Advertisement for orthosearch.org.uk
Results 1041 - 1060 of 1492
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 492 - 497
1 Apr 2015
Ike H Inaba Y Kobayashi N Yukizawa Y Hirata Y Tomioka M Saito T

In this study we used subject-specific finite element analysis to investigate the mechanical effects of rotational acetabular osteotomy (RAO) on the hip joint and analysed the correlation between various radiological measurements and mechanical stress in the hip joint.

We evaluated 13 hips in 12 patients (two men and ten women, mean age at surgery 32.0 years; 19 to 46) with developmental dysplasia of the hip (DDH) who were treated by RAO.

Subject-specific finite element models were constructed from CT data. The centre–edge (CE) angle, acetabular head index (AHI), acetabular angle and acetabular roof angle (ARA) were measured on anteroposterior pelvic radiographs taken before and after RAO. The relationship between equivalent stress in the hip joint and radiological measurements was analysed.

The equivalent stress in the acetabulum decreased from 4.1 MPa (2.7 to 6.5) pre-operatively to 2.8 MPa (1.8 to 3.6) post-operatively (p < 0.01). There was a moderate correlation between equivalent stress in the acetabulum and the radiological measurements: CE angle (R = –0.645, p < 0.01); AHI (R = –0.603, p < 0.01); acetabular angle (R = 0.484, p = 0.02); and ARA (R = 0.572, p < 0.01).

The equivalent stress in the acetabulum of patients with DDH decreased after RAO. Correction of the CE angle, AHI and ARA was considered to be important in reducing the mechanical stress in the hip joint.

Cite this article: Bone Joint J 2015;97-B:492–7.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 150 - 153
1 Feb 2015
Rogers BA Alolabi B Carrothers AD Kreder HJ Jenkinson RJ

In this study we evaluated whether pre-operative Western Ontario and McMaster Universities (WOMAC) osteoarthritis scores can predict satisfaction following total hip arthroplasty (THA). Prospective data for a cohort of patients undergoing THA from two large academic centres were collected, and pre-operative and one-year post-operative WOMAC scores and a 25-point satisfaction questionnaire were obtained for 446 patients. Satisfaction scores were dichotomised into either improvement or deterioration. Scatter plots and Spearman’s rank correlation coefficient were used to describe the association between pre-operative WOMAC and one-year post-operative WOMAC scores and patient satisfaction. Satisfaction was compared using receiver operating characteristic (ROC) analysis against pre-operative, post-operative and δ WOMAC scores.

We found no relationship between pre-operative WOMAC scores and one-year post-operative WOMAC or satisfaction scores, with Spearman’s rank correlation coefficients of 0.16 and –0.05, respectively. The ROC analysis showed areas under the curve (AUC) of 0.54 (pre-operative WOMAC), 0.67 (post-operative WOMAC) and 0.43 (δ WOMAC), respectively, for an improvement in satisfaction.

We conclude that the pre-operative WOMAC score does not predict the post-operative WOMAC score or patient satisfaction after THA, and that WOMAC scores can therefore not be used to prioritise patient care.

Cite this article: Bone Joint J 2015;97-B:150–3.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 290 - 294
1 Mar 2013
MacLeod K Lingham A Chatha H Lewis J Parkes A Grange S Smitham PJ

Clinicians are often asked by patients, “When can I drive again?” after lower limb injury or surgery. This question is difficult to answer in the absence of any guidelines. This review aims to collate the currently available evidence and discuss the factors that influence the decision to allow a patient to return to driving. Medline, Web of Science, Scopus, and EMBASE were searched using the following terms: ‘brake reaction time’, ‘brake response time’, ‘braking force’, ‘brake pedal force’, ‘resume driving’, ‘rate of application of force’, ‘driving after injury’, ‘joint replacement and driving’, and ‘fracture and driving’. Of the relevant literature identified, most studies used the brake reaction time and total brake time as the outcome measures. Varying recovery periods were proposed based on the type and severity of injury or surgery. Surveys of the Driver and Vehicle Licensing Agency, the Police, insurance companies in the United Kingdom and Orthopaedic Surgeons offered a variety of opinions.

There is currently insufficient evidence for any authoritative body to determine fitness to drive. The lack of guidance could result in patients being withheld from driving for longer than is necessary, or returning to driving while still unsafe.

Cite this article: Bone Joint J 2013;95-B:290–4.


Bone & Joint 360
Vol. 2, Issue 6 | Pages 1 - 1
1 Dec 2013
Ollivere BJ


Bone & Joint 360
Vol. 4, Issue 1 | Pages 26 - 28
1 Feb 2015

The February 2015 Trauma Roundup360 looks at: Evaluating the syndesmosis in ankle fractures; Calcaneal fracture management an ongoing problem; Angular stable locking in low tibial fractures did not improve results; Open fractures: do the seconds really count?; Long-term outcomes of tibial fractures; Targeted performance improvements in pelvic fractures


Bone & Joint 360
Vol. 4, Issue 1 | Pages 18 - 20
1 Feb 2015

The February 2015 Foot & Ankle Roundup360 looks at: Syndesmosis screw removal in randomised controlled trial; Diagnostic value of Hawkins sign; Chevron rules supreme?; Diabetes and ankle replacement; Fixed-bearing ankle replacement; Fusion for osteomyelitis of the ankle; ‘Reformed’ fallers.


Bone & Joint Research
Vol. 4, Issue 5 | Pages 84 - 92
1 May 2015
Hamamura K Nishimura A Iino T Takigawa S Sudo A Yokota H

Objectives

Salubrinal is a synthetic agent that elevates phosphorylation of eukaryotic translation initiation factor 2 alpha (eIF2α) and alleviates stress to the endoplasmic reticulum. Previously, we reported that in chondrocytes, Salubrinal attenuates expression and activity of matrix metalloproteinase 13 (MMP13) through downregulating nuclear factor kappa B (NFκB) signalling. We herein examine whether Salubrinal prevents the degradation of articular cartilage in a mouse model of osteoarthritis (OA).

Methods

OA was surgically induced in the left knee of female mice. Animal groups included age-matched sham control, OA placebo, and OA treated with Salubrinal or Guanabenz. Three weeks after the induction of OA, immunoblotting was performed for NFκB p65 and p-NFκB p65. At three and six weeks, the femora and tibiae were isolated and the sagittal sections were stained with Safranin O.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 868 - 875
1 Jul 2014
Lübbeke A Gonzalez A Garavaglia G Roussos C Bonvin A Stern R Peter R Hoffmeyer P

Large-head metal-on-metal (MoM) total hip replacements (THR) have given rise to concern. Comparative studies of small-head MoM THRs over a longer follow-up period are lacking. Our objective was to compare the incidence of complications such as infection, dislocation, revision, adverse local tissue reactions, mortality and radiological and clinical outcomes in small-head (28 mm) MoM and ceramic-on-polyethylene (CoP) THRs up to 12 years post-operatively.

A prospective cohort study included 3341 THRs in 2714 patients. The mean age was 69.1 years (range 24 to 98) and 1848 (55.3%) were performed in women, with a mean follow-up of 115 months (18 to 201). There were 883 MoM and 2458 CoP bearings. Crude incidence rates (cases/1000 person-years) were: infection 1.3 vs 0.8; dislocation 3.3 vs 3.1 and all-cause revision 4.3 vs 2.2, respectively. There was a significantly higher revision rate after ten years (adjusted hazard ratio 9.4; 95% CI 2.6 to 33.6) in the MoM group, and ten of 26 patients presented with an adverse local tissue reaction at revision. No differences in mortality, osteolysis or clinical outcome were seen.

In conclusion, we found similar results for small-head MoM and CoP bearings up to ten years post-operatively, but after ten years MoM THRs had a higher risk of all-cause revision. Furthermore, the presence of an adverse response to metal debris seen in the small-head MOM group at revision is a cause for concern.

Cite this article: Bone Joint J 2014; 96-B:868–75.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 793 - 801
1 Jun 2015
Liddle AD Pandit H Judge A Murray DW

Whether to use total or unicompartmental knee replacement (TKA/UKA) for end-stage knee osteoarthritis remains controversial. Although UKA results in a faster recovery, lower rates of morbidity and mortality and fewer complications, the long-term revision rate is substantially higher than that for TKA. The effect of each intervention on patient-reported outcome remains unclear. The aim of this study was to determine whether six-month patient-reported outcome measures (PROMs) are better in patients after TKA or UKA, using data from a large national joint registry (NJR).

We carried out a propensity score-matched cohort study which compared six-month PROMs after TKA and UKA in patients enrolled in the NJR for England and Wales, and the English national PROM collection programme. A total of 3519 UKA patients were matched to 10 557 TKAs.

The mean six-month PROMs favoured UKA: the Oxford Knee Score was 37.7 (95% confidence interval (CI) 37.4 to 38.0) for UKA and 36.1 (95% CI 35.9 to 36.3) for TKA; the mean EuroQol EQ-5D index was 0.772 (95% CI 0.764 to 0.780) for UKA and 0.751 (95% CI 0.747 to 0.756) for TKA. UKA patients were more likely to achieve excellent results (odds ratio (OR) 1.59, 95% CI 1.47 to 1.72, p < 0.001) and to be highly satisfied (OR 1.27, 95% CI 1.17 to 1.39, p <  0.001), and were less likely to report complications than those who had undergone TKA.

UKA gives better early patient-reported outcomes than TKA; these differences are most marked for the very best outcomes. Complications and readmission are more likely after TKA. Although the data presented reflect the short-term outcome, they suggest that the high revision rate for UKA may not be because of poorer clinical outcomes. These factors should inform decision-making in patients eligible for either procedure.

Cite this article: Bone Joint J 2015;97-B:793–801.


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 442 - 448
1 Apr 2015
Kosuge D Barry M

The management of children’s fractures has evolved as a result of better health education, changes in lifestyle, improved implant technology and the changing expectations of society. This review focuses on the changes seen in paediatric fractures, including epidemiology, the increasing problems of obesity, the mechanisms of injury, non-accidental injuries and litigation. We also examine the changes in the management of fractures at three specific sites: the supracondylar humerus, femoral shaft and forearm. There has been an increasing trend towards surgical stabilisation of these fractures. The reasons for this are multifactorial, including societal expectations of a perfect result and reduced hospital stay. Reduced hospital stay is beneficial to the social, educational and psychological needs of the child and beneficial to society as a whole, due to reduced costs.

Cite this article: Bone Joint J 2015; 97-B:442–8.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 442 - 448
1 Apr 2014
Feyen H Shimmin AJ

Many different lengths of stem are available for use in primary total hip replacement, and the morphology of the proximal femur varies greatly. The more recently developed shortened stems provide a distribution of stress which closely mimics that of the native femur. Shortening the femoral component potentially comes at the cost of decreased initial stability. Clinical studies on the performance of shortened cemented and cementless stems are promising, although long-term follow-up studies are lacking. We provide an overview of the current literature on the anatomical features of the proximal femur and the biomechanical aspects and clinical outcomes associated with the length of the femoral component in primary hip replacement, and suggest a classification system for the length of femoral stems.

Cite this article: Bone Joint J 2014;96-B:442-8.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 265 - 269
1 Feb 2015
Mace J Paton RW

Over a 15-year prospective period, 201 infants with a clinically unstable hip at neonatal screening were subsequently reviewed in a ‘one stop’ clinic where they were assessed clinically and sonographically. Their mean age was 1.62 weeks (95% confidence interval (CI) 1.35 to 1.89). Clinical neonatal hip screening revealed a sensitivity of 62% (mean, 62.6 95%CI 50.9 to 74.3), specificity of 99.8% (mean, 99.8, 95% CI 99.7 to 99.8) and positive predictive value (PPV) of 24% (mean, 26.2, 95% CI 19.3 to 33.0). Static and dynamic sonography for Graf type IV dysplastic hips had a 15-year sensitivity of 77% (mean, 75.8 95% CI 66.9 to 84.6), specificity of 99.8% (mean, 99.8, 95% CI 99.8 to 99.8) and a PPV of 49% (mean, 55.1, 95% CI 41.6 to 68.5). There were 36 infants with an irreducible dislocation of the hip (0.57 per 1000 live births), including six that failed to resolve with neonatal splintage.

Most clinically unstable hips referred to a specialist clinic are female and stabilise spontaneously. Most irreducible dislocations are not identified from this neonatal instability group. There may be a small subgroup of females with instability of the hip which may be at risk of progression to irreducibility despite early treatment in a Pavlik harness.

A controlled study is required to assess the value of neonatal clinical screening programmes.

Cite this article: Bone Joint J 2015;97-B:265-9.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 548 - 554
1 Apr 2014
Sun H Luo CF Zhong B Shi HP Zhang CQ Zeng BF

Our aim was to compare polylevolactic acid screws with titanium screws when used for fixation of the distal tibiofibular syndesmosis at mid-term follow-up. A total of 168 patients, with a mean age of 38.5 years (18 to 72) who were randomly allocated to receive either polylevolactic acid (n = 86) or metallic (n = 82) screws were included. The Baird scoring system was used to assess the overall satisfaction and functional recovery post-operatively. The demographic details and characteristics of the injury were similar in the two groups. The mean follow-up was 55.8 months (48 to 66). The Baird scores were similar in the two groups at the final follow-up. Patients in the polylevolactic acid group had a greater mean dorsiflexion (p = 0.011) and plantar-flexion of the injured ankles (p < 0.001). In the same group, 18 patients had a mild and eight patients had a moderate foreign body reaction. In the metallic groups eight had mild and none had a moderate foreign body reaction (p <  0.001). In total, three patients in the polylevolactic acid group and none in the metallic group had heterotopic ossification (p = 0.246).

We conclude that both screws provide adequate fixation and functional recovery, but polylevolactic acid screws are associated with a higher incidence of foreign body reactions.

Cite this article: Bone Joint J 2014;96-B:548–54.


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 503 - 509
1 Apr 2015
Maempel JF Clement ND Brenkel IJ Walmsley PJ

This study demonstrates a significant correlation between the American Knee Society (AKS) Clinical Rating System and the Oxford Knee Score (OKS) and provides a validated prediction tool to estimate score conversion.

A total of 1022 patients were prospectively clinically assessed five years after TKR and completed AKS assessments and an OKS questionnaire. Multivariate regression analysis demonstrated significant correlations between OKS and the AKS knee and function scores but a stronger correlation (r = 0.68, p < 0.001) when using the sum of the AKS knee and function scores. Addition of body mass index and age (other statistically significant predictors of OKS) to the algorithm did not significantly increase the predictive value.

The simple regression model was used to predict the OKS in a group of 236 patients who were clinically assessed nine to ten years after TKR using the AKS system. The predicted OKS was compared with actual OKS in the second group. Intra-class correlation demonstrated excellent reliability (r = 0.81, 95% confidence intervals 0.75 to 0.85) for the combined knee and function score when used to predict OKS.

Our findings will facilitate comparison of outcome data from studies and registries using either the OKS or the AKS scores and may also be of value for those undertaking meta-analyses and systematic reviews.

Cite this article: Bone Joint J 2015;97-B:503–9.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1209 - 1216
1 Sep 2013
van der Voort P Pijls BG Nouta KA Valstar ER Jacobs WCH Nelissen RGHH

Mobile-bearing (MB) total knee replacement (TKR) was introduced to reduce the risk of aseptic loosening and wear of polyethylene inserts. However, no consistent clinical advantages of mobile- over fixed-bearing (FB) TKR have been found. In this study we evaluated whether mobile bearings have an advantage over fixed bearings with regard to revision rates and clinical outcome scores. Furthermore, we determined which modifying variables affected the outcome.

A systematic search of the literature was conducted to collect clinical trials comparing MB and FB in primary TKR. The primary outcomes were revision rates for any reason, aseptic loosening and wear. Secondary outcomes included range of movement, Knee Society score (KSS), Oxford knee score (OKS), Short-Form 12 (SF-12) score and radiological parameters. Meta-regression techniques were used to explore factors modifying the observed effect.

Our search yielded 1827 publications, of which 41 studies met our inclusion criteria, comprising over 6000 TKRs. Meta-analyses showed no clinically relevant differences in terms of revision rates, clinical outcome scores or patient-reported outcome measures between MB and FB TKRs. It appears that theoretical assumptions of superiority of MB over FB TKR are not borne out in clinical practice.

Cite this article: Bone Joint J 2013;95-B:1209–16.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 141 - 144
1 Jan 2015
Hughes AW Clark D Carlino W Gosling O Spencer RF

Reported rates of dislocation in hip hemiarthroplasty (HA) for the treatment of intra-capsular fractures of the hip, range between 1% and 10%. HA is frequently performed through a direct lateral surgical approach. The aim of this study is to determine the contribution of the anterior capsule to the stability of a cemented HA through a direct lateral approach.

A total of five whole-body cadavers were thawed at room temperature, providing ten hip joints for investigation. A Thompson HA was cemented in place via a direct lateral approach. The cadavers were then positioned supine, both knee joints were disarticulated and a digital torque wrench was attached to the femur using a circular frame with three half pins. The wrench applied an external rotation force with the hip in extension to allow the hip to dislocate anteriorly. Each hip was dislocated twice; once with a capsular repair and once without repairing the capsule. Stratified sampling ensured the order in which this was performed was alternated for the paired hips on each cadaver.

Comparing peak torque force in hips with the capsule repaired and peak torque force in hips without repair of the capsule, revealed a significant difference between the ‘capsule repaired’ (mean 22.96 Nm, standard deviation (sd) 4.61) and the ‘capsule not repaired’ group (mean 5.6 Nm, sd 2.81) (p < 0.001). Capsular repair may help reduce the risk of hip dislocation following HA.

Cite this article: Bone Joint J 2015;97-B:141–4.


Bone & Joint 360
Vol. 3, Issue 1 | Pages 17 - 20
1 Feb 2014

The February 2014 Knee Roundup360 looks at: whether sham surgery is as good as arthroscopic meniscectomy; distraction in knee osteoarthritis; whether trans-tibial tunnel placement increases the risk of graft failure in ACL surgery; whether joint replacements prevent cardiac events; the size of the pulmonary embolism problem; tranexamic acid and knee replacement haemostasis; matching the demand for knee replacement and follow-up; predicting the length of stay after knee replacement; and popliteal artery injury in TKR.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 63 - 66
1 Nov 2013
Rodriguez JA Cooper HJ

Large ceramic femoral heads offer several advantages that are potentially advantageous to patients undergoing both primary and revision total hip replacement. Many high-quality studies have demonstrated the benefit of large femoral heads in reducing post-operative instability. Ceramic femoral heads may also offer an advantage in reducing polyethylene wear that has been reported in vitro and is starting to become clinically apparent in mid-term clinical outcome studies. Additionally, the risk of taper corrosion at a ceramic femoral head–neck junction is clearly lower than when using a metal femoral head. With improvements in the material properties of both modern ceramic femoral heads and polyethylene acetabular liners that have reduced the risk of mechanical complications, large ceramic heads have gained popularity in recent years.

Cite this article: Bone Joint J 2013;95-B, Supple A:63–6.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 181 - 187
1 Feb 2014
Owen DH Russell NC Smith PN Walter WL

Squeaking arising from a ceramic-on-ceramic (CoC) total hip replacement (THR) may cause patient concern and in some cases causes patients to seek revision surgery. We performed a meta-analysis to determine the incidence of squeaking and the incidence of revision surgery for squeaking. A total of 43 studies including 16 828 CoC THR that reported squeaking, or revision for squeaking, were entered into the analysis. The incidence of squeaking was 4.2% and the incidence of revision for squeaking was 0.2%. The incidence of squeaking in patients receiving the Accolade femoral stem was 8.3%, and the incidence of revision for squeaking in these patients was 1.3%.

Cite this article: Bone Joint J 2014;96-B:181–7.


Bone & Joint 360
Vol. 3, Issue 6 | Pages 39 - 40
1 Dec 2014
Foy MA