Advertisement for orthosearch.org.uk
Results 801 - 820 of 2208
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1555 - 1560
4 Oct 2021
Phillips JRA Tucker K

Aims

Knee arthroplasty surgery is a highly effective treatment for arthritis and disorders of the knee. There are a wide variety of implant brands and types of knee arthroplasty available to surgeons. As a result of a number of highly publicized failures, arthroplasty surgery is highly regulated in the UK and many other countries through national registries, introduced to monitor implant performance, surgeons, and hospitals. With time, the options available within many brand portfolios have grown, with alternative tibial or femoral components, tibial insert materials, or shapes and patella resurfacings. In this study we have investigated the effect of the expansion of implant brand portfolios and where there may be a lack of transparency around a brand name. We also aimed to establish the potential numbers of compatible implant construct combinations.

Methods

Hypothetical implant brand portfolios were proposed, and the number of compatible implant construct combinations was calculated.


Aims

To report early (two-year) postoperative findings from a randomized controlled trial (RCT) investigating disease-specific quality of life (QOL), clinical, patient-reported, and radiological outcomes in patients undergoing a total shoulder arthroplasty (TSA) with a second-generation uncemented trabecular metal (TM) glenoid versus a cemented polyethylene glenoid (POLY) component.

Methods

Five fellowship-trained surgeons from three centres participated. Patients aged between 18 and 79 years with a primary diagnosis of glenohumeral osteoarthritis were screened for eligibility. Patients were randomized intraoperatively to either a TM or POLY glenoid component. Study intervals were: baseline, six weeks, six-, 12-, and 24 months postoperatively. The primary outcome was the Western Ontario Osteoarthritis Shoulder QOL score. Radiological images were reviewed for metal debris. Mixed effects repeated measures analysis of variance for within and between group comparisons were performed.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 93 - 98
1 Jan 1997
Britton AR Murray DW Bulstrode CJ McPherson K Denham RA

We have assessed the relative value of various outcome measures after THR, by the analysis of follow-up data from over 2000 patients. They had been reviewed clinically and radiologically six months after operation, at one year, and then every two years, some for 16 years. At each review their pain level, stiffness and opinion of progress were scored and a radiograph taken. We found that pain level was the most informative outcome as a predictor of revision and correlated well with the patients’ opinions. We made a comparison between the six types of implant in the series, using survival analysis and log-rank testing with different pain levels as endpoints. This analysis revealed differences which were not detected by survival analysis using the traditional endpoint of revision. We therefore recommend the use of different levels of pain as the main outcome measures after total hip replacement


Bone & Joint Research
Vol. 2, Issue 6 | Pages 102 - 111
1 Jun 2013
Patel RA Wilson RF Patel PA Palmer RM

Objectives. To review the systemic impact of smoking on bone healing as evidenced within the orthopaedic literature. Methods. A protocol was established and studies were sourced from five electronic databases. Screening, data abstraction and quality assessment was conducted by two review authors. Prospective and retrospective clinical studies were included. The primary outcome measures were based on clinical and/or radiological indicators of bone healing. This review specifically focused on non-spinal orthopaedic studies. Results. Nine tibia studies and eight other orthopaedic studies were considered for systematic review. Of these 17 studies, 13 concluded that smoking negatively influenced bone healing. Conclusions. Smoking has a negative effect on bone healing, in terms of delayed union, nonunion and more complications


Bone & Joint 360
Vol. 10, Issue 5 | Pages 24 - 28
1 Oct 2021


Bone & Joint 360
Vol. 10, Issue 4 | Pages 22 - 27
1 Aug 2021


Bone & Joint Open
Vol. 2, Issue 8 | Pages 671 - 678
19 Aug 2021
Baecker H Frieler S Geßmann J Pauly S Schildhauer TA Hanusrichter Y

Aims

Fungal periprosthetic joint infections (fPJIs) are rare complications, constituting only 1% of all PJIs. Neither a uniform definition for fPJI has been established, nor a standardized treatment regimen. Compared to bacterial PJI, there is little evidence for fPJI in the literature with divergent results. Hence, we implemented a novel treatment algorithm based on three-stage revision arthroplasty, with local and systemic antifungal therapy to optimize treatment for fPJI.

Methods

From 2015 to 2018, a total of 18 patients with fPJI were included in a prospective, single-centre study (DKRS-ID 00020409). The diagnosis of PJI is based on the European Bone and Joint Infection Society definition of periprosthetic joint infections. The baseline parameters (age, sex, and BMI) and additional data (previous surgeries, pathogen spectrum, and Charlson Comorbidity Index) were recorded. A therapy protocol with three-stage revision, including a scheduled spacer exchange, was implemented. Systemic antifungal medication was administered throughout the entire treatment period and continued for six months after reimplantation. A minimum follow-up of 24 months was defined.


Bone & Joint Research
Vol. 10, Issue 9 | Pages 591 - 593
7 Sep 2021
Thompson JW Simpson AHRW Haddad FS


Bone & Joint Open
Vol. 2, Issue 7 | Pages 540 - 544
19 Jul 2021
Jensen MM Milosevic S Andersen GØ Carreon L Simony A Rasmussen MM Andersen MØ

Aims

The aim of this study was to identify factors associated with poor outcome following coccygectomy on patients with chronic coccydynia and instability of the coccyx.

Methods

From the Danish National Spine Registry, DaneSpine, 134 consecutive patients were identified from a single centre who had coccygectomy from 2011 to 2019. Patient demographic data and patient-reported outcomes, including pain measured on a visual analogue scale (VAS), Oswestry Disability Index (ODI), EuroQol five-dimension five-level questionnaire, and 36-Item Short-Form Health Survey questionnaire (SF-36) were obtained at baseline and at one-year follow-up. Patient satisfaction was obtained at follow-up. Regression analysis, including age, sex, smoking status, BMI, duration of symptoms, work status, welfare payment, preoperative VAS, ODI, and SF-36 was performed to identify factors associated with dissatisfaction with results at one-year follow-up.


Bone & Joint Open
Vol. 2, Issue 8 | Pages 631 - 637
10 Aug 2021
Realpe AX Blackstone J Griffin DR Bing AJF Karski M Milner SA Siddique M Goldberg A

Aims

A multicentre, randomized, clinician-led, pragmatic, parallel-group orthopaedic trial of two surgical procedures was set up to obtain high-quality evidence of effectiveness. However, the trial faced recruitment challenges and struggled to maintain recruitment rates over 30%, although this is not unusual for surgical trials. We conducted a qualitative study with the aim of gathering information about recruitment practices to identify barriers to patient consent and participation to an orthopaedic trial.

Methods

We collected 11 audio recordings of recruitment appointments and interviews of research team members (principal investigators and research nurses) from five hospitals involved in recruitment to an orthopaedic trial. We analyzed the qualitative data sets thematically with the aim of identifying aspects of informed consent and information provision that was either unclear, disrupted, or hindered trial recruitment.


Bone & Joint 360
Vol. 10, Issue 4 | Pages 45 - 47
1 Aug 2021


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1550 - 1550
1 Sep 2021


Bone & Joint 360
Vol. 10, Issue 4 | Pages 14 - 17
1 Aug 2021


Bone & Joint 360
Vol. 1, Issue 4 | Pages 10 - 12
1 Aug 2012

The August 2012 Hip & Pelvis Roundup. 360. looks at: whether cemented hip replacement might be bad for your health; highly cross-linked polyethylene; iHOT-33 - a new hip outcome measure; hamstring injuries; total hip replacement; stemmed metal-on-metal THR; bipolar hemiarthroplasty, neuromuscular disease and dislocation; the high risk of secondary hemiarthroplasty; and whether we have to repair the labrum after all?


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1457 - 1461
1 Sep 2021
Esworthy GP Johnson NA Divall P Dias JJ

Aims

The aim of this study was to identify the origin and development of the threshold for surgical intervention, highlight the consequences of residual displacement, and justify the importance of accurate measurement.

Methods

A systematic review of three databases was performed to establish the origin and adaptations of the threshold, with papers screened and relevant citations reviewed. This search identified papers investigating functional outcome, including presence of arthritis, following injury. Orthopaedic textbooks were reviewed to ensure no earlier mention of the threshold was present.


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 534 - 541
1 Apr 2016
Tsang STJ Mills LA Frantzias J Baren JP Keating JF Simpson AHRW

Aims. The aim of this study was to identify risk factors for the failure of exchange nailing in nonunion of tibial diaphyseal fractures. . Patients and Methods. A cohort of 102 tibial diaphyseal nonunions in 101 patients with a mean age of 36.9 years (15 to 74) were treated between January 1992 and December 2012 by exchange nailing. Of which 33 (32%) were initially open injuries. The median time from primary fixation to exchange nailing was 6.5 months (interquartile range (IQR) 4.3 to 9.8 months). . The main outcome measures were union, number of secondary fixation procedures required to achieve union and time to union. . Univariate analysis and multiple regression were used to identify risk factors for failure to achieve union. . Results. Multiple causes for the primary nonunion were found for 28 (27%) tibiae, with infection present in 32 (31%). Six patients were lost to follow-up. Further surgical procedures were required in 35 (36%) nonunions. Other fixation modalities were required in five fractures. A single nail exchange procedure achieved union in 60/96 (63%) of all nonunions. Only 11 out of 31 infected nonunions (35.4%) healed after one exchange nail procedure. Up to five repeated exchange nailings, with or without bone grafting, ultimately achieved union in 89 (93%) fractures. The median time to union after exchange nailing was 8.7 months (IQR 5.7 to 14.0 months). Univariate analysis confirmed that an oligotrophic/atrophic pattern of nonunion (p = 0.002), a bone gap of 5 mm or more (p = 0.04) and infection (p < 0.001), were predictive for failure of exchange nailing Multiple regression analysis found that infection was the strongest predictor of failure (p < 0.001). . Conclusion. Exchange nailing is an effective treatment for aseptic tibial diaphyseal nonunion. However, in the presence of severe infection with a highly resistant organism, or extensive sclerosis of the bone, other fixation modalities, such as Ilizarov treatment, should be considered. Take home message: Exchange nailing is an effective treatment for aseptic tibial diaphyseal nonunion. Cite this article: Bone Joint J 2016;98-B:534–41


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1206 - 1214
1 Jul 2021
Tsikandylakis G Mortensen KRL Gromov K Mohaddes M Malchau H Troelsen A

Aims

We aimed to investigate if the use of the largest possible cobalt-chromium head articulating with polyethylene acetabular inserts would increase the in vivo wear rate in total hip arthroplasty.

Methods

In a single-blinded randomized controlled trial, 96 patients (43 females), at a median age of 63 years (interquartile range (IQR) 57 to 69), were allocated to receive either the largest possible modular femoral head (36 mm to 44 mm) in the thinnest possible insert or a standard 32 mm head. All patients received a vitamin E-doped cross-linked polyethylene insert and a cobalt-chromium head. The primary outcome was proximal head penetration measured with radiostereometric analysis (RSA) at two years. Secondary outcomes were volumetric wear, periacetabular radiolucencies, and patient-reported outcomes.


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1270 - 1276
1 Jul 2021
Townshend DN Bing AJF Clough TM Sharpe IT Goldberg A

Aims

This is a multicentre, non-inventor, prospective observational study of 503 INFINITY fixed bearing total ankle arthroplasties (TAAs). We report our early experience, complications, and radiological and functional outcomes.

Methods

Patients were recruited from 11 specialist centres between June 2016 and November 2019. Demographic, radiological, and functional outcome data (Ankle Osteoarthritis Scale, Manchester Oxford Questionnaire, and EuroQol five-dimension five-level score) were collected preoperatively, at six months, one year, and two years. The Canadian Orthopaedic Foot and Ankle Society (COFAS) grading system was used to stratify deformity. Early and late complications and reoperations were recorded as adverse events. Radiographs were assessed for lucencies, cysts, and/or subsidence.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 504 - 509
1 Apr 2013
Hutchison AM Pallister I Evans RM Bodger O Topliss CJ Williams P Beard DJ

We conducted a randomised controlled trial to determine whether active intense pulsed light (IPL) is an effective treatment for patients with chronic mid-body Achilles tendinopathy. A total of 47 patients were randomly assigned to three weekly therapeutic or placebo IPL treatments. The primary outcome measure was the Victorian Institute of Sport Assessment – Achilles (VISA-A) score. Secondary outcomes were a visual analogue scale for pain (VAS) and the Lower Extremity Functional Scale (LEFS). Outcomes were recorded at baseline, six weeks and 12 weeks following treatment. Ultrasound assessment of the thickness of the tendon and neovascularisation were also recorded before and after treatment. . There was no significant difference between the groups for any of the outcome scores or ultrasound measurements by 12 weeks, showing no measurable benefit from treatment with IPL in patients with Achilles tendinopathy. Cite this article: Bone Joint J 2013;95-B:504–9


Bone & Joint Research
Vol. 3, Issue 11 | Pages 305 - 309
1 Nov 2014
Harris KK Price AJ Beard DJ Fitzpatrick R Jenkinson C Dawson J

Objective. The objective of this study was to explore dimensionality of the Oxford Hip Score (OHS) and examine whether self-reported pain and functioning can be distinguished in the form of subscales. Methods. This was a secondary data analysis of the UK NHS hospital episode statistics/patient-reported outcome measures dataset containing pre-operative OHS scores on 97 487 patients who were undergoing hip replacement surgery. . Results. The proposed number of factors to extract depended on the method of extraction employed. Velicer’s Minimum Average Partial test and the Parallel Analysis suggested one factor, the Cattell’s scree test and Kaiser-over-1 rule suggested two factors. Exploratory factor analysis demonstrated that the two-factor OHS had most of the items saliently loading either of the two factors. These factors were named ‘Pain’ and ‘Function’ and their respective subscales were created. There was some cross-loading of items: 8 (pain on standing up from a chair) and 11 (pain during work). These items were assigned to the ‘Pain’ subscale. The final ‘Pain’ subscale consisted of items 1, 8, 9, 10, 11 and 12. The ‘Function’ subscale consisted of items 2, 3, 4, 5, 6 and 7, with the recommended scoring of the subscales being from 0 (worst) to 100 (best). Cronbach’s alpha was 0.855 for the ‘Pain’ subscale and 0.861 for the ‘Function’ subscale. A confirmatory factor analysis demonstrated that the two-factor model of the OHS had a better fit. However, none of the one-factor or two-factor models was rejected. Conclusion. Factor analyses demonstrated that, in addition to current usage as a single summary scale, separate information on pain and self-reported function can be extracted from the OHS in a meaningful way in the form of subscales. Cite this article: Bone Joint Res 2014;3:305–9