A model was developed in the dog to allow both the metaphysis and epiphysis of the distal ulnar growth plate to be microsurgically revascularised from the pedicle of the
The results of surgery in 59 patients with Scheuermann's kyphosis are reported at an average follow-up of 56 months. These show that in skeletally immature patients, in whom the iliac apophysis has not yet fused to the body of the ilium, posterior fusion alone is adequate and is followed by little loss of correction. For skeletally mature patients combined
In a consecutive series of 87 operations for knee replacement prospective observations were made of the pattern of articular destruction in the form of a triangle of erosion or osteophyte formation, which is seen on the medial femoral condyle, sometimes with an associated strip on the lateral femoral condyle. These areas represent the surfaces which are normally in contact with the
Patient-specific (PS) implantation surgical technology has been introduced in recent years and a gradual increase in the associated number of surgical cases has been observed. PS technology uses a patient’s own geometry in designing a medical device to provide minimal bone resection with improvement in the prosthetic bone coverage. However, whether PS unicompartmental knee arthroplasty (UKA) provides a better biomechanical effect than standard off-the-shelf prostheses for UKA has not yet been determined, and still remains controversial in both biomechanical and clinical fields. Therefore, the aim of this study was to compare the biomechanical effect between PS and standard off-the-shelf prostheses for UKA. The contact stresses on the polyethylene (PE) insert, articular cartilage and lateral meniscus were evaluated in PS and standard off-the-shelf prostheses for UKA using a validated finite element model. Gait cycle loading was applied to evaluate the biomechanical effect in the PS and standard UKAs.Objectives
Methods
This study aimed to analyze the correlation between transverse
process (TP) fractures of the fourth (L4) and fifth (L5) lumbar
vertebrae and biomechanical and haemodynamic stability in patients
with a pelvic ring injury, since previous data are inconsistent. The study is a retrospective matched-pair analysis of patients
with a pelvic fracture according to the modified Tile AO Müller
and the Young and Burgess classification who presented to a level
1 trauma centre between January 2005 and December 2014.Aims
Patients and Methods
Unstable degenerative spondylolisthesis of the cervical spine is very rare. Slip usually occurs at the C3 on C4 or C4 on C5 levels, immediately above a stiff lower cervical spine. There are two clinical patterns: that with neurological involvement causing cervicobrachial pain or myelopathy and that with neck pain alone. The diagnosis can be made by flexion/extension radiography. All of our eight patients had localised fusion, three
The clinical, radiological and histological information on the fate of Kiel bone implants for
Eleven patients with arthrogryposis multiplex congenita neurologica have been reviewed. Distinct patterns of deformity and muscle activity were identified which have been correlated with specific levels of segmental neurological motor deficit without sensory loss. The clinical picture was consistent with localised lesions of the
1. The aetiology of a destructive lesion through a former interspace in a spine fused by ankylosing spondylitis is reviewed. 2. From the findings in three patients treated by
1. In a survey of 107 cases of Erb's paralysis, twenty-seven instances of incipient or actual posterior dislocation of the upper end of the radius were discovered. 2. The type of case in which the dislocation occurs is defined and the early clinical and radiographic signs of the displacement are described and illustrated. 3. The probable causesâmuscle imbalance and rigid splinting over a long periodâare adumbrated and the prevention and remedies are suggested. 4. The occurrence of
We report the two- to four-year results following the insertion of the Leeds-Keio prosthetic ligament for chronic
We report a case of an apparent avulsion fracture of the posteromedial margin of the medial plateau of the tibia. This was associated with a tear of the medial meniscus and rupture of the anterior cruciate ligament (ACL). This triad has been previously reported, and the plateau fracture was related to the insertion of the semimembranosus tendon. The detailed investigation of our case and some experiments on cadaver knees showed that the injury was not an avulsion fracture but was produced by varus and external rotation forces on a flexed knee. It was due to the
We report the operative technique and results of a new method of central grafting for persistent nonunion of the tibial shaft. The operation is performed through a lateral approach,
A total of 344 patients underwent bilateral total knee replacement (TKR) using a different prosthesis on each side. Four knee prostheses were used:
In 52 patients we compared the accuracy of standard anteroposterior (AP) radiography, mortise radiography and MRI with arthroscopy of the ankle for the diagnosis of a tear of the tibiofibular syndesmosis. In comparison with arthroscopy, the sensitivity, specificity and accuracy were 44.1%, 100% and 63.5% for standard AP radiography and 58.3%, 100% and 71.2% for mortise radiography. For MRI they were 100%, 93.1% and 96.2% for a tear of the
We report a new technique of talectomy for patients with Hawkins group III fracture-dislocation of the talus. Talectomy is performed through a medial incision, the foot is displaced
Total knee replacement and high tibial osteotomy are common orthopaedic operations with low complication rates. Such surgery is in close proximity to the popliteal artery (PA), the behaviour of which during flexion of the knee is poorly understood. We used Duplex ultrasonography to determine the distance of the PA from the posterior tibial surface at 0° and 90° of flexion in 100 knees. When the knee was flexed the PA was closer to the posterior tibial surface at 1 to 1.5 cm below the joint line in 24% and at 1.5 to 2 cm below the joint line in 15%. There was a high branching
1. Intertransverse fusion in the lumbar spine appears to have many advantages over previously described techniques. 2. The disadvantage of profuse bleeding can be overcome by the use of a Hastings frame and by an operative technique designed to demonstrate constant muscular and articular branches of the lumbar arteries. 3. Coagulation of these vessels by cautery and avoidance of dissection
In 30 rabbits, the medial meniscus was used to replace the
Guided growth using eight-plates is commonly used for correction
of angular limb deformities in growing children. The principle is
of tethering at the physeal periphery while enabling growth in the
rest of the physis. The method is also applied for epiphysiodesis
to correct limb-length discrepancy (LLD). Concerns have been raised
regarding the potential of this method to create an epiphyseal deformity.
However, this has not been investigated. The purpose of this study
was to detect and quantify the occurrence of deformities in the
proximal tibial epiphysis following treatment with eight-plates. A retrospective study was performed including 42 children at
a mean age of 10.8 years (3.7 to 15.7) undergoing eight-plate insertion
in the proximal tibia for correction of coronal plane deformities
or LLD between 2007 and 2015. A total of 64 plates were inserted;
48 plates (34 patients) were inserted to correct angular deformities
and 16 plates (8 patients) for LLD. Medical records, Picture Archive
and Communication System images, and conventional radiographs were
reviewed. Measurements included interscrew angle, lateral and medial
plateau slope angles measured between the plateau surface and the
line between the ends of the physis, and tibial plateau roof angle defined
as 180° minus the sum of both plateau angles. Measurements were
compared between radiographs performed adjacent to surgery and those
at latest follow-up, and between operated and non-operated plateaus. Statistical
analysis was performed using BMDP Statistical Software.Aims
Patients and Methods