Advertisement for orthosearch.org.uk
Results 81 - 100 of 111
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 333 - 338
1 Mar 2013
Jack CM Molloy DO Walter WL Zicat BA Walter WK

The practice of removing a well-fixed cementless femoral component is associated with high morbidity. Ceramic bearing couples are low wearing and their use minimises the risk of subsequent further revision due to the production of wear debris. A total of 165 revision hip replacements were performed, in which a polyethylene-lined acetabular component was revised to a new acetabular component with a ceramic liner, while retaining the well-fixed femoral component. A titanium sleeve was placed over the used femoral trunnion, to which a ceramic head was added. There were 100 alumina and 65 Delta bearing couples inserted.

The mean Harris hip score improved significantly from 71.3 (9.0 to 100.0) pre-operatively to 91.0 (41.0 to 100.0) at a mean follow up of 4.8 years (2.1 to 12.5) (p < 0.001). No patients reported squeaking of the hip.

There were two fractures of the ceramic head, both in alumina bearings. No liners were seen to fracture. No fractures were observed in components made of Delta ceramic. At 8.3 years post-operatively the survival with any cause of failure as the endpoint was 96.6% (95% confidence interval (CI) 85.7 to 99.3) for the acetabular component and 94.0% (95% CI 82.1 to 98.4) for the femoral component.

The technique of revising the acetabular component in the presence of a well-fixed femoral component with a ceramic head placed on a titanium sleeve over the used trunnion is a useful adjunct in revision hip practice. The use of Delta ceramic is recommended.

Cite this article: Bone Joint J 2013;95-B:333–8.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 298 - 303
1 Mar 2006
Bhan S Pankaj A Malhotra R

We compared the safety and outcome of one-stage bilateral total hip arthroplasty with those of a two-stage procedure during different admissions in a prospective, randomised controlled trial in an Asian population. Of 168 patients included in the study, 83 had a single- and 85 a two-stage procedure. Most of the patients (59.9%) suffered from inflammatory arthritis.

The intra-operative complications, early systemic complications, the operating time, positioning of the components, the functional score, restoration of limb length and survival rates at 96 months were similar in the two groups. The total estimated blood loss was significantly lower in patients undergoing a one-stage procedure than in patients who had a two-stage procedure, but the transfusion requirements were significantly higher in the former group (p = 0.001). The hospital stay was significantly shorter in the one-stage group, 7.25 days (sd 1.30; 5 to 20) compared with 10 days (sd 1.65; 8 to 24) in the two-stage group (p = 0.023). We believe that a one-stage procedure is safe and appropriate in our population.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 5 - 18
1 Jan 2014
Leunig M Ganz R

The use of joint-preserving surgery of the hip has been largely abandoned since the introduction of total hip replacement. However, with the modification of such techniques as pelvic osteotomy, and the introduction of intracapsular procedures such as surgical hip dislocation and arthroscopy, previously unexpected options for the surgical treatment of sequelae of childhood conditions, including developmental dysplasia of the hip, slipped upper femoral epiphysis and Perthes’ disease, have become available. Moreover, femoroacetabular impingement has been identified as a significant aetiological factor in the development of osteoarthritis in many hips previously considered to suffer from primary osteoarthritis.

As mechanical causes of degenerative joint disease are now recognised earlier in the disease process, these techniques may be used to decelerate or even prevent progression to osteoarthritis. We review the recent development of these concepts and the associated surgical techniques.

Cite this article: Bone Joint J 2014;96-B:5–18.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1084 - 1087
1 Aug 2011
Tauchi R Imagama S Kanemura T Yoshihara H Sato K Deguchi M Kamiya M Ishiguro N

We reviewed seven children with torticollis due to refractory atlanto-axial rotatory fixation who were treated in a halo vest. Pre-operative three-dimensional CT and sagittal CT imaging showed deformity of the superior articular process of C2 in all patients. The mean duration of halo vest treatment was 67 days (46 to 91). The mean follow-up was 34 months (8 to 73); at the latest review six patients demonstrated remodelling of the deformed articular process. The other child, who had a more severe deformity, required C1-2 fusion.

We suggest that patients with atlanto-axial rotatory fixation who do not respond to conservative treatment and who have deformity of the superior articular process of C2 should undergo manipulative reduction and halo-vest fixation for two to three months to induce remodelling of the deformed superior articular process before C1-2 fusion is considered.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 80 - 85
1 Jan 2012
Malone AA Sanchez JS Adams R Morrey B

We report the effectiveness of revision of total elbow replacement by re-cementing. Between 1982 and 2004, 53 elbows in 52 patients were treated with re-cementing of a total elbow replacement into part or all of the existing cement mantle or into the debrided host-bone interface, without the use of structural bone augmentation or a custom prosthesis. The original implant revision was still in situ and functional in 42 of 53 elbows (79%) at a mean of 94.5 months (26 to 266) after surgery. In 31 of these 42 elbows (74%) the Mayo Elbow Performance Score was good or excellent. Overall, of the 53 elbows, 18 (34%) required re-operation, ten (19%) for loosening. A classification system was developed to identify those not suitable for revision by this technique, and using this we have showed that successful re-implantation is statistically correlated to properly addressing the bone deficiency for both the humeral (p = 0.005) and the ulnar (p = 0.039) components.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1301 - 1304
1 Oct 2009
Sidhu AS Singh AP Singh AP

We describe the results of cemented total hip replacement in 23 patients (23 hips) with active tuberculous arthritis of the hip with a mean follow-up of 4.7 years (4 to 7). In two patients the diagnosis was proved by pre-operative biopsy, whereas all others were diagnosed on a clinicoradiological basis with confirmation obtained by histopathological examination and polymerase chain reaction of tissue samples taken at the time of surgery. All patients received chemotherapy for at least three months before surgery and treatment was continued for a total of 18 months. Post-operative dislocation occurred in one patient and was managed successfully by closed reduction. No reactivation of the infection or loosening of the implant was recorded and function of the hip improved in all patients.

Total hip replacement in the presence of active tuberculous arthritis of the hip is a safe procedure when pre-operative chemotherapy is commenced and continued for an extended period after operation.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 510 - 511
1 Apr 2008
Wong K Ng TP Chiu KY

Arthrodesis of the hip has been employed since the late 19th century. Late complications can arise decades after fusion in patients who were previously asymptomatic. We describe two patients who developed pain in the hip many years after a successful fusion. There was no infection or loosening of the implants. After careful investigation, including oblique radiographs and diagnostic injections of local anaesthetic, the pain was found to be caused by protrusion of the implant. Subsequent removal of the device resulted in complete resolution of the symptoms.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 92 - 97
1 Jan 2010
Kulkarni GS Kulkarni VS Shyam AK Kulkarni RM Kulkarni MG Nayak P

Arthrolysis and dynamic splinting have been used in the treatment of elbow contractures, but there is no standardised protocol for treatment of severe contractures with an arc of flexion < 30°. We present our results of radical arthrolysis with twin incisions with the use of a monolateral hinged fixator to treat very severe extra-articular contracture of the elbow. This retrospective study included 26 patients (15 males and 11 females) with a mean age of 30 years (12 to 60). The mean duration of stiffness was 9.1 months (5.4 to 18) with mean follow-up of 5.2 years (3.5 to 9.4). The mean pre-operative arc of movement was 15.6° (0° to 30°), with mean pre-operative flexion of 64.1° (30° to 120°) and mean pre-operative extension of 52.1° (10° to 90°). Post-operatively the mean arc improved to 102.4° (60° to 135°), the mean flexion improved to 119.1° (90° to 140°) and mean extension improved to 16.8° (0° to 30°) (p < 0.001). The Mayo elbow score improved from a mean of 45 (30 to 65) to 89 (75 to 100) points, and 13 had excellent, nine had good, three had fair and one had a poor result. We had one case of severe instability and one wound dehiscence which responded well to treatment. One case had deep infection with poor results which responded well to treatment.

Our findings indicate that this method is very effective in the treatment of severe elbow contracture; however, a randomised controlled study is necessary for further evaluation.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1360 - 1365
1 Oct 2009
Sewell MD Spiegelberg BGI Hanna SA Aston WJS Meswania JM Blunn GW Henry C Cannon SR Briggs TWR

We describe the application of a non-invasive extendible endoprosthetic replacement in skeletally-mature patients undergoing revision for failed joint replacement with resultant limb-length inequality after malignant or non-malignant disease. This prosthesis was developed for tumour surgery in skeletally-immature patients but has now been adapted for use in revision procedures to reconstruct the joint or facilitate an arthrodesis, replace bony defects and allow limb length to be restored gradually in the post-operative period.

We record the short-term results in nine patients who have had this procedure after multiple previous reconstructive operations. In six, the initial reconstruction had been performed with either allograft or endoprosthetic replacement for neoplastic disease and in three for non-neoplastic disease. The essential components of the prosthesis are a magnetic disc, a gearbox and a drive screw which allows painless lengthening of the prosthesis using the principle of electromagnetic induction. The mean age of the patients was 37 years (18 to 68) with a mean follow-up of 34 months (12 to 62). They had previously undergone a mean of six (2 to 14) open procedures on the affected limb before revision with the non-invasive extendible endoprosthesis.

The mean length gained was 56 mm (19 to 107) requiring a mean of nine (3 to 20) lengthening episodes performed in the outpatient department. There was one case of recurrent infection after revision of a previously infected implant and one fracture of the prosthesis after a fall. No amputations were performed. Planned exchange of the prosthesis was required in three patients after attainment of the maximum lengthening capacity of the implant. There was no failure of the lengthening mechanism. The Mean Musculoskeletal Tumour Society rating score was 22 of 30 available points (18 to 28).

The use of a non-invasive extendible endoprosthesis in this manner provided patients with good functional results and restoration of leg-length equality, without the need for multiple open lengthening procedures.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1267 - 1273
1 Oct 2009
Queally JM Abdulkarim A Mulhall KJ

Neurological conditions affecting the hip pose a considerable challenge in replacement surgery since poor and imbalanced muscle tone predisposes to dislocation and loosening. Consequently, total hip replacement (THR) is rarely performed in such patients. In a systematic review of the literature concerning THR in neurological conditions, we found only 13 studies which described the outcome. We have reviewed the evidence and discussed the technical challenges of this procedure in patients with cerebral palsy, Parkinson’s disease, poliomyelitis and following a cerebrovascular accident, spinal injury or development of a Charcot joint. Contrary to traditional perceptions, THR can give a good outcome in these often severly disabled patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 693 - 700
1 May 2010
Makki D Alnajjar HM Walkay S Ramkumar U Watson AJ Allen PW

We carried out a retrospective review of 47 intra-articular fractures of the calcaneum treated by open reduction and internal fixation in 45 patients by a single surgeon between 1993 and 2001. The fractures were evaluated before operation by plain radiographs and a CT scan using Sanders’ classification. Osteosynthesis involved a lateral approach and the use of the AO calcaneal plate. The mean follow-up was for ten years (7 to 15). Clinical assessment included the American Orthopaedic Foot and Ankle Society Score (AOFAS), the Creighton-Nebraska Score, the Kerr, Prothero, Atkins Score and the SF-36 Health Questionnaire. The radiological evaluation consisted of lateral and axial views of the os calcis. Arthritic changes in the subtalar joint were assessed with an internal oblique view and were graded using the Morrey and Wiedeman scale.

There were 18 excellent (38.3%), 17 good (36.2%), three fair (6.3%) and nine poor (19.2%) results. Five patients had a superficial wound infection and five others eventually had a subtalar arthrodesis because of continuing pain. Restoration of Böhler’s angle was associated with a better outcome. The degree of arthritic change in the subtalar joint did not correlate with the outcome scores or Sanders’ classification. Prompt osteosynthesis should be considered for intra-articular fractures of the calcaneum in order to restore the shape of the hindfoot and Böhler’s angle.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 486 - 489
1 Apr 2007
Bassi RS Simmons D Ali F Nuttall D Birch A Trail IA Stanley JK

The Acclaim total elbow replacement is a modular system which allows implantation in both unlinked and linked modes. The results of the use of this implant in primary total elbow replacement in 36 patients, operated on between July 2000 and August 2002, are presented at a mean follow-up of 36 months (24 to 49). Only one patient did not have good relief of pain, but all had improved movement and function.

No implant showed clinical or radiological loosening, although one had a lucent area in three of seven humeral zones. The short-term results of the Acclaim total elbow replacement are encouraging. However, 11 patients (30.5%) suffered an intra-operative fracture of the humeral condyle. This did not affect the outcome, or the requirement for further surgery, except in one case where the fracture failed to unite. This problem has hopefully been addressed by redesigning the humeral resection guide. Other complications included three cases of ulnar neuropathy (8.3%) and one of deep infection (2.8%).


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1191 - 1196
1 Sep 2009
Pagenstert GI Barg A Leumann AG Rasch H Müller-Brand J Hintermann B Valderrabano V

The precise localisation of osteoarthritic changes is crucial for selective surgical treatment. Single photon-emission CT-CT (SPECT-CT) combines both morphological and biological information. We hypothesised that SPECT-CT increased the intra- and interobserver reliability to localise increased uptake compared with traditional evaluation of CT and bone scanning together. We evaluated 20 consecutive patients with pain of uncertain origin in the foot and ankle by radiography and SPECT-CT, available as fused SPECT-CT, and by separate bone scanning and CT. Five observers assessed the presence or absence of arthritis. The images were blinded and randomly ordered. They were evaluated twice at an interval of six weeks. Kappa and multirater kappa values were calculated.

The mean intraobserver reliability for SPECT-CT was excellent (κ = 0.86; 95% CI 0.81 to 0.88) and significantly higher than that for CT and bone scanning together. SPECT-CT had significantly higher interobserver agreement, especially when evaluating the naviculocuneiform and tarsometatarsal joints.

SPECT-CT is useful in localising active arthritis especially in areas where the number and configuration of joints are complex.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 155 - 159
1 Feb 2007
Saudan M Saudan P Perneger T Riand N Keller A Hoffmeyer P

We examined whether a selective cyclooxygenase-2 (COX-2) inhibitor (celecoxib) was as effective as a non-selective inhibitor (ibuprofen) for the prevention of heterotopic ossification following total hip replacement. A total of 250 patients were randomised to receive celecoxib (200 mg b/d) or ibuprofen (400 mg t.d.s) for ten days after surgery. Anteroposterior radiographs of the pelvis were examined for heterotopic ossification three months after surgery. Of the 250 patients, 240 were available for assessment. Heterotopic ossification was more common in the ibuprofen group (none 40.7% (50), Brooker class I 46.3% (57), classes II and III 13.0% (16)) than in the celecoxib group (none 59.0% (69), Brooker class I 35.9% (42), classes II and III 5.1% (6), p = 0.002). Celecoxib was more effective than ibuprofen in preventing heterotopic bone formation after total hip replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 31 - 36
1 Jan 2009
de Jong PT de Man FHR Haverkamp D Marti RK

We report the long-term outcome of a modified second-generation cementing technique for fixation of the acetabular component of total hip replacement. An earlier report has shown the superiority of this technique assessed by improved survival compared with first-generation cementing. The acetabular preparation involved reaming only to the subchondral plate, followed by impaction of the bone in the anchorage holes.

Between 1978 and 1993, 287 total hip replacements were undertaken in 244 patients with a mean age of 65.3 years (21 to 90) using a hemispherical Weber acetabular component with this modified technique for cementing and a cemented femoral component.

The survival with acetabular revision for aseptic loosening as the endpoint was 99.1% (95% confidence interval 97.9 to 100 after ten years and 85.5% (95% confidence interval 74.7 to 96.2) at 20 years. Apart from contributing to a long-lasting fixation of the component, this technique also preserved bone, facilitating revision surgery when necessary.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1407 - 1413
1 Nov 2008
Kontakis G Koutras C Tosounidis T Giannoudis P

We performed a comprehensive systematic review of the literature to examine the role of hemiarthroplasty in the early management of fractures of the proximal humerus. In all, 16 studies dealing with 810 hemiarthroplasties in 808 patients with a mean age of 67.7 years (22 to 91) and a mean follow-up of 3.7 years (0.66 to 14) met the inclusion criteria. Most of the fractures were four-part fractures or fracture-dislocations.

Several types of prosthesis were used. Early passive movement on the day after surgery and active movement after union of the tuberosities at about six weeks was described in most cases. The mean active anterior elevation was to 105.7° (10° to 180°) and the mean abduction to 92.4° (15° to 170°). The incidence of superficial and deep infection was 1.55% and 0.64%, respectively. Complications related to the fixation and healing of the tuberosities were observed in 86 of 771 cases (11.15%). The estimated incidence of heterotopic ossification was 8.8% and that of proximal migration of the humeral head 6.8%. The mean Constant score was 56.63 (11 to 98). At the final follow-up, no pain or only mild pain was experienced by most patients, but marked limitation of function persisted.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 28 - 37
1 Jan 2010
Jameson SS Langton DJ Nargol AVF

We present the early clinical and radiological results of Articular Surface Replacement (ASR) resurfacings in 214 hips (192 patients) with a mean follow-up of 43 months (30 to 57). The mean age of the patients was 56 years (28 to 74) and 85 hips (40%) were in 78 women.

The mean Harris hip score improved from 52 (11 to 81) to 95 (27 to 100) at two years and the mean University of California, Los Angeles activity score from 3.9 (1 to 10) to 7.4 (2 to 10) in the same period. Narrowing of the neck (to a maximum of 9%) was noted in 124 of 209 hips (60%). There were 12 revisions (5.6%) involving four (1.9%) early fractures of the femoral neck and two (0.9%) episodes of collapse of the femoral head secondary to avascular necrosis. Six patients (2.8%) had failure related to metal wear debris. The overall survival for our series was 93% (95% confidence interval 80 to 98) and 89% (95% confidence interval 82 to 96) for hips with acetabular components smaller than 56 mm in diameter.

The ASR implant has a lower diametrical clearance and a subhemispherical acetabular component when compared with other more frequently implanted metal-on-metal hip resurfacings. These changes may contribute to the higher failure rate than in other series, compared with other designs. Given our poor results with the small components we are no longer implanting the smaller size.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 557 - 564
1 Apr 2009
Rumian AP Draper ERC Wallace AL Goodship AE

An understanding of the remodelling of tendon is crucial for the development of scientific methods of treatment and rehabilitation. This study tested the hypothesis that tendon adapts structurally in response to changes in functional loading. A novel model allowed manipulation of the mechanical environment of the patellar tendon in the presence of normal joint movement via the application of an adjustable external fixator mechanism between the patella and the tibia in sheep, while avoiding exposure of the patellar tendon itself. Stress shielding caused a significant reduction in the structural and material properties of stiffness (79%), ultimate load (69%), energy absorbed (61%), elastic modulus (76%) and ultimate stress (72%) of the tendon compared with controls. Compared with the material properties the structural properties exhibited better recovery after re-stressing with stiffness 97%, ultimate load 92%, energy absorbed 96%, elastic modulus 79% and ultimate stress 80%. The cross-sectional area of the re-stressed tendons was significantly greater than that of stress-shielded tendons.

The remodelling phenomena exhibited in this study are consistent with a putative feedback mechanism under strain control. This study provides a basis from which to explore the interactions of tendon remodelling and mechanical environment.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1336 - 1340
1 Oct 2006
Aoki Y Yasuda K Mikami S Ohmoto H Majima T Minami A

We compared the results ten years after an inverted V-shaped high tibial osteotomy with those of a historical series of conventional closing-wedge osteotomies. The closing-wedge series consisted of 56 knees in 51 patients with a mean follow-up of 11 years (10 to 15). The inverted V-shaped osteotomy was evaluated in 48 knees in 43 patients at a mean follow-up of 14 years (10 to 19). All the patients were scored using the Japanese Orthopaedic Association rating scale for osteoarthritis of the knee and radiological assessment.

The pre-operative grade of osteoarthritis was similar in both groups. Post-operatively, the knee function score was graded as satisfactory in 63% (35) of the closing-wedge group but in 89% (43) of the inverted V-shaped osteotomy group. Post-operative radiological examination showed that delayed union and loss of correction occurred more often after a closing-wedge osteotomy than after an inverted V-shaped procedure.

Our study suggests that the inverted V-shaped osteotomy may offer more dependable long-term results than traditional closing-wedge osteotomy.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 649 - 654
1 May 2006
Gupta A Meswania J Pollock R Cannon SR Briggs TWR Taylor S Blunn G

We report our early experience with the use of a non-invasive distal femoral expandable endoprosthesis in seven skeletally immature patients with osteosarcoma of the distal femur. The patients had a mean age of 12.1 years (9 to 15) at the time of surgery. The prosthesis was lengthened at appropriate intervals in outpatient clinics, without anaesthesia, using the principle of electromagnetic induction. The patients were functionally evaluated using the Musculoskeletal Tumour Society scoring system. The mean follow-up was 20.2 months (14 to 30). The prostheses were lengthened by a mean of 25 mm (4.25 to 55) and maintained a mean knee flexion of 110° (100° to 120°). The mean Musculoskeletal Tumour Society score was 68% (11 to 29). Complications developed in two patients; one developed a flexion deformity of 25° at the knee joint, which was subsequently overcome and one died of disseminated disease. The early results from patients treated with this device have been encouraging. The implant avoids multiple surgical procedures, general anaesthesia and assists in maintaining leg-length equality.