Advertisement for orthosearch.org.uk
Results 1701 - 1720 of 1954
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 433 - 440
1 Apr 2012
Sridhar MS Jarrett CD Xerogeanes JW Labib SA

Given the growing prevalence of obesity around the world and its association with osteoarthritis of the knee, orthopaedic surgeons need to be familiar with the management of the obese patient with degenerative knee pain. The precise mechanism by which obesity leads to osteoarthritis remains unknown, but is likely to be due to a combination of mechanical, humoral and genetic factors.

Weight loss has clear medical benefits for the obese patient and seems to be a logical way of relieving joint pain associated with degenerative arthritis. There are a variety of ways in which this may be done including diet and exercise, and treatment with drugs and bariatric surgery. Whether substantial weight loss can delay or even reverse the symptoms associated with osteoarthritis remains to be seen.

Surgery for osteoarthritis in the obese patient can be technically more challenging and carries a risk of additional complications. Substantial weight loss before undertaking total knee replacement is advisable. More prospective studies that evaluate the effect of significant weight loss on the evolution of symptomatic osteoarthritis of the knee are needed so that orthopaedic surgeons can treat this patient group appropriately.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 648 - 655
1 May 2012
Jolles BM Grzesiak A Eudier A Dejnabadi H Voracek C Pichonnaz C Aminian K Martin E

This study compared the outcome of total knee replacement (TKR) in adult patients with fixed- and mobile-bearing prostheses during the first post-operative year and at five years’ follow-up, using gait parameters as a new objective measure. This double-blind randomised controlled clinical trial included 55 patients with mobile-bearing (n = 26) and fixed-bearing (n = 29) prostheses of the same design, evaluated pre-operatively and post-operatively at six weeks, three months, six months, one year and five years. Each participant undertook two walking trials of 30 m and completed the EuroQol questionnaire, Western Ontario and McMaster Universities osteoarthritis index, Knee Society score, and visual analogue scales for pain and stiffness. Gait analysis was performed using five miniature angular rate sensors mounted on the trunk (sacrum), each thigh and calf. The study population was divided into two groups according to age (≤ 70 years versus > 70 years).

Improvements in most gait parameters at five years’ follow-up were greater for fixed-bearing TKRs in older patients (> 70 years), and greater for mobile-bearing TKRs in younger patients (≤ 70 years). These findings should be confirmed by an extended age controlled study, as the ideal choice of prosthesis might depend on the age of the patient at the time of surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1217 - 1222
1 Sep 2011
Bonner TJ Eardley WGP Patterson P Gregg PJ

Correct positioning and alignment of components during primary total knee replacement (TKR) is widely accepted to be an important predictor of patient satisfaction and implant durability. This retrospective study reports the effect of the post-operative mechanical axis of the lower limb in the coronal plane on implant survival following primary TKR.

A total of 501 TKRs in 396 patients were divided into an aligned group with a neutral mechanical axis (± 3°) and a malaligned group where the mechanical axis deviated from neutral by > 3°. At 15 years’ follow-up, 33 of 458 (7.2%) TKRs were revised for aseptic loosening. Kaplan-Meier survival analysis showed a weak tendency towards improved survival with restoration of a neutral mechanical axis, but this did not reach statistical significance (p = 0.47).

We found that the relationship between survival of a primary TKR and mechanical axis alignment is weaker than that described in a number of previous reports.


Bone & Joint Research
Vol. 4, Issue 3 | Pages 29 - 37
1 Mar 2015
Halim T Clarke IC Burgett-Moreno MD Donaldson TK Savisaar C Bowsher JG

Objectives

Third-body wear is believed to be one trigger for adverse results with metal-on-metal (MOM) bearings. Impingement and subluxation may release metal particles from MOM replacements. We therefore challenged MOM bearings with relevant debris types of cobalt–chrome alloy (CoCr), titanium alloy (Ti6Al4V) and polymethylmethacrylate bone cement (PMMA).

Methods

Cement flakes (PMMA), CoCr and Ti6Al4V particles (size range 5 µm to 400 µm) were run in a MOM wear simulation. Debris allotments (5 mg) were inserted at ten intervals during the five million cycle (5 Mc) test.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1581 - 1581
1 Nov 2013
Cook TM

We welcome letters to the Editor concerning articles that have recently been published. Such letters will be subject to the usual stages of selection and editing; where appropriate the authors of the original article will be offered the opportunity to reply.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 115 - 117
1 Nov 2014
Mullaji A Shetty GM

Stems may improve fixation and stability of components during revision total knee replacement. However, the choice between cemented and cementless stems is not a clear one. Cemented stems offer several advantages in terms of versatility, mechanical stability, surgical technique and clinical outcome over their cementless counterpart.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):115–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 12 | Pages 1660 - 1664
1 Dec 2011
Judge A Arden NK Price A Glyn-Jones S Beard D Carr AJ Dawson J Fitzpatrick R Field RE

We obtained pre-operative and six-month post-operative Oxford hip (OHS) and knee scores (OKS) for 1523 patients who underwent total hip replacement and 1784 patients who underwent total knee replacement. They all also completed a six-month satisfaction question.

Scatter plots showed no relationship between pre-operative Oxford scores and six-month satisfaction scores. Spearman’s rank correlation coefficients were -0.04 (95% confidence interval (CI) -0.09 to 0.01) between OHS and satisfaction and 0.04 (95% CI -0.01 to 0.08) between OKS and satisfaction. A receiver operating characteristic (ROC) curve analysis was used to identify a cut-off point for the pre-operative OHS/OKS that identifies whether or not a patient is satisfied with surgery. We obtained an area under the ROC curve of 0.51 (95% CI 0.45 to 0.56) for hip replacement and 0.56 (95% CI 0.51 to 0.60) for knee replacement, indicating that pre-operative Oxford scores have no predictive accuracy in distinguishing satisfied from dissatisfied patients.

In the NHS widespread attempts are being made to use patient-reported outcome measures (PROMs) data for the purpose of prioritising patients for surgery. Oxford hip and knee scores have no predictive accuracy in relation to post-operative patient satisfaction. This evidence does not support their current use in prioritising access to care.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 19 - 23
1 Jan 2015
den Hartog YM Mathijssen NMC Hannink G Vehmeijer SBW

After implementation of a ‘fast-track’ rehabilitation protocol in our hospital, mean length of hospital stay for primary total hip arthroplasty decreased from 4.6 to 2.9 nights for unselected patients. However, despite this reduction there was still a wide range across the patients’ hospital duration. The purpose of this study was to identify which specific patient characteristics influence length of stay after successful implementation of a ‘fast-track’ rehabilitation protocol. A total of 477 patients (317 female and 160 male, mean age 71.0 years; 39.3 to 92.6, mean BMI 27.0 kg/m2;18.8 to 45.2) who underwent primary total hip arthroplasty between 1 February 2011 and 31 January 2013, were included in this retrospective cohort study. A length of stay greater than the median was considered as an increased duration. Logistic regression analyses were performed to identify potential factors associated with increased durations. Median length of stay was two nights (interquartile range 1), and the mean length of stay 2.9 nights (1 to 75). In all, 266 patients had a length of stay ≤ two nights. Age (odds ratio (OR) 2.46; 95% confidence intervals (CI) 1.72 to 3.51; p <  0.001), living situation (alone vs living together with cohabitants, OR 2.09; 95% CI 1.33 to 3.30; p = 0.002) and approach (anterior approach vs lateral, OR 0.29; 95% CI 0.19 to 0.46; p <  0.001) (posterolateral approach vs lateral, OR 0.24; 95% CI 0.10 to 0.55; p < 0.001) were factors that were significantly associated with increased length of stay in the multivariable logistic regression model.

Cite this article: Bone Joint J 2015;97-B:19–23.


Bone & Joint 360
Vol. 1, Issue 2 | Pages 33 - 34
1 Apr 2012
Benazzo F


Bone & Joint 360
Vol. 4, Issue 1 | Pages 6 - 11
1 Feb 2015
Manktelow A Bloch B

This review examines the future of total hip arthroplasty, aiming to avoid past mistakes


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1377 - 1381
1 Oct 2012
Jaiswal PK Bentley G Carrington RWJ Skinner JA Briggs TWR

We analysed whether a high body mass index (BMI) had a deleterious effect on outcome following autologous chondrocyte implantation (ACI) or matrix-carried autologous chondrocyte implantation (MACI) for the treatment of full-thickness chondral defects of the knee from a subset of patients enrolled in the ACI vs MACI trial at The Royal National Orthopaedic Hospital.

The mean Modified Cincinnati scores (MCS) were significantly higher (p < 0.001) post-operatively in patients who had an ideal body weight (n = 53; 20 to 24.9 kg/m2) than in overweight (n = 63; 25 to 30 kg/m2) and obese patients (n = 22; > 30 kg/m2). At a follow-up of two years, obese patients demonstrated no sustained improvement in the MCS. Patients with an ideal weight experienced significant improvements as early as six months after surgery (p = 0.007). In total, 82% of patients (31 of 38) in the ideal group had a good or excellent result, compared with 49% (22 of 45) of the overweight and 5.5% (one of 18) in the obese group (p < 0.001). There was a significant negative relationship between BMI and the MCS 24 months after surgery (r = -0.4, p = 0.001).

This study demonstrates that obese patients have worse knee function before surgery and experience no sustained benefit from ACI or MACI at two years after surgery. There was a correlation between increasing BMI and a lower MCS according to a linear regression analysis. On the basis of our findings patient selection can be more appropriately targeted.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 788 - 792
1 Jun 2013
Chen JY Lo NN Jiang L Chong HC Tay DKJ Chin PL Chia S Yeo SJ

We prospectively followed 171 patients who underwent bilateral unicompartmental knee replacement (UKR) over a period of two years. Of these, 124 (72.5%) underwent a simultaneous bilateral procedure and 47 (27.5%) underwent a staged procedure. The mean cumulative operating time and length of hospital stay were both shorter in the simultaneous group, by 22.5 minutes (p < 0.001) and three days (p < 0.001), respectively. The mean reduction in haemoglobin level post-operatively was greater by 0.15 g/dl in the simultaneous group (p = 0.023), but this did not translate into a significant increase in the number of patients requiring blood transfusion (p = 1.000). The mean hospital cost was lower by $8892 in the simultaneous group (p < 0.001). There was no significant difference in the rate of complications between the groups, and at two-year follow-up there was no difference in the outcomes between the two groups.

We conclude that simultaneous bilateral UKR can be recommended as an appropriate treatment for patients with bilateral medial compartment osteoarthritis of the knee.

Cite this article: Bone Joint J 2013;95-B:788–92.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1356 - 1361
1 Oct 2012
Streit MR Walker T Bruckner T Merle C Kretzer JP Clarius M Aldinger PR Gotterbarm T

The Oxford mobile-bearing unicompartmental knee replacement (UKR) is an effective and safe treatment for osteoarthritis of the medial compartment. The results in the lateral compartment have been disappointing due to a high early rate of dislocation of the bearing. A series using a newly designed domed tibial component is reported.

The first 50 consecutive domed lateral Oxford UKRs in 50 patients with a mean follow-up of three years (2.0 to 4.3) were included. Clinical scores were obtained prospectively and Kaplan-Meier survival analysis was performed for different endpoints. Radiological variables related to the position and alignment of the components were measured.

One patient died and none was lost to follow-up. The cumulative incidence of dislocation was 6.2% (95% confidence interval (CI) 2.0 to 17.9) at three years. Survival using revision for any reason and aseptic revision was 94% (95% CI 82 to 98) and 96% (95% CI 85 to 99) at three years, respectively. Outcome scores, visual analogue scale for pain and maximum knee flexion showed a significant improvement (p < 0.001). The mean Oxford knee score was 43 (sd 5.3), the mean Objective American Knee Society score was 91 (sd 13.9) and the mean Functional American Knee Society score was 90 (sd 17.5). The mean maximum flexion was 127° (90° to 145°). Significant elevation of the lateral joint line as measured by the proximal tibial varus angle (p = 0.04) was evident in the dislocation group when compared with the non-dislocation group.

Clinical results are excellent and short-term survival has improved when compared with earlier series. The risk of dislocation remains higher using a mobile-bearing UKR in the lateral compartment when compared with the medial compartment. Patients should be informed about this complication. To avoid dislocations, care must be taken not to elevate the lateral joint line.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 937 - 940
1 Jul 2012
Manopoulos P Havet E Pearce O Lardanchet JF Mertl P

This was a retrospective analysis of the medium- to long-term results of 46 TC3 Sigma revision total knee replacements using long uncemented stems in press-fit mode.

Clinical and radiological analysis took place pre-operatively, at two years post-operatively, and at a mean follow-up of 8.5 years (4 to 12). The mean pre-operative International Knee Society (IKS) clinical score was 42 points (0 to 74), improving to 83.7 (52 to 100) by the final follow-up. The mean IKS score for function improved from 34.3 points (0 to 80) to 64.2 (15 to 100) at the final follow-up. At the final follow-up 30 knees (65.2%) had an excellent result, seven (15.2%) a good result, one (2.2%) a medium and eight (17.4%) a poor result. There were two failures, one with anteroposterior instability and one with aseptic loosening.

The TC3 revision knee system, when used with press-fit for long intramedullary stems and cemented femoral and tibial components, in both septic and aseptic revisions, results in a satisfactory clinical and radiological outcome, and has a good medium- to long-term survival rate.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1499 - 1505
1 Nov 2012
Kim J Kasat NS Bae J Kim S Oh S Lim H

The purpose of this study was to measure the radiological parameters of femoral component alignment of the Oxford Phase 3 unicompartmental knee replacement (UKR), and evaluate their effect on clinical outcome. Multiple regression analysis was used to examine the relative contributions of the radiological assessment of femoral component alignment in 189 consecutive UKRs performed by a single surgeon. The American Knee Society scores were compared between groups, defined as being within or outside recommended tolerances of the position of the femoral component. For the flexion/extension position 21 UKRs (11.1%) lay outside the recommended limits, and for posterior overhang of the femoral component nine (4.8%) lay outside the range. The pre-operative hip/knee/ankle (HKA) angle, narrowest canal distance from the distal femoral entry point of the alignment jig and coronal entry-point position had significant effects on the flexion/extension position. Pre-operative HKA angle had a significant influence on posterior overhang of the femoral component. However, there was no significant difference in American Knee Society scores relative to the position of the femoral component.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 66 - 69
1 Nov 2014
Lombardi Jr AV Berend KR Adams JB

The common recommended treatment for infected total hip replacement is two-staged exchange including removal of all components. However, removal of well-fixed femoral stems can result in structural bone damage. We recently reported on an alternative treatment of partial two-stage exchange used in selected cases, in which a well-fixed femoral stem was left and only the acetabular component removed, the joint space was debrided thoroughly, an antibiotic-laden polymethylmethacrylate spacer was moulded using a bulb-type syringe and placed in the acetabulum, intravenous antibiotics were administered during the interval, and delayed re-implantation was performed. In 19 patients treated with this technique from January 2000 to January 2011, 89% were free of infection at a mean follow-up of four years (2 to 11). Since then, disposable silicone moulds have become available to fabricate spacers in separate femoral and head units. The head spacer mould, which incorporates various neck taper adapter options, greatly facilitates the technique of partial two-stage exchange. We report our early experience using disposable silicone head spacer moulds for partial two-stage exchange in seven patients with infected primary hip replacements.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):66–9


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 118 - 121
1 Nov 2014
Lachiewicz PF Watters TS

Metaphyseal bone loss is common with revision total knee replacement (RTKR). Using the Anderson Orthopaedic Research Institute (AORI) classification, type 2-B and type 3 defects usually require large metal blocks, bulk structural allograft or highly porous metal cones. Tibial and femoral trabecular metal metaphyseal cones are a unique solution for large bone defects. These cones substitute for bone loss, improve metaphyseal fixation, help correct malalignment, restore the joint line and may permit use of a shorter stem. The technique for insertion involves sculpturing of the remaining bone with a high speed burr and rasp, followed by press-fit of the cone into the metaphysis. The fixation and osteoconductive properties of the porous cone outer surface allow ingrowth and encourage long-term biological fixation. The revision knee component is then cemented into the porous cone inner surface, which provides superior fixation compared with cementing into native but deficient metaphyseal bone. The advantages of the cone compared with allograft include: technical ease, biological fixation, no resorption, and possibly a lower risk of infection. The disadvantages include: difficult extraction and relatively short-term follow-up. Several studies using cones report promising short-term results for the reconstruction of large bone defects in RTKR.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):118–21.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1287 - 1289
1 Oct 2014
Nikiphorou E Konan S MacGregor AJ Haddad FS Young A

There has been an in increase in the availability of effective biological agents for the treatment of rheumatoid arthritis as well as a shift towards early diagnosis and management of the inflammatory process. This article explores the impact this may have on the place of orthopaedic surgery in the management of patients with rheumatoid arthritis.

Cite this article: Bone Joint J 2014;96-B:1287–9


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 914 - 918
1 Jul 2012
Jameson SS Baker PN Charman SC Deehan DJ Reed MR Gregg PJ Van der Meulen JH

We compared thromboembolic events, major haemorrhage and death after knee replacement in patients receiving either aspirin or low-molecular-weight heparin (LMWH). Data from the National Joint Registry for England and Wales were linked to an administrative database of hospital admissions in the English National Health Service. A total of 156 798 patients between April 2003 and September 2008 were included and followed for 90 days. Multivariable risk modelling was used to estimate odds ratios adjusted for baseline risk factors (AOR). An AOR < 1 indicates that risk rates are lower with LMWH than with aspirin. In all, 36 159 patients (23.1%) were prescribed aspirin and 120 639 patients (76.9%) were prescribed LMWH. We found no statistically significant differences between the aspirin and LMWH groups in the rate of pulmonary embolism (0.49% vs 0.45%, AOR 0.88 (95% confidence interval (CI) 0.74 to 1.05); p = 0.16), 90-day mortality (0.39% vs 0.45%, AOR 1.13 (95% CI 0.94 to 1.37); p = 0.19) or major haemorrhage (0.37% vs 0.39%, AOR 1.01 (95% CI 0.83 to 1.22); p = 0.94). There was a significantly greater likelihood of needing to return to theatre in the aspirin group (0.26% vs 0.19%, AOR 0.73 (95% CI 0.58 to 0.94); p = 0.01). Between patients receiving LMWH or aspirin there was only a small difference in the risk of pulmonary embolism, 90-day mortality and major haemorrhage.

These results should be considered when the existing guidelines for thromboprophylaxis after knee replacement are reviewed.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1141 - 1142
1 Sep 2014
Haddad FS