Advertisement for orthosearch.org.uk
Results 101 - 120 of 5901
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 4 | Pages 628 - 638
1 Nov 1971
Macnab I Dall D

1. Intertransverse fusion in the lumbar spine appears to have many advantages over previously described techniques. 2. The disadvantage of profuse bleeding can be overcome by the use of a Hastings frame and by an operative technique designed to demonstrate constant muscular and articular branches of the lumbar arteries. 3. Coagulation of these vessels by cautery and avoidance of dissection anterior to the plane of the transverse processes ensure that the operative procedure can be carried out with a blood loss averaging less than 500 millilitres


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 724 - 730
1 Jun 2008
Hartofilakidis G Georgiades G Babis GC Yiannakopoulos CK

We have evaluated the results of total hip replacement in patients with congenital hip disease using 46 cemented all-polyethylene Charnley acetabular components implanted with the cotyloplasty technique in 34 patients (group A), and compared them with 47 metal-backed cementless acetabular components implanted without bone grafting in 33 patients (group B). Patients in group A were treated between 1988 and 1993 and those in group B between 1990 and 1995. The mean follow-up for group A was 16.6 years (12 to 18) and the mean follow-up for group B was 13.4 years (10 to 16). Revision for aseptic loosening was undertaken in 15 hips (32.6%) in group A and in four hips (8.5%) in group B. When liner exchange was included, a total of 13 hips were revised in group B (27.7%). The mean polyethylene wear was 0.11 mm/yr (0.002 to 0.43) and 0.107 mm/yr (0 to 0.62) for groups A and B, respectively. Polyethylene wear in group A was associated with linear osteolysis, and in group B with expansile osteolysis. In patients with congenital hip disease, when 80% cover of the implant can be obtained, a cementless acetabular component appears to be acceptable and provides durable fixation. However, because of the type of osteolysis arising with these devices, early exchange of a worn liner is recommended before extensive bone loss makes revision surgery more complicated


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 60 - 63
1 Jan 1995
Kakiuchi M

A combined open and percutaneous operative technique has been devised for repair of tendo Achillis. This minimises postoperative scarring. We compared the long-term results of 12 patients treated by this method with the results of 10 who had undergone an open repair. The combined open and percutaneous repair gave significantly better relief of symptoms during everyday activities (p < 0.05), better single-limb hopping (p < 0.02) and a greater chance of returning to sport (p < 0.01). There were no significant differences between the two treatments as regards to active range of ankle motion, calf circumference or the ability to stand on tiptoe. The new technique gave better cosmetic results


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 235 - 237
1 Mar 1990
Learmonth I

Varus osteotomy of the distal femur is recommended for osteoarthritis of the knee with significant valgus deformity, but the operation is difficult to plan and perform. A simple technique involving a jig referenced to the line of the tibia is described. This allows accurate overcorrection by a few degrees, with impaction and secure fixation at the osteotomy. It has been successful, with no complications, in 12 consecutive knees


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 1 | Pages 33 - 35
1 Jan 1985
Jones D Moseley C

Twenty-one patients with leg-length inequality underwent femoral lengthening using the Wagner technique. When reviewed, seven were found to have varying degrees of posterior subluxation of the knee. Critical assessment demonstrated that each of these was associated with a hypoplastic femur. It is postulated that posterior displacement of the tibia on the femur occurred as a result of the distal femoral and intraarticular bony deficiencies


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 778 - 782
1 Jun 2014
Tinney A Khot A Eizenberg N Wolfe R Graham HK

Lengthening of the conjoined tendon of the gastrocnemius aponeurosis and soleus fascia is frequently used in the treatment of equinus deformities in children and adults. The Vulpius procedure as described in most orthopaedic texts is a division of the conjoined tendon in the shape of an inverted V. However, transverse division was also described by Vulpius and Stoffel, and has been reported in some clinical studies.

We studied the anatomy and biomechanics of transverse division of the conjoined tendon in 12 human cadavers (24 legs). Transverse division of the conjoined tendon resulted in predictable, controlled lengthening of the gastrocsoleus muscle-tendon unit. The lengthening achieved was dependent both on the level of the cut in the conjoined tendon and division of the midline raphé. Division at a proximal level resulted in a mean lengthening of 15.2 mm (sd 2.0, (12 to 19), which increased to 17.1 mm (sd 1.8, (14 to 20) after division of the midline raphé. Division at a distal level resulted in a mean lengthening of 21.0 mm (sd 2.0, (18 to 25), which increased to 26.4 mm (sd 1.4, (24 to 29) after division of the raphé. These differences were significant (p < 0.001).

Cite this article: Bone Joint J 2014; 96-B:778–82.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 173 - 178
1 Feb 2012
Malizos KN Papasoulis E Dailiana ZH Papatheodorou LK Varitimidis SE

The introduction of a trabecular tantalum rod has been proposed for the management of early-stage osteonecrosis of the femoral head but serves as a single-point of support of the necrotic lesion. We describe a technique using two or three 4.2 mm (or later 4.7 mm) tantalum pegs for the prevention of collapse of the necrotic lesion. We prospectively studied 21 patients (26 hips) with non-traumatic osteonecrosis of the femoral head treated in this manner. Of these, 21 patients (24 hips) were available for radiological and clinical evaluation at a mean follow-up of 46 months (18 to 67). Radiological assessment showed that only eight hips deteriorated according to the Association Research Circulation Osseous classification, and four hips according to the Classification of the Japanese Investigation Committee of Health and Welfare. Functional improvement was obtained with an improvement in the mean Harris hip score from 65.2 (33.67 to 95) to 88.1 (51.72 to 100), the mean Merle D’Aubigné-Postel score from 13 (6 to 18) to 16 (11 to 18), a mean visual analogue score for pain from 5.2 (0 to 9.5) to 2.6 (0 to 7), and the mean Short-Form 36 score from 80.4 (56.8 to 107.1) to 92.4 (67.5 to 115.7). Of these 24 hips followed for a minimum of 18 months, three were considered as failures at the final follow-up, having required total hip replacement. One of the hips without full follow-up was also considered to be a failure. In more than two-thirds of the surviving hips a satisfactory clinical outcome was achieved with promising radiological findings. The estimated mean implant survival was 60 months (95% confidence interval 53.7 to 66.3)


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 535 - 541
1 Apr 2008
Pendegrass CJ Sundar S Oddy MJ Cannon SR Briggs T Blunn GW

We used an in vivo model to assess the use of an autogenous cancellous bone block and marrow graft for augmenting tendon reattachment to metallic implants. We hypothesised that augmentation of the tendon-implant interface with a bone block would enable retention of the graft on the implant surface, enhance biological integration, and result in more consistent functional outcomes compared with previously reported morcellised graft augmentation techniques. A significant improvement in functional weight-bearing was observed between six and 12 weeks. The significant increase in ground reaction force through the operated limb between six and 12 weeks was greater than that reported previously with morcellised graft augmented reconstructions. Histological appearance and collagen fibre orientation with bone block augmentation more closely resembled that of an intact enthesis compared with the morcellised grafting technique. Bone block augmentation of tendon-implant interfaces results in more reliable functional and histological outcomes, with a return to pre-operative levels of weight-bearing by 24 weeks


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 444 - 448
1 May 1999
Magyar G Ahl TL Vibe P Toksvig-Larsen S Lindstrand A

We describe the results of 50 operations carried out on 46 patients with medial osteoarthritis of the knee of Ahlbäck grade 1 to 3. Patients were randomised either to a closed-wedge high tibial osteotomy (HTO) or an open-wedge procedure based on the hemicallotasis technique (HCO). Their median age was 55 years (38 to 68). The preoperative median hip-knee-ankle (HKA) angle was 171° (164 to 176) in the HTO group and 173° (165 to 179) in the HCO group. After six weeks, the median HKA angle was 185° (176 to 194) in the HTO group and 184° (181 to 188) in the HCO group. In the HTO group, seven patients were within the range of 182° to 186° compared with 21 in the HCO group (p < 0.001). One year later, ten HTO patients were within this range while the HKA angulation in the HCO group was unchanged. At two years the numbers were 11 and 18, respectively. We evaluated the clinical results on the Hospital for Special Surgery, Lysholm and Wallgren-Tegner activity scores, and patients completed part of the Nottingham Health Profile questionnaire. An impartial observer at the two-year follow-up concluded that all scores had improved, but found no clinical differences between the groups


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 69 - 73
1 Jan 1988
Aldegheri R Trivella G Renzi-Brivio L Tessari G Agostini S Lavini F

We report our experience of lengthening by over 30% a total of 117 lower limbs in achondroplastic patients. We have compared four methods: transverse osteotomy, oblique osteotomy, callotasis of the shaft and chondrodiatasis of the epiphysis. Chrondrodiatasis of the femur and callotasis of the tibia are the techniques which gave fewest complications


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 1 | Pages 23 - 29
1 Jan 1994
Ingman A Waters D

We report our experience with a modified implant and a new technique for locked intramedullary nailing of the humerus in 41 patients. Locking was by cross-screws placed from lateral to medial in the proximal humerus, and anteroposteriorly in the distal humerus. Early in the series, 11 nails were inserted at the shoulder, but we found that rehabilitation was faster after retrograde nailing through the olecranon fossa, which was used for the other 30. We used a closed technique for 29 of the nailings. Of the 41 patients treated, 21 had acute fractures, five had nonunion, and 15 had pathological fractures. Secure fixation was obtained for comminuted and osteoporotic fractures in any part of the humeral shaft, which allowed the early use of crutches and walking frames. Two nails were locked at only one end, and one of these became the only failure of union after an acute fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 781 - 785
1 Jun 2005
Temmerman OPP Raijmakers PGHM Berkhof J Hoekstra OS Teule GJJ Heyligers IC

In this meta-analysis we included 32 English-language articles published between January 1975 and June 2004 on the diagnostic performance of plain radiography, subtraction arthrography, nuclear arthrography and bone scintigraphy in detecting aseptic loosening of the femoral component, using criteria based on the Cochrane systematic review of screening and diagnostic tests. The mean sensitivity and specificity were, respectively, 82% (95% confidence interval (CI) 76 to 87) and 81% (95% CI 73 to 87) for plain radiography and 85% (95% CI 75 to 91) and 83% (95% CI 75 to 89) for nuclear arthrography. Pooled sensitivity and specificity were, respectively, 86% (95% CI 74 to 93) and 85% (95% CI 77 to 91) for subtraction arthrography and 85% (95% CI 79 to 89) and 72% (95% CI 64 to 79) for bone scintigraphy. Although the diagnostic performance of the imaging techniques was not significantly different, plain radiography and bone scintigraphy are preferred for the assessment of a femoral component because of their efficacy and lower risk of patient morbidity


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 667 - 670
1 Aug 1989
Laupattarakasem W Mahaisavariya B Kowsuwon W Saengnipanthkul S

Several methods for the correction of cubitus varus have been described, but most reported series are small and show a high rate of complications. We report a six-year personal experience of 77 osteotomies by a new technique which provides rigid fixation and allows correction of both varus and rotation deformities. It also prevents lateral bulging at the level of the osteotomy. In 58 cases followed up for an average of 16 months, there were no serious complications, a satisfactory carrying angle and no significant loss of movement, giving 88% excellent or good results


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 2 | Pages 228 - 232
1 Apr 1982
Pearcy M Burrough S

Assessment of bony union after anterior fusion of the lumbar spine has previously relied on the skilled interpretation of plain radiograph. A biplanar radiographic technique was used to measure small movements between vertebrae and to give a quantitative measure of bony union in 11 patients who had undergone interbody fusion with autogenous bone chips at one level in the lumbar spine. The investigation gave three types of results: bony union, where the fused level showed marked restriction of movement relative to the rest of the lumbar spine; paradoxical movement, where the fused joint showed marked reverse movement (when the patient flexed, the fused level of the lumbar spine extended) which was thought to be due to an anterior bony bar which caused an altered pattern of movement; and non-union, where the level of fusion showed no restriction of movement. The intervertebral joint above the level of fusion was shown to move more than the other joints in the lumbar spine. The study showed that bony union is possible with the use of autogenous cancellous bone chips, and that biplanar radiographic technique can determine the extent of union


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 752 - 755
1 Nov 1987
Harley J Wilkinson J

Total hip replacement for adults with unreduced congenital dislocation presents a difficult problem because soft-tissue contractures usually prevent sitting at the normal anatomical level. Extensive soft-tissue division or a high-level acetabulum leads to reduced function and poor fixation of the components. We describe a new technique for hip replacement in such cases. The shortened abductors and flexors are released proximally and excision of the upper third of the ilium allows them to be repaired without tension, while providing bone graft to reconstruct the acetabular roof. We report 12 such replacements in 10 patients with good results and few early complications


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 375 - 380
1 May 1993
McNally M Small J Tofighi H Mollan R

We treated 37 patients with chronic osteomyelitis of the tibia (25), femur (9), radius (2) and humerus (1) by a two-stage technique, comprising radical debridement of all infected bone and soft tissue with the provision of soft-tissue cover, and delayed autogenous bone grafting when necessary. All patients were reviewed at an average of 49 months (12 to 121). Infection-free bone union was achieved in 34. No patient required amputation. Wide excision of all compromised tissue and the closure of bone within a healthy vascularised soft-tissue envelope are essential if infection is to be eradicated. The combined assessment and management of such patients by an orthopaedic surgeon and a plastic surgeon are advocated


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1020 - 1026
1 Aug 2016
Śmigielski R Zdanowicz U Drwięga M Ciszek B Williams A

Anterior cruciate ligament (ACL) reconstruction is commonly performed and has been for many years. Despite this, the technical details related to ACL anatomy, such as tunnel placement, are still a topic for debate. In this paper, we introduce the flat ribbon concept of the anatomy of the ACL, and its relevance to clinical practice.

Cite this article: Bone Joint J 2016;98-B:1020–6.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 472 - 475
1 May 1988
Graham H Fixsen J

For equinus deformity in spastic hemiplegia, correction by the White slide technique has been studied in a group of 35 patients followed up for 14 to 20 years. It is a simple, effective method of lengthening the calcaneal tendon, and is free from significant complications with an acceptable rate of recurrent deformity. The majority of patients achieved a heel-toe gait


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1165 - 1171
1 Sep 2007
Gohil S Annear PO Breidahl W

Animal studies have shown that implanted anterior cruciate ligament (ACL) grafts initially undergo a process of revascularisation prior to remodelling, ultimately increasing mechanical strength. We investigated whether minimal debridement of the intercondylar notch and the residual stump of the ruptured ACL leads to earlier revascularisation in ACL reconstruction in humans. We undertook a randomised controlled clinical trial in which 49 patients underwent ACL reconstruction using autologous four-strand hamstring tendon grafts. Randomised by the use of sealed envelopes, 25 patients had a conventional clearance of the intercondylar notch and 24 had a minimal debridement method. Three patients were excluded from the study. All patients underwent MR scanning postoperatively at 2, 6 and 12 months, together with clinical assessment using a KT-1000 arthrometer and International Knee Documentation Committee (IKDC) evaluation. All observations were made by investigators blinded to the surgical technique. Signal intensity was measured in 4 mm diameter regions of interest along the ACL graft and the mid-substance of the posterior cruciate ligament. Our results indicate that minimal debridement leads to earlier revascularisation within the mid-substance of the ACL graft at two months (paired t-test, p = 0.002). There was a significant reduction of mid-substance signal six months after the minimal debridement technique (paired t-test, p = 0.00007). No statistically significant differences were found in tunnel placement, incidence of Cyclops lesions, blood loss, IKDC scores, range of movement or Lachman test between the two groups


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 643 - 646
1 Aug 1987
Kristiansen B Kofoed H

A new technique for the treatment of displaced fractures of the proximal humerus is described. Twelve fractures in 11 patients were managed by transcutaneous reduction using a Steinmann pin, and external fixation with a Hoffmann-type neutralising bar connected to two half-pins in the humeral head and three half-pins in the shaft. The pins were removed after four weeks. Two patients sustained redisplacement after a further injury, but in the others reduction was maintained. Two cases of pin-track infection resolved after antibiotics, but delayed union resulted. There were no neurovascular injuries and at follow-up of 6 to 12 months no refractures had been seen. The early functional results were excellent or satisfactory in nine cases