A bipolar spacer was inserted for severe arthritic destruction of the shoulder in 14 patients, and followed up for a mean of 5.9 years. In one patient the operation failed because of infection. Two others required revision for loss of low-friction properties which caused
We performed revision surgery for infected arthroplasty in 98 hips (96 patients). In 28 hips infection persisted. Of the remaining 70 hips, 61 (87%) were reviewed after a mean interval of 5.9 years (1 to 17). Infection occurred in 10% of these after three years and in 26% after ten years. The infection rate after initially successful revision for septic arthroplasty is higher than after revision for aseptic
Since 1964, 3573 uncemented Ring total hip replacements of all types have been performed; 194 (5.4%) have required revision for infection,
Malalignment of the tibial component could influence the long-term survival of a total knee arthroplasty (TKA). The object of this study was to investigate the biomechanical effect of varus and valgus malalignment on the tibial component under stance-phase gait cycle loading conditions. Validated finite element models for varus and valgus malalignment by 3° and 5° were developed to evaluate the effect of malalignment on the tibial component in TKA. Maximum contact stress and contact area on a polyethylene insert, maximum contact stress on patellar button and the collateral ligament force were investigated.Objectives
Methods
We have carried out a retrospective review of 11 Souter-Strathclyde primary total elbow arthroplasties in ten patients with osteoarthritis, over a period of nine years. The diagnosis was primary osteoarthritis in nine elbows and post-traumatic arthritis in two. The mean follow-up was 68 months (15 to 117). Although no patient was symptomatic, radiological review revealed evidence of
The posterior malleolus of the ankle is the object
of increasing attention, with considerable enthusiasm for CT scanning
and surgical fixation, as expressed in a recent annotation in Cite this article:
We studied retrospectively the outcome of patellofemoral arthroplasty (PFA) using the Richards prosthesis in 51 patients (56 knees). Their mean age was 50 years (30 to 77). In 43 patients (45 knees), the American Knee Society score and the patients’ subjective judgement were assessed. Excellent or good results were obtained in 86% of cases at a mean follow-up of 17 years (15 to 21). Because of ongoing tibiofemoral osteoarthritis, two patients required a high tibial osteotomy and ten PFAs were converted to a total knee arthroplasty after a mean of 15.6 years (10 to 21). The PFAs were stable during follow-up with a
We have reviewed 100 Attenborough total knee replacements in eighty-two patients with a follow-up of one to four years and conclude that this prosthesis has a valuable place in the surgical management of patients suffering from rheumatoid arthritis and osteoarthritis with severe involvement of the knee. In 85 per cent of these knees a good result was obtained with relief from pain, and in 77 per cent a useful range of movement with a stable knee. Only two patients with
Four cases are described of localised endosteal bone lysis in the femur occurring in association with cemented femoral components that were not obviously 'loose' radiologically. In each, the area of lysis was shown at operation to be related directly to a region in which there was a local defect in the cement mantle surrounding the stem. Via the space between the stem and cement, such defects provide a route through which the contents of the joint cavity may reach the endosteal surface of the femur, subsequently leading to localised bone lysis, and later to frank
We describe the results of total knee arthroplasty (TKA) undertaken for severe, neurosyphilitic Charcot arthropathy in ten patients (19 knees). A cemented condylar, constrained prosthesis was implanted in all but two knees. The mean follow-up was 5.2 years (5 to 6). The mean knee score before operation was 36.5 points (30 to 42) which improved to 76 points (58 to 90) after operation as judged by the Hospital for Special Surgery score. At final follow-up three knees (16%) had aseptic
Of a consecutive series of 144 Attenborough knee replacements, 107 were re-examined between two and six years after operation and revealed a high incidence of complications. Wound problems were common and led to deep infection in four knees. When a patellar implant was used fracture of the patella followed in 17.5% of knees, but when the patella was not resurfaced 16% of knees developed patellofemoral pain of sufficient severity to require a further operation. In 10% of knees, definite
The aim of this study was to compare the outcomes of surgery
using growing rods in patients with severe A review of a multicentre EOS database identified 107 children
with severe EOS (major curve ≥ 90°) treated with growing rods before
the age of ten years with a minimum follow-up of two years and three
or more lengthening procedures. From the same database, 107 matched
controls with moderate EOS were identified.Aims
Patients and Methods
This paper describes the development, operative technique and results of an unconstrained total elbow arthroplasty. Forty-seven elbow replacements were carried out in 44 patients between 1974 and 1982. There was a high rate of
We carried out primary cemented total hip arthroplasty (THA) on 25 hips in 21 patients with developmental dysplasia of the hip, using autogenous acetabular bone grafts. The socket was placed at the level of the true acetabulum and bone from the femoral neck was used as graft. Five hips were excluded, leaving 20 which were followed up for a mean of 12.9 years (10 to 18). The mean modified Merle d’Aubigné and Postel functional scores were 5.6 for pain, 4.3 for mobility and 4.2 for range of movement. Radiological examination showed aseptic
Failure of massive knee endoprostheses implanted for malignant tumours of the distal femur in children presents a difficult problem. We present the results of rotationplasty undertaken under these circumstances in four boys. They had been treated initially at a mean age of 9.5 years for a stage-IIB malignant tumour of the distal femur by resection and implantation of a massive knee endoprosthesis. After a mean period of eight years and a mean of four operative procedures, there was failure of the endoprosthesis because of aseptic
A computer-based image analysis system has been developed as a research tool in total hip replacement. The system has been programmed to take multiple measurements from coronal plane radiographs. Poor quality radiographic images can be enhanced and standardised. The measurements which can be obtained include stem subsidence, cup migration, cup wear, and stem
The need for supplementary screw fixation in acetabular revisions is still widely debated. We carried out 439 acetabular revisions over an eight-year period. In 171 hips with contained or small segmental defects, the Morscher press-fit cup was used. These revisions were followed prospectively. No screws were used for additional fixation. A total of 123 hips with a mean follow-up of 7.4 years (5 to 10.5) were available for clinical and radiological review. There was no further revision of a press-fit cup for aseptic
Three madreporic prostheses in two patients were examined to evaluate resorption and formation of the surrounding bone tissue. All three prostheses were firmly fixed and had no clinical or radiographic signs of
Forty-two shoulders in 37 patients with polyarthritis were treated with Neer total shoulder replacements and reviewed 12 to 66 months afterwards. There was good pain relief and improvement in function, but the range of movement was less than that seen after replacements for osteoarthritis; this may have been related to the fact that 34 shoulders had abnormal rotator cuff tendons. Although there was a high incidence of radiolucent lines around the glenoid component, there was no clinical evidence of