Advertisement for orthosearch.org.uk
Results 1661 - 1680 of 2877
Results per page:
The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 904 - 911
1 Jul 2017
Wall PDH Sprowson† AP Parsons NR Parsons H Achten J Balasubramanian S Thompson P Costa ML

Aims

The aim of this study was to compare the effectiveness of a femoral nerve block and a periarticular infiltration in the management of early post-operative pain after total knee arthroplasty (TKA).

Patients and Methods

A pragmatic, single centre, two arm parallel group, patient blinded, randomised controlled trial was undertaken. All patients due for TKA were eligible. Exclusion criteria included contraindications to the medications involved in the study and patients with a neurological abnormality of the lower limb. Patients received either a femoral nerve block with 75 mg of 0.25% levobupivacaine hydrochloride around the nerve, or periarticular infiltration with 150 mg of 0.25% levobupivacaine hydrochloride, 10 mg morphine sulphate, 30 mg ketorolac trometamol and 0.25 mg of adrenaline all diluted with 0.9% saline to make a volume of 150 ml.


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 233 - 241
1 Feb 2018
Ohmori T Kitamura T Nishida T Matsumoto T Tokioka T

Aim

There is not adequate evidence to establish whether external fixation (EF) of pelvic fractures leads to a reduced mortality. We used the Japan Trauma Data Bank database to identify isolated unstable pelvic ring fractures to exclude the possibility of blood loss from other injuries, and analyzed the effectiveness of EF on mortality in this group of patients.

Patients and Methods

This was a registry-based comparison of 1163 patients who had been treated for an isolated unstable pelvic ring fracture with (386 patients) or without (777 patients) EF. An isolated pelvic ring fracture was defined by an Abbreviated Injury Score (AIS) for other injuries of < 3. An unstable pelvic ring fracture was defined as having an AIS ≥ 4. The primary outcome of this study was mortality. A subgroup analysis was carried out for patients who required blood transfusion within 24 hours of arrival in the Emergency Department and those who had massive blood loss (AIS code: 852610.5). Propensity-score matching was used to identify a cohort like the EF and non-EF groups.


Bone & Joint 360
Vol. 6, Issue 3 | Pages 33 - 35
1 Jun 2017


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 31 - 35
1 Jan 2018
Berend KR Lombardi AV Berend ME Adams JB Morris MJ

Aims

To examine incidence of complications associated with outpatient total hip arthroplasty (THA), and to see if medical comorbidities are associated with complications or extended length of stay.

Patients and Methods

From June 2013 to December 2016, 1279 patients underwent 1472 outpatient THAs at our free-standing ambulatory surgery centre. Records were reviewed to determine frequency of pre-operative medical comorbidities and post-operative need for overnight stay and complications which arose.


Bone & Joint Research
Vol. 7, Issue 1 | Pages 1 - 5
1 Jan 2018
Parsons N Griffin XL Achten J Chesser TJ Lamb SE Costa ML

Objectives

This study investigates the reporting of health-related quality of life (HRQoL) in patients following hip fracture. We compare the relative merits and make recommendations for the use for two methods of measuring HRQoL; (i) including patients who died during follow-up and (ii) including survivors only.

Methods

The World Hip Trauma Evaluation has previously reported changes in HRQoL using EuroQol-5D for patients with hip fractures. We performed additional analysis to investigate the effect of including or excluding those patients who died during the first four months of the follow-up period.


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 88 - 94
1 Jan 2018
Sprague S Petrisor B Jeray K McKay P Heels-Ansdell D Schemitsch E Liew S Guyatt G Walter SD Bhandari M

Aims

The Fluid Lavage in Open Fracture Wounds (FLOW) trial was a multicentre, blinded, randomized controlled trial that used a 2 × 3 factorial design to evaluate the effect of irrigation solution (soap versus normal saline) and irrigation pressure (very low versus low versus high) on health-related quality of life (HRQL) in patients with open fractures. In this study, we used this dataset to ascertain whether these factors affect whether HRQL returns to pre-injury levels at 12-months post-injury.

Patients and Methods

Participants completed the Short Form-12 (SF-12) and the EuroQol-5 Dimensions (EQ-5D) at baseline (pre-injury recall), at two and six weeks, and at three, six, nine and 12-months post-fracture. We calculated the Physical Component Score (PCS) and the Mental Component Score (MCS) of the SF-12 and the EQ-5D utility score, conducted an analysis using a multi-level generalized linear model, and compared differences between the baseline and 12-month scores.


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 101 - 108
1 Jan 2018
Stevenson JD Kumar VS Cribb GL Cool P

Aims

Dislocation rates are reportedly lower in patients requiring proximal femoral hemiarthroplasty than for patients undergoing hip arthroplasty for neoplasia. Without acetabular replacement, pain due to acetabular wear necessitating revision surgery has been described. We aimed to determine whether wear of the native acetabulum following hemiarthroplasty necessitates revision surgery with secondary replacement of the acetabulum after proximal femoral replacement (PFR) for tumour reconstruction.

Patients and Methods

We reviewed 100 consecutive PFRs performed between January 2003 and January 2013 without acetabular resurfacing. The procedure was undertaken in 74 patients with metastases, for a primary bone tumour in 20 and for myeloma in six. There were 48 male and 52 female patients, with a mean age of 61.4 years (19 to 85) and median follow-up of two years (interquartile range (IQR) 0.5 to 3.7 years). In total, 52 patients presented with a pathological fracture and six presented with failed fixation of a previously instrumented pathological fracture.


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 66 - 72
1 Jan 2018
Suen K Keeka M Ailabouni R Tran P

Aims

α-defensin is a biomarker which has been described as having a high degree of accuracy in the diagnosis of periprosthetic joint infection (PJI). Current meta-analyses are based on the α-defensin laboratory-based immunoassay rather than the quick on-table lateral flow test kit. This study is the first meta-analysis to compare the accuracy of the α-defensin laboratory-based immunoassay and the lateral flow test kit for the diagnosis of PJI.

Materials and Methods

A systematic review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Inclusion criteria were all clinical studies where the diagnosis of PJI was uncertain. All studies selected used the Musculoskeletal Infection Society (MSIS) or modified MSIS criteria. Two independent reviewers reviewed the studies and extracted data. A meta-analysis of results was carried out: pooled sensitivity, specificity, positive and negative likelihood ratio, heterogeneity and areas under curves are reported.


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1354 - 1365
1 Oct 2017
Patrick S McDowell A Lee A Frau A Martin U Gardner E McLorinan G Eames N

Aims

The aim of this study was to determine whether the sequential application of povidone iodine-alcohol (PVI) followed by chlorhexidine gluconate-alcohol (CHG) would reduce surgical wound contamination to a greater extent than PVI applied twice in patients undergoing spinal surgery.

Patients and Methods

A single-centre, interventional, two arm, parallel group randomised controlled trial was undertaken, involving 407 patients who underwent elective spinal surgery.

For 203 patients, the skin was disinfected before surgery using PVI (10% [w/w (1% w/w available iodine)] in 95% industrial denatured alcohol, povidone iodine; Videne Alcoholic Tincture) twice, and for 204 patients using PVI once followed by CHG (2% [w/v] chlorhexidine gluconate in 70% [v/v] isopropyl alcohol; Chloraprep with tint). The primary outcome measure was contamination of the wound determined by aerobic and anaerobic bacterial growth from samples taken after disinfection.


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 36 - 43
1 Jan 2018
Hambright D Hellman M Barrack R

Aims

The aims of this study were to examine the rate at which the positioning of the acetabular component, leg length discrepancy and femoral offset are outside an acceptable range in total hip arthroplasties (THAs) which either do or do not involve the use of intra-operative digital imaging.

Patients and Methods

A retrospective case-control study was undertaken with 50 patients before and 50 patients after the integration of an intra-operative digital imaging system in THA. The demographics of the two groups were comparable for body mass index, age, laterality and the indication for surgery. The digital imaging group had more men than the group without. Surgical data and radiographic parameters, including the inclination and anteversion of the acetabular component, leg length discrepancy, and the difference in femoral offset compared with the contralateral hip were collected and compared, as well as the incidence of altering the position of a component based on the intra-operative image.


Bone & Joint Research
Vol. 7, Issue 1 | Pages 20 - 27
1 Jan 2018
Kang K Son J Suh D Kwon SK Kwon O Koh Y

Objectives

Patient-specific (PS) implantation surgical technology has been introduced in recent years and a gradual increase in the associated number of surgical cases has been observed. PS technology uses a patient’s own geometry in designing a medical device to provide minimal bone resection with improvement in the prosthetic bone coverage. However, whether PS unicompartmental knee arthroplasty (UKA) provides a better biomechanical effect than standard off-the-shelf prostheses for UKA has not yet been determined, and still remains controversial in both biomechanical and clinical fields. Therefore, the aim of this study was to compare the biomechanical effect between PS and standard off-the-shelf prostheses for UKA.

Methods

The contact stresses on the polyethylene (PE) insert, articular cartilage and lateral meniscus were evaluated in PS and standard off-the-shelf prostheses for UKA using a validated finite element model. Gait cycle loading was applied to evaluate the biomechanical effect in the PS and standard UKAs.


Bone & Joint 360
Vol. 6, Issue 6 | Pages 41 - 43
1 Dec 2017
Foy MA


Bone & Joint 360
Vol. 6, Issue 2 | Pages 18 - 20
1 Apr 2017


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 20 - 27
1 Jan 2018
Sabah SA Moon JC Jenkins-Jones S Morgan CL Currie CJ Wilkinson JM Porter M Captur G Henckel J Chaturvedi N Kay P Skinner JA Hart AH Manisty C

Aims

The aim of this study was to determine whether patients with metal-on-metal (MoM) arthroplasties of the hip have an increased risk of cardiac failure compared with those with alternative types of arthroplasties (non-MoM).

Patients and Methods

A linkage study between the National Joint Registry, Hospital Episodes Statistics and records of the Office for National Statistics on deaths was undertaken. Patients who underwent elective total hip arthroplasty between January 2003 and December 2014 with no past history of cardiac failure were included and stratified as having either a MoM (n = 53 529) or a non-MoM (n = 482 247) arthroplasty. The primary outcome measure was the time to an admission to hospital for cardiac failure or death. Analysis was carried out using data from all patients and from those matched by propensity score.


Objectives

Posterior condylar offset (PCO) and posterior tibial slope (PTS) are critical factors in total knee arthroplasty (TKA). A computational simulation was performed to evaluate the biomechanical effect of PCO and PTS on cruciate retaining TKA.

Methods

We generated a subject-specific computational model followed by the development of ± 1 mm, ± 2 mm and ± 3 mm PCO models in the posterior direction, and -3°, 0°, 3° and 6° PTS models with each of the PCO models. Using a validated finite element (FE) model, we investigated the influence of the changes in PCO and PTS on the contact stress in the patellar button and the forces on the posterior cruciate ligament (PCL), patellar tendon and quadriceps muscles under the deep knee-bend loading conditions.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1183 - 1189
1 Sep 2017
Cho BK Kim YM Choi SM Park HW SooHoo NF

Aims

The aim of this prospective study was to evaluate the intermediate-term outcomes after revision anatomical ankle ligament reconstruction augmented with suture tape for a failed modified Broström procedure.

Patients and Methods

A total of 30 patients with persistent instability of the ankle after a Broström procedure underwent revision augmented with suture tape. Of these, 24 patients who were followed up for more than two years were included in the study. There were 13 men and 11 women. Their mean age was 31.8 years (23 to 44). The mean follow-up was 38.5 months (24 to 56) The clinical outcome was assessed using the Foot and Ankle Outcome Score (FAOS) and the Foot and Ankle Ability Measure (FAAM) score. The stability of the ankle was assessed using stress radiographs.


Bone & Joint 360
Vol. 6, Issue 3 | Pages 38 - 39
1 Jun 2017
Das A


Bone & Joint 360
Vol. 6, Issue 6 | Pages 38 - 40
1 Dec 2017


Bone & Joint Research
Vol. 6, Issue 4 | Pages 194 - 195
1 Apr 2017
Simpson AHRW Howie CR Norrie J


Bone & Joint Research
Vol. 7, Issue 1 | Pages 28 - 35
1 Jan 2018
Huang H Nightingale RW Dang ABC

Objectives

Loss of motion following spine segment fusion results in increased strain in the adjacent motion segments. However, to date, studies on the biomechanics of the cervical spine have not assessed the role of coupled motions in the lumbar spine. Accordingly, we investigated the biomechanics of the cervical spine following cervical fusion and lumbar fusion during simulated whiplash using a whole-human finite element (FE) model to simulate coupled motions of the spine.

Methods

A previously validated FE model of the human body in the driver-occupant position was used to investigate cervical hyperextension injury. The cervical spine was subjected to simulated whiplash exposure in accordance with Euro NCAP (the European New Car Assessment Programme) testing using the whole human FE model. The coupled motions between the cervical spine and lumbar spine were assessed by evaluating the biomechanical effects of simulated cervical fusion and lumbar fusion.