Advertisement for orthosearch.org.uk
Results 1181 - 1200 of 1495
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1050 - 1055
1 Aug 2016
Karachalios T Varitimidis S Bargiotas K Hantes M Roidis N Malizos KN

Aims

The Advance Medial-Pivot total knee arthroplasty (TKA) was designed to reflect contemporary data regarding the kinematics of the knee. We wished to examine the long-term results obtained with this prosthesis by extending a previous evaluation.

Patients and Methods

We retrospectively evaluated prospectively collected data from 225 consecutive patients (41 men and 184 women; mean age at surgery 71 years, 52 to 84) who underwent 284 TKAs with a mean follow-up of 13.4 years (11 to 15). Implant failure, complication rate, clinical (both subjective and objective) and radiological outcome were assessed. Pre- and post-operative clinical and radiographic data were available at regular intervals for all patients. A total of ten patients (4.4%; ten TKAs) were lost to follow-up.


Bone & Joint 360
Vol. 5, Issue 3 | Pages 36 - 37
1 Jun 2016
Das A


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1608 - 1614
1 Dec 2015
Tice A Kim P Dinh† L Ryu JJ Beaulé PE

The primary purpose of this study of metal-on-metal (MoM) hip resurfacing was to compare the effect of using a cementless or cemented femoral component on the subsequent bone mineral density (BMD) of the femoral neck.

This was a single-centre, prospective, double-blinded control trial which randomised 120 patients (105 men and 15 women) with a mean age of 49.4 years (21 to 68) to receive either a cemented or cementless femoral component. Follow-up was to two years. Outcome measures included total and six-point region-of-interest BMD of the femoral neck, radiological measurements of acetabular inclination, neck-shaft and stem-shaft angles, and functional outcome scores including the Harris hip score, the Western Ontario and McMaster Universities Osteoarthritis Index and the University of California at Los Angeles activity scale.

In total, 17 patients were lost to follow-up leaving 103 patients at two years. There were no revisions in the cementless group and three revisions (5%) in the cemented group (two because of hip pain and one for pseudotumour).

The total BMD was significantly higher in the cementless group at six months (p < 0.001) and one year (p = 0.01) than in the cemented group, although there was a loss of statistical significance in the difference at two years (p = 0.155).

All patient outcomes improved significantly: there were no significant differences between the two groups.

The results show better preservation of femoral neck BMD with a cementless femoral component after two years of follow-up. Further investigation is needed to establish whether this translates into improved survivorship.

Cite this article: Bone Joint J 2015;97-B:1608–14.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1458 - 1462
1 Nov 2015
Langlois J Atlan F Scemama C Courpied JP Hamadouche M

Most published randomised controlled trials which compare the rates of wear of conventional and cross-linked (XL) polyethylene (PE) in total hip arthroplasty (THA) have described their use with a cementless acetabular component.

We conducted a prospective randomised study to assess the rates of penetration of two distinct types of PE in otherwise identical cemented all-PE acetabular components.

A total of 100 consecutive patients for THA were randomised to receive an acetabular component which had been either highly XL then remelted or moderately XL then annealed.

After a minimum of eight years follow-up, 38 hips in the XL group and 30 hips in the annealed group had complete data (mean follow-up of 9.1 years (7.6 to 10.7) and 8.7 years (7.2 to 10.2), respectively). In the XL group, the steady state rate of penetration from one year onwards was -0.0002 mm/year (sd 0.108): in the annealed group it was 0.1382 mm/year (sd 0.129) (Mann–Whitney U test, p < 0.001). No complication specific to either material was recorded.

These results show that the yearly linear rate of femoral head penetration can be significantly reduced by using a highly XLPE cemented acetabular component.

Cite this article: Bone Joint J 2015;97-B:1458–62.


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1299 - 1311
1 Oct 2016
Hong CC Pearce CJ Ballal MS Calder JDF

Injuries to the foot in athletes are often subtle and can lead to a substantial loss of function if not diagnosed and treated appropriately. For these injuries in general, even after a diagnosis is made, treatment options are controversial and become even more so in high level athletes where limiting the time away from training and competition is a significant consideration.

In this review, we cover some of the common and important sporting injuries affecting the foot including updates on their management and outcomes.

Cite this article: Bone Joint J 2016;98-B:1299–1311.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 164 - 172
1 Feb 2015
Grammatopoulos G Thomas GER Pandit H Beard DJ Gill HS Murray DW

We assessed the orientation of the acetabular component in 1070 primary total hip arthroplasties with hard-on-soft, small diameter bearings, aiming to determine the size and site of the target zone that optimises outcome. Outcome measures included complications, dislocations, revisions and ΔOHS (the difference between the Oxford Hip Scores pre-operatively and five years post-operatively). A wide scatter of orientation was observed (2sd 15°). Placing the component within Lewinnek’s zone was not associated withimproved outcome. Of the different zone sizes tested (± 5°, ± 10° and ± 15°), only ± 15° was associated with a decreased rate of dislocation. The dislocation rate with acetabular components inside an inclination/anteversion zone of 40°/15° ± 15° was four times lower than those outside. The only zone size associated with statistically significant and clinically important improvement in OHS was ± 5°. The best outcomes (ΔOHS > 26) were achieved with a 45°/25° ± 5° zone.

This study demonstrated that with traditional technology surgeons can only reliably achieve a target zone of ±15°. As the optimal zone to diminish the risk of dislocation is also ±15°, surgeons should be able to achieve this. This is the first study to demonstrate that optimal orientation of the acetabular component improves the functional outcome. However, the target zone is small (± 5°) and cannot, with current technology, be consistently achieved.

Cite this article: Bone Joint J 2015;97-B:164–72.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1463 - 1469
1 Nov 2015
Jonsson BA Kadar T Havelin LI Haugan K Espehaug B Indrekvam K Furnes O Hallan G

We report the five-year outcome of a randomised controlled trial which used radiostereometric analysis (RSA) to assess the influence of surface oxidised zirconium (OxZr, Oxinium) on polyethylene wear in vivo.

A total of 120 patients, 85 women and 35 men with a mean age of 70 years (59 to 80) who were scheduled for primary cemented total hip arthroplasty were randomly allocated to four study groups. Patients were blinded to their group assignment and received either a conventional polyethylene (CPE) or a highly cross-linked (HXL) acetabular component of identical design. On the femoral side patients received a 28 mm head made of either cobalt-chromium (CoCr) or OxZr.

The proximal head penetration (wear) was measured with repeated RSA examinations over five years. Clinical outcome was measured using the Harris hip score.

There was no difference in polyethylene wear between the two head materials when used with either of the two types of acetabular component (p = 0.3 to 0.6). When comparing the two types of polyethylene there was a significant difference in favour of HXLPE, regardless of the head material used (p < 0.001).

In conclusion, we found no advantage of OxZr over CoCr in terms of polyethylene wear after five years of follow-up. Our findings do not support laboratory results which have shown a reduced rate of wear with OxZr. They do however add to the evidence on the better resistance to wear of HXLPE over CPE.

Cite this article: Bone Joint J 2015;97-B:1463–9.


Bone & Joint 360
Vol. 5, Issue 3 | Pages 31 - 32
1 Jun 2016


Bone & Joint 360
Vol. 5, Issue 3 | Pages 24 - 25
1 Jun 2016


Bone & Joint 360
Vol. 3, Issue 5 | Pages 12 - 16
1 Oct 2014

The October 2014 Knee Roundup360 looks at: microfracture equivalent to OATS; examination better than MRI in predicting hamstrings re-injury; a second view on return to play with hamstrings injuries; dislocation risks in the Oxford Unicompartmental Knee; what about the tibia?; getting on top of lateral facet pain post TKR; readmission in TKR; patient-specific instrumentation; treating infrapatellar saphenous neuralgia; and arthroscopy in the middle-aged.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 623 - 627
1 May 2015
Lee AJJ Armour P Thind D Coates MH Kang ACL

Acetabular labral tears and associated intra-articular pathology of the hip have been recognised as a source of symptoms. However, it is now appreciated that there is a relatively high prevalence of asymptomatic labral tears. In this study, 70 young asymptomatic adult volunteers with a mean age of 26 years (19 to 41) were recruited and underwent three tesla non-arthrographic MR scans. There were 47 women (67.1%) and 23 men (32.9%).

Labral tears were found in 27 volunteers (38.6%); these were an isolated finding in 16 (22.9%) and were associated with other intra-articular pathology in the remaining 11 (15.7%) volunteers. Furthermore, five (7.1%) had intra-articular pathology without an associated labral tear.

Given the high prevalence of labral pathology in the asymptomatic population, it is important to confirm that a patient's symptoms are due to the demonstrated abnormalities when considering surgery.

Cite this article: Bone Joint J 2015;97-B:623–7.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1515 - 1519
1 Nov 2014
Allen D Sale G

Although patients with a history of venous thromboembolism (VTE) who undergo lower limb joint replacement are thought to be at high risk of further VTE, the actual rate of recurrence has not been reported.

The purpose of this study was to identify the recurrence rate of VTE in patients who had undergone lower limb joint replacement, and to compare it with that of patients who had undergone a joint replacement without a history of VTE.

From a pool of 6646 arthroplasty procedures (3344 TKR, 2907 THR, 243 revision THR, 152 revision TKR) in 5967 patients (68% female, mean age 67.7; 21 to 96) carried out between 2009 and 2011, we retrospectively identified 118 consecutive treatment episodes in 106 patients (65% female, mean age 70; 51 to 88,) who had suffered a previous VTE. Despite mechanical prophylaxis and anticoagulation with warfarin, we had four recurrences by three months (3.4% of 118) and six by one year (5.1% of 118). In comparison, in all our other joint replacements the rate of VTE was 0.54% (35/6528).

The relative risk of a VTE by 90 days in patients who had undergone a joint replacement with a history of VTE compared with those with a joint replacement and no history of VTE was 6.3 (95% confidence interval, 2.3 to 17.5). There were five complications in the previous VTE group related to bleeding or over-anticoagulation.

Cite this article: Bone Joint J 2014;96-B:1515–19.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1316 - 1321
1 Oct 2015
Fukui K Trindade CAC Briggs KK Philippon MJ

The purpose of this study was to determine patient-reported outcomes of patients with mild to moderate developmental dysplasia of the hip (DDH) and femoroacetabular impingement (FAI) undergoing arthroscopy of the hip in the treatment of chondrolabral pathology. A total of 28 patients with a centre-edge angle between 15° and 19° were identified from an institutional database. Their mean age was 34 years (18 to 53), with 12 female and 16 male patients. All underwent labral treatment and concomitant correction of FAI. There were nine reoperations, with two patients requiring revision arthroscopy, two requiring periacetabular osteotomy and five needing total hip arthroplasty.

Patients who required further major surgery were more likely to be older, male, and to have more severe DDH with a larger alpha angle and decreased joint space.

At a mean follow-up of 42 months (24 to 89), the mean modified Harris hip score improved from 59 (20 to 98) to 82 (45 to 100; p < 0.001). The mean Western Ontario and McMaster Universities Osteoarthritis Index score improved from 30 (1 to 61) to 16 (0 to 43; p < 0.001). Median patient satisfaction was 9.0/10 (1 to 10). Patients reported excellent improvement in function following arthroscopy of the hip.

This study shows that with proper patient selection, arthroscopy of the hip can be successful in the young patient with mild to moderate DDH and FAI.

Cite this article: Bone Joint J 2015;97-B:1316–21.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 595 - 602
1 May 2015
McCalden RW Korczak A Somerville L Yuan X Naudie DD

This was a randomised controlled trial studying the safety of a new short metaphyseal fixation (SMF) stem. We hypothesised that it would have similar early clinical results and micromovement to those of a standard-length tapered Synergy metaphyseal fixation stem. Using radiostereometric analysis (RSA) we compared the two stems in 43 patients. A short metaphyseal fixation stem was used in 22 patients and a Synergy stem in 21 patients. No difference was found in the clinical outcomes pre- or post-operatively between groups. RSA showed no significant differences two years post-operatively in mean micromovement between the two stems (except for varus/valgus tilt at p = 0.05) (subsidence 0.94 mm (sd 1.71) vs 0.32 mm (sd 0.45), p = 0.66; rotation 0.96° (sd 1.49) vs 1.41° (sd 2.95), p = 0.88; and total migration 1.09 mm (sd 1.74) vs 0.73 mm (sd 0.72), p = 0.51). A few stems (four SMF and three Synergy) had initial migration > 1.0 mm but stabilised by three to six months, with the exception of one SMF stem which required revision three years post-operatively. For most stems, total micromovement was very low at two years (subsidence < 0.5 mm, rotation < 1.0°, total migration < 0.5 mm), which was consistent with osseous ingrowth. The small sample makes it difficult to confirm the universal applicability of or elucidate the potential contraindications to the use of this particular new design of stem.

Cite this article: Bone Joint J 2015; 97-B:595–602.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1170 - 1174
1 Sep 2015
Patel A Pavlou G Ahmad RA Toms A

In England and Wales more than 175 000 hip and knee arthroplasties were performed in 2012. There continues to be a steady increase in the demand for joint arthroplasty because of population demographics and improving survivorship. Inevitably though the absolute number of periprosthetic infections will probably increase with severe consequences on healthcare provision. The Department of Health and the Health Protection Agency in United Kingdom established a Surgical Site Infection surveillance service (SSISS) in 1997 to undertake surveillance of surgical site infections. In 2004 mandatory reporting was introduced for one quarter of each year. There has been a wide variation in reporting rates with variable engagement with the process. The aim of this article is to improve surgeon awareness of the process and emphasise the importance of engaging with SSISS to improve the quality and type of data submitted. In Exeter we have been improving our practice by engaging with SSISS. Orthopaedic surgeons need to take ownership of the data that are submitted to ensure these are accurate and comprehensive.

Cite this article: Bone Joint J 2015;97-B:1170–4.


The early failure and revision of bimodular primary total hip arthroplasty prostheses requires the identification of the risk factors for material loss and wear at the taper junctions through taper wear analysis. Deviations in taper geometries between revised and pristine modular neck tapers were determined using high resolution tactile measurements. A new algorithm was developed and validated to allow the quantitative analysis of material loss, complementing the standard visual inspection currently used.

The algorithm was applied to a sample of 27 retrievals (in situ from 2.9 to 38.1 months) of the withdrawn Rejuvenate modular prosthesis. The mean wear volumes on the flat distal neck piece taper was 3.35 mm3 (0.55 to 7.57), mainly occurring in a characteristic pattern in areas with high mechanical loading. Wear volume tended to increase with time to revision (r² = 0.423, p = 0.001). Implant and patient specific data (offset, stem size, patient’s mass, age and body mass index) did not correlate with the amount of material loss observed (p >  0.078). Bilaterally revised implants showed higher amounts of combined total material loss and similar wear patterns on both sides. The consistent wear pattern found in this study has not been reported previously, suggesting that the device design and materials are associated with the failure of this prosthesis.

Cite this article: Bone Joint J 2015;97-B:1350–7.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 762 - 770
1 Jun 2015
Pennington MW Grieve R van der Meulen JH

There is little evidence on the cost effectiveness of different brands of hip prostheses. We compared lifetime cost effectiveness of frequently used brands within types of prosthesis including cemented (Exeter V40 Contemporary, Exeter V40 Duration and Exeter V40 Elite Plus Ogee), cementless (Corail Pinnacle, Accolade Trident, and Taperloc Exceed) and hybrid (Exeter V40 Trilogy, Exeter V40 Trident, and CPT Trilogy). We used data from three linked English national databases to estimate the lifetime risk of revision, quality-adjusted life years (QALYs) and cost.

For women with osteoarthritis aged 70 years, the Exeter V40 Elite Plus Ogee had the lowest risk of revision (5.9% revision risk, 9.0 QALYs) and the CPT Trilogy had the highest QALYs (10.9% revision risk, 9.3 QALYs). Compared with the Corail Pinnacle (9.3% revision risk, 9.22 QALYs), the most commonly used brand, and assuming a willingness-to-pay of £20 000 per QALY gain, the CPT Trilogy is most cost effective, with an incremental net monetary benefit of £876. Differences in cost effectiveness between the hybrid CPT Trilogy and Exeter V40 Trident and the cementless Corail Pinnacle and Taperloc Exceed were small, and a cautious interpretation is required, given the limitations of the available information.

However, it is unlikely that cemented brands are among the most cost effective. Similar patterns of results were observed for men and other ages. The gain in quality of life after total hip arthroplasty, rather than the risk of revision, was the main driver of cost effectiveness.

Cite this article: Bone Joint J 2015;97-B:762–70.


Bone & Joint 360
Vol. 5, Issue 2 | Pages 21 - 23
1 Apr 2016


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 208 - 214
1 Feb 2015
Chong A Nazarian N Chandrananth J Tacey M Shepherd D Tran P

This study sought to determine the medium-term patient-reported and radiographic outcomes in patients undergoing surgery for hallux valgus. A total of 118 patients (162 feet) underwent surgery for hallux valgus between January 2008 and June 2009. The Manchester-Oxford Foot Questionnaire (MOXFQ), a validated tool for the assessment of outcome after surgery for hallux valgus, was used and patient satisfaction was sought. The medical records and radiographs were reviewed retrospectively. At a mean of 5.2 years (4.7 to 6.0) post-operatively, the median combined MOXFQ score was 7.8 (IQR:0 to 32.8). The median domain scores for pain, walking/standing, and social interaction were 10 (IQR: 0 to 45), 0 (IQR: 0 to 32.1) and 6.3 (IQR: 0 to 25) respectively. A total of 119 procedures (73.9%, in 90 patients) were reported as satisfactory but only 53 feet (32.7%, in 43 patients) were completely asymptomatic. The mean (SD) correction of hallux valgus, intermetatarsal, and distal metatarsal articular angles was 18.5° (8.8°), 5.7° (3.3°), and 16.6° (8.8°), respectively. Multivariable regression analysis identified that an American Association of Anesthesiologists grade of > 1 (Incident Rate Ratio (IRR) = 1.67, p-value = 0.011) and recurrent deformity (IRR = 1.77, p-value = 0.003) were associated with significantly worse MOXFQ scores. No correlation was found between the severity of deformity, the type, or degree of surgical correction and the outcome. When using a validated outcome score for the assessment of outcome after surgery for hallux valgus, the long-term results are worse than expected when compared with the short- and mid-term outcomes, with 25.9% of patients dissatisfied at a mean follow-up of 5.2 years.

Cite this article: Bone Joint J 2015;97-B:208–14.


Bone & Joint 360
Vol. 5, Issue 2 | Pages 11 - 13
1 Apr 2016