The aim of this study was to evaluate the prosthesis characteristics and associated conditions that may modify the survival of total femoral endoprosthetic replacements (TFEPR). In all, 81 patients treated with TFEPR from 1976 to 2017 were retrospectively evaluated and failures were categorized according to the Henderson classification. There were 38 female patients (47%) and 43 male patients (53%) with a mean age at diagnosis of 43 years (12 to 86). The mean follow-up time was 10.3 years (0 to 31.7). A survival analysis was performed followed by univariate and multivariate Cox regression to identify independent implant survival factors.Aims
Patients and Methods
Improvement in the life expectancy of patients with primary bone tumours has led to increased emphasis on limb salvage and preservation of function. Between 1979 and 1994 we used custom-made endoprostheses in 18 patients to reconstruct diaphyseal defects after excision of primary bone tumours. The mean age at operation was 26 years (9 to 64) and the median follow-up 65 months (6 to 188). Fifteen patients have survived and are free from local or metastatic disease. Local recurrence developed in one patient. Using the modified Enneking functional scoring system, 77% of the patients achieved 80% or more of their premorbid functional capability. Mechanical loosening, limb shortening and secondary osteoarthritis were the main complications. There were no infections. We conclude that diaphyseal endoprostheses offer a good clinical and
Severe acetabular bone loss and pelvic discontinuity (PD) present particular challenges in revision total hip arthroplasty. To deal with such complex situations, cup-cage reconstruction has emerged as an option for treating this situation. We aimed to examine our success in using this technique for these anatomical problems. We undertook a retrospective, single-centre series of 35 hips in 34 patients (seven male, 27 female) treated with a cup-cage construct using a trabecular metal shell in conjunction with a titanium cage, for severe acetabular bone loss between 2011 and 2015. The mean age at the time of surgery was 70 years (42 to 85) and all patients had an acetabular defect graded as Paprosky Type 2C through to 3B, with 24 hips (69%) having PD. The mean follow-up was 47 months (25 to 84).Aims
Patients and Methods
Abnormal sagittal kinematics after total knee replacement (TKR) can adversely affect
In a prospective, randomised study we have compared the pertrochanteric external fixator (PF) with the sliding hip screw (SHS) in 100 consecutive patients who were allocated randomly to the two methods of treatment. Details of the patients and the patterns of fracture were similar in both groups. Follow-up was for six months. Use of the PF was associated with significantly less blood loss, a shorter operating time, reduced postoperative pain, shorter hospitalisation (p <
0.001), earlier mobilisation (p <
0.001) and a reduced rate of mechanical complications (p <
0.01). Superficial infection was significantly more common with the PF (p <
0.01), but without long-term adverse consequences. There were no differences in the healing of the fracture, mortality or final
The Ilizarov apparatus was used to carry out opening-wedge callotasis of the proximal tibia in ten patients who had suffered premature asymmetrical closure of the proximal tibial physis and subsequent genu recurvatum. In four knees, the genu recurvatum was entirely due to osseous deformity, whereas in six it was associated with capsuloligamentous abnormality. Preoperatively, the angle of recurvatum averaged 19.6° (15 to 26), the angle of tilt of the tibial plateau, 76.6° (62 to 90), and the ipsilateral limb shortening, 2.7 cm (0.5 to 8.7). The average time for correction was 49 days (23 to 85). The average duration of external fixation was 150 days (88 to 210). Three patients suffered complications including patella infera, pin-track infection and transient peroneal nerve palsy. At a mean follow-up of 4.4 years, all patients, except one, had achieved an excellent or good radiological and
We have performed endoprosthetic replacement after resection of tumours of the proximal tibia on 151 patients over a period of 20 years. During this period limb-salvage surgery was achieved in 88% of patients with tumours of the proximal tibia. Both the implant and the operative technique have been gradually modified in order to reduce complications. An initial rate of infection of 36% has been reduced to 12% by the use of a flap of the medial gastrocnemius, to which the divided patellar tendon is attached. Loosening and breakage of the implant have been further causes of failure. We found that the probability of further surgical procedures being required was 70% at ten years and the risk of amputation, 25%. The development of a new rotating hinge endoprosthesis may lower the incidence of mechanical problems. Limb salvage for tumours of the proximal tibia is fraught with complications, but the good
We report the results of a prospective randomised controlled trial of the management of 101 Colles' fractures in patients over the age of 55 years. Within two weeks of initial reduction 43 fractures had displaced with either more than 10 degrees dorsal angulation or more than 5 mm radial shortening. These patients were randomly divided into two groups: 21 were remanipulated and held by an external fixator; in the control group of 22 patients, the redisplacement was accepted and conservative treatment was continued. Patients treated with external fixation had a good anatomical result, but their function was no better than that of the control group. We found no correlation between final anatomical and
The primary objective of this study was to compare accuracy in restoring the native centre of hip rotation in patients undergoing conventional manual total hip arthroplasty (THA) This prospective cohort study included 50 patients undergoing conventional manual THA and 25 patients receiving robotic-arm assisted THA. Patients undergoing conventional manual THA and robotic-arm assisted THA were well matched for age (mean age, 69.4 years (Objectives
Materials and Methods
The aim of this study was to report the outcome of femoral condylar fresh osteochondral allografts (FOCA) with concomitant realignment osteotomy with a focus on graft survivorship, complications, reoperation, and function. We identified 60 patients (16 women, 44 men) who underwent unipolar femoral condylar FOCA with concomitant realignment between 1972 and 2012. The mean age of the patients was 28.9 years (10 to 62) and the mean follow-up was 11.4 years (2 to 35). Failure was defined as conversion to total knee arthroplasty, revision allograft, or graft removal. Clinical outcome was evaluated using the modified Hospital for Special Surgery (mHSS) score.Aims
Patients and Methods
We describe 24 fractures of the tuberosity of the calcaneus in 22 patients. Three were similar to the type of avulsion fracture which has been well-defined but the remainder represent a group which has been unrecognised previously. Using CT and operative findings we have defined the different patterns of fracture of the calcaneal tuberosity. Ten fractures extended into the subtalar joint, but did not fit the pattern of the common intra-articular fracture as described classically. We have defined a new pattern which consists of a fracture of the medial calcaneal process with a further fracture which separates the upper part of the tuberosity in the semicoronal plane. Non-operative treatment of displaced fractures resulted in a mis-shapen heel and a poor
Low-grade surface tumours of bone may theoretically be treated by hemicortical resection, retaining part of the circumference of the cortex. An inlay allograft may be used to reconstruct the defect. Since 1988 we have performed 22 hemicortical procedures in selected patients with low-grade parosteal osteosarcoma (6), peripheral chondrosarcoma (6) and adamantinoma (10). Restricted medullary involvement was not a contraindication for this procedure. There was no evidence of local recurrence or distant metastasis at a mean follow-up of 64 months (27 to 135). Wide resection margins were obtained in 19 patients. All allografts incorporated completely and there were no fractures or infections. Fractures of the remaining hemicortex occurred in six patients and were managed successfully by casts or by osteosynthesis. The functional results were excellent or good in all except one patient. Hemicortical procedures for selected cases of low-grade surface tumours give excellent oncological and
We assessed proprioception in the knee using the angle reproduction test in 20 healthy volunteers, ten patients with acute anterior instability and 20 patients with chronic anterior instability after reconstruction of the anterior cruciate ligament (ACL). In addition, the Lysholm-knee score, ligament laxity and patient satisfaction were determined. Acute trauma causes extensive damage to proprioception which is not restored by rehabilitation alone. Three months after operation, there remained a slight decrease in proprioception compared with the preoperative recordings, but six months after reconstruction, restoration of proprioception was seen near full extension and full flexion. In the mid-range position, proprioception was not restored. At follow-up, 3.7 ± 0.3 years after reconstruction, there was further improvement of proprioception in the mid-range position. There was no difference between open and arthroscopic techniques. The highest correlation was found between proprioception and patient satisfaction. After reconstruction of the ACL reduced proprioception may explain the poor
The hypothesis of this study was that thigh circumference, distinct from body mass index (BMI), may be associated with the positioning of components when undertaking total hip arthroplasty (THA) using the direct anterior approach (DAA), and that an increased circumference might increase the technical difficulty. We performed a retrospective review of prospectively collected data involving 155 consecutive THAs among 148 patients undertaken using the DAA at an academic medical centre by a single fellowship-trained surgeon. Preoperatively, thigh circumference was measured at 10 cm, 20 cm, and 30 cm distal to the anterior superior iliac spine, in quartiles. Two blinded reviewers assessed the inclination and anteversion of the acetabular component, radiological leg-length discrepancy, and femoral offset. The radiological outcomes were considered as continuous and binary outcome variables based on Lewinnek’s ‘safe zone’.Aims
Patients and Methods
We performed a prospective, randomised trial of 44 patients to compare the
Sacral insufficiency fractures are not uncommon in elderly patients. We have diagnosed 20 cases in a five-year period, and have reviewed the clinical records, radiographs, CT and bone scans. We also assessed the degree of osteoporosis by measuring bone density using dual-energy X-ray absorptiometry and bone histomorphometry, and monitored the patients'
There is ambiguity concerning the nomenclature and classification of fractures of the ring of the second cervical vertebra (C2). Disruption of the pars interarticularis which defines true traumatic spondylolisthesis of C2, is often wrongly called a pedicle fracture. Our aim in this study was to assess the influence of asymmetry on the anatomical and