Since the introduction of the National Institute
for Health and Care Excellence (NICE) guidelines on thromboprophylaxis
and the use of extended thromboprophylaxis with new oral agents,
there have been reports of complications arising as a result of
their use. We have looked at the incidence of wound complications
after the introduction of dabigatran for thromboprophylaxis in our
unit. We investigated the rate of venous thromboembolism and wound
leakage in 1728 patients undergoing primary joint replacement, both
before and after the introduction of dabigatran, and following its
subsequent withdrawal from our unit. We found that the use of dabigatran led to a significant increase
in post-operative wound leakage (20% with dabigatran, 5% with a
multimodal regimen; p <
0.001), which also resulted in an increased
duration of hospital stay. The rate of thromboembolism in patients
receiving dabigatran was higher (1.3%) than in those receiving the multimodal
thromboprophylaxis regimen, including low molecular weight heparin
as an inpatient and the extended use of aspirin (0.3%, p = 0.047).
We have ceased the use of dabigatran for thromboprophylaxis in these
patients. Cite this article:
The December 2013 Knee Roundup360 looks at: Conflict of interest and hyaluronic acid; Will time indeed tell in microfracture?; Contralateral knee pain and joint replacement outcomes; Patient satisfaction and knee replacement?; Hope in the cytokines for painful TKRs?; Pain severity, cytokines and osteoarthritis?; Quadriceps weakness and pain; and spontaneous osteonecrosis of the knee
A number of studies have reported satisfactory
results from the isolated revision of an acetabular component. However,
many of these studies reported only the short- to intermediate-term
results of heterogeneous bearing surfaces in a mixed age group. We present our experience of using a ceramic-on-ceramic (CoC)
bearing for isolated revision of an uncemented acetabular component
in 166 patients (187 hips) who were under the age of 50 years at
the time of revision. There were 78 men and 88 women with a mean
age of 47.4 years (28 to 49). The most common reason for revision
was polyethylene wear and acetabular osteolysis in 123 hips (66%),
followed by aseptic loosening in 49 hips (26%). We report the clinical and radiological outcome, complication
rate, and survivorship of this group. The mean duration of follow-up
was 15.6 years (11 to 19). The mean pre-operative Harris hip score was 33 points (1 to 58),
and improved to a mean of 88 points (51 to 100) at follow-up. The
mean pre-operative total Western Ontario and McMaster Universities
Osteoarthritis Index score was 63.2 (43 to 91) and improved to 19.8
points (9 to 61) post-operatively. Overall, 153 of 166 patients
(92%) were satisfied with their outcome. Kaplan–Meier survivorship
analysis, with revision or radiological evidence of implant failure
(13 patients, 8%) as end-points, was 92% at 15 years (95% confidence
interval 0.89 to 0.97). Isolated revision of a cementless acetabular component using
a CoC bearing gives good results in patients under 50 years of age. Cite this article:
We aimed to determine whether cemented hemiarthroplasty
is associated with a higher post-operative mortality and rate of
re-operation when compared with uncemented hemiarthroplasty. Data
on 19 669 patients, who were treated with a hemiarthroplasty following
a fracture of the hip in a nine-year period from 2002 to 2011, were extracted
from NHS Scotland’s acute admission database (Scottish Morbidity
Record, SMR01). We investigated the rate of mortality at day 0,
1, 7, 30, 120 and one-year post-operatively using 12 case-mix variables
to determine the independent effect of the method of fixation. At
day 0, those with a cemented hemiarthroplasty had a higher rate
of mortality (p <
0.001) compared with those with an uncemented
hemiarthroplasty, equivalent to one extra death per 424 procedures.
By day one this had become one extra death per 338 procedures. Increasing
age and the five-year co-morbidity score were noted as independent
risk factors. By day seven, the cumulative rate of mortality was
less for cemented hemiarthroplasty though this did not reach significance
until day 120. The rate of re-operation was significantly higher
for uncemented hemiarthroplasty. Despite adjusting for 12 confounding
variables, these only accounted for 15% of the observed variability. The debate about the choice of the method of fixation for a hemiarthroplasty
with respect to the rate of mortality or the risk of re-operation
may be largely superfluous. Our results suggest that uncemented
hemiarthroplasties may have a role to play in elderly patients with
significant co-morbid disease. Cite this article:
The October 2013 Knee Roundup360 looks at: Make it easy, release the MCL; Do patients remember clinical information in day surgery?; Osteoarthritis and arthroscopy?; How best to double your bundles; When to operate for infection; Cementless unicompartment knee replacement?; Tibial tubercle-trochlear groove confusion; Tarts, cherries and osteoarthritis
The June 2015 Research Roundup360 looks at: Tranexamic acid: just give it – it’s not important how!; The anterolateral ligament re-examined; Warfarin a poor post-operative agent; Passive exoskeleton the orthosis of the future?; Musculoskeletal medicine: a dark art to UK medical students?; Alendronic acid and bone density post arthroplasty; Apples with oranges? Knee functional scores revisited
The April 2014 Hip & Pelvis Roundup360 looks at: Recent arthroplasty and flight; whether that squeak could be a fracture; diagnosing early infected hip replacement; impaction grafting at a decade; whether squeaking is more common than previously thought; femoral offset associated with post THR outcomes; and periprosthetic fracture stabilisation.
The long term biological effects of wear products
following total hip arthroplasty (THA) are unclear. However, the indications
for THA are expanding, with increasingly younger patients undergoing
the procedure. This prospective, randomised study compared two groups of patients
undergoing THA after being randomised to receive one of two different
bearing surfaces: metal-on-polyethylene (MoP) n = 22 and metal-on-metal
(MoM) n = 23. We investigated the relationship between three variables:
bearing surface (MoP Our results demonstrated significantly higher mean cobalt and
chromium (Co and Cr) blood levels in the MoM group at all follow-up
points following surgery (p <
0.01), but there were no significant
differences in the chromosomal aberration indices between MoM and
MoP at two or five years (two years: p = 0.56, p = 0.08, p = 0.91, p
= 0.51 and five years: p = 0.086, p = 0.73, p = 0.06, p = 0.34)
for translocations, breaks, loss and gain of chromosomes respectively.
Regression analysis showed a strong linear relationship between
Cr levels and the total chromosomal aberration indices in the MoM
group (R2 = 0.90016), but this was not as strong for
Co (R2 = 0.68991). In the MoP group, the analysis revealed
a poor relationship between Cr levels and the total chromosomal
aberration indices (R2 = 0.23908) but a slightly stronger
relationship for Co (R2 = 0.64292). Across both groups,
Spearman’s correlation detected no overall association between Co and Cr
levels and each of the studied chromosomal aberrations. There remains
no clear indication which THA bearing couple is the most biocompatible,
especially in young active patients. While THA continues to be very
successful at alleviating pain and restoring function, the long-term
biological implications of the procedure still require further scrutiny. Cite this article:
The June 2014 Children’s orthopaedics Roundup360 looks at: plaster wedging in paediatric forearm fractures; the medial approach for DDH; Ponseti – but not as he knew it?; Salter osteotomy more accurate than Pemberton in DDH; is the open paediatric fracture an emergency?; bang up-to-date with femoral external fixation; indomethacin, heterotopic ossification and cerebral palsy hips; lengthening nails for congenital femoral deformities, and is MRI the answer to imaging of the physis?
The August 2013 Research Roundup360 looks at: passive smoking and bone substitutes; platelet-rich plasma and osteogenesis; plantar fasciitis and platelet-rich plasma: a match made in heaven?; MRSA decolonisation decreases infection rates; gums, bisphosphonates and orthopaedics; PRAISE and partner violence; blunt impact and post-traumatic OA; and IDEAL research and implants
We report a systematic review and meta-analysis
of published randomised and quasi-randomised trials evaluating the
efficacy of pre-operative skin antisepsis and cleansing techniques
in reducing foot and ankle skin flora. The post-preparation culture
number (Post-PCN) was the primary outcome. The data were evaluated
using a modified version of the Cochrane Collaboration’s tool. We
identified eight trials (560 participants, 716 feet) that met the inclusion
criteria. There was a significant difference in the proportions
of Post-PCN between hallux nailfold (HNF) and toe web spaces (TWS)
sites: 0.47 Meta-analyses showed that alcoholic chlorhexidine had better
efficacy than alcoholic povidone-iodine (PI) at HNF sites (risk
difference 0.19 (95% CI 0.08 to 0.30); p = 0.0005); a two-step intervention
using PI scrub and paint (S&
P) followed by alcohol showed significantly
better efficacy over PI (S&
P) alone at TWS sites (risk difference
0.13 (95% CI 0.02 to 0.24); p = 0.0169); and a two-step intervention
using chlorhexidine scrub followed by alcohol showed significantly
better efficacy over PI (S&
P) alone at the combined (HNF with
TWS) sites (risk difference 0.27 (95% CI 0.13 to 0.40); p <
0.0001).
No significant difference was found between cleansing techniques. Cite this article:
We systematically reviewed all the evidence published
in the English language on proximal interphalangeal joint (PIPJ)
replacement, to determine its effectiveness on the function of the
hand and the associated post-operative complications. Original studies were selected if they reported clinical outcome
with a minimum of one year’s follow-up. Quality was assessed using
the Cowley systematic review criteria modified for finger-joint
replacements. Of 319 articles identified, only five were adequately
reported according to our quality criteria; there were no randomised
controlled trials. PIPJ replacements had a substantial effect size
on hand pain of -23.2 (95% confidence interval (CI) -27.3 to -19.1)
and grip strength 1.2 (95% CI -10.7 to 13.1), and a small effect
on range of movement 0.2 (95% CI -0.4 to 0.8). A dorsal approach
was most successful. Post-operative loosening occurred in 10% (95%
CI 3 to 30) of ceramic and 12.5% (95% CI 7 to 21) of pyrocarbon
replacements. Post-operative complications occurred in 27.8% (95%
CI 20 to 37). We conclude that the effectiveness of PIPJ replacement has not
been established. Small observational case studies and short-term
follow-up, together with insufficient reporting of patient data,
functional outcomes and complications, limit the value of current
evidence. We recommend that a defined core set of patients, surgical and
outcome data for this intervention be routinely and systematically
collected within the framework of a joint registry.
This randomised trial evaluated the outcome of
a single design of unicompartmental arthroplasty of the knee (UKA) with
either a cemented all-polyethylene or a metal-backed modular tibial
component. A total of 63 knees in 45 patients (17 male, 28 female)
were included, 27 in the all-polyethylene group and 36 in the metal-backed
group. The mean age was 57.9 years (39.6 to 76.9). At a mean follow-up
of 6.4 years (5 to 9.9), 11 all-polyethylene components (41%) were
revised (at a mean of 5.8 years; 1.4 to 8.0) post-operatively and
two metal-backed components were revised (at one and five years).
One revision in both groups was for unexplained pain, one in the
metal-backed group was for progression of osteoarthritis. The others
in the all-polyethylene group were for aseptic loosening. The survivorship
at seven years calculated by the Kaplan–Meier method for the all-polyethylene
group was 56.5% (95% CI 31.9 to 75.2, number at risk 7) and for
the metal-backed group was 93.8% (95% CI 77.3 to 98.4, number at
risk 16) This difference was statistically significant (p <
0.001).
At the most recent follow-up, significantly better mean Western
Ontario and McMaster Universities Arthritis Index Scores were found
in the all-polyethylene group (13.4 This randomised study demonstrates that all-polyethylene components
in this design of fixed bearing UKA had unsatisfactory results with
significantly higher rates of failure before ten years compared
with the metal-back components. Cite this article:
Tranexamic acid (TXA), an inhibitor of fibrinolysis,
reduces blood loss after total knee arthroplasty. However, its effect
on minimally invasive total hip arthroplasty (THA) is not clear.
We performed a prospective, randomised double-blind study to evaluate
the effect of two intravenous injections of TXA on blood loss in
patients undergoing minimally invasive THA. In total, 60 patients (35 women and 25 men with a mean age of
58.1 years; 17 to 84) who underwent unilateral minimally invasive
uncemented THA were randomly divided into the study group (30 patients,
20 women and ten men with a mean age of 56.5 years; 17 to 79) that
received two intravenous injections 1 g of TXA pre- and post-operatively
(TXA group), and a placebo group (30 patients, 15 women and 15 men
with a mean age of 59.5 years; 23 to 84). We compared the peri-operative
blood loss of the two groups. Actual blood loss was calculated from
the maximum reduction in the level of haemoglobin. All patients
were followed clinically for the presence of venous thromboembolism. The TXA group had a lower mean intra-operative blood loss of
441 ml (150 to 800) This prospective, randomised controlled study showed that a regimen
of two intravenous injections of 1 g TXA is effective for blood
conservation after minimally invasive THA. Cite this article:
The aim of our study was to describe the characteristics,
treatment, and outcomes of patients with periprosthetic joint infection
(PJI) and normal inflammatory markers after total knee arthroplasty
(TKA) and total hip arthroplasty (THA). In total 538 TKAs and 414 THAs underwent surgical treatment for
PJI and met the inclusion criteria. Pre-operative erythrocyte sedimentation
rate (ESR) and C-reactive protein level (CRP) were reviewed to identify
the seronegative cohort. An age- and gender-matched cohort was identified
from the remaining patients for comparison. Overall, 4% of confirmed
infections were seronegative (21 TKA and 17 THA). Of those who underwent
pre-operative aspiration, cultures were positive in 76% of TKAs
(n = 13) and 64% of THAs (n = 7). Cell count and differential were
suggestive of infection in 85% of TKA (n = 11) and all THA aspirates
(n = 5). The most common organism was coagulase-negative Cite this article:
A lack of connection between surgeons and patients in evaluating
the outcome of total knee arthroplasty (TKA) has led to the search
for the ideal patient-reported outcome measure (PROM) to evaluate
these procedures. We hypothesised that the desired psychometric properties
of the ideal outcome tool have not been uniformly addressed in studies describing
TKA PROMS. A systematic review was conducted investigating one or more facets
of patient-reported scores for measuring primary TKA outcome. Studies
were analysed by study design, subject demographics, surgical technique,
and follow-up adequacy, with the ‘gold standard’ of psychometric
properties being systematic development, validity, reliability,
and responsiveness.Objectives
Methods
The December 2012 Spine Roundup360 looks at: the Japanese neck disability index; adjacent segment degeneration; sacroiliac loads determined by limb length discrepancy; whether epidural steroids improve outcome in lumbar disc herniation; spondylodiscitis in infancy; total pedicle screws; and iliac crest autograft complications.
Exsanguination is the second most common cause
of death in patients who suffer severe trauma. The management of
haemodynamically unstable high-energy pelvic injuries remains controversial,
as there are no universally accepted guidelines to direct surgeons
on the ideal use of pelvic packing or early angio-embolisation.
Additionally, the optimal resuscitation strategy, which prevents
or halts the progression of the trauma-induced coagulopathy, remains
unknown. Although early and aggressive use of blood products in
these patients appears to improve survival, over-enthusiastic resuscitative
measures may not be the safest strategy. This paper provides an overview of the classification of pelvic
injuries and the current evidence on best-practice management of
high-energy pelvic fractures, including resuscitation, transfusion
of blood components, monitoring of coagulopathy, and procedural
interventions including pre-peritoneal pelvic packing, external
fixation and angiographic embolisation. Cite this article:
The April 2015 Spine Roundup360 looks at: Hyperostotic spine in injury; App based back pain control; Interspinous process devices should be avoided in claudication; Robot assisted pedicle screws: fad or advance?; Vancomycin antibiotic power in spinal surgery; What to do with that burst fracture?; Increasing complexity of spinal fractures in major trauma pathways; Vitamin D and spinal fractures
Mobile-bearing (MB) total knee replacement (TKR)
was introduced to reduce the risk of aseptic loosening and wear of
polyethylene inserts. However, no consistent clinical advantages
of mobile- over fixed-bearing (FB) TKR have been found. In this
study we evaluated whether mobile bearings have an advantage over
fixed bearings with regard to revision rates and clinical outcome
scores. Furthermore, we determined which modifying variables affected
the outcome. A systematic search of the literature was conducted to collect
clinical trials comparing MB and FB in primary TKR. The primary
outcomes were revision rates for any reason, aseptic loosening and
wear. Secondary outcomes included range of movement, Knee Society
score (KSS), Oxford knee score (OKS), Short-Form 12 (SF-12) score
and radiological parameters. Meta-regression techniques were used
to explore factors modifying the observed effect. Our search yielded 1827 publications, of which 41 studies met
our inclusion criteria, comprising over 6000 TKRs. Meta-analyses
showed no clinically relevant differences in terms of revision rates,
clinical outcome scores or patient-reported outcome measures between
MB and FB TKRs. It appears that theoretical assumptions of superiority
of MB over FB TKR are not borne out in clinical practice. Cite this article: