Advertisement for orthosearch.org.uk
Results 81 - 100 of 1384
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 129 - 134
1 Jul 2021
Ayekoloye CI Abu Qa'oud M Radi M Leon SA Kuzyk P Safir O Gross AE

Aims. Improvements in functional results and long-term survival are variable following conversion of hip fusion to total hip arthroplasty (THA) and complications are high. The aim of the study was to analyze the clinical and functional results in patients who underwent conversion of hip fusion to THA using a consistent technique and uncemented implants. Methods. A total of 39 hip fusion conversions to THA were undertaken in 38 patients by a single surgeon employing a consistent surgical technique and uncemented implants. Parameters assessed included Harris Hip Score (HHS) for function, range of motion (ROM), leg length discrepancy (LLD), satisfaction, and use of walking aid. Radiographs were reviewed for loosening, subsidence, and heterotopic ossification (HO). Postoperative complications and implant survival were assessed. Results. At mean 12.2 years (2 to 24) follow-up, HHS improved from mean 34.2 (20.8 to 60.5) to 75 (53.6 to 94.0; p < 0.001). Mean postoperative ROM was flexion 77° (50° to 95°), abduction 30° (10° to 40°), adduction 20° (5° to 25°), internal rotation 18° (2° to 30°), and external rotation 17° (5° to 30°). LLD improved from mean -3.36 cm (0 to 8) to postoperative mean -1.14 cm (0 to 4; p < 0.001). Postoperatively, 26 patients (68.4%) required the use of a walking aid. Complications included one (2.5%) dislocation, two (5.1%) partial sciatic nerve injuries, one (2.5%) deep periprosthetic joint infection, two instances of (5.1%) acetabular component aseptic loosening, two (5.1%) periprosthetic fractures, and ten instances of HO (40%), of which three (7.7%) were functionally limiting and required excision. Kaplan-Meier Survival was 97.1% (95% confidence interval (CI) 91.4% to 100%) at ten years and 88.2% (95% CI 70.96 to 100) at 15 years with implant revision for aseptic loosening as endpoint and 81.7% (95% CI 70.9% to 98.0%) at ten years and 74.2% (95% CI 55.6 to 92.8) at 15 years follow-up with implant revision for all cause failure as endpoint. Conclusion. The use of an optimal and consistent surgical technique and cementless implants can result in significant functional improvement, low complication rates, long-term implant survival, and high patient satisfaction following conversion of hip fusion to THA. The possibility of requiring a walking aid should be discussed with the patient before surgery. Cite this article: Bone Joint J 2021;103-B(7 Supple B):129–134


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 136 - 143
1 Feb 2024
van der Lelij TJN Marang-van de Mheen PJ Kaptein BL Koster LA Ljung P Nelissen RGHH Toksvig-Larsen S

Aims. The objective of this study was to compare the two-year migration and clinical outcomes of a new cementless hydroxyapatite (HA)-coated titanium acetabular shell with its previous version, which shared the same geometrical design but a different manufacturing process for applying the titanium surface. Methods. Overall, 87 patients undergoing total hip arthroplasty (THA) were randomized to either a Trident II HA or Trident HA shell, each cementless with clusterholes and HA-coating. All components were used in combination with a cemented Exeter V40 femoral stem. Implant migration was measured using radiostereometric analysis (RSA), with radiographs taken within two days of surgery (baseline), and at three, 12, and 24 months postoperatively. Proximal acetabular component migration was the primary outcome measure. Clinical scores and patient-reported outcome measures (PROMs) were collected at each follow-up. Results. Mean proximal migrations at three, 12, and 24 months were 0.08 mm (95% confidence interval (CI) 0.03 to 0.14), 0.11 mm (95% CI 0.06 to 0.16), and 0.14 mm (95% CI 0.09 to 0.20), respectively, in the Trident II HA group, versus 0.11 mm (95% CI 0.06 to 0.16), 0.12 mm (95% CI 0.07 to 0.17), and 0.14 mm (95% CI 0.09 to 0.19) in the Trident HA group (p = 0.875). No significant differences in translations or rotations between the two designs were found in any other direction. Clinical scores and PROMs were comparable between groups, except for an initially greater postoperative improvement in Hip disability and Osteoarthritis Outcome Symptoms score in the Trident HA group (p = 0.033). Conclusion. The Trident II clusterhole HA shell has comparable migration with its predecessor, the Trident hemispherical HA cluster shell, suggesting a similar risk of long-term aseptic loosening. Cite this article: Bone Joint J 2024;106-B(2):136–143


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 46 - 52
1 Jan 2024
Hintermann B Peterhans U Susdorf R Horn Lang T Ruiz R Kvarda P

Aims. Implant failure has become more common as the number of primary total ankle arthroplasties (TAAs) performed has increased. Although revision arthroplasty has gained attention for functional preservation, the long-term results remain unclear. This study aimed to assess the long-term outcomes of revision TAA using a mobile-bearing prosthesis in a considerably large cohort; the risk factors for failure were also determined. Methods. This single-centre retrospective cohort study included 116 patients (117 ankles) who underwent revision TAA for failed primary TAA between July 2000 and March 2010. Survival analysis and risk factor assessment were performed, and clinical performance and patient satisfaction were evaluated preoperatively and at last follow-up. Results. The mean duration from initial revision TAA to last follow-up was 15.0 years (SD 3.0; 11.2 to 20.5). The cumulative survival rates of the revised ankles were 81% (95% confidence interval (CI) 74% to 88%), 74% (65% to 82%), and 70% (61% to 79%) at five, ten, and 15 years, respectively. Comorbidities prior to primary TAA, aseptic loosening, instability, or grafting of cysts were found to be the most common risk factors for secondary revision. The median value for preoperative pain, as assessed using the visual analogue scale, declined from 6 (interquartile range (IQR) 5 to 8) to 2 (IQR 0 to 5) (p < 0.001) and the mean American Orthopaedic Foot and Ankle Society ankle-hindfoot score improved from 43 (SD 17) preoperatively to 70 (SD 20) (p < 0.001) at last follow-up. Conclusion. Revision TAA offers acceptable survival rates after 15 years; it therefore offers a valuable option for treatment of implant failure in carefully selected cases. Although patient-reported outcomes improve substantially, the degree of improvement reported following primary TAA is not achieved. Cite this article: Bone Joint J 2024;106-B(1):46–52


Bone & Joint Open
Vol. 4, Issue 12 | Pages 923 - 931
4 Dec 2023
Mikkelsen M Rasmussen LE Price A Pedersen AB Gromov K Troelsen A

Aims. The aim of this study was to describe the pattern of revision indications for unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA) and any change to this pattern for UKA patients over the last 20 years, and to investigate potential associations to changes in surgical practice over time. Methods. All primary knee arthroplasty surgeries performed due to primary osteoarthritis and their revisions reported to the Danish Knee Arthroplasty Register from 1997 to 2017 were included. Complex surgeries were excluded. The data was linked to the National Patient Register and the Civil Registration System for comorbidity, mortality, and emigration status. TKAs were propensity score matched 4:1 to UKAs. Revision risks were compared using competing risk Cox proportional hazard regression with a shared γ frailty component. Results. Aseptic loosening (loosening) was the most common revision indication for both UKA (26.7%) and TKA (29.5%). Pain and disease progression accounted for 54.6% of the remaining UKA revisions. Infections and instability accounted for 56.1% of the remaining TKA revision. The incidence of revision due to loosening or pain decreased over the last decade, being the second and third least common indications in 2017. There was a decrease associated with fixation method for pain (hazard ratio (HR) 0.40; 95% confidence interval (CI) 0.17 to 0.94) and loosening (HR 0.29; 95% CI 0.10 to 0.81) for cementless compared to cemented, and units UKA usage for pain (HR 0.67, 95% CI 0.50 to 0.91), and loosening (HR 0.51; 95% CI 0.37 to 0.70) for high usage. Conclusion. The overall revision patterns for UKA and TKA for the last 20 years are comparable to previous published patterns. We found large changes to UKA revision patterns in the last decade, and with the current surgical practice, revision due to pain or loosening are significantly less likely. Cite this article: Bone Jt Open 2023;4(12):923–931


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 32 - 37
1 Jun 2021
Restrepo S Smith EB Hozack WJ

Aims. Cementless total knee arthroplasty (TKA) offers the potential for strong biological fixation compared with cemented TKA where fixation is achieved by the mechanical integration of the cement. Few mid-term results are available for newer cementless TKA designs, which have used additive manufacturing (3D printing). The aim of this study was to present mid-term clinical outcomes and implant survivorship of the cementless Stryker Triathlon Tritanium TKA. Methods. This was a single institution registry review of prospectively gathered data from 341 cementless Triathlon Tritanium TKAs at four to 6.8 years follow-up. Outcomes were determined by comparing pre- and postoperative Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) scores, and pre- and postoperative 12-item Veterans RAND/Short Form Health Survey (VR/SF-12) scores. Aseptic loosening and revision for any reason were the endpoints which were used to determine survivorship at five years. Results. At mid-term follow-up, the mean KOOS JR score improved significantly from 33.14 (0 t0 85, standard deviation (SD) 21.88) preoperatively to 84.12 (15.94 to 100, SD 20.51) postoperatively (p < 0.001), the mean VR/SF-12 scores improved significantly from physical health (PH), 31.21 (SD 5.32; 23.99 to 56.77) preoperatively to 42.62 (SD 10.72; 19.38 to 56.82) postoperatively (p < 0.001) and the mental health (MH), 38.15 (SD 8.17; 19.06 to 60.75) preoperatively to 55.09 (SD 9.64; 19.06 to 66.98) postoperatively (p < 0.001). A total of 11 revisions were undertaken, with an overall revision rate of 2.94%, including five for periprosthetic joint infection (1.34%), three for loosening (0.80%), two for instability (0.53%), and one for pain (0.27%). The overall survivorship was 97.06% and survivorship for aseptic loosening as the endpoint was 98.40%, with a 99.5% survivorship of the 3D-printed tibial component. Conclusion. This 3D-printed cementless total knee system shows excellent survivorship at mid-term follow-up. This design and the ability to obtain cementless fixation offers promise for excellent long-term durability. Cite this article: Bone Joint J 2021;103-B(6 Supple A):32–37


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1356 - 1361
1 Nov 2019
Chalmers BP Mehrotra KG Sierra RJ Pagnano MW Taunton MJ Abdel MP

Aims. Knee osteonecrosis in advanced stages may lead to joint degeneration. Total knee arthroplasty (TKA) for osteonecrosis has traditionally been associated with suboptimal results. We analyzed outcomes of contemporary TKAs for osteonecrosis, with particular emphasis on: survivorship free from aseptic loosening, any revision, and any reoperation plus the clinical outcomes, complications, and radiological results. Patients and Methods. In total, 156 patients undergoing 167 primary TKAs performed for osteonecrosis between 2004 and 2014 at a single institution were reviewed. The mean age at index TKA was 61 years (14 to 93) and the mean body mass index (BMI) was 30 kg/m. 2. (18 to 51) The mean follow-up was six years (2 to 12). A total of 110 TKAs (66%) were performed for primary osteonecrosis and 57 TKAs (34%) for secondary osteonecrosis. Overall, 15 TKAs (9%) had tibial stems, while 12 TKAs (7%) had femoral stems. Posterior-stabilized designs were used in 147 TKAs (88%) of TKAs. Bivariate Cox regression analysis was conducted to identify risk factors for revision and reoperation. Results. Survivorship free from aseptic loosening, any revision, and any reoperation at ten years was 97% (95% confidence interval (CI) 93 to 100), 93% (95% CI 85 to 100), and 82% (95% CI 69 to 93), respectively. No factors, including age, sex, BMI, primary versus secondary osteonecrosis, stem utilization, and constraint, were identified as risk factors for reoperation. Four TKAs (2%) underwent revision, most commonly for tibial aseptic loosening (n = 2). Excluding revisions and reoperations, there was a total of 11 complications (7%), with the most common being a manipulation under anaesthesia (six TKAs, 4%). Mean Knee Society Scores (Knee component) significantly improved from 57 (32 to 87) preoperatively to 91 (49 to 100) postoperatively (p < 0.001). No unrevised TKAs had complete radiolucent lines or radiological evidence of loosening. Conclusion. Contemporary cemented TKAs with selective stem utilization for osteonecrosis resulted in durable survivorship, a low complication rate, and reliable improvement in clinical outcomes. Cite this article: Bone Joint J 2019;101-B:1356–1361


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 492 - 499
1 Mar 2021
Garcia-Rey E Saldaña L Garcia-Cimbrelo E

Aims. Bone stock restoration of acetabular bone defects using impaction bone grafting (IBG) in total hip arthroplasty may facilitate future re-revision in the event of failure of the reconstruction. We hypothesized that the acetabular bone defect during re-revision surgery after IBG was smaller than during the previous revision surgery. The clinical and radiological results of re-revisions with repeated use of IBG were also analyzed. Methods. In a series of 382 acetabular revisions using IBG and a cemented component, 45 hips (45 patients) that had failed due to aseptic loosening were re-revised between 1992 and 2016. Acetabular bone defects graded according to Paprosky during the first and the re-revision surgery were compared. Clinical and radiological findings were analyzed over time. Survival analysis was performed using a competing risk analysis. Results. Intraoperative bone defect during the initial revision included 19 Paprosky type IIIA and 29 Paprosky type IIIB hips; at re-revision, seven hips were Paprosky type II, 27 type IIIA and 11 were type IIIB (p = 0.020). The mean preoperative Harris Hip Score was 45.4 (SD 6.4), becoming 80.7 (SD 12.7) at the final follow-up. In all, 12 hips showed radiological migration of the acetabular component, and three required further revision surgery. The nine-year cumulative failure incidence (nine patients at risk) of the acetabular component for further revision surgery was 9.6% (95% confidence interval (CI) 2.9 to 21.0) for any cause, and 7.5% (95% CI 1.9 to 18.5) for aseptic loosening. Hips with a greater hip height had a higher risk for radiological migration (odds ratio 1.09, 95% CI 1.02 to 1.17; p = 0.008). Conclusion. Bone stock restoration can be obtained using IBG in revision hip surgery. This technique is also useful in re-revision surgery; however, a better surgical technique including a closer distance to hip rotation centre could decrease the risk of radiological migration of the acetabular component. A longer follow-up is required to assess potential fixation deterioration. Cite this article: Bone Joint J 2021;103-B(3):492–499


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1078 - 1085
1 Oct 2023
Cance N Batailler C Shatrov J Canetti R Servien E Lustig S

Aims. Tibial tubercle osteotomy (TTO) facilitates surgical exposure and protects the extensor mechanism during revision total knee arthroplasty (rTKA). The purpose of this study was to determine the rates of bony union, complications, and reoperations following TTO during rTKA, to assess the functional outcomes of rTKA with TTO at two years’ minimum follow-up, and to identify the risk factors of failure. Methods. Between January 2010 and September 2020, 695 rTKAs were performed and data were entered into a prospective database. Inclusion criteria were rTKAs with concomitant TTO, without extensor mechanism allograft, and a minimum of two years’ follow-up. A total of 135 rTKAs were included, with a mean age of 65 years (SD 9.0) and a mean BMI of 29.8 kg/m. 2. (SD 5.7). The most frequent indications for revision were infection (50%; 68/135), aseptic loosening (25%; 34/135), and stiffness (13%; 18/135). Patients had standardized follow-up at six weeks, three months, six months, and annually thereafter. Complications and revisions were evaluated at the last follow-up. Functional outcomes were assessed using the Knee Society Score (KSS) and range of motion. Results. The mean follow-up was 51 months (SD 26; 24 to 121). Bony union was confirmed in 95% of patients (128/135) at a mean of 3.4 months (SD 2.7). The complication rate was 15% (20/135), consisting of nine tibial tubercle fracture displacements (6.7%), seven nonunions (5%), two delayed unions, one tibial fracture, and one wound dehiscence. Seven patients (5%) required eight revision procedures (6%): three bone grafts, three osteosyntheses, one extensor mechanism allograft, and one wound revision. The functional scores and flexion were significantly improved after surgery: mean KSS knee, 48.8 (SD 17) vs 79.6 (SD 20; p < 0.001); mean KSS function, 37.6 (SD 21) vs 70.2 (SD 30; p < 0.001); mean flexion, 81.5° (SD 33°) vs 93° (SD 29°; p = 0.004). Overall, 98% of patients (n = 132) had no extension deficit. The use of hinge implants was a significant risk factor for tibial tubercle fracture (p = 0.011). Conclusion. TTO during rTKA was an efficient procedure to improve knee exposure with a high union rate, but had significant specific complications. Functional outcomes were improved at mid term. Cite this article: Bone Joint J 2023;105-B(10):1078–1085


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1002 - 1009
1 Aug 2018
Westerman RW Whitehouse SL Hubble MJW Timperley AJ Howell JR Wilson MJ

Aims. The aim of this study was to report the initial results of the Exeter V40 stem, which became available in 2000. Patients and Methods. A total of 540 total hip arthroplasties (THAs) were performed in our unit using this stem between December 2000 and May 2002. Our routine protocol is to review patients postoperatively and at one, five, and ten years following surgery. Results. A total of 145 patients (26.9%) died before ten years and of the remaining 395 stems, 374 (94.7%) remain in situ. A total of 21 well-fixed stems (5.3%) were revised. Ten were exchanged using a cement-in-cement technique to facilitate acetabular revision. Three were revised for infection, one for instability, one for fracture of the stem, and six following a periprosthetic fracture. An additional 16 acetabular components (4.1%) were revised; five for aseptic loosening and 11 for instability. There were no revisions for aseptic loosening of the stem, and no evidence of aseptic loosening in any hip. The fate of every stem is known and all patients remain under review. Survivorship, with revision of the stem for aseptic loosening as the endpoint, was 100%. At 13.5 years, the Kaplan–Meier survival rate for all-cause revision of the stem was 96.8% (95% confidence interval (CI) 94.8 to 98.8) and all-cause revision (including acetabular revision, infection, and instability) was 91.2% (95% CI 88.3 to 94.1). Conclusion. No stem was revised for aseptic loosening in this series. The contemporary Exeter V40 stem continues to perform well, and survival has remained comparable with that of the Exeter Universal stem. Cite this article: Bone Joint J 2018;100-B:1002–9


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1670 - 1674
5 Dec 2020
Khan T Middleton R Alvand A Manktelow ARJ Scammell BE Ollivere BJ

Aims. To determine mortality risk after first revision total hip arthroplasty (THA) for periprosthetic femoral fracture (PFF), and to compare this to mortality risk after primary and first revision THA for other common indications. Methods. The study cohort consisted of THAs recorded in the National Joint Registry between 2003 and 2015, linked to national mortality data. First revision THAs for PFF, infection, dislocation, and aseptic loosening were identified. We used a flexible parametric model to estimate the cumulative incidence function of death at 90 days, one year, and five years following first revision THA and primary THA, in the presence of further revision as a competing risk. Analysis covariates were age, sex, and American Society of Anesthesiologists (ASA) grade. Results. A total of 675,078 primary and 74,223 first revision THAs were included (of which 6,131 were performed for PFF). Following revision for PFF, mortality ranged from 9% at 90 days, 21% at one year, and 60% at five years in the highest risk group (males, ≥ 75 years, ASA ≥ 3) to 0.6%, 1.4%, and 5.5%, respectively, for the lowest risk group (females, < 75 years, ASA ≤ 2). Mortality was greater in all groups following first revision THA for PFF than for primary THA. Compared to mortality risk after first revision THA for infection, dislocation, or aseptic loosening, revision for PFF was associated with higher five-year mortality in all groups except males < 75 years with an ASA ≤ 2. Conclusion. Mortality risk after revision THA for PFF is high, reaching 60% at five years in the highest risk patient group. In comparison to other common indications for revision, PFF demonstrated the highest overall risk of mortality at five years. These estimates can be used in the surgical decision-making process and when counselling patients and carers regarding surgical risk. Cite this article: Bone Joint J 2020;102-B(12):1670–1674


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 122 - 128
1 Jul 2021
Tibbo ME Limberg AK Gausden EB Huang P Perry KI Yuan BJ Berry DJ Abdel MP

Aims. The prevalence of ipsilateral total hip arthroplasty (THA) and total knee arthroplasty (TKA) is rising in concert with life expectancy, putting more patients at risk for interprosthetic femur fractures (IPFFs). Our study aimed to assess treatment methodologies, implant survivorship, and IPFF clinical outcomes. Methods. A total of 76 patients treated for an IPFF from February 1985 to April 2018 were reviewed. Prior to fracture, at the hip/knee sites respectively, 46 femora had primary/primary, 21 had revision/primary, three had primary/revision, and six had revision/revision components. Mean age and BMI were 74 years (33 to 99) and 30 kg/m. 2. (21 to 46), respectively. Mean follow-up after fracture treatment was seven years (2 to 24). Results. Overall, 59 fractures were classified as Vancouver C (Unified Classification System (UCS) D), 17 were Vancouver B (UCS B). In total, 57 patients (75%) were treated with open reduction and internal fixation (ORIF); three developed nonunion, three developed periprosthetic joint infection, and two developed aseptic loosening. In all, 18 patients (24%) underwent revision arthroplasty including 13 revision THAs, four distal femoral arthroplasties (DFAs), and one revision TKA: of these, one patient developed aseptic loosening and two developed nonunion. Survivorship free from any reoperation was 82% (95% confidence interval (CI) 66.9% to 90.6%) and 77% (95% CI 49.4% to 90.7%) in the ORIF and revision groups at two years, respectively. ORIF patients who went on to union tended to have stemmed knee components and greater mean interprosthetic distance (IPD = 189 mm (SD 73.6) vs 163 mm (SD 36.7); p = 0.546) than nonunited fractures. Patients who went on to nonunion in the revision arthroplasty group had higher medullary diameter: cortical width ratio (2.5 (SD 1.7) vs 1.3 (SD 0.3); p = 0.008) and lower IPD (36 mm (SD 30.6) vs 214 mm (SD 32.1); p < 0.001). At latest follow-up, 95% of patients (n = 72) were ambulatory. Conclusion. Interprosthetic femur fractures are technically and biologically challenging cases. Individualized approaches to internal fixation versus revision arthroplasty led to an 81% (95% CI 68.3% to 88.6%) survivorship free from reoperation at two years with 95% of patients ambulatory. Continued improvements in management are warranted. Cite this article: Bone Joint J 2021;103-B(7 Supple B):122–128


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 997 - 1002
1 Aug 2020
Leong JW Cook MJ O’Neill TW Board TN

Aims. The aim of this study was to investigate whether the use of antibiotic-loaded bone cement influenced the risk of revision surgery after primary total hip arthroplasty (THA) for osteoarthritis. Methods. The study involved data collected by the National Joint Registry (NJR) for England and Wales, Northern Ireland and the Isle of Man between 1 September 2005 and 31 August 2017. Cox proportional hazards were used to investigate the association between use of antibiotic-loaded bone cement and the risk of revision due to prosthetic joint infection (PJI), with adjustments made for the year of the initial procedure, age at the time of surgery, sex, American Society of Anesthesiologists (ASA) grade, head size, and body mass index (BMI). We looked also at the association between use of antibiotic-loaded bone cement and the risk of revision due to aseptic loosening or osteolysis. Results. The cohort included 418,857 THAs of whom 397,896 had received antibiotic-loaded bone cement and 20,961 plain cement. After adjusting for putative confounding factors, the risk of revision for PJI was lower in those in whom antibiotic-loaded bone cement was used (hazard ration (HR) 0.79; 95% confidence interval (CI) 0.64 to 0.98). There was also a protective effect on the risk of revision due to aseptic loosening or osteolysis, in the period of > 4.1 years after primary THA, HR 0.57, 95% CI 0.45, 0.72. Conclusion. Within the limits of registry analysis, this study showed an association between the use of antibiotic-loaded bone cement and lower rates of revision due to PJI. The findings support the continued use of antibiotic-loaded bone cement in cemented THA. Cite this article: Bone Joint J 2020;102-B(8):997–1002


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 724 - 731
1 Jun 2019
Bernthal NM Upfill-Brown A Burke ZDC Ishmael CR Hsiue P Hori K Hornicek F Eckardt JJ

Aims. Aseptic loosening is a major cause of failure in cemented endoprosthetic reconstructions. This paper presents the long-term outcomes of a custom-designed cross-pin fixation construct designed to minimize rotational stress and subsequent aseptic loosening in selected patients. The paper will also examine the long-term survivorship and modes of failure when using this technique. Patients and Methods. A review of 658 consecutive, prospectively collected cemented endoprosthetic reconstructions for oncological diagnoses at a single centre between 1980 and 2017 was performed. A total of 51 patients were identified with 56 endoprosthetic implants with cross-pin fixation, 21 of which were implanted following primary resection of tumour. Locations included distal femoral (n = 36), proximal femoral (n = 7), intercalary (n = 6), proximal humeral (n = 3), proximal tibial (n = 3), and distal humeral (n = 1). Results. The median follow-up was 132 months (interquartile range (IQR) 44 to 189). In all, 20 stems required revision: eight for infection, five for structural failure, five for aseptic loosening, and two for tumour progression. Mechanical survivorship at five, ten, and 15 years was 84%, 78%, and 78%, respectively. Mechanical failure rate varied by location, with no mechanical failures of proximal femoral constructs and distal femoral survivorship of 82%, 77%, and 77% at five, ten, and 15 years. The survivorship of primary constructs at five years was 74%, with no failure after 40 months, while the survivorship for revision constructs was 89%, 80%, and 80% at five, ten, and 15 years. . Conclusion. The rate of mechanical survivorship in our series is similar to those reported for other methods of reconstruction for short diaphyseal segments, such as compressive osseointegration. The mechanical failure rate differed by location, while there was no substantial difference in long-term survival between primary and revision reconstructions. Overall, custom cross-pin fixation is a viable option for endoprosthetic reconstruction of short metaphyseal segments with an acceptable rate of mechanical failure. Cite this article: Bone Joint J 2019;101-B:724–731


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 808 - 816
1 Aug 2024
Hall AJ Cullinan R Alozie G Chopra S Greig L Clarke J Riches PE Walmsley P Ohly NE Holloway N

Aims. Total knee arthroplasty (TKA) with a highly congruent condylar-stabilized (CS) articulation may be advantageous due to increased stability versus cruciate-retaining (CR) designs, while mitigating the limitations of a posterior-stabilized construct. The aim was to assess ten-year implant survival and functional outcomes of a cemented single-radius TKA with a CS insert, performed without posterior cruciate ligament sacrifice. Methods. This retrospective cohort study included consecutive patients undergoing TKA at a specialist centre in the UK between November 2010 and December 2012. Data were collected using a bespoke electronic database and cross-referenced with national arthroplasty audit data, with variables including: preoperative characteristics, intraoperative factors, complications, and mortality status. Patient-reported outcome measures (PROMs) were collected by a specialist research team at ten years post-surgery. There were 536 TKAs, of which 308/536 (57.5%) were in female patients. The mean age was 69.0 years (95% CI 45.0 to 88.0), the mean BMI was 32.2 kg/m. 2. (95% CI 18.9 to 50.2), and 387/536 (72.2%) survived to ten years. There were four revisions (0.7%): two deep infections (requiring debridement and implant retention), one aseptic loosening, and one haemosiderosis. Results. Kaplan-Meier analysis demonstrated no difference in implant survival according to sex, age, or obesity status. Ten-year PROMs were available for 196/387 (50.6%) surviving patients and were excellent: mean Oxford Knee Score 34.4 (95% CI 32.7 to 36.1); mean Forgotten Joint Score (FJS) 51.2 (95% CI 16.1 to 86.3); mean EuroQol five-dimension five-level questionnaire score 69.9 (95% CI 46.8 to 93.0); 141/196 (71.9%) achieved the 22-point FJS patient-acceptable symptom state (PASS); and 156/196 (79.6%) were “very satisfied or satisfied”. Conclusion. This is the only large study reporting ten-year implant survival and functional outcomes of TKA using a cemented single-radius design and with a CS tibial bearing construct. The findings of excellent implant survival, safety, and functional outcomes indicate that this combination is a safe and effective option in routine TKA. Further investigation of this single-radius design TKA with CS tibial bearings with well-matched patient study groups will allow further insight into the performance of these implants. Cite this article: Bone Joint J 2024;106-B(8):808–816


Aims. For rare cases when a tumour infiltrates into the hip joint, extra-articular resection is required to obtain a safe margin. Endoprosthetic reconstruction following tumour resection can effectively ensure local control and improve postoperative function. However, maximizing bone preservation without compromising surgical margin remains a challenge for surgeons due to the complexity of the procedure. The purpose of the current study was to report clinical outcomes of patients who underwent extra-articular resection of the hip joint using a custom-made osteotomy guide and 3D-printed endoprosthesis. Methods. We reviewed 15 patients over a five-year period (January 2017 to December 2022) who had undergone extra-articular resection of the hip joint due to malignant tumour using a custom-made osteotomy guide and 3D-printed endoprosthesis. Each of the 15 patients had a single lesion, with six originating from the acetabulum side and nine from the proximal femur. All patients had their posterior column preserved according to the surgical plan. Results. Postoperative pathological assessment revealed a negative surgical margin was achieved in all patients. At final follow-up, 13.3% (2/15) died and no recurrence occurred. The overall survival was 81.7% at five years. None of the patients showed any signs of aseptic loosening, and no wound healing issues were observed. In total, 20% (3/15) developed complications, with two cases of early hip dislocation and one case of deep infection. The cumulative incidence of mechanical and non-mechanical failure in this series was 13.7% and 9.3%, respectively, at five years. In this cohort, the mean time to full weightbearing was 5.89 (SD 0.92) weeks and the mean Musculoskeletal Tumor Society score was 24.1 (SD 4.4). Conclusion. For patients with a hip joint tumour who met the inclusion criteria and were deemed suitable for posterior column preservation, a custom-made osteotomy guide combined with 3D-printed endoprosthesis is worth performing when treating patients who require extra-articular resection of the hip joint, as it can achieve adequate margin for local control, maximize bone preservation to maintain pelvic ring integrity, reduce the risk of complications by simplifying the surgical procedure, and allow for more precise reconstruction for better function. Cite this article: Bone Jt Open 2024;5(11):1027–1036


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 967 - 980
1 Aug 2020
Chou TA Ma H Wang J Tsai S Chen C Wu P Chen W

Aims. The aims of this study were to validate the outcome of total elbow arthroplasty (TEA) in patients with rheumatoid arthritis (RA), and to identify factors that affect the outcome. Methods. We searched PubMed, MEDLINE, Cochrane Reviews, and Embase from between January 2003 and March 2019. The primary aim was to determine the implant failure rate, the mode of failure, and risk factors predisposing to failure. A secondary aim was to identify the overall complication rate, associated risk factors, and clinical performance. A meta-regression analysis was completed to identify the association between each parameter with the outcome. Results. A total of 38 studies including 2,118 TEAs were included in the study. The mean follow-up was 80.9 months (8.2 to 156). The implant failure and complication rates were 16.1% (95% confidence interval (CI) 0.128 to 0.200) and 24.5% (95% CI 0.203 to 0.293), respectively. Aseptic loosening was the most common mode of failure (9.5%; 95% CI 0.071 to 0.124). The mean postoperative ranges of motion (ROMs) were: flexion 131.5° (124.2° to 138.8°), extension 29.3° (26.8° to 31.9°), pronation 74.0° (67.8° to 80.2°), and supination 72.5° (69.5° to 75.5°), and the mean postoperative Mayo Elbow Performance Score (MEPS) was 89.3 (95% CI 86.9 to 91.6). The meta-regression analysis identified that younger patients and implants with an unlinked design correlated with higher failure rates. Younger patients were associated with increased complications, while female patients and an unlinked prosthesis were associated with aseptic loosening. Conclusion. TEA continues to provide satisfactory results for patients with RA. However, it is associated with a substantially higher implant failure and complication rates compared with hip and knee arthroplasties. The patient’s age, sex, and whether cemented fixation and unlinked prosthesis were used can influence the outcome. Level of Evidence: Therapeutic Level IV. Cite this article: Bone Joint J 2020;102-B(8):967–980


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 747 - 757
1 Jun 2022
Liang H Yang Y Guo W Yan L Tang X Li D Qu H Zang J Du Z

Aims. The aim of this study was to investigate the feasibility of application of a 3D-printed megaprosthesis with hemiarthroplasty design for defects of the distal humerus or proximal ulna following tumour resection. Methods. From June 2018 to January 2020, 13 patients with aggressive or malignant tumours involving the distal humerus (n = 8) or proximal ulna (n = 5) were treated by en bloc resection and reconstruction with a 3D-printed megaprosthesis with hemiarthroplasty, designed in our centre. In this paper, we summarize the baseline and operative data, oncological outcome, complication profiles, and functional status of these patients. Results. Preparation of the prosthesis was a mean of 8.0 days (SD 1.5), during which time no patients experienced tumour progression. The mean operating time and intraoperative blood loss were 158.1 minutes (SD 67.6) and 176.9 ml (SD 187.8), respectively. All of the prostheses were implanted successfully. During a mean follow-up of 25.7 months (SD 7.8), no patients died, but four had complications (two superficial wound problems, one temporary palsy of radial nerve, and one dislocation). No aseptic loosening, structural failure, infection, heterotopic ossification, or degenerative arthritis was seen in this study. The mean flexion of the elbow was 119.6° (SD 15.9°) and the mean extension lag was 11.9° (SD 13.8°). The mean Musculoskeletal Tumor Society 93 score and Mayo Elbow Performance Score were 28.4 (SD 0.9) and 97.7 (SD 4.4), respectively. Conclusion. The custom-made, 3D-printed megaprosthesis with hemiarthroplasty is a feasible option for functional reconstruction after resection of a tumour in the distal humerus or proximal ulna. Cite this article: Bone Joint J 2022;104-B(6):747–757


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 760 - 767
1 Jul 2019
Galea VP Rojanasopondist P Laursen M Muratoglu OK Malchau H Bragdon C

Aims. Vitamin E-diffused, highly crosslinked polyethylene (VEPE) and porous titanium-coated (PTC) shells were introduced in total hip arthroplasty (THA) to reduce the risk of aseptic loosening. The purpose of this study was: 1) to compare the wear properties of VEPE to moderately crosslinked polyethylene; 2) to assess the stability of PTC shells; and 3) to report their clinical outcomes at seven years. Patients and Methods. A total of 89 patients were enrolled into a prospective study. All patients received a PTC shell and were randomized to receive a VEPE liner (n = 44) or a moderately crosslinked polyethylene (ModXLPE) liner (n = 45). Radiostereometric analysis (RSA) was used to measure polyethylene wear and component migration. Differences in wear were assessed while adjusting for body mass index, activity level, acetabular inclination, anteversion, and head size. Plain radiographs were assessed for radiolucency and patient-reported outcome measures (PROMs) were administered at each follow-up. Results. In total, 73 patients (82%) completed the seven-year visit. Mean seven-year linear proximal penetration was -0.07 mm (. sd. 0.16) and 0.00 mm (. sd. 0.22) for the VEPE and ModXLPE cohorts, respectively (p = 0.116). PROMs (p = 0.310 to 0.807) and radiolucency incidence (p = 0.330) were not different between the polyethylene cohorts. The mean proximal shell migration rate was 0.04 mm per year (. sd. 0.09). At seven years, patients with radiolucency (34%) demonstrated greater migration (mean difference: 0.6 mm (. sd. 0.2); p < 0.001). PROMs were lower for patients with radiolucency and greater proximal migration (p = 0.009 to p = 0.045). No implants were revised for aseptic loosening. Conclusion. This is the first randomized controlled trial to report seven-year RSA results for VEPE. All wear rates were below the previously reported osteolysis threshold (0.1 mm per year). PTC shells demonstrated acceptable primary stability through seven years, as indicated by low migration and lack of aseptic loosening. However, patients with acetabular radiolucency were associated with higher shell migration and lower PROM scores. Cite this article: Bone Joint J 2019;101-B:760–767


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 818 - 823
1 Jun 2017
Kodama A Mizuseki T Adachi N

Aims. We assessed the long-term (more than ten-year) outcomes of the Kudo type-5 elbow prosthesis in patients with rheumatoid arthritis (RA). Materials and Methods. We reviewed 41 elbows (Larsen Grade IV, n = 21; Grade V, n = 20) in 31 patients with RA who had undergone a Kudo type-5 total elbow arthroplasty (TEA) between 1994 and 2003, and had been followed up for more than ten years. The humeral component was cementless and the all-polyethylene ulnar component cemented in every patient. Clinical outcome was assessed using the Mayo elbow performance score. We calculated the revision rate and evaluated potential risk factors for revision. The duration of follow-up was a mean 141 months (120 to 203). Results. Aseptic loosening of the ulnar component occurred in 11 elbows. There was no radiolucency around any humeral component. There was one deep infection. The survival rate according to Kaplan-Meier survivorship analysis was 87.8% after five years and 70.7% after ten years. The range of extension/flexion was a mean -38° (-80° to 0°)/105° (30° to 150°) before surgery and -40° (-70° to -20°)/132° (100° to 150°) at the final follow-up, while the mean Mayo elbow performance score was 43 before surgery and 80 at final follow-up. Disease duration of RA up to the TEA of < 15 years and a pre-operative range of movement (ROM) of > 85° were significant risk factors for revision or aseptic loosening. Conclusion. Although Kudo type-5 prostheses gave satisfactory results in the short-term, aseptic loosening increased after five years. In most cases, elbow function was maintained in the long-term without loosening of the implant. A short duration from the onset of RA to TEA and a large pre-operative ROM were significant risk factors for revision or aseptic loosening. Cite this article: Bone Joint J 2017;99-B:818–23


Bone & Joint Research
Vol. 9, Issue 7 | Pages 333 - 340
1 Jul 2020
Mumith A Coathup M Edwards TC Gikas P Aston W Blunn G

Aims. Limb salvage in bone tumour patients replaces the bone with massive segmental prostheses where achieving bone integration at the shoulder of the implant through extracortical bone growth has been shown to prevent loosening. This study investigates the effect of multidrug chemotherapy on extracortical bone growth and early radiological signs of aseptic loosening in patients with massive distal femoral prostheses. Methods. A retrospective radiological analysis was performed on adult patients with distal femoral arthroplasties. In all, 16 patients were included in the chemotherapy group with 18 patients in the non-chemotherapy control group. Annual radiographs were analyzed for three years postoperatively. Dimensions of the bony pedicle, osseointegration of the hydroxyapatite (HA) collar surface, bone resorption at the implant shoulder, and radiolucent line (RLL) formation around the cemented component were analyzed. Results. A greater RLL score (p = 0.041) was observed at three years postoperatively, with those receiving chemotherapy showing greater radiological loosening compared with those not receiving chemotherapy. Chemotherapy patients experience osteolysis at the shoulder of the ingrowth collar over time (p < 0.001) compared with non-chemotherapy patients where osteolysis was not observed. A greater median percentage integration of the collar surface was observed in the non-chemotherapy group (8.6%, interquartile range (IQR) 0.0% to 37.9%; p = 0.021) at three years. Bone growth around the collar was observed in both groups, and no statistical difference in amount of extracortical bony bridging was seen. Conclusion. Multidrug chemotherapy affects the osseointegration of ingrowth collars and accelerates signs of radiological loosening. This may increase the risk of aseptic loosening in patients with massive segmental implants used to treat bone cancer. Cite this article: Bone Joint Res 2020;9(7):333–340