This single-blinded randomised controlled trial
investigated whether one design of mobile-bearing (MB) total knee replacement
(TKR) has any advantage over a fixed-bearing (FB) design on long-term
fixation as measured by radiostereometry. The amount of wear underneath
the mobile bearing was also evaluated. A series of 42 knees was randomised
to MB or FB tibial components with appropriate polyethylene inserts
and followed for between ten and 12 years, or until the death of
the patient. The polyethylene in the MB group was superior in that
it was gamma-irradiated in inert gas and was calcium-stearate free;
the polyethylene in the FB group was gamma-irradiated in air and
contained calcium stearate. In theory this should be advantageous
to the wear rate of the MB group. At final
We report the long-term clinical
A retrospective review of medial compartment arthroplasty in 22 patients (22 knees) is reported. The operations were performed between 1973 and 1978. Eighty-six per cent were rated good or excellent using the knee rating system devised by the Hospital for Special Surgery, New York. Excellent or good results were achieved in six patients who had previously had a high tibial osteotomy. At the time of
Transposition of part of the pes anserinus was used to treat 96 knees in 78 patients with recurrent, habitual or permanent dislocations of the patella. The knees with habitual (48) and permanent (27) dislocations also had extensive release of superolateral contracture. The patients were reviewed at an average
Correct positioning and alignment of components during primary total knee replacement (TKR) is widely accepted to be an important predictor of patient satisfaction and implant durability. This retrospective study reports the effect of the post-operative mechanical axis of the lower limb in the coronal plane on implant survival following primary TKR. A total of 501 TKRs in 396 patients were divided into an aligned group with a neutral mechanical axis (± 3°) and a malaligned group where the mechanical axis deviated from neutral by >
3°. At 15 years’
Of 37 consecutive patients suffering from tuberculosis of the lumbosacral spine, 26 were reviewed after an average
Most published randomised controlled trials which
compare the rates of wear of conventional and cross-linked (XL) polyethylene
(PE) in total hip arthroplasty (THA) have described their use with
a cementless acetabular component. . We conducted a prospective randomised study to assess the rates
of penetration of two distinct types of PE in otherwise identical
cemented all-PE acetabular components. . A total of 100 consecutive patients for THA were randomised to
receive an acetabular component which had been either highly XL
then remelted or moderately XL then annealed. . After a minimum of eight years
We reviewed 50 capitellocondylar elbow replacements performed by the lateral approach in 42 rheumatoid patients, at a median
From 1983 to 1985 we performed 114 primary hip replacements in 108 consecutive osteoarthritic patients using a non-cemented RM isoelastic femoral stem. After a mean
We report 12 patients with infiltrating muscular lipomas of the lower limbs all treated by wide resection. During
In a prospective study, we evaluated the clinical results of 23 patients with a cryopreserved non-tissue-antigen-matched meniscal transplant at a
We have studied 29 patients for at least five years after canal-expansive laminoplasty for cervical spondylotic myelopathy. The short- and long-term clinical results were compared, and successive radiographs assessed. The long-term clinical outcome was excellent in five patients, good in 12, fair in 11 and poor in one. The mean short- and long-term improvements were 54.4% and 48.5% but patients with focal kyphotic, kyphotic and S-shaped cervical spines did less well, as did those who had a decrease in the index of curvature of the cervical spine of more than 10 at
Stress shielding resulting in diminished bone
density following total knee replacement (TKR) may increase the
risk of migration and loosening of the prosthesis. This retrospective
study was designed to quantify the effects of the method of fixation
on peri-prosthetic tibial bone density beneath cemented and uncemented
tibial components of similar design and with similar long-term survival
rates. Standard radiographs taken between two months and 15 years
post-operatively were digitised from a matched group of TKRs using
cemented (n = 67) and uncemented (n = 67) AGC tibial prostheses.
Digital radiograph densitometry was used to quantify changes in
bone density over time. Age, length of
We have reviewed the results of 106 intertrochanteric osteotomies performed for osteonecrosis of the femoral head. The average age at operation was 47.5 years. At two years from operation 71% of the hips had a clinically satisfactory result and at final
This study compared the outcome of total knee
replacement (TKR) in adult patients with fixed- and mobile-bearing prostheses
during the first post-operative year and at five years’
We have reviewed 103 of 126 Chiari osteotomies carried out in our department between 1956 and 1987. The cases were graded radiologically, using the Japanese Orthopaedic Association (JOA) system, into a pre/early osteoarthritis (OA) group and an advanced OA group. In the pre/early group there were 86 hips. The mean
We performed a prospective study in 186 patients with a minimum
Fifty-two children with 62 discoid lateral menisci were reviewed at an average
We reviewed 236 of the 388 Chiari pelvic osteotomies performed between 1953 and 1967 at the Orthopaedic University Clinic of Vienna for the treatment of congenital dislocation and subluxation of the hip. Over 90% of the operations were performed by Chiari himself. Twenty-one hips had needed reoperation after an average of 15.4 years; the other 215 hips had been followed up for 20 to 34 years (mean 24.8). The overall clinical results were excellent or good in 51.4%, fair in 29.8% and poor in 18.3%. The results were worse with increasing age at operation. The Trendelenburg sign improved only in patients aged seven or less at operation, and range of movement decreased in all cases. Subjectively poor results were seen in patients with pre-operative signs of osteoarthritis. Radiological loss of correction during
We investigated the factors related to the radiological outcome of a transtrochanteric curved varus osteotomy in patients with osteonecrosis of the hip. We reviewed 73 hips in 62 patients with a mean