Femoral impaction bone grafting was first developed in 1987 using
morselised cancellous bone graft impacted into the femoral canal
in combination with a cemented, tapered, polished stem. We describe
the evolution of this technique and instrumentation since that time. Between 1987 and 2005, 705 revision total hip arthroplasties
(56 bilateral) were performed with femoral impaction grafting using
a cemented femoral stem. All surviving patients were prospectively
followed for a mean of 14.7 years (9.8 to 28.3) with no loss to
follow-up. By the time of the final review, 404 patients had died.Aims
Patients and Methods
This is the first prospective study to report the pre- and post-operative
patient reported outcomes and satisfaction scores following excision
of interdigital Morton’s neuroma. Between May 2006 and April 2013, we prospectively studied 99
consecutive patients (111 feet) who were to undergo excision of
a Morton’s neuroma. There were 78 women and 21 men with a mean age
at the time of surgery of 56 years (22 to 78). Patients completed
the Manchester-Oxford Foot Questionnaire (MOXFQ), Short Form-12
(SF-12) and a supplementary patient satisfaction survey three months
pre-operatively and six months post-operatively.Aims
Patients and Methods
The fundamental concept of open reduction and internal fixation
(ORIF) of ankle fractures has not changed appreciably since the
1960s and, whilst widely used, is associated with complications
including wound dehiscence and infection, prominent hardware and
failure. Closed reduction and intramedullary fixation (CRIF) using
a fibular nail, wires or screws is biomechanically stronger, requires
minimal incisions, and has low-profile hardware. We hypothesised
that fibular nailing in the elderly would have similar functional
outcomes to standard fixation, with a reduced rate of wound and
hardware problems. A total of 100 patients (25 men, 75 women) over the age of 65
years with unstable ankle fractures were randomised to undergo standard
ORIF or fibular nailing (11 men and 39 women in the ORIF group,
14 men and 36 women in the fibular nail group). The mean age was
74 years (65 to 93) and all patients had at least one medical comorbidity. Complications,
patient related outcome measures and cost-effectiveness were assessed
over 12 months.Aims
Patients and Methods
The aim of this study was to investigate differences in pain,
range of movement function and satisfaction at three months and
one year after total knee arthroplasty (TKA) in patients with an
oblique pattern of kinematic graph of the knee and those with a
varus pattern. A total of 91 patients who underwent TKA were included in this
retrospective study. Patients (59 women and 32 men with mean age
of 68.7 years; 38.6 to 88.4) were grouped according to kinematic
graphs which were generated during navigated TKA and the outcomes
between the groups were compared.Aims
Patients and Methods
We present a minimum 20-year follow-up study of 382 cemented
Exeter Universal total hip arthroplasties (350 patients) operated
on at a mean age of 66.3 years (17 to 94). All patients received the same design of femoral component, regardless
of the original diagnosis. Previous surgery had been undertaken
for 33 hips (8.6%). During the study period 218 patients with 236
hips (62%) died, 42 hips (11%) were revised and 110 hips (29%) in
96 patients were available for review. The acetabular components
were varied and some designs are now obsolete, however they were
all cemented.Aims
Patients and Methods
The aim of this to study was to compare the previously unreported
long-term survival outcome of the Oxford medial unicompartmental
knee arthroplasty (UKA) performed by trainee surgeons and consultants. We therefore identified a previously unreported cohort of 1084
knees in 947 patients who had a UKA inserted for anteromedial knee
arthritis by consultants and surgeons in training, at a tertiary
arthroplasty centre and performed survival analysis on the group
with revision as the endpoint.Aims
Patients and Methods
Smoking is associated with post-operative complications but smokers
often under-report the amount they smoke. Our objective was to determine
whether a urine dipstick test could be used as a substitute for
quantitative cotinine assays to determine smoking status in patients. Between September 2013 and July 2014 we conducted a prospective
cohort study in which 127 consecutive patients undergoing a planned
foot and ankle arthrodesis or osteotomy were included. Patients
self-reported their smoking status and were classified as: ‘never
smoked’ (61 patients), ‘ex-smoker’ (46 patients), or ‘current smoker’ (20
patients). Urine samples were analysed with cotinine assays and
cotinine dipstick tests.Aims
Patients and Methods
The aim of our study was to describe the characteristics,
treatment, and outcomes of patients with periprosthetic joint infection
(PJI) and normal inflammatory markers after total knee arthroplasty
(TKA) and total hip arthroplasty (THA). In total 538 TKAs and 414 THAs underwent surgical treatment for
PJI and met the inclusion criteria. Pre-operative erythrocyte sedimentation
rate (ESR) and C-reactive protein level (CRP) were reviewed to identify
the seronegative cohort. An age- and gender-matched cohort was identified
from the remaining patients for comparison. Overall, 4% of confirmed
infections were seronegative (21 TKA and 17 THA). Of those who underwent
pre-operative aspiration, cultures were positive in 76% of TKAs
(n = 13) and 64% of THAs (n = 7). Cell count and differential were
suggestive of infection in 85% of TKA (n = 11) and all THA aspirates
(n = 5). The most common organism was coagulase-negative Cite this article:
The purpose of this study was to compare the joint space width between one-leg and both-legs standing radiographs in order to diagnose a primary osteoarthritis of the knee. Digital radiographs of 100 medial osteoarthritic knees in 50 patients were performed. The patients had undergone one-leg standing anteroposterior (AP) views by standing on the affected leg while a both-legs standing AP view was undertaken while standing on both legs. The severity of the osteoarthritis was evaluated using the joint space width and Kellgren-Lawrence (KL) radiographic classification. The Objectives
Methods
We investigated whether blood metal ion levels could effectively
identify patients with bilateral Birmingham Hip Resurfacing (BHR)
implants who have adverse reactions to metal debris (ARMD). Metal ion levels in whole blood were measured in 185 patients
with bilateral BHRs. Patients were divided into those with ARMD
who either had undergone a revision for ARMD or had ARMD on imaging
(n = 30), and those without ARMD (n = 155). Receiver operating characteristic
analysis was used to determine the optimal thresholds of blood metal
ion levels for identifying patients with ARMD.Aims
Patients and Methods
Our aim was to investigate the predictive factors for the development
of a rebound phenomenon after temporary hemiepiphysiodesis in children
with genu valgum. We studied 37 limbs with idiopathic genu valgum who were treated
with hemiepiphyseal stapling, and with more than six months remaining
growth at removal of the staples. All children were followed until
skeletal maturity or for more than two years after removal of the
staples.Aims
Patients and Methods
This non-blinded randomised controlled trial compared the effect
of patient-controlled epidural analgesia (PCEA) A total of 242 patients were randomised; 20 were excluded due
to failure of spinal anaesthesia leaving 109 patients in the PCEA
group and 113 in the LIA group. Patients were reviewed at six weeks
and one year post-operatively.Aims
Patients and Methods
There is a paucity of information on the pre-operative coronal
imbalance in patients with degenerative lumbar scoliosis (DLS) and
its influence on surgical outcomes. A total of 284 DLS patients were recruited into this study, among
whom 69 patients were treated surgically and the remaining 215 patients
conservatively Patients were classified based on the coronal balance
distance (CBD): Type A, CBD <
3 cm; Type B, CBD >
3 cm and C7
Plumb Line (C7PL) shifted to the concave side of the curve; Type
C, CBD >
3 cm and C7PL shifted to the convex side.Aims
Patients and Methods
We compared the incidence of pseudotumours after
large head metal-on-metal (MoM) total hip arthroplasty (THA) with
that after conventional metal-on-polyethylene (MoP) THA and assessed
the predisposing factors to pseudotumour formation. From a previous randomised controlled trial which compared large
head (38 mm to 60 mm) cementless MoM THA with conventional head
(28 mm) cementless MoP THA, 93 patients (96 THAs: 41 MoM (21 males,
20 females, mean age of 64 years, standard deviation ( The incidence of pseudotumours, measured using a standardised
CT protocol was 22 (53.7%) after MoM THA and 12 (21.8%) after MoP
THA. Women with a MoM THA were more likely to develop a pseudotumour
than those with a MoP THA (15 Contrary to popular belief, pseudotumours occur frequently around
MoP THAs. Women with a MoM THA and an elevated cobalt level are
at greatest risk. In this study, pseudotumours had no effect on
the functional outcome after either large head MoM or conventional
MoP THA. Cite this article:
Circulating exosomes represent novel biomarkers for multiple diseases. In this study, we investigated whether circulating exosome levels could be used as a diagnostic biomarker for steroid-induced osteonecrosis of the femoral head (ONFH). We assessed the serum exosome level of 85 patients with steroid-induced ONFH and 115 healthy donors by Nanosight detection. We then assessed the diagnostic accuracy of serum exosomes by receiver operating characteristic curve analysis.Objectives
Methods
A high radiographic inclination angle (RI) contributes
to accelerated wear and has been associated with dislocation after
total hip arthroplasty (THA). With freehand positioning of the acetabular
component there is a lack of accuracy, with a trend towards a high
radiographic inclination angle. The aim of this study was to investigate
whether the use of a digital protractor to measure the operative
inclination angle (OI) could improve the positioning of the acetabular
component in relation to a ‘safe zone’. We measured the radiographic inclination angles of 200 consecutive
uncemented primary THAs. In the first 100 the component was introduced
freehand and in the second 100 a digital protractor was used to
measure the operative inclination angle. The mean difference between the operative and the radiographic
inclination angles
(∆RI–OI) in the second cohort was 12.3° (3.8° to 19.8°). There was
a strong correlation between the circumference of the hip and ∆RI–OI.
The number of RI outliers was significantly reduced in the protractor
group (p = 0.002). Adjusting the OI, using a digital protractor and taking into
account the circumference of the patient’s hip, improves the RI
significantly (p <
0.001) and does not require additional operating
time. Cite this article:
Excessive acetabular coverage is the most common cause of pincer-type
femoroacetabular impingement. To date, an association between acetabular
over-coverage and genetic variations has not been studied. In this
study we investigated the association between single nucleotide
polymorphisms (SNPs) of paralogous Homeobox (HOX)9 genes and acetabular
coverage in Japanese individuals to identify a possible genetic
variation associated with acetabular over-coverage. We investigated 19 total SNPs in the four HOX9 paralogs, then
focused in detail on seven of those located in the 3’ untranslated
region of Objectives
Methods
We report patient-reported outcomes and complications
associated with contemporary periacetabular osteotomy (PAO) surgery
in treating symptomatic acetabular dysplasia and compare these outcomes
with total hip arthroplasty (THA) in patients with similar demographic
details. Two consecutive cohorts included patients between aged
18 to 40 years who had undergone either PAO (100 hips; 24 male,
76 female) or THA (55 hips; 18 male, 37 female). At a mean follow-up
of 5.9 years (2 to 13), there was significant improvement in the
modified Harris hip pain (p <
0.001, PAO and p <
0.001, THA),
function (p <
0.001, PAO and p = 0.001, THA), and total scores
(p <
0.001, PAO and p <
0.001, THA) within each cohort. There
were no significant differences in the clinical outcome scores between
the groups. Complication rates were low and similar in each cohort
(p = 0.68). Similar to THA, contemporary PAO surgery is a clinically
effective procedure that improves function and activity levels,
provides pain relief and is associated with an acceptable complication
rate. Cite this article:
This study aimed to characterise and qualitatively grade the severity of the corrosion particles released into the hip joint following taper corrosion. The 26 cases examined were CoC/ABG Modular (n = 13) and ASR/SROM (n = 13). Blood serum metal ion levels were collected before and after revision surgery. The haematoxylin and eosin tissue sections were graded on the presence of fibrin exudates, necrosis, inflammatory cells and corrosion products. The corrosion products were identified based on visible observation and graded on abundance. Two independent observers blinded to the clinical patient findings scored all cases. Elemental analysis was performed on corrosion products within tissue sections. X-Ray diffraction was used to identify crystalline structures present in taper debris.Objectives
Methods
When fracture of an extensively porous-coated
femoral component occurs, its removal at revision total hip arthroplasty
(THA) may require a femoral osteotomy and the use of a trephine.
The remaining cortical bone after using the trephine may develop
thermally induced necrosis. A retrospective review identified 11
fractured, well-fixed, uncemented, extensively porous-coated femoral
components requiring removal using a trephine with a minimum of
two years of follow-up. The mean time to failure was 4.6 years (1.7 to 9.1, standard
deviation ( A total of four patients (36.4%) required further revision: three
for instability and one for fracture of the revision component.
There was no statistically significant difference in the mean Harris
hip score before implant fracture (82.4; These findings suggest that removal of a fractured, well-fixed,
uncemented, extensively porous-coated femoral component using a
trephine does not compromise subsequent fixation at revision THA
and the patient’s pre-operative level of function can be restored.
However, the loss of proximal bone stock before revision may be associated
with a high rate of dislocation post-operatively. Cite this article: