Advertisement for orthosearch.org.uk
Results 1121 - 1140 of 2012
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 6 | Pages 876 - 886
1 Aug 2004
Albinana J Dolan LA Spratt KF Morcuende J Meyer MD Weinstein SL

Untreated acetabular dysplasia following treatment for developmental dysplasia of the hip (DDH) leads to early degenerative joint disease. Clinicians must accurately and reliably recognise dysplasia in order to intervene appropriately with secondary acetabular or femoral procedures. This study sought early predictors of residual dysplasia in order to establish empirically-based indications for treatment. DDH treated by closed or open reduction alone was reviewed. Residual hip dysplasia was defined according to the Severin classification at skeletal maturity. Future hip replacement in a subset of these patients was compared with the Severin classification. Serial measurements of acetabular development and subluxation of the femoral head were collected, as were the age at reduction, type of reduction, and Tonnis grade prior to reduction. These variables were used to predict the Severin classification. The mean age at reduction in 72 hips was 16 months (1 to 46). On the final radiograph, 47 hips (65%) were classified as Severin I/II, and 25 as Severin III/IV (35%). At 40 years after reduction, five of 43 hips (21%) had had a total hip replacement (THR). The Severin grade was predictive for THR. Early measurements of the acetabular index (AI) were predictive for Severin grade. For example, an AI of 35° or more at two years after reduction was associated with an 80% probability of becoming a Severin grade III/IV hip. This study links early acetabular remodelling, residual dysplasia at skeletal maturity and the long-term risk of THR. It presents evidence describing the diagnostic value of early predictors of residual dysplasia, and therefore, of the long-term risk of degenerative change


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 2 | Pages 176 - 183
1 May 1976
Solomon L

The division of osteoarthritis into primary and secondary varieties implies that these are aetiologically distinct entities, the former being due to some intrinsic defect of cartilage and the latter resulting from previous articular damage. This traditional concept is questioned and the hypothesis is advanced that osteoarthritis is always secondary to some underlying abnormality of the joint. A detailed clinical, radiographic and morbid anatomical study of 327 cases of osteoarthritis of the hip is presented. In all but twenty-seven some predisposing abnormality of the joint was diagnosed: 107 (33%) were associated with major pathology such as Perthes' disease or epiphysiolysis; minor acetabular dysplasia was present in sixty-seven (20%), with a male: female ratio of 1:10; minimal femoral head tilt was demonstrated in fifty-nine (18%), the male: female ratio being 14:1; and in forty-three (13%) there were features suggesting an underlying inflammatory arthritis. On the basis of this study a new classification is proposed and osteoarthritis of the hip is divided into three pathogenetic groups: 1) failure of essentially normal cartilage subjected to abnormal or incongruous loading for long periods; 2) damaged or defective cartilage failing under normal conditions of loading; 3) break-up of articular cartilage due to defective subchondral bone


The Journal of Bone & Joint Surgery British Volume
Vol. 30-B, Issue 1 | Pages 76 - 83
1 Feb 1948
Law WA

1. In this series of 150 cases of arthritis of the hip joint treated by vitallium mould arthroplasty (182 arthroplasties), 80 per cent. of late results are satisfactory to both patient and surgeon. 2. Striking features are the relative painlessness, smooth hip joint movement, progressive improvement in function, and reformation of the joint lines as seen radiographically in the post-operative period. 3. Function after arthroplasty for traumatic and degenerative arthritis approaches the normal hip joint much more closely than in cases of infective and rheumatoid arthritis. 4. There is a complete absence of low back symptoms or postural difficulties, and there is no difficulty in preventing stiffness of the knee joint. 5. Different technical procedures are indicated according to the degree of absorption of the femoral head or neck, and the stability of the mould in the acetabulum. 6. The operative mortality rate in this series was nil, and during the six-year follow-up period only one case died as the result of a complication of the arthroplasty. 7. In addition to meticulous operative technique and the use of special instruments, the importance of careful and prolonged after-treatment must be stressed. 8. It must also be emphasised that secondary operative revisions are often necessary, particularly in cases of infective and rheumatoid arthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 548 - 556
1 Jul 1995
Sugano N Nishii T Nakata K Masuhara K Takaoka K

From 1981 to 1983, we implanted Bioceram type-4 and type-5 prostheses in 61 hips in 54 patients with osteoarthritis secondary to acetabular dysplasia, congenital subluxation, or congenital dislocation of the hip. Fifty-seven hips in 50 patients were followed for a mean of 11.1 years (10 to 13). The mean age of the patients at operation was 53 years (31 to 70). Functional evaluation using the Merle d'Aubigne and Postel hip score showed a 77% success rate. Radiological loosening occurred in three femoral (5%) and 16 acetabular components (28%). Autologous femoral head grafts were used in 18 hips and became incorporated, giving mechanical support to the socket except for one which occupied a large weight-bearing area and eventually collapsed. The mean polyethylene wear was 1.1 mm (0 to 3.6) and the mean wear rate was 0.10 mm/year (0 to 0.31). A high rate of wear correlated with calcar resorption (p > 0.002) but not with acetabular loosening. There was no breakage of a ceramic head. Study of the ceramic heads and polyethylene sockets retrieved after ten years showed excellent surface roughness, sphericity, and bending strength for the heads but scratches and voids were seen on the sockets


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 17 - 21
1 Jan 2018
Konan S Duncan CP

Patients with neuromuscular imbalance who require total hip arthroplasty (THA) present particular technical problems due to altered anatomy, abnormal bone stock, muscular imbalance and problems of rehabilitation.

In this systematic review, we studied articles dealing with THA in patients with neuromuscular imbalance, published before April 2017. We recorded the demographics of the patients and the type of neuromuscular pathology, the indication for surgery, surgical approach, concomitant soft-tissue releases, the type of implant and bearing, pain and functional outcome as well as complications and survival.

Recent advances in THA technology allow for successful outcomes in these patients. Our review suggests excellent benefits for pain relief and good functional outcome might be expected with a modest risk of complication.

Cite this article: Bone Joint J 2018;100-B(1 Supple A):17–21.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 720 - 724
1 Jun 2018
Waterson HB Whitehouse MR Greidanus NV Garbuz DS Masri BA Duncan CP

Aims

Fretting and corrosion at the modular head/neck junction, known as trunnionosis, in total hip arthroplasty (THA) is a cause of adverse reaction to metal debris (ARMD). We describe the outcome of revision of metal-on-polyethylene (MoP) THA for ARMD due to trunnionosis with emphasis on the risk of major complications.

Patients and Methods

A total of 36 patients with a MoP THA who underwent revision for ARMD due to trunnionosis were identified. Three were excluded as their revision had been to another metal head. The remaining 33 were revised to a ceramic head with a titanium sleeve. We describe the presentation, revision findings, and risk of complications in these patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 295 - 301
1 Mar 2001
Kim Y Kim J Cho S

Six pairs of human cadaver femora were divided equally into two groups one of which received a non-cemented reference implant and the other a very short non-dependent experimental implant. Thirteen strain-gauge rosettes were attached to the external surface of each specimen and, during application of combined axial and torsional loads to the femoral head, the strains in both groups were measured. After the insertion of a non-cemented femoral component, the normal pattern of a progressive proximal-to-distal increase in strains was similar to that in the intact femur and the strain was maximum near the tip of the prosthesis. On the medial and lateral aspects of the proximal femur, the strains were greatly reduced after implantation of both types of implant. The pattern and magnitude of the strains, however, were closer to those in the intact femur after insertion of the experimental stem than in the reference stem. On the anterior and posterior aspects of the femur, implantation of both types of stem led to increased principal strains E1, E2 and E3. This was most pronounced for the experimental stem. Our findings suggest that the experimental stem, which has a more anatomical proximal fit without having a distal stem and cortex contact, can provide immediate postoperative stability. Pure proximal loading by the experimental stem in the metaphysis, reduction of excessive bending stiffness of the stem by tapering and the absence of contact between the stem and the distal cortex may reduce stress shielding, bone resorption and thigh pain


Aims

The aim of this study was to evaluate the outcomes of a salvage procedure using a 95° angled blade plate for failed osteosynthesis of atypical subtrochanteric femoral fractures associated with the long-term use of bisphosphonates. These were compared with those for failed osteosynthesis of subtrochanteric fractures not associated with bisphosphonate treatment.

Patients and Methods

Between October 2008 and July 2016, 14 patients with failed osteosynthesis of an atypical subtrochanteric femoral fracture were treated with a blade plate (atypical group). Their mean age was 67.8 years (60 to 74); all were female. During the same period, 21 patients with failed osteosynthesis of a typical subtrochanteric fracture underwent restabilization using a blade plate (typical group). Outcome variables included the time of union, postoperative complications, Harris Hip Score, and Sanders functional rating scale.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 822 - 827
1 Jun 2018
Pollet V Van Dijk L Reijman M Castelein RMC Sakkers RJB

Aims

Open reduction is required following failed conservative treatment of developmental dysplasia of the hip (DDH). The Ludloff medial approach is commonly used, but poor results have been reported, with rates of the development of avascular necrosis (AVN) varying between 8% and 54%. This retrospective cohort study evaluates the long-term radiographic and clinical outcome of dislocated hips treated using this approach.

Patients and Methods

Children with a dislocated hip, younger than one year of age at the time of surgery, who were treated using a medial approach were eligible for the study. Radiographs were evaluated for the degree of dislocation and the presence of an ossific nucleus preoperatively, and for the degree of AVN and residual dysplasia at one and five years and at a mean of 12.7 years (4.6 to 20.8) postoperatively. Radiographic outcome was assessed using the Severin classification, after five years of age. Further surgical procedures were recorded. Functional outcome was assessed using the Pediatric Outcomes Data Collection Instrument (PODCI) or the Hip Disability and Osteoarthritis Outcome Score (HOOS), depending on the patient’s age.


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 1 | Pages 64 - 81
1 Feb 1966
Stillman BC

Both osteochondritis dissecans and coxa plana are diseases with identical pathological changes, namely avascular necrosis. Although the etiology is not known in either case, it seems likely that when the etiological factors are fully determined they will prove to be applicable to either condition. The relative importance of each etiological factor in the multiple pathogenesis of these two conditions is almost certainly different in each disease process, and probably in each individual case. Present day concepts suggest that there is an underlying constitutional disturbance, which is associated with other factors (of which trauma is almost universally accepted as being one; perhaps the only one), to predispose the individual to these conditions. It is hoped that further studies along these lines will not only help to provide a better understanding of the two conditions mentioned above, but will also be of value in the appreciation of the pathogenesis and etiology of a large number of disturbances including such varied conditions as dysplasia epiphysialis multiplex congenita, cretinoid dysgenesis of the capital femoral epiphysis, adolescent coxa vara, transient synovitis of the hip, and the recently discussed (Merle d'Aubigné 1964) idiopathic avascular necrosis of the femoral head in adults. That there is an etiological relationship between osteochondritis dissecans and coxa plana seems clear, but much more work is required before we will have at hand the patho-physiological evidence that will permit an accurate correlation of these two conditions


The Journal of Bone & Joint Surgery British Volume
Vol. 43-B, Issue 3 | Pages 576 - 589
1 Aug 1961
Garden RS

Many analyses of the geometric arrangement of trabeculae in the proximal end of the femur have accepted and perpetuated the theories of Ward (1838), Culmann (1866) and Meyer (1867), and have contributed to the belief that the structure of the femoral neck embodies mechanical principles which are foreign to bony formations elsewhere. This isolated departure from the normal pattern of skeletal behaviour is considered to be most unlikely, and an attempt has been made to show that the structure of the femoral head and neck departs but little from the normal anatomy of the long bone. From a developmental point of view, the proximal end of the human femur is believed, in its simplest interpretation, to represent an upward continuation of the original shaft which has undergone rotation and expansion. The cancellous arrangements of the internal weight-bearing system are likewise believed to represent the expanded and rotated lamellae of the neck as they are presented radiologically or on coronal section. The forces acting upon the proximal end of the femur are considered to be mainly compressive in nature, and both crane and street-lamp bracket theories have therefore been rejected. The spiral conformity of the proximal end of the femur has been related to the spiral disposition of the soft-tissue structures that surround the hip, and in the interpretation of hip joint mechanics the principle of the screw has been preferred to the principle ofthe lever


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 6 - 13
1 Jan 1993
Kim Y Kim V

We studied 108 patients (116 hips) who were followed for a minimum of six years (73 to 89 months) after primary total hip arthroplasty using an uncemented porous-coated anatomic hip. The average age of the patients at operation was 48.4 years, and the diagnosis was avascular necrosis of the femoral head in 46 hips, neglected femoral neck fracture in 27, osteoarthritis secondary to childhood pyogenic arthritis in 24 and to childhood tuberculous arthritis in five, and miscellaneous in 14. The average preoperative Harris hip score was 55, which improved to 91 at latest follow-up. All patients with loose femoral components or disabling thigh pain had received prostheses which were undersized in the coronal or the sagittal plane, or in both. No patient with a satisfactory fit in both coronal and sagittal planes had loosening of the femoral component or disabling thigh pain. Three acetabular components showed aseptic loosening and 20 showed excessive wear (5 to 11 mm) of the polyethylene liner. Excessive wear was related to young age, but not to body-weight, gender, primary diagnosis, hip score, or range of hip movement. There was a high incidence of osteolysis (38 of 116 hips, 33%). We recommend careful preoperative planning, with the use of a contemporary cemented technique when a satisfactory fit cannot be obtained. The high incidence of excessive wear and of osteolysis needs further investigation


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 725 - 732
1 Jun 2018
Gibon E Barut N Courpied J Hamadouche M

Aims

The purpose of this retrospective study was to evaluate the minimum five-year outcome of revision total hip arthroplasty (THA) using the Kerboull acetabular reinforcement device (KARD) in patients with Paprosky type III acetabular defects and destruction of the inferior margin of the acetabulum.

Patients and Methods

We identified 36 patients (37 hips) who underwent revision THA under these circumstances using the KARD, fresh frozen allograft femoral heads, and reconstruction of the inferior margin of the acetabulum. The Merle d’Aubigné system was used for clinical assessment. Serial anteroposterior pelvic radiographs were used to assess migration of the acetabular component.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 973 - 978
1 Nov 1996
Malkani AL Voor MJ Fee KA Bates CS

We have tested the axial and torsional stability of femoral components after revision arthroplasty in a cadaver model, using impacted morsellised cancellous graft and cement. Each one of six matched pairs of fresh frozen human femora had either a primary or a revision prosthesis cemented in place. For the ‘revision’ experiments, all cancellous bone was removed from the proximal femur which was then over-reamed to create a smooth-walled cortical shell. An MTS servohydraulic test frame was used to apply axial and torsional loads to each specimen through the prosthetic femoral heads with the femur submerged in isotonic saline solution at 37°C. The mean subsidence was 0.27 ± 0.17 mm for the primary and 0.52 ± 0.30 mm for the revision groups. The difference was statistically significant (p < 0.025), but the mean subsidence was < 1 mm in both groups. The mean maximum torque before failure was 42.9 ± 26.9 N-m for the primary and 34.8± 20.7 N-m for the revision groups. This difference was not statistically significant (p > 0.015). Based on our results we suggest that revision of the femoral component using morsellised cancellous graft followed by cementing with a collarless prosthesis with a polished tapered stem restores the integrity of the proximal femur and provides immediate stability of the implant


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1275 - 1279
1 Oct 2018
Fader RR Tao MA Gaudiani MA Turk R Nwachukwu BU Esposito CI Ranawat AS

Aims

The purpose of this study was to evaluate spinopelvic mechanics from standing and sitting positions in subjects with and without femoroacetabular impingement (FAI). We hypothesize that FAI patients will experience less flexion at the lumbar spine and more flexion at the hip whilst changing from standing to sitting positions than subjects without FAI. This increase in hip flexion may contribute to symptomatology in FAI.

Patients and Methods

Male subjects were prospectively enrolled to the study (n = 20). Mean age was 31 years old (22 to 41). All underwent clinical examination, plain radiographs, and dynamic imaging using EOS. Subjects were categorized into three groups: non-FAI (no radiographic or clinical FAI or pain), asymptomatic FAI (radiographic and clinical FAI but no pain), and symptomatic FAI (patients with both pain and radiographic FAI). FAI was defined as internal rotation less than 15° and alpha angle greater than 60°. Subjects underwent standing and sitting radiographs in order to measure spine and femoroacetabular flexion.


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1577 - 1583
1 Dec 2017
Nakano N Lisenda L Jones TL Loveday DT Khanduja V

Aims

The number of patients undergoing arthroscopic surgery of the hip has increased significantly during the past decade. It has now become an established technique for the treatment of many intra- and extra-articular conditions affecting the hip. However, it has a steep learning curve and is not without the risk of complications. The purpose of this systematic review was to determine the prevalence of complications during and following this procedure.

Materials and Methods

Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were used in designing this study. Two reviewers systematically searched the literature for complications related to arthroscopy of the hip. The research question and eligibility criteria were established a priori. Pertinent data were abstracted and analysed.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 83 - 87
1 Jan 1992
Kim Y Kim V

We reviewed 82 primary arthroplasties (in 71 patients) in which cementless porous-coated hip prostheses were used. The mean age of the patients at operation was 52 years (24 to 86); they were followed up for an average of 62.1 months (60 to 66). The diagnosis was avascular necrosis of the femoral head in 35%, fracture of the femoral neck in 24%, primary osteoarthritis in 16% and miscellaneous in 25%. The average preoperative Harris hip score was 56.7 points and the average postoperative score was 83.3 points. Eight hips (10%) had component loosening; four had been revised and four were awaiting revision. In 27 hips (33%) there was a radiolucent line wider than 2 mm in zones 1 and 7. In 55 hips (67%) there was calcar resorption of more than 10 mm. Twenty patients (28%) complained of thigh pain although they had no radiographic evidence of loosening of a component. Factors that may have contributed to the poor clinical and radiographic results were: 1) inadequate surface area for bone ingrowth, particularly on the lateral aspect of the upper part of the prosthesis, 2) poor initial fit of the stem in the metaphysis, which resulted in cantilever motion of the proximal part of the stem about the well-fixed distal stem, and 3) the collar of the prosthesis, which prevented it from subsiding to a naturally stable position and caused damage to the calcar


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1455 - 1462
1 Nov 2018
Munro JT Millar JS Fernandez JW Walker CG Howie DW Shim VB

Aims

Osteolysis, secondary to local and systemic physiological effects, is a major challenge in total hip arthroplasty (THA). While osteolytic defects are commonly observed in long-term follow-up, how such lesions alter the distribution of stress is unclear. The aim of this study was to quantitatively describe the biomechanical implication of such lesions by performing subject-specific finite-element (FE) analysis on patients with osteolysis after THA.

Patients and Methods

A total of 22 hemipelvis FE models were constructed in order to assess the transfer of load in 11 patients with osteolysis around the acetabular component of a THA during slow walking and a fall onto the side. There were nine men and two women. Their mean age was 69 years (55 to 81) at final follow-up. Changes in peak stress values and loads to fracture in the presence of the osteolytic defects were measured.


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 2 | Pages 189 - 194
1 Mar 1983
Kent G Dodds R Klenerman L Watts R Bitensky L Chayen J

The aim of this study was to try to elucidate the increased susceptibility of the neck of femur to fracture. Quantitative polarised light microscopy has been applied to fresh, undecalcified sections of samples of bone taken from the site of fracture, in specimens taken at operation from patients with fractures of the femoral neck or osteoarthritic femoral heads or from the equivalent site from otherwise normal subjects at necropsy. In all 21 specimens of fractured necks of femur, but in none of the other specimens, relatively large crystals (up to 2.5 X 0.5 micrometres) were found close to the site of fracture; the properties of these crystals were compatible with their being apatite. Measurement of the natural birefringence of the collagen showed no difference in the orientation of the collagen in all three types of specimen. However, the orientation of acidic glycosaminoglycans, measured by the birefringence of alcian blue bound to these moieties, was 45 per cent lower in the specimens from fractured necks of femur than in the other specimens, even though the total content of acidic glycosaminoglycans was unchanged. Although the decreased orientation was most marked close to the site of fracture, it was still apparent 15 millimetres from that site. These changes were unlikely to be simply the sequelae of fracture since they were not found in traumatic fractures of other bones. Thus it is conceivable that changes in the orientation of the ground substance allow formation of relatively large crystals of apatite and that such crystals, in the microcrystalline mass of apatite, are the cause of the increased fragility of such bones


The Journal of Bone & Joint Surgery British Volume
Vol. 41-B, Issue 3 | Pages 550 - 557
1 Aug 1959
Denham RA

1. The hip joint usually acts as the fulcrum of a lever system. 2. The centre of gravity of supported parts, which is usually medial to the hip joint, exerts a rotational effect upon the pelvis. If pelvic position is to be maintained this force must be counterbalanced by hip muscles. 3. The force transmitted by the hip joint is the sum of the supported body weight and the tension in the balancing muscles. This force often exceeds the total weight of the body. 4. In some circumstances the loss of one pound of body weight relieves the hip joint of three pounds pressure. 5. A long femoral neck is an advantage to hip function, but in arthroplasty this must not lead to mechanical failure such as breaking or loosening of the prosthesis, or fracture of the bone. 6. Medial displacement of the femoral head upon the pelvis may cause a great decrease in joint pressure, but medial displacement alone of the shaft upon the head and neck does not influence the mechanics of the joint. 7. The position of the centre of gravity of supported parts is easily altered by slight variations in spinal position. Great changes in hip joint pressure are caused by small coronal spinal movements, but the advantage to man of being able to walk with the eyes steady outweighs the mechanical disadvantage to which his hip is subjected. 8. A femoral abduction osteotomy improves the mechanics of a hip joint deformed in adduction. 9. A walking stick or a crutch is most helpful in relieving joint pressure and reducing the work done by hip muscles