Advertisement for orthosearch.org.uk
Results 101 - 120 of 124
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 729 - 734
1 Jun 2012
Kakkos SK Warwick D Nicolaides AN Stansby GP Tsolakis IA

We performed a systematic review and meta-analysis to compare the efficacy of intermittent mechanical compression combined with pharmacological thromboprophylaxis, against either mechanical compression or pharmacological prophylaxis in preventing deep-vein thrombosis (DVT) and pulmonary embolism in patients undergoing hip or knee replacement. A total of six randomised controlled trials, evaluating a total of 1399 patients, were identified. In knee arthroplasty, the rate of DVT was reduced from 18.7% with anticoagulation alone to 3.7% with combined modalities (risk ratio (RR) 0.27, p = 0.03; number needed to treat: seven). There was moderate, albeit non-significant, heterogeneity (I2 = 42%). In hip replacement, there was a non-significant reduction in DVT from 8.7% with mechanical compression alone to 7.2% with additional pharmacological prophylaxis (RR 0.84) and a significant reduction in DVT from 9.7% with anticoagulation alone to 0.9% with additional mechanical compression (RR 0.17, p < 0.001; number needed to treat: 12), with no heterogeneity (I2 = 0%). The included studies had insufficient power to demonstrate an effect on pulmonary embolism.

We conclude that the addition of intermittent mechanical leg compression augments the efficacy of anticoagulation in preventing DVT in patients undergoing both knee and hip replacement. Further research on the role of combined modalities in thromboprophylaxis in joint replacement and in other high-risk situations, such as fracture of the hip, is warranted.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1180 - 1186
1 Sep 2012
Murray DW Grammatopoulos G Pandit H Gundle R Gill HS McLardy-Smith P

Recent events have highlighted the importance of implant design for survival and wear-related complications following metal-on-metal hip resurfacing arthroplasty. The mid-term survival of the most widely used implant, the Birmingham Hip Resurfacing (BHR), has been described by its designers. The aim of this study was to report the ten-year survival and patient-reported functional outcome of the BHR from an independent centre.

In this cohort of 554 patients (646 BHRs) with a mean age of 51.9 years (16.5 to 81.5) followed for a mean of eight years (1 to 12), the survival and patient-reported functional outcome depended on gender and the size of the implant. In female hips (n = 267) the ten-year survival was 74% (95% confidence interval (CI) 83 to 91), the ten-year revision rate for pseudotumour was 7%, the mean Oxford hip score (OHS) was 43 (sd 8) and the mean UCLA activity score was 6.4 (sd 2). In male hips (n = 379) the ten-year survival was 95% (95% CI 92.0 to 97.4), the ten-year revision rate for pseudotumour was 1.7%, the mean OHS was 45 (sd 6) and the mean UCLA score was 7.6 (sd 2). In the most demanding subgroup, comprising male patients aged < 50 years treated for primary osteoarthritis, the survival was 99% (95% CI 97 to 100).

This study supports the ongoing use of resurfacing in young active men, who are a subgroup of patients who tend to have problems with conventional THR. In contrast, the results in women have been poor and we do not recommend metal-on-metal resurfacing in women. Continuous follow-up is recommended because of the increasing incidence of pseudotumour with the passage of time.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1503 - 1507
1 Nov 2011
Maffulli N Del Buono A Testa V Capasso G Oliva F Denaro V

This is a prospective analysis on 30 physically active individuals with a mean age of 48.9 years (35 to 64) with chronic insertional tendinopathy of the tendo Achillis. Using a transverse incision, the tendon was debrided and an osteotomy of the posterosuperior corner of the calcaneus was performed in all patients. At a minimum post-operative follow-up of three years, the Victorian Institute of Sports Assessment scale – Achilles tendon scores were significantly improved compared to the baseline status. In two patients a superficial infection of the wound developed which resolved on antibiotics. There were no other wound complications, no nerve related complications, and no secondary avulsions of the tendo Achillis. In all, 26 patients had returned to their pre-injury level of activity and the remaining four modified their sporting activity. At the last appointment, the mean pain threshold and the mean post-operative tenderness were also significantly improved from the baseline (p < 0.001). In patients with insertional tendo Achillis a transverse incision allows a wide exposure and adequate debridement of the tendo Achillis insertion, less soft-tissue injury from aggressive retraction and a safe osteotomy of the posterosuperior corner of the calcaneum.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 284 - 285
1 Feb 2010
Lota AS Altaf F Shetty R Courtney S Mckenna P Iyer S

Necrotising fasciitis is a rare but severe infection of soft-tissue associated with rapid progression, systemic toxicity and high mortality. Monomicrobial necrotising fasciitis caused by Pseudomonas aeruginosa is exceptionally uncommon with only 12 cases reported in the literature. We describe a fatal case with an atypical presentation in a patient following spinal decompression for a metastasis from prostate cancer.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 562 - 569
1 May 2008
Daniel J Pradhan A Pradhan C Ziaee H Moss M Freeman J McMinn DJW

We report a retrospective review of the incidence of venous thromboembolism in 463 consecutive patients who underwent primary total hip arthroplasty (487 procedures). Treatment included both total hip replacement and hip resurfacing, and the patients were managed without anticoagulants. The thromboprophylaxis regimen included an antiplatelet agent, generally aspirin, hypotensive epidural anaesthesia, elastic compression stockings and early mobilisation. In 258 of these procedures (244 patients) performed in 2005 (cohort A) mechanical compression devices were not used, whereas in 229 (219 patients) performed during 2006 (cohort B) bilateral intermittent pneumatic calf compression was used.

All operations were performed through a posterior mini-incision approach. Patients who required anticoagulation for pre-existing medical problems and those undergoing revision arthroplasty were excluded. Doppler ultrasonographic screening for deep-vein thrombosis was performed in all patients between the fourth and sixth post-operative days. All patients were reviewed at a follow-up clinic six to ten weeks after the operation. In addition, reponse to a questionnaire was obtained at the end of 12 weeks post-operatively.

No symptomatic calf or above-knee deep-vein thrombosis or pulmonary embolism occurred. In 25 patients in cohort A (10.2%) and in ten patients in cohort B (4.6%) asymptomatic calf deep-vein thromboses were detected ultrasonographically. This difference was statistically significant (p = 0.03). The regimen followed by cohort B offers the prospect of a low incidence of venous thromboembolism without subjecting patients to the higher risk of bleeding associated with anticoagulant use.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 659 - 661
1 May 2009
Chettiar K Sriskandan N Thiagaraj S Desai AU Ross K Howlett DC

The use of ultrasound-guided wire localisation of lesions is not well described in the orthopaedic literature. We describe a case of an impalpable schwannoma of the femoral nerve and another of sacroiliitis with an associated pelvic abscess. In both, surgical localisation was difficult. Peri-operative ultrasound-guided wire localisation was used to guide surgery and minimise tissue damage, thereby optimising the results and recovery of the patient.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 536 - 539
1 Apr 2009
Edmundson SP Hirpara KM Ryan RS O’Malley T O’Grady P

We report a 30-year-old patient who was involved in a high-velocity road traffic accident and developed a left-sided hemiparesis, which was noted in the post-operative period following bilateral femoral intramedullary nailing. CT scanning of the brain revealed infarcts in the right frontal and parietal lobes in the distribution of the right middle cerebral artery. CT angiography showed occlusion of the right internal carotid artery consistent with internal carotid artery dissection. He was anticoagulated and nine months later was able to walk independently.

An awareness of this injury is needed to diagnose blunt trauma to the internal carotid artery. Even in the absence of obvious neck trauma, carotid artery dissection should be suspected in patients with a neurological deficit in the peri-operative period.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1289 - 1293
1 Sep 2010
Sultan J Hughes PJ

The crucial differentiation between septic arthritis and transient synovitis of the hip in children can be difficult. In 1999, Kocher et al introduced four clinical predictors which were highly predictive (99.6%) of septic arthritis. These included fever (temperature ≥ 38.5°C), inability to bear weight, white blood-cell count > 12.0 × 109 cells/L and ESR ≥ 40 mm/hr; CRP ≥ 20 mg/L was later added as a fifth predictor. We retrospectively evaluated these predictors to differentiate septic arthritis from transient synovitis of the hip in children over a four-year period in a primary referral general hospital. When all five were positive, the predicted probability of septic arthritis in this study was only 59.9%, with fever being the best predictor. When applied to low-prevalence diseases, even highly specific tests yield a high number of false positives and the predictive value is thereby diminished.

Clinical predictors should be applied with caution when assessing a child with an irritable hip, and a high index of suspicion, and close observation of patients at risk should be maintained.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1066 - 1071
1 Aug 2010
Chee YH Teoh KH Sabnis BM Ballantyne JA Brenkel IJ

We compared 55 consecutive total hip replacements performed on 53 morbidly obese patients with osteoarthritis with a matched group of 55 total hip replacements in 53 non-obese patients. The groups were matched for age, gender, prosthesis type, laterality and preoperative Harris Hip Score. They were followed prospectively for five years and the outcomes were assessed using the Harris Hip Score, the Short-form 36 score and radiological findings.

Survival at five years using revision surgery as an endpoint, was 90.9% (95% confidence interval 82.9 to 98.9) for the morbidly obese and 100% for the non-obese patients. The Harris Hip and the Short-form 36 scores were significantly better in the non-obese group (p < 0.001). The morbidly obese patients had a higher rate of complications (22% vs 5%, p = 0.012), which included dislocation and both superficial and deep infection.

In light of these inferior results, morbidly obese patients should be advised to lose weight before undergoing a total hip replacement, and counselled regarding the complications. Despite these poorer results, however, the patients have improved function and quality of life.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 572 - 579
1 May 2011
Haddad FS Thakrar RR Hart AJ Skinner JA Nargol AVF Nolan JF Gill HS Murray DW Blom AW Case CP

Lately, concerns have arisen following the use of large metal-on-metal bearings in hip replacements owing to reports of catastrophic soft-tissue reactions resulting in implant failure and associated complications. This review examines the literature and contemporary presentations on current clinical dilemmas in metal-on-metal hip replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 608 - 615
1 May 2011
Bolland BJRF Culliford DJ Langton DJ Millington JPS Arden NK Latham JM

This study reports the mid-term results of a large-bearing hybrid metal-on-metal total hip replacement in 199 hips (185 patients) with a mean follow-up of 62 months (32 to 83).

Two patients died of unrelated causes and 13 were lost to follow-up. In all, 17 hips (8.5%) have undergone revision, and a further 14 are awaiting surgery. All revisions were symptomatic. Of the revision cases, 14 hips showed evidence of adverse reactions to metal debris. The patients revised or awaiting revision had significantly higher whole blood cobalt ion levels (p = 0.001), but no significant difference in acetabular component size or position compared with the unrevised patients. Wear analysis (n = 5) showed increased wear at the trunnion-head interface, normal levels of wear at the articulating surfaces and evidence of corrosion on the surface of the stem.

The cumulative survival rate, with revision for any reason, was 92.4% (95% confidence interval 87.4 to 95.4) at five years. Including those awaiting surgery, the revision rate would be 15.1% with a cumulative survival at five years of 89.6% (95% confidence interval 83.9 to 93.4).

This hybrid metal-on-metal total hip replacement series has shown an unacceptably high rate of failure, with evidence of high wear at the trunnion-head interface and passive corrosion of the stem surface. This raises concerns about the use of large heads on conventional 12/14 tapers.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 814 - 816
1 Jun 2007
Nawabi DH Sinisi M

Schwannomas are the most common tumours of the sheath of peripheral nerves. The clinical diagnosis is usually straightforward, but may be delayed for many years in a schwannoma of the posterior tibial nerve. The symptoms are often attributed to entrapment neuropathy or to lumbosacral radiculopathy.

We describe 25 patients with a schwannoma of the posterior tibial nerve. Only three were diagnosed within a year of presentation. The mean time to diagnosis was 86.5 months with a median of 48 months (2 to 360). All the patients complained of pain, which was felt specifically in the sole of the foot in 18. A Tinel sign was detected in all 25 patients. MRI confirmed the diagnosis in all the cases in which it had been undertaken. Surgical resection of the lesion abolished the neuropathic pain. In patients with a long history of neuropathic pain in the lower limb in whom lumbar and pelvic lesions have been excluded, a benign tumour of the sheath of a peripheral nerve may explain the symptoms. Surgical resection of the tumour is safe and effective.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1275 - 1276
1 Sep 2005
Coupe NJ Patel SN McVerry S Wynn-Jones CH

We report a case of fatal haemorrhage following a low-energy fracture of the pubic ramus in an 85-year-old woman.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 166 - 168
1 Feb 2007
Chitre AR Fehily MJ Bamford DJ

Intra-articular injections of steroid into the hip are used for a variety of reasons in current orthopaedic practice. Recently their safety prior to ipsilateral total hip replacement has been called into question owing to concerns about deep joint infection.

We undertook a retrospective analysis of all patients who had undergone local anaesthetic and steroid injections followed by ipsilateral total hip replacement over a five-year period. Members of the surgical team, using a lateral approach to the hip, performed all the injections in the operating theatre using a strict aseptic technique. The mean time between injection and total hip replacement was 18 months (4 to 50). The mean follow-up after hip replacement was 25.8 months (9 to 78), during which time no case of deep joint sepsis was found.

In our series, ipsilateral local anaesthetic and steroid injections have not conferred an increased risk of infection in total hip replacement. We believe that the practice of intra-articular local anaesthetic and steroid injections to the hip followed by total hip replacement is safer than previously reported.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 827 - 832
1 Jul 2008
Rees JL

This review discusses the pathogenesis and surgical treatment of tears of the rotator cuff.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 83 - 91
1 Jan 2010
Moosmayer S Lund G Seljom U Svege I Hennig T Tariq R Smith H

In order to compare the outcome from surgical repair and physiotherapy, 103 patients with symptomatic small and medium-sized tears of the rotator cuff were randomly allocated to one of the two approaches. The primary outcome measure was the Constant score, and secondary outcome measures included the self-report section of the American Shoulder and Elbow Surgeons score, the Short Form 36 Health Survey and subscores for shoulder movement, pain, strength and patient satisfaction. Scores were taken at baseline and after six and 12 months by a blinded assessor. Nine patients (18%) with insufficient benefit from physiotherapy after at least 15 treatment sessions underwent secondary surgical treatment.

Analysis of between-group differences showed better results for the surgery group on the Constant scale (difference 13.0 points, p − 0.002), on the American Shoulder and Elbow surgeons scale (difference 16.1 points, p < 0.0005), for pain-free abduction (difference 28.8°, p = 0.003) and for reduction in pain (difference on a visual analogue scale −1.7 cm, p < 0.0005).


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 388 - 394
1 Mar 2009
Goel DP Buckley R deVries G Abelseth G Ni A Gray R

The incidence of deep-vein thrombosis and the need for thromboprophylaxis following isolated trauma below the knee is uncertain. We have investigated this with a prospective randomised double-blind controlled trial using low molecular weight heparin with saline injection as placebo in patients aged between 18 and 75 years who had sustained an isolated fracture below the knee which required operative fixation. All patients had surgery within 48 hours of injury and were randomised to receive either the placebo or low molecular weight heparin for 14 days, after which they underwent bilateral lower limb venography, interpreted by three independent radiologists. Further follow-up was undertaken at two, six, eight and 12 weeks.

A total of 238 patients fulfilled all the inclusion criteria, with 127 in the low molecular weight heparin group and 111 in the placebo group, all of whom underwent bilateral venography. There was no statistically significant difference in the incidence of deep-vein thrombosis between those patients treated with low molecular weight heparin or the placebo (p = 0.22). The number of deep-vein thromboses in the two groups was 11 (8.7%) and 14 (12.6%), respectively. Age and the type of fracture were significantly associated with the rate of deep-vein thrombosis (p = 0.001 and p = 0.009, respectively) but gender, comorbidities and the body mass index were not.

The overall incidence of deep-vein thrombosis in this series was 11%. There was no clinical or statistical significant reduction in the incidence of deep-vein thrombosis with the use of thromboprophylaxis. However, we accept that owing to a cessation of funding, recruitment to this trial had to be ended prior to establishing the necessary sample size. Our results cannot, therefore, categorically exclude the possibility that low molecular weight heparin treatment could be beneficial. We recommend a further multicentre trial be undertaken to resolve this matter.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 38 - 46
1 Jan 2010
Langton DJ Jameson SS Joyce TJ Hallab NJ Natu S Nargol AVF

Early failure associated with adverse reactions to metal debris is an emerging problem after hip resurfacing but the exact mechanism is unclear. We analysed our entire series of 660 metal-on-metal resurfacings (Articular Surface Replacement (ASR) and Birmingham Hip Resurfacing (BHR)) and large-bearing ASR total hip replacements, to establish associations with metal debris-related failures. Clinical and radiological outcomes, metal ion levels, explant studies and lymphocyte transformation tests were performed. A total of 17 patients (3.4%) were identified (all ASR bearings) with adverse reactions to metal debris, for which revision was required. This group had significantly smaller components, significantly higher acetabular component anteversion, and significantly higher whole concentrations of blood and joint chromium and cobalt ions than asymptomatic patients did (all p < 0.001). Post-revision lymphocyte transformation tests on this group showed no reactivity to chromium or cobalt ions. Explants from these revisions had greater surface wear than retrievals for uncomplicated fractures. The absence of adverse reactions to metal debris in patients with well-positioned implants usually implies high component wear.

Surgeons must consider implant design, expected component size and acetabular component positioning in order to reduce early failures when performing large-bearing metal-on-metal hip resurfacing and replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1224 - 1227
1 Sep 2006
Arumilli BRB Koneru P Garg NK Davies R Saville S Sampath J Bruce C

The practice of regular radiological follow-up of infants with a positive family history of developmental dysplasia of the hip is based on the widespread belief that primary acetabular dysplasia is a genetic disorder which can occur in the absence of frank subluxation or dislocation. We reviewed all infants who were involved in our screening programme for developmental dysplasia of the hip, between November 2002 and January 2004, and who had a normal clinical and ultrasound examination of the hip at six to eight weeks of age, but who, because of a family history of developmental dysplasia of the hip, had undergone further radiography after an interval of 6 to 12 months. The radiographs of 89 infants were analysed for signs of late dysplasia of the hip and assessed independently by three observers to allow for variability of measurement. There were 11 infants (11%) lost to follow-up.

All the patients had normal radiographs at the final follow-up and none required any intervention. We therefore question the need for routine radiological follow-up of infants with a positive family history of developmental dysplasia of the hip, but who are normal on clinical examination and assessment by ultrasound screening when six to eight weeks old.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1454 - 1458
1 Nov 2005
Govender S