Total hip replacement causes a short-term increase
in the risk of mortality. It is important to quantify this and to identify
modifiable risk factors so that the risk of post-operative mortality
can be minimised. We performed a systematic review and critical
evaluation of the current literature on the topic. We identified
32 studies published over the last 10 years which provide either
30-day or 90-day mortality data. We estimate the pooled incidence
of mortality during the first 30 and 90 days following hip replacement
to be 0.30% (95% CI 0.22 to 0.38) and 0.65% (95% CI 0.50 to 0.81),
respectively. We found strong evidence of a temporal trend towards
reducing mortality rates despite increasingly co-morbid patients.
The risk factors for early mortality most commonly identified are
increasing age, male gender and co-morbid conditions, particularly
cardiovascular disease. Cardiovascular complications appear to have
overtaken fatal pulmonary emboli as the leading cause of death after
hip replacement. Cite this article:
The December 2013 Knee Roundup360 looks at: Conflict of interest and hyaluronic acid; Will time indeed tell in microfracture?; Contralateral knee pain and joint replacement outcomes; Patient satisfaction and knee replacement?; Hope in the cytokines for painful TKRs?; Pain severity, cytokines and osteoarthritis?; Quadriceps weakness and pain; and spontaneous osteonecrosis of the knee
It is becoming increasingly common for a patient
to have ipsilateral hip and knee replacements. The inter-prosthetic (IP)
distance, the distance between the tips of hip and knee prostheses,
has been thought to be associated with an increased risk of IP fracture.
Small gap distances are generally assumed to act as stress risers,
although there is no real biomechanical evidence to support this. The purpose of this study was to evaluate the influence of IP
distance, cortical thickness and bone mineral density on the likelihood
of an IP femoral fracture. A total of 18 human femur specimens were randomised into three
groups by bone density and cortical thickness. For each group, a
defined IP distance of 35 mm, 80 mm or 160 mm was created by choosing
the appropriate lengths of component. The maximum fracture strength
was determined using a four-point bending test. The fracture force of all three groups was similar (p = 0.498).
There was a highly significant correlation between the cortical
area and the fracture strength (r = 0.804, p <
0.001), whereas
bone density showed no influence. This study suggests that the IP distance has little influence
on fracture strength in IP femoral fractures: the thickness of the
cortex seems to be the decisive factor. Cite this article:
We present a comparison of patient-reported outcomes
(PROMs) in relation to patient age, in patients who had received
a total (TKR) or unicompartmental knee replacement (UKR). The outcome
was evaluated using the Oxford knee score (OKS), EuroQol (EQ-5D)
and satisfaction scores. Patients aged 65 to 84 years demonstrated
better pre-operative function scores than those aged <
65 years
(OKS, p = 0.03; EQ-5D, p = 0.048) and those aged
≥ 85 years (OKS, p = 0.03). Post-operative scores were comparable
across age groups, but a linear trend for greater post-operative
improvement in OKS and EQ-5D was seen with decreasing age (p <
0.033). The overall mean satisfaction score at six months was 84.9,
but those aged <
55 years exhibited a lower mean level of satisfaction (78.3)
compared with all other age groups (all p <
0.031). The cumulative
overall two-year revision rate was 1.3%. This study demonstrates
that good early outcomes, as measured by the OKS and EQ-5D, can
be anticipated following knee replacement regardless of the patient’s
age, although younger patients gain greater improvement. However,
the lower satisfaction in those aged
<
55 years is a concern, and suggests that outcome is not fully
encapsulated by the OKS and EQ-5D evaluation, and raises the question
whether the OKS alone is an appropriate measure of pain and function
in younger, more active individuals. Cite this article:
In a decidedly upper limb themed series of reviews this edition of Cochrane Corner summarises four new and updated reviews published by the Cochrane Bone, Joint and Muscle Trauma Group over the last few months. The tenacious reviewers at the Cochrane collaboration have turned their beady eyes to conservative treatments for shoulder dislocations and clavicle fractures along with evaluation of femoral nerve blocks in knee replacement and how to best manage entrapment injuries in children.
The cementless Oxford unicompartmental knee replacement
has been demonstrated to have superior fixation on radiographs and
a similar early complication rate compared with the cemented version.
However, a small number of cases have come to our attention where,
after an apparently successful procedure, the tibial component subsides into
a valgus position with an increased posterior slope, before becoming
well-fixed. We present the clinical and radiological findings of
these six patients and describe their natural history and the likely
causes. Two underwent revision in the early post-operative period,
and in four the implant stabilised and became well-fixed radiologically with
a good functional outcome. This situation appears to be avoidable by minor modifications
to the operative technique, and it appears that it can be treated
conservatively in most patients. Cite this article:
Clinicians are often asked by patients, “When
can I drive again?” after lower limb injury or surgery. This question
is difficult to answer in the absence of any guidelines. This review
aims to collate the currently available evidence and discuss the
factors that influence the decision to allow a patient to return
to driving. There is currently insufficient evidence for any authoritative
body to determine fitness to drive. The lack of guidance could result
in patients being withheld from driving for longer than is necessary,
or returning to driving while still unsafe. Cite this article:
We present detailed information about early morbidity
after aseptic revision knee replacement from a nationwide study.
All aseptic revision knee replacements undertaken between 1st October
2009 and 30th September 2011 were analysed using the Danish National
Patient Registry with additional information from the Danish Knee
Arthroplasty Registry. The 1218 revisions involving 1165 patients
were subdivided into total revisions, large partial revisions, partial
revisions and revisions of unicondylar replacements (UKR revisions).
The mean age was 65.0 years (27 to 94) and the median length of
hospital stay was four days (interquartile range: 3 to 5), with
a 90 days re-admission rate of 9.9%,
re-operation rate of 3.5% and mortality rate of 0.2%. The age ranges
of 51 to 55 years (p = 0.018), 76 to 80 years (p <
0.001) and ≥ 81
years (p <
0.001) were related to an increased risk of re-admission.
The age ranges of 76 to 80 years (p = 0.018) and the large partial
revision subgroup (p = 0.073) were related to an increased risk
of re-operation. The ages from 76 to 80 years (p <
0.001), age ≥ 81
years (p <
0.001) and surgical time >
120 min (p <
0.001)
were related to increased length of hospital stay, whereas the use
of a tourniquet (p = 0.008) and surgery in a low volume centre (p
= 0.013) were related to shorter length of stay. In conclusion, we found a similar incidence of early post-operative
morbidity after aseptic knee revisions as has been reported after
primary procedures. This suggests that a length of hospital stay ≤ four
days and discharge home at that time is safe following aseptic knee
revision surgery in Denmark. Cite this article:
Radiological assessment of total and unicompartmental
knee replacement remains an essential part of routine care and follow-up.
Appreciation of the various measurements that can be identified
radiologically is important. It is likely that routine plain radiographs
will continue to be used, although there has been a trend towards
using newer technologies such as CT, especially in a failing knee,
where it provides more detailed information, albeit with a higher
radiation exposure. The purpose of this paper is to outline the radiological parameters
used to evaluate knee replacements, describe how these are measured
or classified, and review the current literature to determine their
efficacy where possible.
There is little in the literature on the level
of participation in sports which patients undertake after total
hip replacement (THR). Our aims in this study were to determine
first, the level of sporting activity, second, the predictive factors
for returning to sporting activity, and third, the correlation between
participation in sports and satisfaction after THR. We retrospectively
identified 815 patients who had undergone THR between 1995 and 2005. All
were asked to complete a self-administered questionnaire regarding
their sporting activity. A total of 571 patients (71%) met the inclusion
criteria and completed the evaluation. At a mean follow-up of 9.8
years ( In conclusion, we found that most patients participate in sporting
activity after THR, regardless of the advice of their surgeon, and
that there is a correlation between the level of participation and
pre-operative function, motivation, duration of symptoms and post-operative
satisfaction. Cite this article:
The April 2015 Research Roundup360 looks at: MCID in grip strength and distal radial fracture; Experiencing rehab in a trial setting; Electrical stimulation and nerve recovery; Molecular diagnosis of TB?; Acetabular orientation: component and arthritis; Analgesia after knee arthroplasty; Bisphosphonate-associated femoral fractures
Satisfactory primary wound healing following
total joint replacement is essential. Wound healing problems can
have devastating consequences for patients. Assessment of their healing
capacity is useful in predicting complications. Local factors that
influence wound healing include multiple previous incisions, extensive
scarring, lymphoedema, and poor vascular perfusion. Systemic factors
include diabetes mellitus, inflammatory arthropathy, renal or liver
disease, immune compromise, corticosteroid therapy, smoking, and
poor nutrition. Modifications in the surgical technique are necessary
in selected cases to minimise potential wound complications. Prompt
and systematic intervention is necessary to address any wound healing
problems to reduce the risks of infection and other potential complications. Cite this article:
Although it is clear that opening-wedge high
tibial osteotomy (HTO) changes alignment in the coronal plane, which is
its objective, it is not clear how this procedure affects knee kinematics
throughout the range of joint movement and in other planes. Our research question was: how does opening-wedge HTO change
three-dimensional tibiofemoral and patellofemoral kinematics in
loaded flexion in patients with varus deformity?Three-dimensional
kinematics were assessed over 0° to 60° of loaded flexion using
an MRI method before and after opening-wedge HTO in a cohort of
13 men (14 knees). Results obtained from an iterative statistical
model found that at six and 12 months after operation, opening-wedge
HTO caused increased anterior translation of the tibia (mean 2.6
mm, p <
0.001), decreased proximal translation of the patella
(mean –2.2 mm, p <
0.001), decreased patellar spin (mean –1.4°,
p <
0.05), increased patellar tilt (mean 2.2°, p <
0.05) and
changed three other parameters. The mean Western Ontario and McMaster
Universities Arthritis Index improved significantly (p <
0.001)
from 49.6 (standard deviation ( The three-dimensional kinematic changes found may be important
in explaining inconsistency in clinical outcomes, and suggest that
measures in addition to coronal plane alignment should be considered. Cite this article:
Ensuring correct rotation of the femoral component
is a challenging aspect of patellofemoral replacement surgery. Rotation
equal to the epicondylar axis or marginally more external rotation
is acceptable. Internal rotation is associated with poor outcomes.
This paper comprises two studies evaluating the use of the medial
malleolus as a landmark to guide rotation. We used 100 lower-leg anteroposterior radiographs to evaluate
the reliability of the medial malleolus as a landmark. Assessment
was made of the angle between the tibial shaft and a line from the
intramedullary rod entry site to the medial malleolus. The femoral
cut was made in ten cadaver knees using the inferior tip of the
medial malleolus as a landmark for rotation. Rotation of the cut
relative to the anatomical epicondylar axis was assessed using CT.
The study of radiographs found the position of the medial malleolus
relative to the tibial axis is consistent. Using the inferior tip
of the medial malleolus in the cadaver study produced a mean external
rotation of 1.6° (0.1° to 3.7°) from the anatomical epicondylar
axis. Using the inferior tip of the medial malleolus to guide the
femoral cutting jig avoids internal rotation and introduces an acceptable
amount of external rotation of the femoral component.
This conversation represents an attempt by several
arthroplasty surgeons to critique several abstracts presented over
the last year as well as to use them as a jumping off point for trying
to figure out where they fit in into our current understanding of
multiple issues in modern hip and knee arthroplasty.
Tranexamic acid (TXA) has been used to reduce
blood loss during total hip arthroplasty (THA), but its use could increase
the risk of venous thromboembolic disease (VTE). Several studies
have reported that TXA does not increase the prevalence of deep
vein thrombosis (DVT), but most of those used routine chemical thromboprophylaxis,
thereby masking the potential increased risk of TXA on VTE. We wished
to ascertain whether TXA increases the prevalence of VTE in patients
undergoing THA without routine chemical thromboprophylaxis. We carried
out a retrospective case-control study in 254 patients who underwent
a primary THA, 127 of whom received TXA (1 g given pre-operatively)
and a control group of 127 who did not. All patients had mechanical
but no chemical thomboprophylaxis. Each patient was examined for
DVT by bilateral ultrasonography pre-operatively and on post-operative
days 1 and 7. TXA was found to statistically significantly increase
the incidence of total DVT on post-operative day 7 compared with
the control group (24 (18.9%) and 12 (9.4%), respectively; p <
0.05) but most cases of DVT were isolated distal DVT, with the exception
of one patient with proximal DVT in each group. One patient in the control
group developed a non-fatal symptomatic pulmonary embolism (PE).
The use of TXA did not appear to affect the prevalence of either
proximal DVT or PE. Cite this article:
We report the general mortality rate after total
knee replacement and identify independent predictors of survival. We
studied 2428 patients: there were 1127 men (46%) and 1301 (54%)
women with a mean age of 69.3 years (28 to 94). Patients were allocated
a predicted life expectancy based on their age and gender. There were 223 deaths during the study period. This represented
an overall survivorship of 99% (95% confidence interval (CI) 98
to 99) at one year, 90% (95% CI 89 to 92) at five years, and 84%
(95% CI 82 to 86) at ten years. There was no difference in survival
by gender. A greater mortality rate was associated with increasing
age (p <
0.001), American Society of Anesthesiologists (ASA)
grade (p <
0.001), smoking (p <
0.001), body mass index (BMI)
<
20 kg/m2 (p <
0.001) and rheumatoid arthritis
(p <
0.001). Multivariate modelling confirmed the independent
effect of age, ASA grade, BMI, and rheumatoid disease on mortality.
Based on the predicted average mortality, 114 patients were predicted
to have died, whereas 217 actually died. This resulted in an overall
excess standardised mortality ratio of 1.90. Patient mortality after
TKR is predicted by their demographics: these could be used to assign
an individual mortality risk after surgery.
Revision knee arthroplasty presents a number
of challenges, not least of which is obtaining solid primary fixation
of implants into host bone. Three anatomical zones exist within
both femur and tibia which can be used to support revision implants.
These consist of the joint surface or epiphysis, the metaphysis
and the diaphysis. The methods by which fixation in each zone can
be obtained are discussed. The authors suggest that solid fixation
should be obtained in at least two of the three zones and emphasise
the importance of pre-operative planning and implant selection. Cite this article:
Ankle replacements have improved significantly since the first reported attempt at resurfacing of the talar dome in 1962. We are now at a stage where ankle replacement offers a viable option in the treatment of end-stage ankle arthritis. As the procedure becomes more successful, it is important to reflect and review the current surgical outcomes. This allows us to guide our patients in the treatment of end-stage ankle arthritis. What is the better surgical treatment – arthrodesis or replacement?