Advertisement for orthosearch.org.uk
Results 81 - 100 of 566
Results per page:
Bone & Joint Open
Vol. 1, Issue 3 | Pages 29 - 34
13 Mar 2020
Stirling P Middleton SD Brenkel IJ Walmsley PJ

Introduction. The primary aim of this study was to describe a baseline comparison of early knee-specific functional outcomes following revision total knee arthroplasty (TKA) using metaphyseal sleeves with a matched cohort of patients undergoing primary TKA. The secondary aim was to compare incidence of complications and length of stay (LOS) between the two groups. Methods. Patients undergoing revision TKA for all diagnoses between 2009 and 2016 had patient-reported outcome measures (PROMs) collected prospectively. PROMs consisted of the American Knee Society Score (AKSS) and Short-Form 12 (SF-12). The study cohort was identified retrospectively and demographics were collected. The cohort was matched to a control group of patients undergoing primary TKA. Results. Overall, 72 patients underwent revision TKA and were matched with 72 primary TKAs with a mean follow-up of 57 months (standard deviation (SD) 20 months). The only significant difference in postoperative PROMs was a worse AKSS pain score in the revision group (36 vs 44, p = 0.002); however, these patients still produced an improvement in the pain score. There was no significant difference in improvement of AKSS or SF-12 between the two groups. LOS (9.3 days vs 4.6 days) and operation time (1 hour 56 minutes vs 1 hour 7 minutes) were significantly higher in the revision group (p < 0.001). Patients undergoing revision were significantly more likely to require intraoperative lateral release and postoperative urinary catheterisation (p < 0.001). Conclusion. This matched-cohort study provides results of revision TKA using modern techniques and implants and outlines what results patients can expect to achieve using primary TKA as a control. This should be useful to clinicians counselling patients for revision TKA


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1089 - 1095
21 Dec 2021
Luo W Ali MS Limb R Cornforth C Perry DC

Aims. The Patient-Reported Outcomes Measurement Information System (PROMIS) has demonstrated faster administration, lower burden of data capture and reduced floor and ceiling effects compared to traditional Patient Reported Outcomes Measurements (PROMs). We investigated the suitability of PROMIS Mobility score in assessing physical function in the sequelae of childhood hip disease. Methods. In all, 266 adolscents (aged ≥ 12 years) and adults were identified with a prior diagnosis of childhood hip disease (either Perthes’ disease (n = 232 (87.2%)) or Slipped Capital Femoral Epiphysis (n = 34 (12.8%)) with a mean age of 27.73 years (SD 12.24). Participants completed the PROMIS Mobility Computer Adaptive Test, the Non-Arthritic Hip Score (NAHS), EuroQol five-dimension five-level questionnaire, and the Numeric Pain Rating Scale. We investigated the correlation between the PROMIS Mobility and other tools to assess use in this population and any clustering of outcome scores. Results. There was a strong correlation between the PROMIS Mobility and other established PROMs; NAHS (rs = 0.79; p < 0.001). There was notable clustering in PROMIS at the upper end of the distribution score (42.5%), with less seen in the NAHS (20.3%). However, the clustering was broadly similar between PROMIS Mobility and the comparable domains of the NAHS; function (53.6%), and activity (35.0%). Conclusion. PROMIS Mobility strongly correlated with other tools demonstrating convergent construct validity. There was clustering of physical function scores at the upper end of the distributions, which may reflect truncation of the data caused by participants having excellent outcomes. There were elements of disease not captured within PROMIS Mobility alone, and difficulties in differentiating those with the highest levels of function. Cite this article: Bone Jt Open 2021;2(12):1089–1095


Bone & Joint Research
Vol. 5, Issue 4 | Pages 153 - 161
1 Apr 2016
Kleinlugtenbelt YV Nienhuis RW Bhandari M Goslings JC Poolman RW Scholtes VAB

Objectives. Patient-reported outcome measures (PROMs) are often used to evaluate the outcome of treatment in patients with distal radial fractures. Which PROM to select is often based on assessment of measurement properties, such as validity and reliability. Measurement properties are assessed in clinimetric studies, and results are often reviewed without considering the methodological quality of these studies. Our aim was to systematically review the methodological quality of clinimetric studies that evaluated measurement properties of PROMs used in patients with distal radial fractures, and to make recommendations for the selection of PROMs based on the level of evidence of each individual measurement property. Methods. A systematic literature search was performed in PubMed, EMbase, CINAHL and PsycINFO databases to identify relevant clinimetric studies. Two reviewers independently assessed the methodological quality of the studies on measurement properties, using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. Level of evidence (strong / moderate / limited / lacking) for each measurement property per PROM was determined by combining the methodological quality and the results of the different clinimetric studies. Results. In all, 19 out of 1508 identified unique studies were included, in which 12 PROMs were rated. The Patient-rated wrist evaluation (PRWE) and the Disabilities of Arm, Shoulder and Hand questionnaire (DASH) were evaluated on most measurement properties. The evidence for the PRWE is moderate that its reliability, validity (content and hypothesis testing), and responsiveness are good. The evidence is limited that its internal consistency and cross-cultural validity are good, and its measurement error is acceptable. There is no evidence for its structural and criterion validity. The evidence for the DASH is moderate that its responsiveness is good. The evidence is limited that its reliability and the validity on hypothesis testing are good. There is no evidence for the other measurement properties. Conclusion. According to this systematic review, there is, at best, moderate evidence that the responsiveness of the PRWE and DASH are good, as are the reliability and validity of the PRWE. We recommend these PROMs in clinical studies in patients with distal radial fractures; however, more clinimetric studies of higher methodological quality are needed to adequately determine the other measurement properties. Cite this article: Dr Y. V. Kleinlugtenbelt. Are validated outcome measures used in distal radial fractures truly valid?: A critical assessment using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. Bone Joint Res 2016;5:153–161. DOI: 10.1302/2046-3758.54.2000462


Bone & Joint Open
Vol. 2, Issue 7 | Pages 454 - 465
8 Jul 2021
Kristoffersen MH Dybvik EH Steihaug OM Kristensen TB Engesæter LB Ranhoff AH Gjertsen J

Aims. Hip fracture patients have high morbidity and mortality. Patient-reported outcome measures (PROMs) assess the quality of care of patients with hip fracture, including those with chronic cognitive impairment (CCI). Our aim was to compare PROMs from hip fracture patients with and without CCI, using the Norwegian Hip Fracture Register (NHFR). Methods. PROM questionnaires at four months (n = 34,675) and 12 months (n = 24,510) after a hip fracture reported from 2005 to 2018 were analyzed. Pre-injury score was reported in the four-month questionnaire. The questionnaires included the EuroQol five-dimension three-level (EQ-5D-3L) questionnaire, and information about who completed the questionnaire. Results. Of the 34,675 included patients, 5,643 (16%) had CCI. Patients with CCI were older (85 years vs 81 years) (p < 0.001), and had a higher American Society of Anesthesiologists (ASA) classification compared to patients without CCI. CCI was unrelated to fracture type and treatment method. EQ-5D index scores were lower in patients with CCI after four months (0.37 vs 0.60; p < 0.001) and 12 months (0.39 vs 0.64; p < 0.001). Patients with CCI had lower scores for all dimensions of the EQ-5D-3L pre-fracture and at four and 12 months. Conclusion. Patients with CCI reported lower health-related quality of life pre-fracture, at four and 12 months after the hip fracture. PROM data from hip fracture patients with CCI are valuable in the assessment of treatment. Patients with CCI should be included in future studies. Cite this article: Bone Jt Open 2021;2(7):454–465


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1329 - 1334
1 Oct 2017
Lim JBT Chong HC Pang HN Tay KJD Chia SL Lo NN Yeo SJ

Aims. Little is known about the relative outcomes of revision of unicompartmental knee arthroplasty (UKA) and high tibial osteotomy (HTO) to total knee arthroplasty (TKA). The aim of this study is to compare the outcomes of revision surgery for the two procedures in terms of complications, re-revision and patient-reported outcome measures (PROMs) at a minimum of two years follow-up. Patients and Methods. This study was a retrospective review of data from an institutional arthroplasty registry for cases performed between 2001 and 2014. A total of 292 patients were identified, of which 217 had a revision of HTO to TKA, and 75 had revision of UKA to TKA. While mean follow-up was longer for the HTO group compared with the UKA group, patient demographics (age, body mass index and Charlson co-morbidity index) and PROMs (Short Form-36, Oxford Knee Score, Knee Society Score, both objective and functional) were similar in the two groups prior to revision surgery. Outcomes included the rate of complications and re-operation, PROMS and patient-reported satisfaction at six months and two years post-operatively. We also compared the duration of surgery and the need for revision implants in the two groups. . Results . At two-year follow-up, both groups of patients had made significant improvement in terms of PROMs compared with pre-operative scores. PROMs and satisfaction rates were similar in the two groups. Complications requiring re-operation were significantly more frequent in the HTO group whilst more revision implants were used in the UKA group, resulting in a longer operative duration. . Conclusion. Revision of HTO and UKA achieve similar post-operative PROMs and satisfaction. Revision of UKA more frequently requires revision components with increased operation duration but fewer complications requiring re-operation compared with revision of HTO. . Cite this article: Bone Joint J 2017;99-B:1329–34


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1514 - 1525
1 Sep 2021
Scott CEH Holland G Gillespie M Keenan OJ Gherman A MacDonald DJ Simpson AHRW Clement ND

Aims. The aims of this study were to investigate the ability to kneel after total knee arthroplasty (TKA) without patellar resurfacing, and its effect on patient-reported outcome measures (PROMs). Secondary aims included identifying which kneeling positions were most important to patients, and the influence of radiological parameters on the ability to kneel before and after TKA. Methods. This prospective longitudinal study involved 209 patients who underwent single radius cruciate-retaining TKA without patellar resurfacing. Preoperative EuroQol five-dimension questionnaire (EQ-5D), Oxford Knee Score (OKS), and the ability to achieve four kneeling positions were assessed including a single leg kneel, a double leg kneel, a high-flexion kneel, and a praying position. The severity of radiological osteoarthritis (OA) was graded and the pattern of OA was recorded intraoperatively. The flexion of the femoral component, posterior condylar offset, and anterior femoral offset were measured radiologically. At two to four years postoperatively, 151 patients with a mean age of 70.0 years (SD 9.44) were included. Their mean BMI was 30.4 kg/m. 2. (SD 5.36) and 60 were male (40%). They completed EQ-5D, OKS, and Kujala scores, assessments of the ability to kneel, and a visual analogue scale for anterior knee pain and satisfaction. Results. The ability to kneel in the four positions improved in between 29 (19%) and 53 patients (35%) after TKA, but declined in between 35 (23%) and 46 patients (30%). Single-leg kneeling was most important to patients. After TKA, 62 patients (41%) were unable to achieve a single-leg kneel, 76 (50%) were unable to achieve a double-leg kneel, 102 (68%) were unable to achieve a high-flexion kneel and 61 (40%) were unable to achieve a praying position. Posterolateral cartilage loss significantly affected preoperative deep flexion kneeling (p = 0.019). A postoperative inability to kneel was significantly associated with worse OKS, Kujala scores, and satisfaction (p < 0.05). Multivariable regression analysis identified significant independent associations with the ability to kneel after TKA (p < 0.05): better preoperative EQ-5D and flexion of the femoral component for single-leg kneeling; the ability to achieve it preoperatively and flexion of the femoral component for double-leg kneeling; male sex for high-flexion kneeling; and the ability to achieve it preoperatively, anterior femoral offset, and patellar cartilage loss for the praying position. Conclusion. The ability to kneel was important to patients and significantly influenced knee-specific PROMs, but was poorly restored by TKA with equal chances of improvement or decline. Cite this article: Bone Joint J 2021;103-B(9):1514–1525


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1058 - 1066
1 Aug 2012
Baker PN Deehan DJ Lees D Jameson S Avery PJ Gregg PJ Reed MR

Patient-reported outcome measures (PROMs) are increasingly being used to assess functional outcome and patient satisfaction. They provide a framework for comparisons between surgical units, and individual surgeons for benchmarking and financial remuneration. Better performance may bring the reward of more customers as patients and commissioners seek out high performers for their elective procedures. Using National Joint Registry (NJR) data linked to PROMs we identified 22 691 primary total knee replacements (TKRs) undertaken for osteoarthritis in England and Wales between August 2008 and February 2011, and identified the surgical factors that influenced the improvements in the Oxford knee score (OKS) and EuroQol-5D (EQ-5D) assessment using multiple regression analysis. After correction for patient factors the only surgical factors that influenced PROMs were implant brand and hospital type (both p < 0.001). However, the effects of surgical factors upon the PROMs were modest compared with patient factors. For both the OKS and the EQ-5D the most important factors influencing the improvement in PROMs were the corresponding pre-operative score and the patient’s general health status. Despite having only a small effect on PROMs, this study has shown that both implant brand and hospital type do influence reported subjective functional scores following TKR. In the current climate of financial austerity, proposed performance-based remuneration and wider patient choice, it would seem unwise to ignore these effects and the influence of a range of additional patient factors


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 760 - 767
1 Jul 2019
Galea VP Rojanasopondist P Laursen M Muratoglu OK Malchau H Bragdon C

Aims. Vitamin E-diffused, highly crosslinked polyethylene (VEPE) and porous titanium-coated (PTC) shells were introduced in total hip arthroplasty (THA) to reduce the risk of aseptic loosening. The purpose of this study was: 1) to compare the wear properties of VEPE to moderately crosslinked polyethylene; 2) to assess the stability of PTC shells; and 3) to report their clinical outcomes at seven years. Patients and Methods. A total of 89 patients were enrolled into a prospective study. All patients received a PTC shell and were randomized to receive a VEPE liner (n = 44) or a moderately crosslinked polyethylene (ModXLPE) liner (n = 45). Radiostereometric analysis (RSA) was used to measure polyethylene wear and component migration. Differences in wear were assessed while adjusting for body mass index, activity level, acetabular inclination, anteversion, and head size. Plain radiographs were assessed for radiolucency and patient-reported outcome measures (PROMs) were administered at each follow-up. Results. In total, 73 patients (82%) completed the seven-year visit. Mean seven-year linear proximal penetration was -0.07 mm (. sd. 0.16) and 0.00 mm (. sd. 0.22) for the VEPE and ModXLPE cohorts, respectively (p = 0.116). PROMs (p = 0.310 to 0.807) and radiolucency incidence (p = 0.330) were not different between the polyethylene cohorts. The mean proximal shell migration rate was 0.04 mm per year (. sd. 0.09). At seven years, patients with radiolucency (34%) demonstrated greater migration (mean difference: 0.6 mm (. sd. 0.2); p < 0.001). PROMs were lower for patients with radiolucency and greater proximal migration (p = 0.009 to p = 0.045). No implants were revised for aseptic loosening. Conclusion. This is the first randomized controlled trial to report seven-year RSA results for VEPE. All wear rates were below the previously reported osteolysis threshold (0.1 mm per year). PTC shells demonstrated acceptable primary stability through seven years, as indicated by low migration and lack of aseptic loosening. However, patients with acetabular radiolucency were associated with higher shell migration and lower PROM scores. Cite this article: Bone Joint J 2019;101-B:760–767


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1049 - 1056
1 Dec 2021
Shields DW Razii N Doonan J Mahendra A Gupta S

Aims. The primary objective of this study was to compare the postoperative infection rate between negative pressure wound therapy (NPWT) and conventional dressings for closed incisions following soft-tissue sarcoma (STS) surgery. Secondary objectives were to compare rates of adverse wound events and functional scores. Methods. In this prospective, single-centre, randomized controlled trial (RCT), patients were randomized to either NPWT or conventional sterile occlusive dressings. A total of 17 patients, with a mean age of 54 years (21 to 81), were successfully recruited and none were lost to follow-up. Wound reviews were undertaken to identify any surgical site infection (SSI) or adverse wound events within 30 days. The Toronto Extremity Salvage Score (TESS) and Musculoskeletal Tumor Society (MSTS) score were recorded as patient-reported outcome measures (PROMs). Results. There were two out of seven patients in the control group (28.6%), and two out of ten patients in the intervention group (20%) who were diagnosed with a SSI (p > 0.999), while one additional adverse wound event was identified in the control group (p = 0.593). No significant differences in PROMs were identified between the groups at either 30 days (TESS, p = 0.987; MSTS, p = 0.951) or six-month (TESS, p = 0.400) follow-up. However, neoadjuvant radiotherapy was significantly associated with a SSI within 30 days of surgery, across all patients (p = 0.029). The mean preoperative modified Glasgow Prognostic Score (mGPS) was also significantly higher among patients who developed a postoperative adverse wound event (p = 0.028), including a SSI (p = 0.008), across both groups. Conclusion. This is the first RCT comparing NPWT with conventional dressings following musculoskeletal tumour surgery. Postoperative wound complications are common in this group of patients and we observed an overall SSI rate of 23.5%. We propose proceeding to a multicentre trial, which will help more clearly define the role of closed incision NPWT in STS surgery. Cite this article: Bone Jt Open 2021;2(12):1049–1056


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 16 - 22
1 Jun 2019
Livermore AT Anderson LA Anderson MB Erickson JA Peters CL

Aims. The aim of this study was to compare patient-reported outcome measures (PROMs), radiological measurements, and total hip arthroplasty (THA)-free survival in patients who underwent periacetabular osteotomy (PAO) for mild, moderate, or severe developmental dysplasia of the hip. Patients and Methods. We performed a retrospective study involving 336 patients (420 hips) who underwent PAO by a single surgeon at an academic centre. After exclusions, 124 patients (149 hips) were included. The preoperative lateral centre-edge angle (LCEA) was used to classify the severity of dysplasia: 18° to 25° was considered mild (n = 20), 10° to 17° moderate (n = 66), and < 10° severe (n = 63). There was no difference in patient characteristics between the groups (all, p > 0.05). Pre- and postoperative radiological measurements were made. The National Institute of Health’s Patient Reported Outcomes Measurement Information System (PROMIS) outcome measures (physical function computerized adaptive test (PF CAT), Global Physical and Mental Health Scores) were collected. Failure was defined as conversion to THA or PF CAT scores < 40, and was assessed with Kaplan–Meier analysis. The mean follow-up was five years (2 to 10) ending in either failure or the latest contact with the patient. Results. There was no significant difference in PROMs for moderate (p = 0.167) or severe (p = 0.708) groups compared with the mild dysplasia group. The numerical pain scores were between 2 and 3 units in all groups at the final follow-up (all, p > 0.05). There was no significant difference (all, p > 0.05) in the proportion of patients achieving target correction for the LCEA between groups. The mean correction was 12° in the mild, 15° in the moderate (p = 0.135), and 23° in the severe group (p < 0.001). Failure-free survival at five years was 100% for mild, 79% for moderate, and 92% for severely dysplastic hips (p = 0.225). Conclusion. Although requiring less correction than hips with moderate or severe dysplasia, we found PAO for mild dysplasia to be associated with promising PROMs, consistent with that of the general United States population, and excellent survivorship at five years. Future studies should compare these results with the outcome after arthroscopy of the hip in patients with mild dysplasia. Cite this article: Bone Joint J 2019;101-B(6 Supple B):16–22


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 113 - 120
1 Jan 2019
Scholes CJ Ebrahimi M Farah SB Field C Cordingley R Kerr D Kohan L

Aims. The aim of this study was to report the implant survival and patient-reported outcome measures (PROMs) in a consecutive series of patients aged less than 50 years at the time of arthroplasty using the Birmingham Hip Resurfacing system (BHR), with a minimum follow-up of ten years. Patients and Methods. A total of 226 patients with osteoarthritis of the hip, who underwent BHR and presented to a single surgeon, were included in the study. Survival of the implant was confirmed by cross-checking with the Australian Orthopaedic Association National Joint Replacement Registry. Kaplan–Meier survival curves with 95% confidence intervals (CIs) were constructed. Pre- and postoperative PROMs were compared with t-tests, and postoperative scores were compared using anchor analysis with age and gender matched normative data. Results. At median follow-up of 12 years (interquartile range (IQR) 10 to 13), six BHRs were revised, with a cumulative rate of survival of 96.8% (95% confidence interval (CI) 94.2 to 99.4) at 15 years, and with a significantly lower (p = 0.019) cumulative rate of revision than the national average for the same device at ten years. Most revisions (n = 4) were undertaken early, less than three years postoperatively, and occurred in women. Patient-reported general health (Veteran’s Rand-36), disease state (Western Ontario and McMaster Universities Osteoarthritis Index), function (modified Harris Hip Score) and level of activity (Tegner activity score) maintained significant (p < 0.01 for each) improvements beyond ten years postoperatively and were equal to, or exceeded, age- and gender-matched normative data in more than 80% of the patients. Conclusion. Longer term PROMs after BHR, from a single surgeon, for patients aged less than 50 years remain under-reported. We found that the outcome after a BHR, at a minimum of ten years postoperatively, remained satisfactory, particularly for self-reported hip function


Bone & Joint Open
Vol. 2, Issue 5 | Pages 293 - 300
3 May 2021
Lewis PM Khan FJ Feathers JR Lewis MH Morris KH Waddell JP

Aims. “Get It Right First Time” (GIRFT) and NHS England’s Best Practice Tariff (BPT) have published directives advising that patients over the ages of 65 (GIRFT) and 69 years (BPT) receiving total hip arthroplasty (THA) should receive cemented implants and have brought in financial penalties if this policy is not observed. Despite this, worldwide, uncemented component use has increased, a situation described as a ‘paradox’. GIRFT and BPT do, however, acknowledge more data are required to support this edict with current policies based on the National Joint Registry survivorship and implant costs. Methods. This study compares THA outcomes for over 1,000 uncemented Corail/Pinnacle constructs used in all age groups/patient frailty, under one surgeon, with identical pre- and postoperative pathways over a nine-year period with mean follow-up of five years and two months (range: nine months to nine years and nine months). Implant information, survivorship, and regular postoperative Oxford Hip Scores (OHS) were collected and two comparisons undertaken: a comparison of those aged over 65 years with those 65 and under and a second comparison of those aged 70 years and over with those aged under 70. Results. Overall revision rate was 1.3% (13/1,004). A greater number of revisions were undertaken in those aged over 65 years, but numbers were small and did not reach significance. The majority of revisions were implant-independent. Single component analysis revealed a 99.9% and 99.6% survival for the uncemented cup and femoral component, respectively. Mean patient-reported outcome measures (PROMs) improvement for all ages outperformed the national PROMs and a significantly greater proportion of those aged over 65/69 years reached and maintained a meaningful improvement in their OHS earlier than their younger counterparts (p < 0.05/0.01 respectively). Conclusion. This study confirms that this uncemented THA system can be used safely and effectively in patient groups aged over 65 years and those over 69 years, with low complication and revision rates. Cite this article: Bone Jt Open 2021;2(5):293–300


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1592 - 1599
1 Dec 2018
Galea VP Connelly JW Shareghi B Kärrholm J Sköldenberg O Salemyr M Laursen MB Muratoglu O Bragdon C Malchau H

Aims. The primary aim of this study was to compare the wear properties of vitamin E-diffused, highly crosslinked polyethylene (VEPE) and one formulation of moderately crosslinked and mechanically annealed ultra-high molecular weight polyethylene (ModXLPE) in patients five years after primary total hip arthroplasty (THA). The secondary aim was to assess the clinical results of patients treated with VEPE by evaluating patient-reported outcome measures (PROMs), radiological evidence of fixation, and the incidence of mechanical failure. Patients and Methods. A total of 208 patients (221 THAs) from four international centres were recruited into a prospective study involving radiostereometric analysis (RSA) and the assessment of clinical outcomes. A total of 193 hips (87%) were reviewed at the five-year follow-up. Of these, 136 (70%) received VEPE (vs ModXLPE) liners and 68 (35%) received ceramic (vs metal) femoral heads. PROMs and radiographs were collected preoperatively and at one, two, and five years postoperatively. In addition, RSA images were collected to measure PE wear postoperatively and at one, two, and five years after surgery. Results. We observed similar bedding in one year postoperatively and wear two years postoperatively between the two types of liner. However, there was significantly more penetration of the femoral head in the ModXLPE cohort compared with the VEPE cohort five years postoperatively (p < 0.001). The only variables independently predictive of increased wear were ModXLPE (vs VEPE) liner type (β = 0.22, p = 0.010) and metal (vs ceramic) femoral head (β = 0.21, p = 0.013). There was no association between increased wear and the development of radiolucency (p = 0.866) or PROMs. No patient had evidence of osteolysis. Conclusion. Five years postoperatively, patients with VEPE (vs ModXLPE) and ceramic (vs metal) femoral heads had decreased wear. The rates of wear for both liners were very low and have not led to any osteolysis or implant failure due to aseptic loosening


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 536 - 541
1 Mar 2021
Ferlic PW Hauser L Götzen M Lindtner RA Fischler S Krismer M

Aims. The aim of this retrospective study was to compare the correction achieved using a convex pedicle screw technique and a low implant density achieved using periapical concave-sided screws and a high implant density. We hypothesized that there would be no difference in outcome between the two techniques. Methods. We retrospectively analyzed a series of 51 patients with a thoracic adolescent idiopathic scoliosis. There were 26 patients in the convex pedicle screw group who had screws implanted periapically (Group 2) and a control group of 25 patients with bilateral pedicle screws (Group 1). The patients’ charts were reviewed and pre- and postoperative radiographs evaluated. Postoperative patient-reported outcome measures (PROMs) were recorded. Results. The number of implants (14.5 vs 17.1) and the implant density (1.5 vs 1.9) were significantly lower in Group 2 (p < 0.001). Operating time was 27 minutes shorter in Group 2 than in Group 1, with a mean of 217 minutes (SD 50.5; 120 to 346). The duration of surgery per instrumented vertebra was reduced by 19% in Group 2 (p = 0.011). No statistical difference was found in the postoperative Cobb angle, vertebral rotation, the relative correction achieved, or postoperative PROMs. Conclusion. Despite a lower implant density and achieving correction through a convex rod, surgical correction of the Cobb angle and vertebral body rotation was similar in both groups. Periapical pedicle screws and primary correction on the concave side do not seem to be mandatory in order to achieve good surgical results in idiopathic thoracic scoliosis. The operating time was shorter in the group with lower implant density. In conclusion, the technique provided good results and has the potential to reduce complications and costs. Cite this article: Bone Joint J 2021;103-B(3):536–541


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 98 - 104
1 Jan 2021
van Ooij B Sierevelt IN van der Vis HM Hoornenborg D Haverkamp D

Aims. For many designs of total knee arthroplasty (TKA) it remains unclear whether cemented or uncemented fixation provides optimal long-term survival. The main limitation in most studies is a retrospective or non-comparative study design. The same is true for comparative trials looking only at the survival rate as extensive sample sizes are needed to detect true differences in fixation and durability. Studies using radiostereometric analysis (RSA) techniques have shown to be highly predictive in detecting late occurring aseptic loosening at an early stage. To investigate the difference in predicted long-term survival between cemented, uncemented, and hybrid fixation of TKA, we performed a randomized controlled trial using RSA. Methods. A total of 105 patients were randomized into three groups (cemented, uncemented, and hybrid fixation of the ACS Mobile Bearing (ACS MB) knee system, implantcast). RSA examinations were performed on the first day after surgery and at scheduled follow-up visits at three months, six months, one year, and two years postoperatively. Patient-reported outcome measures (PROMs) were obtained preoperatively and after two years follow-up. Patients and follow-up investigators were blinded for the result of randomization. Results. RSA secondary stabilization did not show a significant difference between the three types of fixation. A maximum total point motion of less than 0.2 mm in the second postoperative year was shown in each group, which suggests stabilization of the implant. At 24 months after surgery, PROMs significantly improved compared to baseline in all treatment groups. No significant difference was observed between the three groups. Conclusion. Secondary stabilization measurements in this study demonstrated no significant difference between the groups. In all groups migration stabilized after initial settling of the implant. For this implant the long-term outcome is not expected to be influenced by the type of fixation to the bone. Cite this article: Bone Joint J 2021;103-B(1):98–104


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1010 - 1015
1 Aug 2020
Robinson PG Maempel JF Murray IR Rankin CS Hamilton DF Gaston P

Aims. Responsiveness and ceiling effects are key properties of an outcome score. No such data have been reported for the original English version of the International Hip Outcome Tool 12 (iHOT-12) at a follow-up of more than four months. The aim of this study was to identify the responsiveness and ceiling effects of the English version iHOT-12 in a series of patients undergoing hip arthroscopy for intra-articular hip pathology at a minimum of one year postoperatively. Methods. A total of 171 consecutive patients undergoing hip arthroscopy with a diagnosis of femoroacetabular impingement (FAI) under the care of a single surgeon between January 2013 and March 2017 were included. iHOT-12 and EuroQol 5D-5L (EQ-5D-5L) scores were available pre- and postoperatively. Effect size and ceiling effects for the iHOT-12 were calculated with subgroup analysis. Results. A total of 122 patients (71.3%) completed postoperative PROMs scores with median follow-up of 24.3 months (interquartile range (IQR) 17.2 to 33.5). The median total cohort iHOT-12 score improved significantly from 31.0 (IQR 20 to 58) preoperatively to 72.5 (IQR 47 to 90) postoperatively (p < 0.001). The effect size (Cohen’s d) was 1.59. In all, 33 patients (27%) scored within ten points (10%) of the maximum score and 38 patients (31.1%) scored within the previously reported minimal clinically important difference (MCID) of the maximum score. Furthermore, nine (47%) male patients aged < 30 years scored within 10% of the maximum score and ten (53%) scored within the previously reported MCID of the maximum score. Conclusion. There is a previously unreported ceiling effect of the iHOT-12 at a minimum one-year follow-up which is particularly marked in young, male patients following hip arthroscopy for FAI. This tool may not have the maximum measurement required to capture the true outcome following this procedure. Cite this article: Bone Joint J 2020;102-B(8):1010–1015


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 321 - 328
1 Feb 2021
Vandeputte F Vanbiervliet J Sarac C Driesen R Corten K

Aims. Optimal exposure through the direct anterior approach (DAA) for total hip arthroplasty (THA) conducted on a regular operating theatre table is achieved with a standardized capsular releasing sequence in which the anterior capsule can be preserved or resected. We hypothesized that clinical outcomes and implant positioning would not be different in case a capsular sparing (CS) technique would be compared to capsular resection (CR). Methods. In this prospective trial, 219 hips in 190 patients were randomized to either the CS (n = 104) or CR (n = 115) cohort. In the CS cohort, a medial based anterior flap was created and sutured back in place at the end of the procedure. The anterior capsule was resected in the CR cohort. Primary outcome was defined as the difference in patient-reported outcome measures (PROMs) after one year. PROMs (Harris Hip Score (HHS), Hip disability and Osteoarthritis Outcome Score (HOOS), and Short Form 36 Item Health Survey (SF-36)) were collected preoperatively and one year postoperatively. Radiological parameters were analyzed to assess implant positioning and implant ingrowth. Adverse events were monitored. Results. At one year, there was no difference in HSS (p = 0.728), HOOS (Activity Daily Life, p = 0.347; Pain, p = 0.982; Quality of Life, p = 0.653; Sport, p = 0.994; Symptom, p = 0.459), or SF-36 (p = 0.338). Acetabular component inclination (p = 0.276) and anteversion (p = 0.392) as well as femoral component alignment (p = 0.351) were similar in both groups. There were no dislocations, readmissions, or reoperations in either group. The incidence of psoas tendinitis was six cases in the CS cohort (6%) and six cases in the CR cohort (5%) (p = 0.631). Conclusion. No clinical differences were found between resection or preservation of the anterior capsule when performing a primary THA through the DAA on a regular theatre table. In case of limited visibility during the learning curve, it might be advisable to resect a part of the anterior capsule. Cite this article: Bone Joint J 2021;103-B(2):321–328


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 56 - 63
1 Jan 2018
Smith NA Parsons N Wright D Hutchinson C Metcalfe A Thompson P Costa ML Spalding T

Aims. Meniscal allograft transplantation is undertaken to improve pain and function in patients with a symptomatic meniscal deficient knee compartment. While case series have shown improvements in patient reported outcome measures (PROMs), its efficacy has not been rigorously evaluated. This study aimed to compare PROMs in patients having meniscal transplantation with those having personalized physiotherapy at 12 months. Patients and Methods. A single-centre assessor-blinded, comprehensive cohort study, incorporating a pilot randomized controlled trial (RCT) was performed on patients with a symptomatic compartment of the knee in which a (sub)total meniscectomy had previously been performed. They were randomized to be treated either with a meniscal allograft transplantation or personalized physiotherapy, and stratified for malalignment of the limb. They entered the preference groups if they were not willing to be randomized. The Knee injury and Osteoarthritis Outcome Score (KOOS), International Knee Documentation Committee (IKDC) score and Lysholm score and complications were collected at baseline and at four, eight and 12 months following the interventions. Results. A total of 36 patients entered the study; 21 were randomized and 15 chose their treatments. Their mean age was 28 years (range 17 to 46). The outcomes were similar in the randomized and preference groups, allowing pooling of data. At 12 months, the KOOS. 4. composite score (mean difference 12, p = 0.03) and KOOS subscales of pain (mean difference 15, p = 0.02) and activities of daily living (mean difference 18, p = 0.005) were significantly superior in the meniscal transplantation group. Other PROMs also favoured this group without reaching statistical significance. There were five complications in the meniscal transplantation and one in the physiotherapy groups. Conclusion. This is the first study to compare meniscal allograft transplantation to non-operative treatment. The results provide the best quality evidence to date of the symptomatic benefits of meniscal allograft transplantation in the short term, but a multicentre RCT is required to investigate this question further. Cite this article: Bone Joint J 2018;100-B:56–63


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 759 - 765
1 Jun 2017
Eneqvist T Nemes S Brisby H Fritzell P Garellick G Rolfson O

Aims. The aims of this study were to describe the prevalence of previous lumbar surgery in patients who undergo total hip arthroplasty (THA) and to investigate their patient-reported outcomes (PROMs) one year post-operatively. Patients and Methods. Data from the Swedish Hip Arthroplasty Register and the Swedish Spine Register gathered from 2002 to 2013 were merged to identify a group of patients who had undergone lumbar surgery before THA (n = 997) and a carefully matched one-to-one control group. We investigated differences in the one-year post-operative PROMs between the groups. Linear regression analyses were used to explore the associations between previous lumbar surgery and these PROMs following THA. The prevalence of prior lumbar surgery was calculated as the ratio of patients identified with previous lumbar surgery between 2002 and 2012, and divided by the total number of patients who underwent a THA in 2012. Results. The prevalence of lumbar surgery prior to THA in 2012 was 3.5% (351 of 10 082). Linear regression analyses showed an association with more pain (B = 4.35, 95% confidence interval (CI) 2.57 to 6.12), worse EuroQol (EQ)-5D index, (B = -0.089, 95% CI -0.112 to -0.066), worse EQ VAS (B = -6.75, 95% CI -8.58 to -4.92), and less satisfaction (B = 6.04, 95% CI 4.05 to 8.02). Conclusion. Lumbar spinal surgery prior to THA is associated with less reduction of pain, worse health-related quality of life, and less satisfaction one year after THA. This is useful information to share in the decision-making process and may help establish realistic expectations of the outcomes of THA in patients who also have previously undergone lumbar spinal surgery. Cite this article: Bone Joint J 2017;99-B:759–65


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 933 - 940
1 Jul 2020
Maempel JF Clement ND Wickramasinghe NR Duckworth AD Keating JF

Aims. The aim was to compare long-term patient-reported outcome measures (PROMs) after operative and nonoperative treatment of acute Achilles tendon rupture in the context of a randomized controlled trial. Methods. PROMs including the Short Musculoskeletal Function Assessment (SMFA), Achilles Tendon Total Rupture Score (ATRS), EuroQol five-dimension (EQ-5D), satisfaction, net promoter score and data regarding re-rupture, and venous thromboembolic rates were collected for patients randomized to receive either operative or nonoperative treatment for acute Achilles tendon rupture in a previous study. Of the 80 patients originally randomized, 64 (33 treated surgically, 31 nonoperatively) patients were followed up at a mean of 15.7 years (13.4 to 17.7). Results. There was no statistically significant difference between operatively and nonoperatively treated patients, in SMFA Dysfunction Index (median 1.56 (interquartile range (IQR) 0 to 5.51) vs 1.47 (IQR 0 to 5.15); p = 0.289), SMFA Bother Index (2.08 (IQR 0 to 12.50) vs 0.00 (IQR 0 to 6.25); p = 0.074), ATRS (94 (IQR 86 to 100) vs 95 (IQR 81 to 100); p = 0.313), EQ-5D-5L (1 (IQR 0.75 to 1) vs 1 (IQR 0.84 to 1); p = 0.137) or EQ-5D health today visual analogue score (85 (IQR 72.5 to 95) vs 85 (IQR 8 to 95); p = 0.367). There was no statistically significant difference between operative and nonoperative groups in terms of satisfaction (84% vs 100%; p = 0.119) or willingness to recommend treatment to friends or family (79% vs 87%; p = 0.255). Four nonoperative patients and two in the operative group sustained a re-rupture (p = 0.306). Conclusion. Both patient groups reported good results at long-term follow-up. The findings give no evidence of superior long-term patient reported outcomes (as measured by the SMFA) for surgical treatment over nonoperative treatment. There was no demonstrable difference in other patient reported outcome measures, satisfaction, or re-rupture rates at long-term follow-up. Cite this article: Bone Joint J 2020;102-B(7):933–940