Advertisement for orthosearch.org.uk
Results 121 - 140 of 390
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1206 - 1214
1 Jul 2021
Tsikandylakis G Mortensen KRL Gromov K Mohaddes M Malchau H Troelsen A

Aims

We aimed to investigate if the use of the largest possible cobalt-chromium head articulating with polyethylene acetabular inserts would increase the in vivo wear rate in total hip arthroplasty.

Methods

In a single-blinded randomized controlled trial, 96 patients (43 females), at a median age of 63 years (interquartile range (IQR) 57 to 69), were allocated to receive either the largest possible modular femoral head (36 mm to 44 mm) in the thinnest possible insert or a standard 32 mm head. All patients received a vitamin E-doped cross-linked polyethylene insert and a cobalt-chromium head. The primary outcome was proximal head penetration measured with radiostereometric analysis (RSA) at two years. Secondary outcomes were volumetric wear, periacetabular radiolucencies, and patient-reported outcomes.


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 25 - 32
1 Jul 2021
Amstutz HC Le Duff MJ

Aims

Adverse local tissue reactions associated with abnormal wear considerably slowed down the general use of metal-on-metal (MoM) hip resurfacing arthroplasty (HRA), now limited to a few specialized centres. In this study, we provide the clinical results of 400 consecutive MoM HRAs implanted more than 20 years ago in one such centre.

Methods

A total of 355 patients (400 hips) were treated with Conserve Plus HRA between November 1996 and November 2000. There were 96 female (27%) and 259 male patients (73%). Their mean age was 48.2 years (SD 10.9). The University of California, Los Angeles (UCLA) hip scores and 12-item Short Form Survey (SF-12) quality of life scores were reported. Survivorship was assessed using Kaplan-Meier analyses.


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 1 | Pages 36 - 49
1 Feb 1954
James JIP

The evolution of an idiopathic scoliosis is determined by the site of the primary curve and by the age of onset. It is significant that thoracic primary curves are commonly severe and the early onset of this curve accentuates this feature. Early operation based on prognosis is practised but sufficient time has not yet elapsed to justify any conclusions


Bone & Joint Research
Vol. 10, Issue 7 | Pages 411 - 424
14 Jul 2021
Zhao D Ren B Wang H Zhang X Yu M Cheng L Sang Y Cao S Thieringer FM Zhang D Wan Y Liu C

Aims

The use of 3D-printed titanium implant (DT) can effectively guide bone regeneration. DT triggers a continuous host immune reaction, including macrophage type 1 polarization, that resists osseointegration. Interleukin 4 (IL4) is a specific cytokine modulating osteogenic capability that switches macrophage polarization type 1 to type 2, and this switch favours bone regeneration.

Methods

IL4 at concentrations of 0, 30, and 100 ng/ml was used at day 3 to create a biomimetic environment for bone marrow mesenchymal stromal cell (BMMSC) osteogenesis and macrophage polarization on the DT. The osteogenic and immune responses of BMMSCs and macrophages were evaluated respectively.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 810 - 813
1 Sep 1994
Kenan S Lewis M Abdelwahab I Klein M

We present a case of subperiosteal giant-cell reparative granuloma followed over six years showing the complete evolution from the early phase of subperiosteal haematoma to the end stage of an ossified haematoma. Such lesions, although they are histologically similar to true giant-cell tumours, can be distinguished by the patients' age, their location on the diaphysis, and by their radiological and histological features


Bone & Joint Open
Vol. 2, Issue 6 | Pages 397 - 404
1 Jun 2021
Begum FA Kayani B Magan AA Chang JS Haddad FS

Limb alignment in total knee arthroplasty (TKA) influences periarticular soft-tissue tension, biomechanics through knee flexion, and implant survival. Despite this, there is no uniform consensus on the optimal alignment technique for TKA. Neutral mechanical alignment facilitates knee flexion and symmetrical component wear but forces the limb into an unnatural position that alters native knee kinematics through the arc of knee flexion. Kinematic alignment aims to restore native limb alignment, but the safe ranges with this technique remain uncertain and the effects of this alignment technique on component survivorship remain unknown. Anatomical alignment aims to restore predisease limb alignment and knee geometry, but existing studies using this technique are based on cadaveric specimens or clinical trials with limited follow-up times. Functional alignment aims to restore the native plane and obliquity of the joint by manipulating implant positioning while limiting soft tissue releases, but the results of high-quality studies with long-term outcomes are still awaited. The drawbacks of existing studies on alignment include the use of surgical techniques with limited accuracy and reproducibility of achieving the planned alignment, poor correlation of intraoperative data to long-term functional outcomes and implant survivorship, and a paucity of studies on the safe ranges of limb alignment. Further studies on alignment in TKA should use surgical adjuncts (e.g. robotic technology) to help execute the planned alignment with improved accuracy, include intraoperative assessments of knee biomechanics and periarticular soft-tissue tension, and correlate alignment to long-term functional outcomes and survivorship.


The Journal of Bone & Joint Surgery British Volume
Vol. 34-B, Issue 1 | Pages 9 - 13
1 Feb 1952
Jenkins SA

1. A case of spontaneous fracture of a first rib is described. 2. Its evolution from a previously intact rib through the stage of a "linear" crack to pseudarthrosis has been traced. 3. An older pseudarthrosis was present on the opposite side. 4. Alderson's observation is confirmed—that the breach in the rib is acquired. There is no need to suppose a developmental anomaly of ossification, even in a bilateral case


Bone & Joint Open
Vol. 2, Issue 6 | Pages 443 - 456
28 Jun 2021
Thompson JW Corbett J Bye D Jones A Tissingh EK Nolan J

Aims

The Exeter V40 cemented polished tapered stem system has demonstrated excellent long-term outcomes. This paper presents a systematic review of the existing literature and reports on a large case series comparing implant fractures between the Exeter V40 series; 125 mm and conventional length stem systems.

Methods

A systematic literature search was performed adhering to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria. In parallel, we performed a retrospective single centre study of Exeter V40 femoral stem prosthetic fractures between April 2003 and June 2020.


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 4 | Pages 723 - 728
1 Nov 1972
Todd RC Freeman MAR Pirie CJ

1. The femoral head has been examined in specimens taken from cadavers, patients suffering subcapital fracture of the femoral neck and patients undergoing total replacement arthroplasty for osteoarthrosis and rheumatoid arthritis. 2. Lesions have been seen, some of which appear to be uniting fatigue fractures of individual trabeculae. 3. It is suggested that excessive cyclical loading, sometimes leading to fatigue fractures, may represent a fundamental pathological process of general importance in the evolution of certain skeletal and articular diseases


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 1 | Pages 7 - 19
1 Feb 1973
Newman PH

1. Some of the more common and obvious clinical syndromes arising from mechanical and degenerative derangements of the lumbar spine are defined. 2. Some principles in the selection of cases for surgical treatment are discussed and it is stressed how small a part operative intervention plays in the overall problem of low back derangement. 3. Details of surgical technique in the eight types of syndrome are described from past experience in the author's clinic, but not without recognition of the fluidity of this comparatively new field and its continuing evolution


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1675 - 1681
1 Dec 2020
Uzoigwe CE O'Leary L Nduka J Sharma D Melling D Simmons D Barton S

Aims

Postoperative delirium (POD) and postoperative cognitive decline (POCD) are common surgical complications. In the UK, the Best Practice Tariff incentivizes the screening of delirium in patients with hip fracture. Further, a National Hip Fracture Database (NHFD) performance indicator is the reduction in the incidence of POD. To aid in its recognition, we sought to determine factors associated with POD and POCD in patients with hip fractures.

Methods

We interrogated the NHFD data on patients presenting with hip fractures to our institution from 2016 to 2018. POD was determined using the 4AT score, as recommended by the NHFD and UK Department of Health. POCD was defined as a decline in Abbreviated Mental Test Score (AMTS) of two or greater. Using logistic regression, we adjusted for covariates to identify factors associated with POD and POCD.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 251 - 258
1 Mar 2004
Rodda JM Graham HK Carson L Galea MP Wolfe R

Classifications of gait patterns in spastic diplegia have been either qualitative, based on clinical recognition, or quantitative, based on cluster analysis of kinematic data. Qualitative classifications have been much more widely used but concerns have been raised about the validity of classifications, which are not based on quantitative data. We have carried out a cross-sectional study of 187 children with spastic diplegia who attended our gait laboratory and devised a simple classification of sagittal gait patterns based on a combination of pattern recognition and kinematic data. We then studied the evolution of gait patterns in a longitudinal study of 34 children who were followed for more than one year and demonstrated the reliability of our classification


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 2 | Pages 302 - 318
1 May 1962
Stewart MJ Gilmer WS Edmonson AS

1 . Twenty patients with fibrous dysplasia, confirmed histologically, are reported and discussed in regard to classification, etiology, pathogenesis and treatment. The various fibrous or fibrocystic lesions of bone are characterised briefly for purpose of contrast, and the position of fibrous dysplasia in this heterogeneous collection is suggested. 2. The classification of fibrous dysplasia based on the degree of skeletal involvement is used, and the diagnostic, therapeutic and prognostic implications of this classification emphasised. The authors endorse the opinion that fibrous dysplasia is a developmental defect. Clinical, histological and radiographic evidence is presented to point to the distinct evolution of the monostotic lesions, to which a positive and aggressive approach is recommended


Bone & Joint Research
Vol. 9, Issue 8 | Pages 477 - 483
1 Aug 2020
Holweg P Herber V Ornig M Hohenberger G Donohue N Puchwein P Leithner A Seibert F

Aims

This study is a prospective, non-randomized trial for the treatment of fractures of the medial malleolus using lean, bioabsorbable, rare-earth element (REE)-free, magnesium (Mg)-based biodegradable screws in the adult skeleton.

Methods

A total of 20 patients with isolated, bimalleolar, or trimalleolar ankle fractures were recruited between July 2018 and October 2019. Fracture reduction was achieved through bioabsorbable Mg-based screws composed of pure Mg alloyed with zinc (Zn) and calcium (Ca) ( Mg-Zn0.45-Ca0.45, in wt.%; ZX00). Visual analogue scale (VAS) and the presence of complications (adverse events) during follow-up (12 weeks) were used to evaluate the clinical outcomes. The functional outcomes were analyzed through the range of motion (ROM) of the ankle joint and the American Orthopaedic Foot and Ankle Society (AOFAS) score. Fracture reduction and gas formation were assessed using several plane radiographs.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 729 - 732
1 Sep 1995
Cahuzac J Vardon D Sales de Gauzy J

We measured the clinical tibiofemoral (TF) angle and the intercondylar (IC) or intermalleolar (IM) distance in 427 normal European children (212 male and 215 female) aged from 10 to 16 years. In our study, girls had a constant valgus (5.5 degrees) and displayed an IM distance of < 8 cm or an IC distance of < 4 cm. By contrast, boys had a varus evolution (4.4 degrees) during the last two years of growth and displayed an IM distance of < 4 cm or an IC distance of < 5 cm. Values above these for genu varum or genu valgum may require careful follow-up and evaluation


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 1025 - 1029
1 Sep 2002
Rowe SM Moon ES Yoon TR Jung ST Lee KB Lee JJ

The treatment of osteochondritis dissecans after Legg-Calvé-Perthes’disease hasnot been clearly determined. It may be either by simple observation or surgical removal of the osteochondral fragment. We studied the evolution of the lesion in 13 children and reviewed 92 hips reported in the literature. In our patients ten showed a tendency towards spontaneous healing, one required drilling + grafting to obtain fusion, and in two there was separation into the joint. These loose bodies were in the acetabular fossa and caused no symptoms. On reviewing the literature, we found only four cases of hips with loose bodies from osteochondritis dissecans. These were lying in the inferomedial capsule and were also asymptomatic. Treatment of osteochondritis dissecans after Legg-Calvé-Perthes’ disease should therefore be conservative unless the fragment interferes with the mechanics of the hip


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 205 - 206
1 Feb 2021
Haddad FS


Bone & Joint 360
Vol. 10, Issue 2 | Pages 29 - 33
1 Apr 2021


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 610 - 618
1 Apr 2021
Batailler C Bordes M Lording T Nigues A Servien E Calliess T Lustig S

Aims

Ideal component sizing may be difficult to achieve in unicompartmental knee arthroplasty (UKA). Anatomical variants, incremental implant size, and a reduced surgical exposure may lead to over- or under-sizing of the components. The purpose of this study was to compare the accuracy of UKA sizing with robotic-assisted techniques versus a conventional surgical technique.

Methods

Three groups of 93 medial UKAs were assessed. The first group was performed by a conventional technique, the second group with an image-free robotic-assisted system (Image-Free group), and the last group with an image-based robotic arm-assisted system, using a preoperative CT scan (Image-Based group). There were no demographic differences between groups. We compared six parameters on postoperative radiographs to assess UKA sizing. Incorrect sizing was defined by an over- or under-sizing greater than 3 mm.


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 2 | Pages 299 - 311
1 May 1966
Alexander C

1. The hypothesis is advanced that the fundamental lesion of epiphysiolysis is a slow posterior growth migration of the head on the neck. 2. It is suggested that this is unrelated to the erect posture or to any abnormality of the growth cartilage. 3. Sitting stresses are measured and are postulated as the likely cause of the growth deviation. 4. The result of the deviation is an increase in the shear stress component; in the erect posture clinical epiphysiolysis is regarded as a simple fracture occurring in a proportion of deviated cases when the increased shear component exceeds the critical level appropriate to the individual. 5. It is suggested that this hypothesis explains the age and sex incidence, the left predominance, the reduced epiphysial angle found on the uninvolved hip and the clinical and radiological evolution of the disorder