The purpose of this article was to review the current literature
pertaining to the use of mobile compression devices (MCDs) for venous
thromboembolism (VTE) following total joint arthroplasty (TJA),
and to discuss the results of data from our institution. Previous studies have illustrated higher rates of post-operative
wound complications, re-operation and re-admission with the use
of more aggressive anticoagulation regimens, such as warfarin and
factor Xa inhibitors. This highlights the importance of the safety,
as well as efficacy, of the chemoprophylactic regimen.Aims
Patients and Methods
Joint replacement of the hip and knee remain
very satisfactory operations. They are, however, expensive. The
actual manufacturing of the implant represents only 30% of the final
cost, while sales and marketing represent 40%. Recently, the patents
on many well established and successful implants have expired. Companies
have started producing and distributing implants that purport to
replicate existing implants with good long-term results. The aims of this paper are to assess the legality, the monitoring
and cost saving implications of such generic implants. We also assess
how this might affect the traditional orthopaedic implant companies. Cite this article:
In England and Wales more than 175 000 hip and
knee arthroplasties were performed in 2012. There continues to be a
steady increase in the demand for joint arthroplasty because of
population demographics and improving survivorship. Inevitably though
the absolute number of periprosthetic infections will probably increase
with severe consequences on healthcare provision. The Department
of Health and the Health Protection Agency in United Kingdom established
a Surgical Site Infection surveillance service (SSISS) in 1997 to
undertake surveillance of surgical site infections. In 2004 mandatory
reporting was introduced for one quarter of each year. There has
been a wide variation in reporting rates with variable engagement
with the process. The aim of this article is to improve surgeon
awareness of the process and emphasise the importance of engaging
with SSISS to improve the quality and type of data submitted. In
Exeter we have been improving our practice by engaging with SSISS.
Orthopaedic surgeons need to take ownership of the data that are
submitted to ensure these are accurate and comprehensive. Cite this article:
The purpose of the present study was to examine the long-term
fixation of a cemented fixed-bearing polished titanium tibial baseplate
(Genesis ll). Patients enrolled in a previous two-year prospective trial (n
= 35) were recalled at ten years. Available patients (n = 15) underwent
radiostereometric analysis (RSA) imaging in a supine position using
a conventional RSA protocol. Migration of the tibial component in
all planes was compared between initial and ten-year follow-up.
Outcome scores including the Knee Society Score, Western Ontario
and McMaster Universities Arthritis Index, 12-item Short Form Health
Survey, Forgotten Joint Score, and University of California, Los
Angeles Activity Score were recorded.Aims
Patients and Methods
Up to 40% of unicompartmental knee arthroplasty (UKA) revisions are performed for unexplained pain which may be caused by elevated proximal tibial bone strain. This study investigates the effect of tibial component metal backing and polyethylene thickness on bone strain in a cemented fixed-bearing medial UKA using a finite element model (FEM) validated experimentally by digital image correlation (DIC) and acoustic emission (AE). A total of ten composite tibias implanted with all-polyethylene (AP) and metal-backed (MB) tibial components were loaded to 2500 N. Cortical strain was measured using DIC and cancellous microdamage using AE. FEMs were created and validated and polyethylene thickness varied from 6 mm to 10 mm. The volume of cancellous bone exposed to < -3000 µε (pathological loading) and < -7000 µε (yield point) minimum principal (compressive) microstrain and > 3000 µε and > 7000 µε maximum principal (tensile) microstrain was computed.Objectives
Materials and Methods
The use of robots in orthopaedic surgery is an
emerging field that is gaining momentum. It has the potential for significant
improvements in surgical planning, accuracy of component implantation
and patient safety. Advocates of robot-assisted systems describe
better patient outcomes through improved pre-operative planning
and enhanced execution of surgery. However, costs, limited availability,
a lack of evidence regarding the efficiency and safety of such systems
and an absence of long-term high-impact studies have restricted
the widespread implementation of these systems. We have reviewed
the literature on the efficacy, safety and current understanding of
the use of robotics in orthopaedics. Cite this article:
We have investigated the effect of using tranexamic
acid (TXA) during peri-acetabular osteotomy (PAO) on peri-operative
blood loss and blood transfusion requirements. In addition we analysed
whether the use of TXA was associated with an increased risk of
venous thromboembolism (VTE) following this procedure. A consecutive series of 96 PAOs, performed by a single surgeon,
were reviewed. A total of 48 patients received TXA and 48 did not.
The TXA group received a continuous infusion of TXA at a rate of
10 mg/kg/h. The primary outcome measure was the requirement for
blood transfusion. Secondary outcomes included total blood loss,
the decrease in the level of haemoglobin in the blood, the length
of hospital stay, and the complications of this treatment. The mean rate of transfusion was significantly lower in the TXA
group (62.5% The use of TXA reduced the blood loss and the rate of transfusion
after PAO significantly, without adverse effects such as an increased
rate of VTE. Cite this article:
The purpose of this study was to determine if clinical and radiological
surveillance of cartilage tumours with low biological activity is
appropriate. A total of 98 patients with an intramedullary cartilage neoplasm
in a long bone met our inclusion criteria and were included in the
study. These patients had undergone a total of 384 scans. Patients
with radiological follow-up of more than three years (46 patients)
were divided into two groups: an active group (11 patients) and
a latent group (35 patients).Aims
Patients and Methods
The October 2015 Knee Roundup360 looks at: Allergy and outcome in arthroplasty; Physiotherapy and drains not such a bad combination?; Another nail in the coffin for arthroscopists?; Graft precondition hocus pocus; Extended dose steroids in knee arthritis?; Indolent peri-prosthetic infection; Computer modelling and medial knee arthritis
A fracture of the hip is the most common serious orthopaedic
injury, and surgical site infection (SSI) is one of the most significant
complications, resulting in increased mortality, prolonged hospital
stay and often the need for further surgery. Our aim was to determine
whether high dose dual antibiotic impregnated bone cement decreases the
rate of infection. A quasi-randomised study of 848 patients with an intracapsular
fracture of the hip was conducted in one large teaching hospital
on two sites. All were treated with a hemiarthroplasty. A total
of 448 patients received low dose single-antibiotic impregnated
cement (control group) and 400 patients received high dose dual-antibiotic impregnated
cement (intervention group). The primary outcome measure was deep
SSI at one year after surgery.Aims
Patients and Methods
Patellofemoral complications are common after
total knee replacement (TKR). Leaving the patellar unsurfaced after
TKR may lead to complications such as anterior knee pain, and re-operation
to surface it. Complications after patellar resurfacing include
patellar fracture, aseptic loosening, patellar instability, polyethylene
wear, patellar clunk and osteonecrosis. Historically, patellar complications
account for one of the larger proportions of causes of failure in
TKR, however, with contemporary implant designs, complication rates
have decreased. Most remaining failures relate to patellofemoral
tracking. Understanding the causes of patellofemoral maltracking
is essential to prevent these complications as well as manage them
when they occur. Cite this article:
Medial unicompartmental knee arthroplasty (UKA) is associated
with successful outcomes in carefully selected patient cohorts.
We hypothesised that severity and location of patellofemoral cartilage
lesions significantly influences functional outcome after Oxford
medial compartmental knee arthroplasty. We reviewed 100 consecutive UKAs at minimum eight-year follow-up
(96 to 132). A single surgeon performed all procedures. Patients
were selected based on clinical and plain radiographic assessment.
All patients had end-stage medial compartment osteoarthritis (OA)
with sparing of the lateral compartment and intact anterior cruciate ligaments.
None of the patients had end-stage patellofemoral OA, but patients
with anterior knee pain or partial thickness chondral loss were
not excluded. There were 57 male and 43 female patients. The mean
age at surgery was 69 years (41 to 82). At surgery the joint was
carefully inspected for patellofemoral chondral loss and this was documented
based on severity of cartilage loss (0 to 4 Outerbridge grading)
and topographic location (medial, lateral, central, and superior
or inferior). Functional scores collected included Oxford Knee Score
(OKS), patient satisfaction scale and University College Hospital
(UCH) knee score. Intraclass correlation was used to compare chondral
damage to outcomes.Aims
Patients and Methods
Osteoarthritis (OA) is characterised by articular cartilage degradation. MicroRNAs (miRNAs) have been identified in the development of OA. The purpose of our study was to explore the functional role and underlying mechanism of miR-138-5p in interleukin-1 beta (IL-1β)-induced extracellular matrix (ECM) degradation of OA cartilage. Human articular cartilage was obtained from patients with and without OA, and chondrocytes were isolated and stimulated by IL-1β. The expression levels of miR-138-5p in cartilage and chondrocytes were both determined. After transfection with miR-138-5p mimics, allele-specific oligonucleotide (ASO)-miR-138-5p, or their negative controls, the messenger RNA (mRNA) levels of aggrecan (ACAN), collagen type II and alpha 1 (COL2A1), the protein levels of glycosaminoglycans (GAGs), and both the mRNA and protein levels of matrix metalloproteinase (MMP)-13 were evaluated. Luciferase reporter assay, quantitative real-time polymerase chain reaction (qRT-PCR), and Western blot were performed to explore whether Forkhead Box C1 (FOCX1) was a target of miR-138-5p. Further, we co-transfected OA chondrocytes with miR-138-5p mimics and pcDNA3.1 (+)-FOXC1 and then stimulated with IL-1β to determine whether miR-138-5p-mediated IL-1β-induced cartilage matrix degradation resulted from targeting FOXC1.Objectives
Materials and Methods
A key to the success of revision total knee arthroplasty
(TKA) is a safe surgical approach using an exposure that minimises
complications. In most patients, a medial parapatellar arthrotomy
with complete synovectomy is sufficient. If additional exposure
is needed, a quadriceps snip performed through the quadriceps tendon
often provides the additional exposure required. It is simple to
perform and does not alter the post-operative rehabilitative protocol.
In rare cases, in which additional exposure is needed, or when removal
of a cemented long-stemmed tibial component is required, a tibial
tubercle osteotomy (TTO) may be used. Given the risk of post-operative
extensor lag, a V-Y quadricepsplasty is rarely indicated and usually
considered only if TTO is not possible. Cite this article: