoL Visual Analogue Scale (EQ-VAS)), the Knee Society Score (KSS), the Forgotten Joint Score (FJS), and radiological analysis.Aims
Methods
After a unicompartmental Oxford knee replacement, a clear lateral radiographic view of the components may be obtained without the shadow of prosthetic components in the other compartment. Radiographs of 20 knees were studied; with the patient supine and the muscles relaxed, views with the knee at full extension and 90 degrees of flexion were obtained and the movement of the meniscal bearings over this range of flexion was measured. The bearings were found to move backwards on the tibia through an average distance of 4.4 mm (range 0.0 to 13.5 mm) in the medial compartment and 6.0 mm (range 1.6 to 13.0 mm) in the
We report the incidence of osteolysis in the femur, tibia, and patella of 44 consecutive patients (60 knees) who were followed for more than seven years after cementless knee arthroplasty with a Porous-Coated Anatomic prosthesis. The average age of the patients was 56.5 years (17 to 73); the operative diagnosis was osteoarthritis (33 knees), rheumatoid arthritis (17), tuberculous arthritis (7) and post-traumatic arthritis (3). All patellae were resurfaced. No femoral or tibial component was loose at the final follow-up examination. Thirty patellar components were loose of which six had been revised. Radiographs revealed osteolysis in 90% of the tibial plateaux and in 80% of the 30 intact patellar prostheses. No osteolysis was seen around any femoral component. In 50 knees (83%) the average wear of the polyethylene liner was 2.5 mm in the medial compartment and 1.7 mm in the