The use of short stems has become more popular
with the increased interest in less invasive approaches for total hip
arthroplasty. The curved broaches and stem can be inserted along
a curved track to avoid the abductor attachments. Short stems have
the potential of being more bone conserving by allowing for higher
neck retention, maintenance of the medial greater trochanter, and
preferential stress transfer to the proximal femur. An initial experience with 500 new short stems (Fitmore, Zimmer
Orthopedics) stems used for total hip arthroplasty is reported.
No stems have been revised for aseptic loosening.
We describe the clinical and radiological results
of cementless primary total hip replacement (THR) in 25 patients
(18 women and seven men; 30 THRs) with severe developmental dysplasia
of the hip (DDH). Their mean age at surgery was 47 years (23 to
89). In all, 21 hips had Crowe type III dysplasia and nine had Crowe
type IV. Cementless acetabular components with standard polyethylene
liners were introduced as close to the level of the true acetabulum
as possible. The modular cementless S-ROM femoral component was
used with a low resection of the femoral neck. A total of 21 patients (25 THRs) were available for review at
a mean follow-up of 18.7 years (15.8 to 21.8). The mean modified
Harris hip score improved from 46 points pre-operatively to 90 at
final follow up (p <
0.001). A total of 15 patients (17 THRs; 57%) underwent revision of the
acetabular component at a mean of 14.6 years (7 to 20.8), all for
osteolysis. Two patients (two THRs) had symptomatic loosening. No
patient underwent femoral revision. Survival with revision of either
component for any indication was 81% at 15 years (95% CI 60.1 to
92.3), with 21 patients at risk. This technique may reduce the need for femoral osteotomy in severe
DDH, while providing a good long-term functional result. Cite this article:
A consecutive series of 320 patients with an
intracapsular fracture of the hip treated with a dynamic locking
plate (Targon Femoral Neck (TFN)) were reviewed. All surviving patients
were followed for a minimum of two years. During the follow-up period
109 patients died. There were 112 undisplaced fractures, of which three (2.7%) developed
nonunion or re-displacement and five (4.5%) developed avascular
necrosis of the femoral head. Revision to an arthroplasty was required
for five patients (4.5%). A further six patients (5.4%) had elective
removal of the plate and screws. There were 208 displaced fractures, of which 32 (15.4%) developed
nonunion or re-displacement and 23 (11.1%) developed avascular necrosis.
A further four patients (1.9%) developed a secondary fracture around
the TFN. Revision to a hip replacement was required for 43 patients
(20.7%) patients and a further seven (3.3%) had elective removal
of the plate and screws. It is suggested that the stronger distal fixation combined with
rotational stability may lead to a reduced incidence of complications
related to the healing of the fracture when compared with other
contemporary fixation devices but this needs to be confirmed in
further studies. Cite this article:
Although gradual bone transport may permit the
restoration of large-diameter bones, complications are common owing
to the long duration of external fixation. In order to reduce such
complications, a new technique of bone transport involving the use
of an external fixator and a locking plate was devised for segmental
tibial bone defects. A total of ten patients (nine men, one woman) with a mean age
at operation of 40.4 years (16 to 64) underwent distraction osteogenesis
with a locking plate to treat previously infected post-traumatic
segmental tibial defects. The locking plate was fixed percutaneously
to bridge proximal and distal segments, and was followed by external fixation.
After docking, percutaneous screws were fixed at the transported
segment through plate holes. At the same time, bone grafting was
performed at the docking site with the external fixator removed. The mean defect size was 5.9 cm (3.8 to 9.3) and mean external
fixation index was
13.4 days/cm (11.8 to 19.5). In all cases, primary union of the
docking site and distraction callus was achieved, with an excellent
bony result. There was no recurrence of deep infection or osteomyelitis,
and with the exception of one patient with a pre-existing peroneal
nerve injury, all achieved an excellent or good functional result. With short external fixation times and low complication rates,
bone transport with a locking plate could be recommended for patients
with segmental tibial defects. Cite this article:
We retrospectively reviewed 89 consecutive patients
(45 men and 44 women) with a mean age at the time of injury of 58
years (18 to 97) who had undergone external fixation after sustaining
a unilateral fracture of the distal humerus. Our objectives were
to determine the incidence of heterotopic ossification (HO); identify
risk factors associated with the development of HO; and characterise
the location, severity and resultant functional impairment attributable
to the presence of HO. HO was identified in 37 elbows (42%), mostly around the humerus
and along the course of the medial collateral ligament. HO was hazy
immature in five elbows (13.5%), mature discrete in 20 (54%), extensive
mature in 10 (27%), and complete bone bridges were present in two
elbows (5.5%). Mild functional impairment occurred in eight patients,
moderate in 27 and severe in two. HO was associated with less extension
(p = 0.032) and less overall flexion-to-extension movement (p =
0.022); the flexion-to-extension arc was <
100º in 21 elbows
(57%) with HO compared with 18 elbows (35%) without HO (p = 0.03).
HO was removed surgically in seven elbows. The development of HO was significantly associated with sustaining
a head injury (p = 0.015), delayed internal fixation (p = 0.027),
the method of fracture fixation (p = 0.039) and the use of bone
graft or substitute (p = 0.02).HO continues to be a substantial
complication after internal fixation for distal humerus fractures. Cite this article:
We report the clinical and radiological outcome
of subcapital osteotomy of the femoral neck in the management of symptomatic
femoroacetabular impingement (FAI) resulting from a healed slipped
capital femoral epiphysis (SCFE). We believe this is only the second
such study in the literature. We studied eight patients (eight hips) with symptomatic FAI after
a moderate to severe healed SCFE. There were six male and two female
patients, with a mean age of 17.8 years (13 to 29). All patients underwent a subcapital intracapsular osteotomy of
the femoral neck after surgical hip dislocation and creation of
an extended retinacular soft-tissue flap. The mean follow-up was
41 months (20 to 84). Clinical assessment included measurement of
range of movement, Harris Hip Score (HHS) and Western Ontario and McMaster
Universities Osteoarthritis score (WOMAC). Radiological assessment
included pre- and post-operative calculation of the anterior slip
angle (ASA) and lateral slip angle (LSA), the anterior offset angle
(AOA) and centre head–trochanteric distance (CTD). The mean HHS
at final follow-up was 92.5 (85 to 100), and the mean WOMAC scores
for pain, stiffness and function were 1.3 (0 to 4), 1.4 (0 to 6)
and 3.6 (0 to 19) respectively. There was a statistically significant
improvement in all the radiological measurements post-operatively.
The mean ASA improved from 36.6° (29° to 44°) to 10.3° (5° to 17°)
(p <
0.01). The mean LSA improved from 36.6° (31° to 43°) to 15.4°
(8° to 21°) (p <
0.01). The mean AOA decreased from 64.4° (50°
to 78°) 32.0° (25° to 39°) post-operatively (p <
0.01). The mean
CTD improved from -8.2 mm (-13.8 to +3.1) to +2.8 mm (-7.6 to +11.0)
(p <
0.01). Two patients underwent further surgery for nonunion.
No patient suffered avascular necrosis of the femoral head. Subcapital osteotomy for patients with a healed SCFE is more
challenging than subcapital re-orientation in those with an acute
or sub-acute SCFE and an open physis. An effective correction of
the deformity, however, can be achieved with relief of symptoms
related to impingement. Cite this article:
Acetabular bone loss is a challenging problem
facing the revision total hip replacement surgeon. Reconstruction
of the acetabulum depends on the presence of anterosuperior and
posteroinferior pelvic column support for component fixation and
stability. The Paprosky classification is most commonly used when
determining the location and degree of acetabular bone loss. Augments
serve the function of either providing primary construct stability
or supplementary fixation. When a pelvic discontinuity is encountered we advocate the use
of an acetabular distraction technique with a jumbo cup and modular
porous metal acetabular augments for the treatment of severe acetabular
bone loss and associated chronic pelvic discontinuity. Cite this article:
McFarland fractures of the medial malleolus in
children, also classified as Salter–Harris Type III and IV fractures,
are associated with a high incidence of premature growth plate arrest.
In order to identify prognostic factors for the development of complications
we reviewed 20 children with a McFarland fracture that was treated
surgically, at a mean follow-up of 8.9 years (3.5 to 17.4). Seven
children (35%) developed premature growth arrest with angular deformity.
The mean American Orthopaedic Foot and Ankle Society Ankle-Hindfoot
Scale for all patients was 98.3 (87 to 100) and the mean modified
Weber protocol was 1.15 (0 to 5). There was a significant correlation
between initial displacement (p = 0.004) and operative delay (p
= 0.007) with premature growth arrest. Both risk factors act independently
and additively, such that all children with both risk factors developed
premature arrest whereas children with no risk factor did not. We
recommend that fractures of the medial malleolus in children should
be treated by anatomical reduction and screw fixation within one
day of injury. Cite this article:
The aims of this study were to assess the efficacy
of a newly designed radiological technique (the radial groove view)
for the detection of protrusion of screws in the groove for the
extensor pollicis longus tendon (EPL) during plating of distal radial
fractures. We also aimed to determine the optimum position of the
forearm to obtain this view. We initially analysed the anatomy of
the EPL groove by performing three-dimensional CT on 51 normal forearms.
The mean horizontal angle of the groove was 17.8° (14° to 23°).
We found that the ideal position of the fluoroscopic beam to obtain
this view was 20° in the horizontal plane and 5° in the sagittal
plane. We then intra-operatively assessed the use of the radial groove
view for detecting protrusion of screws in the EPL groove in 93
fractures that were treated by volar plating. A total of 13 protruding
screws were detected. They were changed to shorter screws and these
patients underwent CT scans of the wrist immediately post-operatively.
There remained one screw that was protruding. These findings suggest
that the use of the radial groove view intra-operatively is a good
method of assessing the possible protrusion of screws into the groove
of EPL when plating a fracture of the distal radius. Cite this article:
The October 2013 Shoulder &
Elbow Roundup360 looks at: Deltoid impairment not necessarily a contra-indication for shoulder arthroplasty; The tricky radiograph; Not so asymptomatic cuff tears; Total shoulder arthroplasty: kinder on the glenoid; Barbotage for calcific tendonitis; What happens to the arthritic glenoid?; Two screws a screw too few?; Sloppy hinge best for elbow arthroplasty.
The October 2014 Research Roundup360 looks at: unpicking syndesmotic injuries: CT scans evaluated; surgical scrub suits and sterility in theatre; continuous passive motion and knee injuries; whether pain at night is melatonin related;
The aim of this study was to determine the effect
of radial extracorporeal shock-wave therapy (rESWT) on patients with
chronic tendinitis of the rotator cuff. This was a randomised controlled
trial in which 82 patients (mean age 47 years (24 to 67)) with chronic
tendinitis diagnosed clinically were randomly allocated to a treatment
group who received low-dose rESWT (three sessions at an interval
10 to 14 days, 2000 pulses, 0.11 mJ/mm2, 8 Hz) or to
a placebo group, with a follow-up of six months. The patients and
the treating orthopaedic surgeon, who were both blinded to the treatment,
evaluated the results. A total of 44 patients were allocated to
the rESWT group and 38 patients to the placebo group. A visual analogue
scale (VAS) score for pain, a Constant–Murley (CMS) score and a simple
shoulder test (SST) score significantly improved in both groups
at three and six months compared with baseline (all p ≤ 0.012).
The mean VAS was similar in both groups at three (p = 0.43) and
six months (p = 0.262). Also, the mean CMS and SST scores were similar
in both groups at six months (p = 0.815 and p = 0.834, respectively). It would thus seem that low-dose rESWT does not reduce pain or
improve function in patients chronic rotator cuff tendinitis compared
with placebo treatment. Cite this article:
It is becoming increasingly common for a patient
to have ipsilateral hip and knee replacements. The inter-prosthetic (IP)
distance, the distance between the tips of hip and knee prostheses,
has been thought to be associated with an increased risk of IP fracture.
Small gap distances are generally assumed to act as stress risers,
although there is no real biomechanical evidence to support this. The purpose of this study was to evaluate the influence of IP
distance, cortical thickness and bone mineral density on the likelihood
of an IP femoral fracture. A total of 18 human femur specimens were randomised into three
groups by bone density and cortical thickness. For each group, a
defined IP distance of 35 mm, 80 mm or 160 mm was created by choosing
the appropriate lengths of component. The maximum fracture strength
was determined using a four-point bending test. The fracture force of all three groups was similar (p = 0.498).
There was a highly significant correlation between the cortical
area and the fracture strength (r = 0.804, p <
0.001), whereas
bone density showed no influence. This study suggests that the IP distance has little influence
on fracture strength in IP femoral fractures: the thickness of the
cortex seems to be the decisive factor. Cite this article:
Patients with pain and loss of shoulder function
due to nonunion of a fracture of the proximal third of the humerus may
benefit from reverse total shoulder replacement. This paper reports
a prospective, multicentre study, involving three hospitals and
three surgeons, of 35 patients (28 women, seven men) with a mean
age of 69 years (46 to 83) who underwent a reverse total shoulder
replacement for the treatment of nonunion of a fracture of the proximal humerus.
Using Checchia’s classification, nine nonunions were type I, eight
as type II, 12 as type III and six as type IV. The mean follow-up
was 51 months (24 to 99). Post-operatively, the patients had a significant
decrease in pain (p <
0.001), and a significant improvement in
flexion, abduction, external rotation and Constant score (p <
0.001), but not in internal rotation. A total of nine complications
were recorded in seven patients: six dislocations, one glenoid loosening
in a patient who had previously suffered dislocation, one transitory
paresis of the axillary nerve and one infection. Reverse total shoulder replacement may lead to a significant
reduction in pain, improvement in function and a high degree of
satisfaction. However, the rate of complications, particularly dislocation,
was high. Cite this article:
Orientation of the acetabular component influences
wear, range of movement and the incidence of dislocation after total
hip replacement (THR). During surgery, such orientation is often
referenced to the anterior pelvic plane (APP), but APP inclination
relative to the coronal plane (pelvic tilt) varies substantially
between individuals. In contrast, the change in pelvic tilt from
supine to standing (dPT) is small for nearly all individuals. Therefore,
in THR performed with the patient supine and the patient’s coronal
plane parallel to the operating table, we propose that freehand placement
of the acetabular component placement is reliable and reflects standing
(functional) cup position. We examined this hypothesis in 56 hips
in 56 patients (19 men) with a mean age of 61 years (29 to 80) using
three-dimensional CT pelvic reconstructions and standing lateral
pelvic radiographs. We found a low variability of acetabular component
placement, with 46 implants (82%) placed within a combined range
of 30° to 50° inclination and 5° to 25° anteversion. Changing from
the supine to the standing position (analysed in 47 patients) was associated
with an anteversion change <
10° in 45 patients (96%). dPT was
<
10° in 41 patients (87%). In conclusion, supine THR appears
to provide reliable freehand acetabular component placement. In
most patients a small reclination of the pelvis going from supine
to standing causes a small increase in anteversion of the acetabular component Cite this article:
The treatment of infected nonunions is difficult.
Antibiotic cement-coated (ACC) rods provide stability as well as delivering
antibiotics. We conducted a review of 110 infected nonunions treated
with ACC rods. Patients were divided into two groups: group A (67
patients) with an infected arthrodesis, and group B (43 patients)
with an infected nonunion in a long bone. In group A, infected arthrodesis,
the success rate after the first procedure was 38/67 (57%), 29/67
(43%) required further surgery for either control of infection or
non-union. At last follow-up, five patients required amputation,
representing a limb salvage rate of 62/67 (93%) overall. In all,
29/67 (43%) presented with a bone defect with a mean size of 6.78
cm (2 to 25). Of those with a bone defect, 13/29 (45%) required
further surgery and had a mean size of defect of 7.2 cm (3.5 to
25). The cultures were negative in 17/67 (26%) and the most common
organism cultured was methicillin-resistant Cite this article:
The October 2014 Trauma Roundup360 looks at: proximal humeral fractures in children; quadrilateral surface plates in transverse acetabular fractures; sleep deprivation and poor outcomes in trauma; bipolar hemiarthroplasty; skeletal traction; forefoot fractures; telemedicine in trauma; ketamine infusion for orthopaedic injuries; and improved functional outcomes seen with trauma networks.
Modern athletes are constantly susceptible to performance-threatening injury as they push their bodies to greater limits and endure higher physical stresses. Loss of performance and training time can adversely and permanently affect a sportsperson’s career. Now more than ever with advancing medical technology the answer may lie in biologic therapy. We have been using peripheral blood stem cells (PBSC) clinically and have been able to demonstrate that stem cells differentiate into target cells to enable regenerative repair. The potential of this technique as a regenerative agent can be seen in three broad applications: 1) articular cartilage, 2) bone and 3) soft tissue. This article highlights the successful cases, among many, in all three of these applications.
Despite the worldwide usage of the cemented Contemporary
acetabular component (Stryker), no published data are available
regarding its use in patients aged <
50 years. We undertook a
mid- to long-term follow-up study, including all consecutive patients
aged
<
50 years who underwent a primary total hip replacement using
the Contemporary acetabular component with the Exeter cemented stem
between January 1999 and January 2006. There were 152 hips in 126
patients, 61 men and 65 women, mean age at surgery 37.6 years (16
to 49 yrs). One patient was lost to follow-up. Mean clinical follow-up of all implants was 7.6 years (0.9 to
12.0). All clinical questionnaire scores, including Harris hip score,
Oxford hip score and several visual analogue scales, were found
to have improved. The eight year survivorship of all acetabular
components for the endpoints revision for any reason or revision
for aseptic loosening was 94.4% (95% confidence interval (CI) 89.2
to 97.2) and 96.4% (95% CI 91.6 to 98.5), respectively. Radiological follow-up
was complete for 146 implants. The eight year survival for the endpoint
radiological loosening was 93.1% (95% CI 86.2 to 96.6). Three surviving
implants were considered radiologically loose but were asymptomatic.
The presence of acetabular osteolysis (n = 17, 11.8%) and radiolucent
lines (n = 20, 13.9%) in the 144 surviving cups indicates a need
for continued observation in the second decade of follow-up in order
to observe their influence on long-term survival. The clinical and radiological data resulting in a ten-year survival
rate >
90% in young patients support the use of the Contemporary
acetabular component in this specific patient group. Cite this article:
The osteoinductive properties of demineralised
bone matrix have been demonstrated in animal studies. However, its therapeutic
efficacy has yet to be proven in humans. The clinical properties
of AlloMatrix, an injectable calcium-based demineralised bone matrix
allograft, were studied in a prospective randomised study of 50
patients with an isolated unstable distal radial fracture treated
by reduction and Kirschner (K-) wire fixation. A total of 24 patients
were randomised to the graft group (13 men and 11 women, mean age
42.3 years (20 to 62)) and 26 to the no graft group (8 men and 18
women, mean age 45.0 years (17 to 69)). At one, three, six and nine weeks, and six and 12 months post-operatively,
patients underwent radiological evaluation, assessments for range
of movement, grip and pinch strength, and also completed the Disabilities
of Arm, Shoulder and Hand questionnaire. At one and six weeks and
one year post-operatively, bone mineral density evaluations of both
wrists were performed. No significant difference in wrist function and speed of recovery,
rate of union, complications or bone mineral density was found between
the two groups. The operating time was significantly higher in the
graft group (p = 0.004). Radiologically, the reduction parameters
remained similar in the two groups and all AlloMatrix extraosseous leakages
disappeared after nine weeks. This prospective randomised controlled trial did not demonstrate
a beneficial effect of AlloMatrix demineralised bone matrix in the
treatment of this category of distal radial fractures treated by
K-wire fixation. Cite this article: