Advertisement for orthosearch.org.uk
Results 801 - 820 of 1525
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 893 - 894
1 Sep 1999
Armstrong PM Ilyas I Pandey R Berendt AR Conlon CP Simpson AHRW

We describe a case of pyoderma gangrenosum which presented with severe wound breakdown after elective hip replacement. The patient was treated successfully with minimal wound debridement and steroids. This diagnosis should always be considered when confronted with an enlarging painful skin lesion which does not grow organisms when cultured and fails to respond to antibiotic therapy, especially if there are similar lesions in other sites. In patients who have a past history of pyoderma gangrenosum, prophylactic steroids may be indicated at the time of surgery or may be required early in the postoperative period


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 822 - 825
1 Aug 2003
Torisu T Kaku N Tumura H Taira H Tomari K

Between 1995 and 1997 we undertook 40 bipolar hip arthroplasties in 35 patients with dysplastic osteoarthritis. The steep and shallow acetabulum was excavated and the bipolar socket was placed high with an adjustment of leg-length. At follow-up of between five and seven years, there were 19 excellent, 16 good and five fair results according to the scoring system of Merle d’Aubigné and Postel. The mean radiographic superior migration of the bipolar socket was 2.1 mm (0 to 10). Osteolysis was noted in three hips within three years of the operation. Abduction on weight-bearing was recorded in 24 hips and the bipolar system was found to be functioning predominantly between the inner bearing and the metal femoral head in 20


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 3 | Pages 374 - 380
1 May 1987
Patterson M

Since 1964, 3573 uncemented Ring total hip replacements of all types have been performed; 194 (5.4%) have required revision for infection, loosening or breakage. Of these, 102 were available for review; 81 had satisfactory results five years after operation. These results are better than many of those reported after revision of cemented hip replacements. It is suggested that the absence of cement makes revision easier because bone erosion rarely occurs


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 741 - 745
1 Sep 1991
Furlong R Osborn J

We report the histological findings in post-mortem specimens obtained ten days, 17 days and seven weeks after implantation of hydroxyapatite-coated femoral components of hip arthroplasties. There was early deposition of woven bone on the hydroxyapatite ceramic, identical to that deposited on surviving cancellous trabeculae. The space between these deposits became bridged from both sides by new trabeculae, and there was no evidence of an inflammatory reaction or of fibrous tissue formation. The use of an hydroxyapatite coating seems to allow early, sound, secondary fixation of implants


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 1010 - 1013
1 Nov 1990
Werners R Vincent B Bulstrode C

We have reviewed 368 osteotomies carried out for osteoarthritis of the hip at the Nuffield Orthopaedic Centre. Survivorship analysis showed that 10 years after osteotomy 47% had required no further surgery, and even after 20 years 23% had still not had a hip replacement. Hips with moderate arthritic change showed significantly better results than those with more severe degeneration. Osteotomies with varus angulation as well as medial displacement showed longer survival


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 426 - 434
1 Apr 2019
Logishetty K van Arkel RJ Ng KCG Muirhead-Allwood SK Cobb JP Jeffers JRT

Aims

The hip’s capsular ligaments passively restrain extreme range of movement (ROM) by wrapping around the native femoral head/neck. We determined the effect of hip resurfacing arthroplasty (HRA), dual-mobility total hip arthroplasty (DM-THA), conventional THA, and surgical approach on ligament function.

Materials and Methods

Eight paired cadaveric hip joints were skeletonized but retained the hip capsule. Capsular ROM restraint during controlled internal rotation (IR) and external rotation (ER) was measured before and after HRA, DM-THA, and conventional THA, with a posterior (right hips) and anterior capsulotomy (left hips).


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 54 - 55
1 Jan 1999
Wroblewski BM Siney PD Fleming PA

We report the results of our continued review of 14 hip arthroplasties using alumina ceramic femoral heads with cross-linked polyethylene cups. There have been no complications and a very low rate of penetration. This was 0.02 mm per year after an initial ‘bedding-in’ period of two years. There has been no change in the mean rate between our earlier study at six years and the current results at 10 to 11 years. The use of these bearing surfaces appears to reduce the potential amount of polyethylene debris and may provide the next logical stage in the development of the Charnley low-friction arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 573 - 576
1 Jul 1998
Howie DW Middleton RG Costi K

We have compared prospectively the incidence of loosening of 20 femoral stems with a matt surface with that of 20 polished stems of an otherwise identical tapered, non-modular design of Exeter hip replacement. The stems were inserted using the same technique at operation and radiographs showed no difference in the adequacy of the cement mantle or of fixation. All the patients were reviewed regularly and none was lost to follow-up. After a minimum follow-up of nine years, four matt but no polished stems had been revised for aseptic loosening. Polished stems subsided slightly within the cement mantle early, but did not loosen


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 63 - 66
1 Jan 1992
Campbell A Rorabeck C Bourne R Chess D Nott L

A retrospective review of 148 consecutive porous-coated hip arthroplasties (PCA) showed an incidence of thigh pain of 13% one year after surgery, and 22% at two years. Positive correlations were made with femoral stem subsidence (greater than 2 mm) and with distal periosteal and endosteal bone formation. No positive correlations were made with parameters of bone quality or component fit. Resolution of pain occurred in one-third and an anti-inflammatory agent produced partial relief in two-thirds of the patients. We conclude that thigh pain is secondary to stem instability with distal stress transfer in the absence of stable proximal fixation


Bone & Joint 360
Vol. 8, Issue 3 | Pages 45 - 45
1 Jun 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 61 - 63
1 Jan 1987
Wroblewski B Lynch M Atkinson Dowson D Isaac G

We examined 59 cemented high density polyethylene sockets removed at revision hip arthroplasty. Of these 19 showed areas of wear between the outside of the socket and the acetabular bone. This was associated with lack of acrylic cement in those areas and was also related to the depth of the wear on the articulating surface of the socket. It is suggested that, in some cases, changes at the bone-cement junction are secondary to socket loosening and abrasion against the bone of the acetabulum, rather than to particles migrating from the metal-polyethylene interface. It is therefore important that impingement of the neck of the femoral stem on the edge of the cup be avoided and that, when the socket is inserted, it is not in direct contact with the bone


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 392 - 397
1 May 1986
Paterson M Fulford P Denham R

Review of the radiographs of 882 consecutive metal-to-polyethylene hip replacements after a mean follow-up of 6.8 years showed 72 cases (8%) of aseptic femoral loosening, all of which showed a lucent zone or black line between metal and cement. In 97% of the series this appeared within two years of the arthroplasty. Progress of loosening was unpredictable and only 24% had significant symptoms. Improved technique with methylmethacrylate cement in Stanmore prostheses had reduced loosening after two years from 7.9% to 0.4%. Methods of detection of early loosening are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 2 | Pages 168 - 171
1 Mar 1984
McElwaine J Colville J

A study of excision arthroplasty (Girdlestone's pseudarthrosis) for infected total hip replacements is presented. Twenty-two patients were reviewed with a minimum follow-up of one year. Reduction in pain was significant but the functional results were poor. Factors contributing to poor function were old age, poor medical condition and arthritis of the contralateral hip; these were in addition to the gross instability resulting from the pseudarthrosis. The patients were easily fatigued and dependent on external supports; calipers were found to be unacceptable. The symptoms after excision arthroplasty are compared with those before the original hip replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 344 - 349
1 Apr 2004
McCombe P Williams SA

We selected randomly a consecutive series of 162 patients requiring hip replacement to receive either a cementless, hemispherical, modular, titanium acetabular cup or a cemented, all-polyethylene cup. These replacements were performed by two surgeons in four general hospitals. The same surgical technique was used and a 26 mm metal-head femoral component was used in every case. After exclusions, 115 hips were studied for differences in rates of wear and osteolysis. The mean clinical follow-up was eight years and the mean radiological follow-up, 6.5 years. The cementless cups wore at a mean rate of 0.15 mm per year and the cemented cups at 0.07 mm per year. This difference was significant (p < 0.0001). Our findings in this mid-term study suggest that cementless cups wear more than cemented cups


Bone & Joint 360
Vol. 8, Issue 3 | Pages 1 - 1
1 Jun 2019
Bollen S


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 41 - 45
1 Jan 1990
Engelbrecht D Weber F Sweet M Jakim I

A total of 138 revision hip arthroplasties in 134 patients, all operated upon by one surgeon, were followed for an average of 7.4 years. The overall results were reasonable, with good to excellent Mayo hip scores in 62% and little or no pain in 86%. These results were independent of body weight, age, primary diagnosis and type of arthroplasty used. The incidence of radiological loosening was alarming, though comparable to that found in other series. Our findings indicate that it may be wise to replace both components even when, after careful assessment before and during operation, one of them seems to be securely fixed


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 364 - 366
1 May 1988
Pople I Phillips H

The serum liver enzyme levels of 40 consecutive patients before and after cemented hip replacement were compared with a control group having operation without use of cement. Serum gammaglutamyl transferase (SGGT) was abnormally raised, for more than four days, in 12 of the 40 patients (32%) in whom bone cement was used, compared with one of the 36 control patients. The changes in SGGT levels after operation correlated with the weight of cement used (r = 0.66, p less than 0.001), but there was return to normal levels in all patients. A temporary dose-related effect of bone cement on liver function is demonstrated


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 18 - 21
1 Jan 1996
Kreibich DN Moran CG Delves HT Owen TD Pinder IM

We measured the levels of cobalt and chromium in the serum in three groups of patients after uncemented porous-coated arthroplasty. Group 1 consisted of 14 consecutive patients undergoing revision for aseptic loosening. Group 2 comprised 14 matched patients in whom the arthroplasty was stable and group 3 was 14 similarly matched patients with arthritis awaiting hip replacement. Specimens were analysed using atomic absorption spectrophotometry. Aseptic loosening of a component resulted in a significant elevation of serum cobalt (p < 0.05), but not of serum chromium. The relative risk of a component being loose, if the patient had a serum cobalt greater than 9.0 nmol/l, was 2.8


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 185 - 189
1 Mar 2004
Kishida Y Sugano N Nishii T Miki H Yamaguchi K Yoshikawa H

We investigated the effect of the Birmingham hip resurfacing (BHR) arthroplasty on the bone mineral density (BMD) of the femur. A comparative study was carried out on 26 hips in 25 patients. Group A consisted of 13 patients (13 hips) who had undergone resurfacing hip arthroplasty with the BHR system and group B of 12 patients (13 hips) who had had cementless total hip arthroplasty with a proximal circumferential plasma-spray titanium-coated anatomic Ti6A14V stem. Patients were matched for gender, state of disease and age at the time of surgery. The periprosthetic BMD of the femur was measured using dual-energy x-ray absorptiomentry of the Gruen zones at two years in patients in groups A and B. The median values of the BMD in zones 1 and 7 were 99% and 111%, respectively. The post-operative loss of the BMD in the proximal femur was significantly greater in group B than in group A. These findings show that the BHR system preserves the bone stock of the proximal femur after surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 943 - 948
1 Jul 2006
Phillips JE Crane TP Noy M Elliott TSJ Grimer RJ

The Control of Infection Committee at a specialist orthopaedic hospital prospectively collected data on all episodes of bacteriologically-proven deep infection arising after primary hip and knee replacements over a 15-year period from 1987 to 2001. There were 10 735 patients who underwent primary hip or knee replacement. In 34 of 5947 hip replacements (0.57%) and 41 of 4788 knee replacements (0.86%) a deep infection developed. The most common infecting micro-organism was coagulase-negative staphylococcus, followed by Staphylococcus aureus, enterococci and streptococci. Of the infecting organisms, 72% were sensitive to routine prophylactic antimicrobial agents. Of the infections, 29% (22) arose in the first three months following surgery, 35% between three months and one year (26), and 36% (27) after one year. Most cases were detected early and treated aggressively, with eradication of the infection in 96% (72). There was no significant change in the infection rate or type of infecting micro-organism over the course of this study. These results set a benchmark, and importantly emphasise that only 64% of peri-prosthetic infections arise within one year of surgery. These results also illustrate the advantages of conducting joint replacement surgery in the isolation of a specialist hospital