Advertisement for orthosearch.org.uk
Results 1001 - 1020 of 1515
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1407 - 1408
1 Nov 2018
Simpson AHRW Frost H Norrie J


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 377 - 381
1 May 1988
Cheng C Gross A

We reviewed 40 cementless Porous Coated Anatomic knee replacements in 34 consecutive patients. The average follow-up was 12.9 months (range 6 to 36 months). At review, loose beads were identified in 23 knees, in 11 on the femoral side and in 16 on the tibial side (in five knees on both sides). One loose bead was adjacent to the patella. In four knees there were intra-articular beads. Radiolucent lines at the interface between bone and prosthesis were seen in 19 knees, in six on the femoral side and in 16 on the tibial side (in three knees on both sides). In relation to the tibial component loose beads were associated with a radiolucent line in all except one case. Progressive loosening with an increasing number of loose beads was seen in three knees. At this early stage of follow-up there was no correlation between the clinical results and the presence of loose beads


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 55 - 62
1 Jan 1984
Grimer R Karpinski M Edwards A

One hundred and three sequential Stanmore knee replacements were reviewed retrospectively on two occasions with a maximal follow-up period of nine years three months. This knee prosthesis, which is hinged, was successful in alleviating pain, stabilising an unstable knee and modestly increasing the arc of flexion. Walking capacity was increased and flexion contractures were reduced. There were seven cases of infection and four of fracture around the prosthesis. All these proved difficult to treat and two knees with both fracture and infection needed amputation. Eight knees were revised for aseptic loosening and a further 14 were found to have radiological signs of loosening. The results have been analysed by the methods advocated by Tew and Waugh and give a cumulative success rate of 80 per cent at seven years, provided success is judged solely by whether the prosthesis is still in situ. The role of the Stanmore knee as a primary arthroplasty is discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 411 - 413
1 May 1998
Sutton PM Greene T Howell FR

We performed a prospective, randomised study comparing the rates of glove perforation using double latex gloving with or without a disposable protective glove liner (Paraderm) on 118 patients undergoing primary or revision arthroplasty of the hip or knee by one surgeon (FRH). The patients were randomly allocated into two groups: in group 1 an inner and outer pair of latex gloves were worn as double gloves and in group 2 the glove liner was worn between the two latex gloves. There was glove perforation in at least one outer glove in 99 operations (84%). The operating surgeon was aware of the perforation in 21 of these. There were 22 perforations of the inner glove. Group 1 had a significantly higher perforation rate per operation (p < 0.05) than group 2. Our findings show that protective glove liners significantly reduce the rate of perforation of the inner glove during hip and knee arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 92 - 94
1 Jan 1996
Brown AR Taylor GJS Gregg PJ

Despite the use of ultraclean air, there are still cases of infection in total joint arthroplasty. One possible route by which bacteria may enter the wound is indirectly by contamination of instruments during skin preparation and draping. We found that bacterial air counts were 4.4 times higher during preparation and draping for hip or knee arthroplasty using an unscrubbed, ungowned leg holder than during the operation itself. With the leg holder scrubbed and gowned during preparation and draping, the air counts were reduced but were still 2.4 fold greater than intraoperatively. On some occasions, the air counts during preparation and draping exceeded the standards for ultraclean air irrespective of the attire of the leg holder. We recommend that the leg is held by a scrubbed and gowned member of the team. More importantly, we consider that instrument packs should be opened only after skin preparation and draping have been completed


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 6 | Pages 930 - 937
1 Nov 1994
Keblish P Varma A Greenwald A

Patellofemoral problems are a common cause of morbidity and reoperation after total knee arthroplasty. We made a prospective study of 52 patients who had bilateral arthroplasty (104 knees) and in whom the patella was resurfaced on one side and not on the other. A movable-bearing prosthesis with an anatomical femoral groove was implanted on both sides by the same surgeon using an otherwise identical technique. The mean follow-up was 5.24 years (2 to 10). In the 30 available patients (60 knees) there was no difference between the two sides in subjective preference, performance on ascending and descending stairs or the incidence of anterior knee pain. Radiographs showed no differences in prosthetic alignment, femoral condylar height, patellar congruency or joint line position. The use of an appropriate prosthetic design and careful surgical technique can provide equivalent results after knee arthroplasty with or without patellar resurfacing. Given the indications and criteria, which we discuss, retention of the patellar surface is an acceptable option


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 886 - 889
1 Sep 1999
Davis N Curry A Gambhir AK Panigrahi H Walker CRC Wilkins EGL Worsley MA Kay PR

All surgical operations have the potential for contamination, and the equipment used can harbour bacteria. We collected samples from 100 elective primary hip and knee arthroplasties. These showed rates of contamination of 11.4% for the sucker tips, 14.5% for light handles, 9.4% for skin blades and 3.2% for the inside blades used during surgery; 28.7% of gloves used for preparation were also contaminated. Of the samples taken from the collection bags used during hip arthroplasty, 20% grew bacteria, which represents a significant microbial reservoir. Also, 17% of theatre gowns were contaminated at the end of the operation. Contamination was found in 10% of the needles used during closure of the fascia. Overall, 76% of the organisms grown were coagulase-negative staphylococcus. A total of 63% of operations showed contamination in the field of operation. Some changes in practice are suggested. Follow-up for a minimum of two years revealed one deep infection but the organism was not identified as a contaminant. These data provide a baseline for studying the bacteriology of the surgery of revision arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 971 - 975
1 Nov 1998
McCaskie AW Deehan DJ Green TP Lock KR Thompson JR Harper WM Gregg PJ

Early implants for total knee replacement were fixed to bone with cement. No firm scientific reason has been given for the introduction of cementless knee replacement and the long-term survivorship of such implants has not shown any advantage over cemented forms. In a randomised, prospective study we have compared cemented and uncemented total knee replacement and report the results of 139 prostheses at five years. Outcome was assessed both clinically by independent examination using the Nottingham knee score and radiologically using the Knee Society scoring system. Independent statistical analysis of the data showed no significant difference between cemented and cementless fixation for pain, mobility or movement. There was no difference in the radiological alignment at five years, but there was a notable disparity in the radiolucent line score. With cemented fixation there was a significantly greater number of radiolucent lines on anteroposterior radiographs of the tibia and lateral radiographs of the femur. At five years, our clinical results would not support the use of the more expensive cementless fixation whereas the radiological results are of unknown significance. Longer follow-up will determine any changes in the results and conclusions


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 565 - 572
1 May 2019
Teeter MG Marsh JD Howard JL Yuan X Vasarhelyi EM McCalden RW Naudie DDR

Aims

The purpose of the present study was to compare patient-specific instrumentation (PSI) and conventional surgical instrumentation (CSI) for total knee arthroplasty (TKA) in terms of early implant migration, alignment, surgical resources, patient outcomes, and costs.

Patients and Methods

The study was a prospective, randomized controlled trial of 50 patients undergoing TKA. There were 25 patients in each of the PSI and CSI groups. There were 12 male patients in the PSI group and seven male patients in the CSI group. The patients had a mean age of 69.0 years (sd 8.4) in the PSI group and 69.4 years (sd 8.4) in the CSI group. All patients received the same TKA implant. Intraoperative surgical resources and any surgical waste generated were recorded. Patients underwent radiostereometric analysis (RSA) studies to measure femoral and tibial component migration over two years. Outcome measures were recorded pre- and postoperatively. Overall costs were calculated for each group.


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1033 - 1042
1 Aug 2018
Kayani B Konan S Pietrzak JRT Huq SS Tahmassebi J Haddad FS

Aims

The primary aim of this study was to determine the surgical team’s learning curve for introducing robotic-arm assisted unicompartmental knee arthroplasty (UKA) into routine surgical practice. The secondary objective was to compare accuracy of implant positioning in conventional jig-based UKA versus robotic-arm assisted UKA.

Patients and Methods

This prospective single-surgeon cohort study included 60 consecutive conventional jig-based UKAs compared with 60 consecutive robotic-arm assisted UKAs for medial compartment knee osteoarthritis. Patients undergoing conventional UKA and robotic-arm assisted UKA were well-matched for baseline characteristics including a mean age of 65.5 years (sd 6.8) vs 64.1 years (sd 8.7), (p = 0.31); a mean body mass index of 27.2 kg.m2 (sd 2.7) vs 28.1 kg.m2 (sd 4.5), (p = 0.25); and gender (27 males: 33 females vs 26 males: 34 females, p = 0.85). Surrogate measures of the learning curve were prospectively collected. These included operative times, the Spielberger State-Trait Anxiety Inventory (STAI) questionnaire to assess preoperative stress levels amongst the surgical team, accuracy of implant positioning, limb alignment, and postoperative complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 983 - 989
1 Nov 1998
Murray DW Goodfellow JW O’Connor JJ

Retrieval studies have shown that the use of fully congruent meniscal bearings reduces wear in knee replacements. We report the outcome of 143 knees with anteromedial osteoarthritis and normal anterior cruciate ligaments treated by unicompartmental arthroplasty using fully congruous mobile polyethylene bearings. At review, 34 knees were in patients who had died and 109 were in those who were still living. The mean elapsed time since operation was 7.6 years (maximum 13.8). We established the status of all but one knee. There had been five revision operations giving a cumulative prosthetic survival rate at ten years (33 knees at risk) of 98% (95% CI 93% to 100%). Considering the knee lost to follow-up as a failure, the ‘worst-case’ survival rate was 97%. No failures were due to polyethylene wear or aseptic loosening of the tibial component. One bearing which dislocated at four years was reduced by closed manipulation. The ten-year survival rate is the best of those reported for unicompartmental arthroplasty and not significantly different from the best rates for total knee replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 3 | Pages 355 - 361
1 May 1984
Lettin A Kavanagh T Craig D Scales J

We review 210 Stanmore knee replacements in 163 patients to assess the survival of the prostheses and the long-term results. The annual rate of failure reached a maximum of 4.6% in the fourth year after operation; thereafter it declined to reach zero by the eighth year. Between two and eight years after operation, 66.3% of the surviving knees were completely free of pain and 30.2% had mild retropatellar pain. Fixed flexion deformities present before operation were completely corrected in 73% of the knees, and varus or valgus deformities were invariably corrected. Stability was always restored to unstable knees and 80.8% of knees flexed to 90 degrees or more after replacement. Aseptic loosening (8.1%), prosthetic infection (4.3%) and femoral fracture (2.9%) led to 8.5% of the prostheses being revised or removed over eight years. Modifications in prosthetic design and operative techniques have been introduced to minimise such complications in the future


Bone & Joint Research
Vol. 7, Issue 12 | Pages 639 - 649
1 Dec 2018
MacLeod AR Serrancoli G Fregly BJ Toms AD Gill HS

Objectives

Opening wedge high tibial osteotomy (HTO) is an established surgical procedure for the treatment of early-stage knee arthritis. Other than infection, the majority of complications are related to mechanical factors – in particular, stimulation of healing at the osteotomy site. This study used finite element (FE) analysis to investigate the effect of plate design and bridging span on interfragmentary movement (IFM) and the influence of fracture healing on plate stress and potential failure.

Materials and Methods

A 10° opening wedge HTO was created in a composite tibia. Imaging and strain gauge data were used to create and validate FE models. Models of an intact tibia and a tibia implanted with a custom HTO plate using two different bridging spans were validated against experimental data. Physiological muscle forces and different stages of osteotomy gap healing simulating up to six weeks postoperatively were then incorporated. Predictions of plate stress and IFM for the custom plate were compared against predictions for an industry standard plate (TomoFix).


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 53 - 56
1 Jan 1991
Barrett D Cobb A Bentley G

We measured joint position sense in the knee by a new method which tests the proprioceptive contribution of the joint capsule and ligaments. The leg was supported on a splint, and held in several positions of flexion. The subjects' perception of the position was recorded on a visual analogue model and compared with the actual angle of flexion. Eighty-one normal and 45 osteoarthritic knees were examined, as were 10 knees with semi-constrained and 11 with hinged joint replacements. All were assessed with and without an elastic bandage around the knee. There was a steady decline in joint position sense with age in subjects with normal knees. Those with osteoarthritic knees had impaired joint position sense at all ages (p less than 0.001). Knee replacement improved the joint position sense slightly (p less than 0.02); semi-constrained replacement had a greater effect than hinged replacement. The effect of an elastic bandage in subjects with poor position sense was dramatic, improving accuracy by 40% (p less than 0.001). It is proposed that reduced proprioception in elderly and osteoarthritic subjects may be responsible for initiation or advancement of degeneration of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 111 - 116
1 Jan 1986
Walker S Sharma P Parr N Cavendish M

We have reviewed 105 Liverpool Mark II knee replacements in 71 patients to assess survival and long-term results. Assessment was both clinical and radiological, using a modification of the British Orthopaedic Association knee function assessment chart, and analysis was by the survivorship method as advocated by Tew and Waugh. The follow-up period was between 13 and 113 months with 42 prostheses being in situ for over six years. Eight knees (7.6%) have been revised or arthrodesed because of infection or loosening, giving a cumulative success rate of 89% after seven years based on prosthesis survival alone. Of the remaining knees, 71.1% were either free of pain or caused only minimal pain. The cumulative success rate as judged by the stricter criteria of the prosthesis being in situ and causing little or no pain suggested a 50% survival between 73 and 96 months. Most patients (77.3%) were enthusiastic or satisfied with their results. Complications included deep wound infection (8.6%), and loosening which needed further surgery (11.4%)


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 4 | Pages 523 - 528
1 Aug 1984
Tibrewal S Grant K Goodfellow J

Radiolucent lines at the bone-cement interface beneath the tibial components were assessed in 91 consecutive Oxford meniscal knee replacements in 78 patients. Of 80 knees in which radio-opaque cement was used, a radiolucent line was observed in 77, with a radiodense line in the bone immediately adjoining. Radiolucent lines developed in the majority of patients within one year after operation. In 11 knees fixed with radiolucent cement (which precluded assessment of the radiolucent line) a radiodense line was observed beneath the lucent cement in all cases. Histological examination of the interface obtained from secure tibial components showed the lucent zone to be composed of fibrocartilaginous connective tissue and the radiodense line to be a thick lamella of bone. It is suggested that the living bone under a rigid prosthesis requires a layer of relatively compliant fibrocartilaginous material at its interface to accommodate load-bearing. Attention is drawn to the importance of the radiodense line: its presence may constitute positive evidence that healing at the level of bone section is complete and that equilibrium is established; its absence at a mature interface may indicate disequilibrium and impending failure


Bone & Joint 360
Vol. 7, Issue 4 | Pages 12 - 15
1 Aug 2018


Bone & Joint 360
Vol. 7, Issue 3 | Pages 14 - 16
1 Jun 2018


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 236 - 241
1 Mar 1995
Kim Y Oh J Oh S

We report the incidence of osteolysis in the femur, tibia, and patella of 44 consecutive patients (60 knees) who were followed for more than seven years after cementless knee arthroplasty with a Porous-Coated Anatomic prosthesis. The average age of the patients was 56.5 years (17 to 73); the operative diagnosis was osteoarthritis (33 knees), rheumatoid arthritis (17), tuberculous arthritis (7) and post-traumatic arthritis (3). All patellae were resurfaced. No femoral or tibial component was loose at the final follow-up examination. Thirty patellar components were loose of which six had been revised. Radiographs revealed osteolysis in 90% of the tibial plateaux and in 80% of the 30 intact patellar prostheses. No osteolysis was seen around any femoral component. In 50 knees (83%) the average wear of the polyethylene liner was 2.5 mm in the medial compartment and 1.7 mm in the lateral compartment. Four of 60 knees (6.7%) were revised for complete wear of the polyethylene liner of the tibial component. Fixation of the tibial and patellar components without cement fails to seal the interface between bone and prosthesis and allows the migration of polyethylene particulate debris which causes osteolysis


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 415 - 425
1 Apr 2019
Thewlis D Bahl JS Fraysse F Curness K Arnold JB Taylor M Callary S Solomon LB

Aims

The purpose of this exploratory study was to investigate if the 24-hour activity profile (i.e. waking activities and sleep) objectively measured using wrist-worn accelerometry of patients scheduled for total hip arthroplasty (THA) improves postoperatively.

Patients and Methods

A total of 51 THA patients with a mean age of 64 years (24 to 87) were recruited from a single public hospital. All patients underwent THA using the same surgical approach with the same prosthesis type. The 24-hour activity profiles were captured using wrist-worn accelerometers preoperatively and at 2, 6, 12, and 26 weeks postoperatively. Patient-reported outcomes (Hip Disability and Osteoarthritis Outcome Score (HOOS)) were collected at all timepoints except two weeks postoperatively. Accelerometry data were used to quantify the intensity (sedentary, light, moderate, and vigorous activities) and frequency (bouts) of activity during the day and sleep efficiency. The analysis investigated changes with time and differences between Charnley class.