We have studied the medium- and long-term effects of femoral intramedullary nailing in 34 children. There was a high incidence of abnormality at the proximal end of the femur, including coxa valga, arrest of growth of the greater trochanter and
Thirty-nine patients underwent reconstruction of the anterior cruciate ligament with carbon-fibre and a MacIntosh repair; all had a negative pivot shift test after operation. Some patients had persistent pain, mild effusion and synovial thickening; in 10 of these patients the symptoms warranted arthroscopic examination and biopsy at a mean of 16.9 months after the repair. Arthroscopy revealed that the carbon-fibre had not induced the formation of a "new ligament" and that the repair was merely covered by a
A high percentage of hips in patients with rheumatoid arthritis presenting for total joint replacement have protrusio deformity with extremely
Osteoarthritis of the medial compartment of the knee often shows a specific pattern of anterior wear. Review of our revisions from a series of medial metal-backed Brigham unicondylar knee replacements performed between 1983 and 1989 showed that this wear pattern was common on the tibial polyethylene surface. We reviewed these cases retrospectively to compare the pattern of preoperative erosion with the wear of the prosthesis. In all 14 knees with severe anterior wear in a unicompartmental replacement, the prearthroplasty radiographs showed similar patterns, suggesting that the implanted tibial component may continue to be subjected to the same localised stresses that precipitated the failure of the original articular cartilage. Many tibial components implanted during the 1980s had an unacceptably
The ultrasonic findings in 38 children with osteomyelitis of the limb bones were analysed in four time-related groups based on the interval between the onset of symptoms and the ultrasonic examination. Deep soft-tissue swelling was the earliest sign of acute osteomyelitis; in the next stage there was periosteal elevation and a
To study the anatomy of subarticular bone and cartilage, fresh specimens of cartilage on bone from the human shoulder, hip and knee were treated with bleach or papain, or were fixed and decalcified. All were compared using scanning electron microscopy. Papain digestion selectively removed cartilage to the tidemark. The tidemark contour was highly variable; irregularities were indirectly related to degenerative lesions and were most prominent in peripheral non-weight-bearing areas of joints with central fibrillation. Decalcification exposed the interface between the bone and calcified cartilage. Collagen fibrils in articular cartilage did not interdigitate with those of bone. The subchondral bone was appositional, avascular, smooth and very
Many designs of unicompartmental knee replacement show early and mid-term failure due to polyethylene wear. We studied the wear rate of congruent polyethylene meniscal bearings retrieved from failed Oxford unicompartmental knee replacements. We examined 16 bearings, 0.8 to 12.8 years after implantation, measuring their thickness and comparing it with that of 14 unused bearings. The mean rate of penetration, which included the effects of wear at both upper and lower surfaces, was 0.036 mm per year (maximum 0.08). Bearings as
Transarticular screws at the C1 to C2 level of the cervical spine provide rigid fixation, but there is a danger of injury to a vertebral artery. The risk is related to the technical skill of the surgeon and to variations in local anatomy. We studied the grooves for the vertebral artery in 50 dry specimens of the second cervical vertebra (C2). They were often asymmetrical, and in 11 specimens one of the grooves was deep enough to reduce the internal height of the lateral mass at the point of fixation to ≤2.1 mm, and the width of the pedicle on the inferior surface of C2 to ≤2 mm. In such specimens, the placement of a transarticular screw would put the vertebral artery at extreme risk, and there is not enough bone to allow adequate fixation. Before any decision is made concerning the type of fixation to be used at C2 we recommend that a
Vertebrates have adapted to life on Earth and its constant gravitational field, which exerts load on the body and influences the structure and function of tissues. While the effects of microgravity on muscle and bone homeostasis are well described, with sarcopenia and osteoporosis observed in astronauts returning from space, the effects of shorter exposures to increased gravitational fields are less well characterized. We aimed to test how hypergravity affects early cartilage and skeletal development in a zebrafish model. We exposed zebrafish to 3 g and 6 g hypergravity from three to five days post-fertilization, when key events in jaw cartilage morphogenesis occur. Following this exposure, we performed immunostaining along with a range of histological stains and transmission electron microscopy (TEM) to examine cartilage morphology and structure, atomic force microscopy (AFM) and nanoindentation experiments to investigate the cartilage material properties, and finite element modelling to map the pattern of strain and stress in the skeletal rudiments.Aims
Methods
The radiographic and histological features of radiolucent areas at the cement-bone interface were correlated in 15 specimens retrieved at post-mortem from patients who had undergone cemented total hip arthroplasty, two weeks to 15 years prior to death. All but one of the components were securely fixed, as demonstrated by direct measurements of micromotion. Extensive radiolucencies were present in all but one case. In 11 of the 14 specimens with radiolucencies, histological examination showed that the radiolucent areas represented regions of osteoporosis and bone remodelling. The remodelling changes were characterised by osteoporosis, cancellisation and
The medial meniscus was resected from the right knees of twelve young grivet monkeys that were killed at intervals of twenty-one to 252 days after operation. The knees operated upon and the control knees were investigated radiologically and histologically. Degenerative changes occurred in the medial femoral and tibial condyles. At first there was loss of cells from the superficial layer of the articular cartilage, with a marked decrease in the acid mucopolysaccharide content of the matrix. The chondrocytes in the deeper layer of the non-calcified zone proliferated to form clones before finally degenerating. The acellular cartilage showed splitting, and with progress of the degenerative process there was
1. Experiments are described in which total infarction of the epiphysis was produced in the metatarsal bones of growing rabbits. 2. After operation both proliferation and normal maturation of the cells of the growth plate were slowed or stopped. Cartilage destruction on the metaphysial side of the growth cartilage continued with consequent
To explore the clinical relevance of joint space width (JSW) narrowing on standardized-flexion (SF) radiographs in the assessment of cartilage degeneration in specific subregions seen on MRI sequences in knee osteoarthritis (OA) with neutral, valgus, and varus alignments, and potential planning of partial knee arthroplasty. We retrospectively reviewed 639 subjects, aged 45 to 79 years, in the Osteoarthritis Initiative (OAI) study, who had symptomatic knees with Kellgren and Lawrence grade 2 to 4. Knees were categorized as neutral, valgus, and varus knees by measuring hip-knee-angles on hip-knee-ankle radiographs. Femorotibial JSW was measured on posteroanterior SF radiographs using a special software. The femorotibial compartment was divided into 16 subregions, and MR-tomographic measurements of cartilage volume, thickness, and subchondral bone area were documented. Linear regression with adjustment for age, sex, body mass index, and Kellgren and Lawrence grade was used.Aims
Methods
Metal-on-metal (MOM) is a commonly used bearing notable for its ‘suction fit’ when lubricated. In this study, we examined the capacity for MOM bearings to protect against dislocation after total hip replacement (THR). We undertook a clinical investigation to compare the rate of dislocation of MOM bearings with those of ceramic-on-polyethylene (COP) bearings and found that one MOM bearing dislocated in a series of 109 hips (0.9%) compared with nine of 145 hips (6.2%) in the COP group (p = 0.02). We also performed an in vitro investigation comparing the peak forces generated during forced separation of the two bearings of the same dimensions at velocities from 1 to 50 cm/s. This revealed that the MOM bearing generated significant resistance to separation at all velocities (maximum mean 24 N), whereas the COP did not (maximum mean 1.9 N, p <
0.001). We conclude that MOM bearings are more stable to dislocation than COP bearings as a result of the interfacial forces provided by a
We have made a retrospective review of 185 cemented Charnley total hip arthroplasties performed between 1970 and 1974 to determine the relationships between radiological variables and failure of the femoral and acetabular components. We measured the acetabular wear, the orientation of the cup, the thickness and consistency of acetabular and femoral cement mantles, radiolucency and femoral alignment. The mean follow-up was for 11.7 years. Femoral loosening was demonstrable radiologically in 15 hips (8.1%), ten (5.4%) of which were revised during the period of follow-up. Only when the first postoperative radiograph showed a
We report the results of a prospective study of 23 patients in which interstitial laser photocoagulation (ILP) was used to treat an osteoid osteoma. ILP is a technique in which tumour tissue is destroyed by direct heating using low-power laser light energy delivered by
1. A general picture of the histological state of the bone-cement junction, up to seven years after implantation, is presented as a result of the study of twenty-three human specimens. 2. The transmission of load from cement to bone occurs at isolated points through the medium of newly formed fibrocartilage. 3. It is clear that this fibrocartilage has been produced in response to mechanical pressure on fibrous tissue which has undergone compression between cement and underlying bone. 4. Direct contact exists between the surface of the cement and the newly formed fibrocartilage at these sites of load transmission. 5. Load-bearing fibrocartilage frequently shows areas of ossification extending into it from the underlying bone. 6. Where soft tissues in contact with cement are too thick or too delicate for load transmission a
The purpose of the work described was to find the average pressure on each of several areas of the acetabular cartilage of the cadaver hip under physiological loads. By obtaining load-deflection curves for one chosen area of cartilage, firstly with all the cartilage present and then after the successive removal of other areas, the fractions of the original load carried by the several areas were found, and hence the average pressures on those areas. Seventeen hips (age range twenty. two to eighty-seven years) were examined. Local pressures varied from zero to 3.4 times the average pressure in each hip. The highest pressures in the series (about 4 to 5 megaNewtons per square metre) were on areas of
The goal of closed reduction (CR) in the treatment of developmental dysplasia of the hip (DDH) is to achieve and maintain concentricity of the femoral head in the acetabulum. However, concentric reduction is not immediately attainable in all hips and it remains controversial to what degree a non-concentric reduction is acceptable. This prospective study is aimed at investigating the dynamic evolution of the hip joint space after CR in DDH using MRI. A consecutive series of patients with DDH who underwent CR since March 2014 were studied. Once the safety and stability were deemed adequate intraoperatively, reduction was accepted regardless of concentricity. Concentricity was defined when the superior joint space (SJS) and medial joint space (MJS) were both less than 2 mm, based on MRI. A total of 30 children, six boys and 24 girls, involving 35 hips, were recruited for the study. The mean age at CR was 13.7 months (3.5 to 27.6) and the mean follow-up was 49.5 months (approximately four years) (37 to 60). The joint space was evaluated along with the interval between the inverted and everted limbus.Aims
Methods
The healing of a hamstring graft to bone is the weak link in the reconstruction of a cruciate ligament using this donor material. We therefore investigated the augmentation of healing at the tendon-bone interface using calcium-phosphate cement (CPC). We performed semitendinosus autograft reconstructions of the anterior cruciate ligament on both knees of 22 New Zealand white rabbits. The interface between the grafted tendon and the bone tunnel for one knee was filled with CPC. Six rabbits were killed at the end of the first and second post-operative weeks in order to evaluate the biomechanical changes. Two rabbits were then killed sequentially at the end of weeks 1, 3, 6, 12 and 24 after operation and tissue removed for serial histological observation. Histological examination showed that the use of CPC produced early, diffuse and massive bone ingrowth. By contrast, in the non-CPC group of rabbits only a