Aims. There is a lack of long-term data for minimally invasive acromioclavicular (AC) joint repair. Furthermore, it is not clear if good early clinical results can be maintained over time. The purpose of this study was to report long-term results of minimally invasive AC joint
There is little evidence examining the relationship between anatomical landmarks, radiological placement of the tunnels and long-term clinical outcomes following anterior cruciate ligament (ACL)
We describe the intermediate results of lateral ligamentous repair or
We reviewed a single-surgeon series of 300 athletic patients who had undergone
We sought to determine whether smoking affected the outcome of
Aims. Pelvic
A total of seven patients (six men and one woman)
with a defect in the Achilles tendon and overlying soft tissue underwent
reconstruction using either a composite radial forearm flap (n =
3) or an anterolateral thigh flap (n = 4). The Achilles tendons
were reconstructed using chimeric palmaris longus (n = 2) or tensor
fascia lata (n = 2) flaps or transfer of the flexor hallucis longus
tendon (n = 3). Surgical parameters such as the rate of complications
and the time between the initial repair and flap surgery were analysed.
Function was measured objectively by recording the circumference
of the calf, the isometric strength of the plantar flexors and the
range of movement of the ankle. The Achilles tendon Total Rupture
Score (ATRS) questionnaire was used as a patient-reported outcome
measure. Most patients had undergone several previous operations
to the Achilles tendon prior to flap surgery. The mean time to flap
surgery was 14.3 months (2.1 to 40.7). At a mean follow-up of 32.3 months (12.1 to 59.6) the circumference
of the calf on the operated lower limb was reduced by a mean of
1.9 cm (. sd. 0.74) compared with the contralateral limb (p
= 0.042). The mean strength of the plantar flexors on the operated
lower limb was reduced to 88.9% of that of the contralateral limb
(p = 0.043). There was no significant difference in the range of
movement between the two sides (p = 0.317). The mean ATRS score was
72 points (. sd. 20.0). One patient who had an initial successful
reconstruction developed a skin defect of the composite flap 12
months after free flap surgery and this resulted in recurrent infections,
culminating in transtibial amputation 44 months after
We reviewed 29 patients who had undergone intercalary resection for malignant tumours. Of these, 14 had received segmental allograft
Medial patellofemoral ligament (MPFL) reconstruction
is used to treat patellar instability and recurrent patellar dislocation.
Anatomical studies have found the MPFL to be a double-bundle structure.
We carried out a meta-analysis of studies reporting outcomes of
patellofemoral
Many methods of
Aims. The use of trabecular metal (TM) shells supported by augments has provided good mid-term results after revision total hip arthroplasty (THA) in patients with a bony defect of the acetabulum. The aim of this study was to assess the long-term implant survivorship and radiological and clinical outcomes after acetabular revision using this technique. Patients and Methods. Between 2006 and 2010, 60 patients (62 hips) underwent acetabular revision using a combination of a TM shell and augment. A total of 51 patients (53 hips) had complete follow-up at a minimum of seven years and were included in the study. Of these patients, 15 were men (29.4%) and 36 were women (70.6%). Their mean age at the time of revision THA was 64.6 years (28 to 85). Three patients (5.2%) had a Paprosky IIA defect, 13 (24.5%) had a type IIB defect, six (11.3%) had a type IIC defect, 22 (41.5%) had a type IIIA defect, and nine (17%) had a type IIIB defect. Five patients (9.4%) also had pelvic discontinuity. Results. The overall survival of the acetabular component at a mean of ten years postoperatively was 92.5%. Three hips (5.6%) required further revision due to aseptic loosening, and one (1.9%) required revision for infection. Three hips with aseptic loosening failed, due to insufficient screw fixation of the shell in two and pelvic discontinuity in one. The mean Harris Hip Score improved significantly from 55 (35 to 68) preoperatively to 81 points (68 to 99) at the latest follow-up (p < 0.001). Conclusion. The
This study evaluated the results of a physeal-sparing technique of intra-articular anterior cruciate ligament (ACL)
We present the results of 17 children of Tanner stage 1 or 2 who underwent
Custom-made intercalary endoprostheses may be used for the
Aims. It may not be possible to undertake revision total hip arthroplasty
(THA) in the presence of massive loss of acetabular bone stock using
standard cementless hemispherical acetabular components and metal
augments, as satisfactory stability cannot always be achieved. We
aimed to study the outcome using a
We retrospectively evaluated 18 patients with a mean age of 37.3 years (14 to 72) who had undergone pelvic
This study investigated the biomechanical performance of decellularized porcine superflexor tendon (pSFT) grafts of varying diameters when utilized in conjunction with contemporary ACL graft fixation systems. This aimed to produce a range of ‘off-the-shelf’ products with predictable mechanical performance, depending on the individual requirements of the patient. Decellularized pSFTs were prepared to create double-bundle grafts of 7 mm, 8 mm, and 9 mm diameter. Femoral and tibial fixation systems were simulated utilizing Arthrex suspension devices and interference screws in bovine bone, respectively. Dynamic stiffness and creep were measured, followed by ramp to failure from which linear stiffness and load at failure were measured. The mechanisms of failure were also recorded.Objectives
Methods
Thirteen patients with ruptures of the calcaneal tendon diagnosed more than four weeks after injury were reviewed. Eleven patients had operative
Delayed rather than early
This randomised study compared outcomes in patients with displaced fractures of the clavicle treated by open reduction and fixation by a