A new method of demonstrating sagittal laxity in the anterior cruciate-deficient knee is described. Seventy such knees were compared to 70 normal knees. Sagittal laxity was recorded as the average displacement of the medial and lateral femoral condyles. This displacement index was significantly different between the two groups of knees (P less than 0.0001). A range for normal and abnormal knees is discussed. Quantitative
Different criteria for assessing the reduction quality of trochanteric fractures have been reported. The Baumgaertner reduction quality criteria (BRQC) are relatively common and the Chang reduction quality criteria (CRQC) are relatively new. The objectives of the current study were to compare the reliability of the BRQC and CRQC in predicting mechanical complications and to investigate the clinical implications of the CRQC. A total of 168 patients were assessed in a retrospective observational study. Clinical information including age, sex, fracture side, American Society of Anesthesiologists (ASA) classification, tip-apex distance (TAD), fracture classification, reduction quality, blade position, BRQC, CRQC, bone quality, and the occurrence of mechanical complications were used in the statistical analysis.Objectives
Methods
We investigated the epidemiology,
1. The various methods of assessing the results of hip arthroplasties have been investigated. 2. The different results obtained by using different methods are very significant. 3. The importance of achieving a generally agreed
Objectives. The purpose of this study was to clarify the appearance of the reparative tissue on the articular surface and to analyse the properties of the reparative tissue after hemicallotasis osteotomy (HCO) using MRI T1ρ and T2 mapping. Methods. Coronal T1ρ and T2 mapping and three-dimensional gradient-echo images were obtained from 20 subjects with medial knee osteoarthritis. We set the regions of interest (ROIs) on the full-thickness cartilage of the medial femoral condyle (MFC) and medial tibial plateau (MTP) of the knee and measured the cartilage thickness (mm) and T1ρ and T2 relaxation times (ms). Statistical analysis of time-dependent changes in the cartilage thickness and the T1ρ and T2 relaxation times was performed using one-way analysis of variance, and Scheffe’s test was employed for post hoc multiple comparison. Results. The cartilage-like repair tissue appeared on the cartilage surface of the medial compartment post-operatively, and the cartilage thickness showed a significant increase between the pre-operative and one-year post-operative time points (MFC; p = 0.003, MTP; p < 0.001). The T1ρ values of the cartilage-like repair tissue showed no difference over time, however, the T2 values showed a significant decrease between the pre-operative and one-year post-operative time points (MFC; p = 0.004, MTP; p = 0.040). Conclusion. This study clarified that the fibrocartilage-like repair tissue appeared on the articular surface of the medial compartment after HCO as evidenced by MRI T1ρ and T2 mapping. Cite this article: H. Nishioka, E. Nakamura, J. Hirose, N. Okamoto, S. Yamabe, H. Mizuta. MRI T1ρ and T2 mapping for the
Four patients with pectoralis major ruptures underwent clinical and dynamometric
Relapsed congenital talipes equinovarus is difficult to assess and treat. Pedobarography provides dynamic measurement of the pressures under the foot, and may be used in the
Thirty-six patients with 39 fresh fractures of the calcaneus were investigated by standard radiography and by computerised tomography. It was found that the size and disposition of the fracture fragments and the degree of involvement of the posterior facet of the subtalar joint were more clearly shown by CT scanning. We recommend this technique for
One-hundred newborn children at high risk of hip instability were prospectively assessed clinically and by ultrasound. The decision to treat was based only on the clinical examination. At the age of three months all the children were evaluated clinically and with an anteroposterior radiograph of the pelvis. None of the standard ultrasound measurements of acetabular depth and femoral head cover correlated with the outcome at three months. Dynamic
The gait pattern of five amputees was recorded by visual observation and also by a quantitative measurement system. The results were compared with the gait pattern predicted from biomechanical analysis. Visual observation was found to be an unreliable clinical skill. The observers recorded only 22.2% of the predicted gait deviations and were unable to comment on 15.6% of all the required observations. The gait parameters which were difficult to assess visually, namely step length and step time, are considered by most workers to be of particular value as diagnostic clinical indicators in gait
Objectives. Computed tomography (CT) plays an important role in evaluating wear and periacetabular osteolysis (PAO) in total hip replacements. One concern with CT is the high radiation exposure since standard pelvic CT provides approximately 3.5 millisieverts (mSv) of radiation exposure, whereas a planar radiographic examination with three projections totals approximately 0.5 mSv. The objective of this study was to evaluate the lowest acceptable radiation dose for dual-energy CT (DECT) images when measuring wear and periacetabular osteolysis in uncemented metal components. Materials and Methods. A porcine pelvis with bilateral uncemented hip prostheses and with known linear wear and acetabular bone defects was examined in a third-generation multidetector DECT scanner. The examinations were performed with four different radiation levels both with and without iterative reconstruction techniques. From the high and low peak kilo voltage acquisitions, polychrmoatic images were created together with virtual monochromatic images of energies 100 kiloelectron volts (keV) and 150 keV. Results. We could assess wear and PAO while substantially lowering the effective radiation dose to 0.7 mSv for a total pelvic view with an accuracy of around 0.5 mm for linear wear and 2 mm to 3 mm for PAO. Conclusion. CT for detection of prosthetic wear and PAO could be used with clinically acceptable accuracy at a radiation exposure level equal to plain radiographic exposures. Cite this article: B. Sandgren, M. Skorpil, P. Nowik, H. Olivecrona, J. Crafoord, L. Weidenhielm, A. Persson.
Objectives. This study aims to assess the correlation of CT-based structural
rigidity analysis with mechanically determined axial rigidity in
normal and metabolically diseased rat bone. Methods. A total of 30 rats were divided equally into normal, ovariectomized,
and partially nephrectomized groups. Cortical and trabecular bone
segments from each animal underwent micro-CT to assess their average
and minimum axial rigidities using structural rigidity analysis.
Following imaging, all specimens were subjected to uniaxial compression
and
The responsiveness of the Manchester–Oxford Foot
Questionnaire (MOXFQ) was compared with foot/ankle-specific and
generic outcome measures used to assess all surgery of the foot
and ankle. We recruited 671 consecutive adult patients awaiting
foot or ankle surgery, of whom 427 (63.6%) were female, with a mean
age of 52.8 years (18 to 89). They independently completed the MOXFQ,
Short-Form 36 (SF-36) and EuroQol (EQ-5D) questionnaires pre-operatively
and at a mean of nine months (3.8 to 14.4) post-operatively. Foot/ankle
surgeons assessed American Orthopaedic Foot and Ankle Society (AOFAS)
scores corresponding to four foot/ankle regions. A transition item measured
perceived changes in foot/ankle problems post-surgery. Of 628 eligible
patients proceeding to surgery, 491 (78%) completed questionnaires
and 262 (42%) received clinical
A simple method of radiological
Routine ultrasound evaluation of neonates and young infants for congenital dislocation of the hip has been recommended. We have used the methods of decision analysis to determine whether every neonate should be examined by ultrasound or just those at increased risk. We have also studied the reliability and accuracy of ultrasound in following infants during observation and treatment, using published data. We find that ultrasound is not the preferred strategy for the screening of neonates, and that its role in evaluating high-risk patients depends on the point of view. For an individual, when third parties are bearing the cost, ultrasound is useful. For society as a whole, the routine ultrasound evaluation of the high-risk patient is not advantageous. For follow-up, ultrasound using the methods of Graf has a low reliability and there are no adequate data for methods using dynamic
In an unselected series of 55 cases of slipped capital femoral epiphysis (SCFE) we observed an incidence of 25% of epiphyseal reduction, mostly unintentional. Reduction indicated physeal instability and was associated with an effusion, detected by sonography on admission, and inability to bear weight. The true prevalence of instability may be higher since an effusion was noted in 33 cases (60%) on the initial sonographic
1. Radiological, chemical and histological examinations have been made of the lumbar vertebral bodies in 100 necropsies on patients dying in a general hospital, with a view to determining the range of variation of calcium content and radiographic density in normal and osteoporotic bone. 2. Radiographs were made of sagittal mid-line vertebral body slabs uniformly one centimetre in thickness, and the radiographic density of these specimens was measured in relation to an aluminium step-wedge of one to ten units. Radio-opacity of different vertebrae ranged from four to ten units. The specimen radiographs also clearly revealed the trabecular structure and the lateral profile of the bones. 3. Calcium was chemically estimated and expressed as weight of the element per unit volume of the whole bone mass (that is, of anatomical bone including soft marrow tissue). It ranged from 38 to 102 milligrams per cubic centimetre of bone. In 75 per cent of the cases the range was 50-84 milligrams per cubic centimetre. High calcium values were mostly encountered in young adults, and the calcium per unit volume tended to diminish with age; but a wide range of calcium was still encountered in the older subjects and a better correlation with age was achieved by radiographic density. Both calcium content and radiographic density tended to be higher in the male than in the female bones at all ages. 4. The results of both calcium and radiographic density showed a smooth distribution curve, though skewed through the inclusion in the series of more older people with less mineralised bones; the absence of a double peak in these curves suggests that the examinations were made on a homogeneous population and does not indicate a separate pathological group of osteoporotic subjects. 5. Arbitrary standards must be used to distinguish osteoporotic from normal bones, since neither radiological measurement or chemical assay, nor histological
The objectives of this study were to compare postoperative pain, analgesia requirements, inpatient functional rehabilitation, time to hospital discharge, and complications in patients undergoing conventional jig-based unicompartmental knee arthroplasty (UKA) This prospective cohort study included 146 patients with symptomatic medial compartment knee osteoarthritis undergoing primary UKA performed by a single surgeon. This included 73 consecutive patients undergoing conventional jig-based mobile bearing UKA, followed by 73 consecutive patients receiving robotic-arm assisted fixed bearing UKA. All surgical procedures were performed using the standard medial parapatellar approach for UKA, and all patients underwent the same postoperative rehabilitation programme. Postoperative pain scores on the numerical rating scale and opiate analgesia consumption were recorded until discharge. Time to attainment of predefined functional rehabilitation outcomes, hospital discharge, and postoperative complications were recorded by independent observers.Aims
Patients and Methods
The aim of this study was to compare the design of the generic
OptiStem XTR femoral stem with the established Exeter femoral stem. We obtained five boxed, as manufactured, implants of both designs
at random (ten in total). Two examiners were blinded to the implant
design and independently measured the mass, volume, trunnion surface
topography, trunnion roughness, trunnion cone angle, Caput-Collum-Diaphyseal
(CCD) angle, femoral offset, stem length, neck length, and the width
and roughness of the polished stem shaft using peer-reviewed methods.
We then compared the stems using these parameters.Aims
Materials and Methods
The glenopolar angle assesses the rotational
alignment of the glenoid and may provide prognostic information
and aid the management of scapula fractures. We have analysed the
effect of the anteroposterior (AP) shoulder radiograph rotational
offset on the glenopolar angle in a laboratory setting and used
this to assess the accuracy of shoulder imaging employed in routine
clinical practice. Fluoroscopic imaging was performed on 25 non-paired scapulae
tagged with 2 mm steel spheres to determine the orientation of true
AP views. The glenopolar angle was measured on all the bony specimens
rotated at 10° increments. The mean glenopolar angle measured on
the bone specimens in rotations between 0° and 20° and thereafter
was found to be significantly different (p <
0.001). We also obtained
the AP radiographs of the uninjured shoulder of 30 patients treated
for fractures at our centre and found that none fitted the criteria
of a true AP shoulder radiograph. The mean angular offset from the
true AP view was 38° (10° to 65°) for this cohort. Radiological
AP shoulder views may not fully project the normal anatomy of the scapular
body and the measured glenopolar angle. The absence of a true AP
view may compromise the clinical management of a scapular fracture. Cite this article: