Aims. Congenital pseudarthrosis of the tibia (CPT) has traditionally been a difficult condition to treat, with high complication rates, including nonunion, refractures, malalignment, and leg length discrepancy. Surgical approaches to treatment of CPT include intramedullary rodding, external fixation, combined intramedullary rodding and external fixation, vascularized fibular graft, and most recently cross-union. The current study aims to compare the outcomes and complication rates of cross-union versus other surgical approaches as an index surgery for the management of CPT. Our hypothesis was that a good index surgery for CPT achieves union and minimizes complications such as refractures and limb length discrepancy. Methods. A multicentre study was conducted involving two institutions in Singapore and China. All patients with CPT who were surgically managed between January 2009 and December 2021 were included. The patients were divided
Aims. The Exeter femoral stem has a cemented, polished taper-slip design, and an excellent track record. The current range includes short-length options for various offsets, but less is known about the performance of these stems. The aim of this study was to compare the survival of short-length stems with standard-length Exeter stems. Methods. A systematic review of all studies reporting the use of short-length Exeter stems in primary total hip arthroplasty (THA) was undertaken. Survival data, the indication for revision, and patient-reported outcomes were gathered from observational and randomized studies. Studies
Aims. The aim of this study was to evaluate the outcome of complex radial head fractures at mid-term follow-up, and determine whether open reduction and internal fixation (ORIF) or radial head arthroplasty (RHA) should be recommended for surgical treatment. Methods. Patients who underwent surgery for complex radial head fractures (Mason type III, ≥ three fragments) were divided into two groups (ORIF and RHA) and propensity score matching was used to individually match patients
Aims. We estimated the prevalence of people living with at least one hip, knee, or shoulder arthroplasty in the Netherlands. Methods. We included the first hip (n = 416,333), knee (n = 314,569), or shoulder (n = 23,751) arthroplasty of each patient aged ≥ 40 years between 2007 and 2022 (hip/knee) or 2014 and 2022 (shoulder) from the Dutch Arthroplasty Register (LROI). Data on the size of the Dutch population were obtained from Statistics Netherlands. Annual incidences and deaths from hip and knee arthroplasty since 2010, and shoulder arthroplasty since 2015, were observed from the LROI. Annual incidences and deaths before those years were estimated using Poisson regression analyses and parametric survival models
Aims. This study aimed to answer the following questions: do 3D-printed models lead to a more accurate recognition of the pattern of complex fractures of the elbow?; do 3D-printed models lead to a more reliable recognition of the pattern of these injuries?; and do junior surgeons benefit more from 3D-printed models than senior surgeons?. Methods. A total of 15 orthopaedic trauma surgeons (seven juniors, eight seniors) evaluated 20 complex elbow fractures for their overall pattern (i.e. varus posterior medial rotational injury, terrible triad injury, radial head fracture with posterolateral dislocation, anterior (trans-)olecranon fracture-dislocation, posterior (trans-)olecranon fracture-dislocation) and their specific characteristics. First, fractures were assessed
Aims. Successful cell therapy in hip osteonecrosis (ON) may help to avoid ON progression or total hip arthroplasty (THA), but the achieved bone regeneration is unclear. The aim of this study was to evaluate amount and location of bone regeneration obtained after surgical injection of expanded autologous mesenchymal stromal cells from the bone marrow (BM-hMSCs). Methods. A total of 20 patients with small and medium-size symptomatic stage II femoral head ON treated with 140 million BM-hMSCs through percutaneous forage in the EudraCT 2012-002010-39 clinical trial were retrospectively evaluated through preoperative and postoperative (three and 12 months) MRI. Then, 3D reconstruction of the original lesion and the observed postoperative residual damage after bone regeneration were analyzed and compared per group
Aims. The COVID-19 pandemic has disrupted the provision of arthroplasty services in England, Wales, and Northern Ireland. This study aimed to quantify the backlog, analyze national trends, and predict time to recovery. Methods. We performed an analysis of the mandatory prospective national registry of all independent and publicly funded hip, knee, shoulder, elbow, and ankle replacements in England, Wales, and Northern Ireland between January 2019 and December 2022 inclusive, totalling 729,642 operations. The deficit was calculated per year compared to a continuation of 2019 volume. Total deficit of cases between 2020 to 2022 was expressed as a percentage of 2019 volume. Sub-analyses were performed
Aims. Rates of reverse total shoulder arthroplasty (rTSA) continue to grow. Glenoid bone loss and deformity remains a technical challenge to the surgeon and may reduce improvements in patients’ outcomes. However, there is no consensus as to the optimal surgical technique to best reconstruct these patients’ anatomy. This review aims to compare the outcomes of glenoid bone grafting versus augmented glenoid prostheses in the management of glenoid bone loss in primary reverse total shoulder arthroplasty. Methods. This systematic review and meta-analysis evaluated study-level data in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. We performed searches of Medline (Ovid), Embase (Ovid), and PubMed from their dates of inception to January 2022. From included studies, we analyzed data for preoperative and postoperative range of motion (ROM), patient-reported functional outcomes, and complication rates. Results. A total of 13 studies (919 shoulders) were included in the analysis. The mean age of patients at initial evaluation was 72.2 years (42 to 87), with a mean follow-up time of 40.7 months (24 to 120). Nine studies with 292 rTSAs evaluated the use of bone graft and five studies with 627 rTSAs evaluated the use of augmented glenoid baseplates. One study was analyzed in both groups. Both techniques demonstrated improvement in patient-reported outcome measures and ROM assessment, with augmented prostheses outperforming bone grafting on improvements in the American Shoulder and Elbow Surgeons Score. There was a higher complication rate (8.9% vs 3.5%; p < 0.001) and revision rate among the bone grafting group compared with the patients who were treated with augmented prostheses (2.4% vs 0.6%; p = 0.022). Conclusion. This review provides strong evidence that both bone graft and augmented glenoid baseplate techniques to address glenoid bone loss give excellent ROM and functional outcomes in primary rTSA. The use of augmented
Aims. The aim of this systematic review and meta-analysis was to gather epidemiological information on selected musculoskeletal injuries and to provide pooled injury-specific incidence rates. Methods. PubMed (National Library of Medicine) and Scopus (Elsevier) databases were searched. Articles were eligible for inclusion if they reported incidence rate (or count with population at risk), contained data on adult population, and were written in English language. The number of cases and population at risk were collected, and the pooled incidence rates (per 100,000 person-years) with 95% confidence intervals (CIs) were calculated by using either a fixed or random effects model. Results. The screening of titles yielded 206 articles eligible for inclusion in the study. Of these, 173 (84%) articles provided sufficient information to be included in the pooled incidence rates. Incidences of fractures were investigated in 154 studies, and the most common fractures in the whole adult population
Aims. Implant waste during total hip arthroplasty (THA) represents a significant cost to the USA healthcare system. While studies have explored methods to improve THA cost-effectiveness, the literature comparing the proportions of implant waste by intraoperative technology used during THA is limited. The aims of this study were to: 1) examine whether the use of enabling technologies during THA results in a smaller proportion of wasted implants compared to navigation-guided and conventional manual THA; 2) determine the proportion of wasted implants by implant type; and 3) examine the effects of surgeon experience on rates of implant waste by technology used. Methods. We identified 104,420 implants either implanted or wasted during 18,329 primary THAs performed on 16,724 patients between January 2018 and June 2022 at our institution. THAs were separated by technology used: robotic-assisted (n = 4,171), imageless navigation (n = 6,887), and manual (n = 7,721). The primary outcome of interest was the rate of implant waste during primary THA. Results. Robotic-assisted THA resulted in a lower proportion (1.5%) of implant waste compared to navigation-guided THA (2.0%) and manual THA (1.9%) (all p < 0.001). Both navigated and manual THA were more likely to waste acetabular shells (odds ratio (OR) 4.5 vs 3.1) and polyethylene liners (OR 2.2 vs 2.0) compared to robotic-assisted THA after adjusting for demographic and perioperative factors, such as surgeon experience (p < 0.001). While implant waste decreased with increasing experience for procedures performed manually (p < 0.001) or with navigation (p < 0.001), waste rates for robotic-assisted THA did not differ
Aims. Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey. Methods. NJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact rotator cuff were included. Metal and ceramic humeral head prostheses were matched within separate TSA and HA groups using propensity scores
Aims. Spinal anaesthesia has seen increased use in contemporary primary total knee arthroplasties (TKAs). However, controversy exists about the benefits of spinal in comparison to general anaesthesia in primary TKAs. This study aimed to investigate the pain control, length of stay (LOS), and complications associated with spinal versus general anaesthesia in primary TKAs from a single, high-volume academic centre. Methods. We retrospectively identified 17,690 primary TKAs (13,297 patients) from 2001 to 2016 using our institutional total joint registry, where 52% had general anaesthesia and 48% had spinal anaesthesia. Baseline characteristics were similar between cohorts with a mean age of 68 years (SD 10), 58% female (n = 7,669), and mean BMI of 32 kg/m. 2. (SD 7). Pain was evaluated using oral morphine equivalents (OMEs) and numerical pain rating scale (NPRS) data. Complications including 30- and 90-day readmissions were studied. Data were analyzed using an inverse probability of treatment weighted model
Aims. This study evaluated the definitions developed by the European Bone and Joint Infection Society (EBJIS) 2021, the International Consensus Meeting (ICM) 2018, and the Infectious Diseases Society of America (IDSA) 2013, for the diagnosis of periprosthetic joint infection (PJI). Methods. In this single-centre, retrospective analysis of prospectively collected data, patients with an indicated revision surgery after a total hip or knee arthroplasty were included between 2015 and 2020. A standardized diagnostic workup was performed, identifying the components of the EBJIS, ICM, and IDSA criteria in each patient. Results. Of 206 included patients, 101 (49%) were diagnosed with PJI with the EBJIS definition. IDSA and ICM diagnosed 99 (48%) and 86 (42%) as infected, respectively. A total of 84 cases (41%) had an infection
Aims. The Coronal Plane Alignment of the Knee (CPAK) classification is a simple and comprehensive system for predicting pre-arthritic knee alignment. However, when the CPAK classification is applied in the Asian population, which is characterized by more varus and wider distribution in lower limb alignment, modifications in the boundaries of arithmetic hip-knee-ankle angle (aHKA) and joint line obliquity (JLO) should be considered. The purposes of this study were as follows: first, to propose a modified CPAK classification
Aims. Avascular femoral head necrosis in the context of gymnastics is a rare but serious complication, appearing similar to Perthes’ disease but occurring later during adolescence. Based on 3D CT animations, we propose repetitive impact between the main supplying vessels on the posterolateral femoral neck and the posterior acetabular wall in hyperextension and external rotation as a possible cause of direct vascular damage, and subsequent femoral head necrosis in three adolescent female gymnasts we are reporting on. Methods. Outcome of hip-preserving head reduction osteotomy combined with periacetabular osteotomy was good in one and moderate in the other up to three years after surgery;
Aims. Deprivation underpins many societal and health inequalities. COVID-19 has exacerbated these disparities, with access to planned care falling greatest in the most deprived areas of the UK during 2020. This study aimed to identify the impact of deprivation on patients on growing waiting lists for planned care. Methods. Questionnaires were sent to orthopaedic waiting list patients at the start of the UK’s first COVID-19 lockdown to capture key quantitative and qualitative aspects of patients’ health. A total of 888 respondents were divided into quintiles, with sampling stratified
Aims. There is no consensus regarding optimum timing and frequency of ultrasound (US) for monitoring response to Pavlik harness (PH) treatment in developmental dysplasia of the hip (DDH). The purpose of our study was to determine if a limited-frequency hip US assessment had an adverse effect on treatment outcomes compared to traditional comprehensive US monitoring. Methods. This study was a single-centre noninferiority randomized controlled trial. Infants aged under six months whose hips were reduced and centred in the harness at initiation of treatment (stable dysplastic or subluxable), or initially decentred (subluxated or dislocated) but reduced and centred within four weeks of PH treatment, were randomized to our current standard US monitoring protocol (every clinic visit) or to a limited-frequency US protocol (US only at end of treatment). Groups were compared
Aims. The aim of this study was to compare the cost-effectiveness of cemented hemiarthroplasty (HA) versus hydroxyapatite-coated uncemented HA for the treatment of displaced intracapsular hip fractures in older adults. Methods. A within-trial economic evaluation was conducted
Aims. The aim of this study is to report the long-term outcomes of instrumented femoral revisions with impaction allograft bone grafting (IBG) using the X-change femoral revision system at 30 years after introduction of the technique. Methods. We updated the outcomes of our previous study,
Aims. This study investigated the effects of β-caryophyllene (BCP) on protecting bone from vitamin D deficiency in mice fed on a diet either lacking (D-) or containing (D+) vitamin D. Methods. A total of 40 female mice were assigned to four treatment groups (n = 10/group): D+ diet with propylene glycol control, D+ diet with BCP, D-deficient diet with control, and D-deficient diet with BCP. The D+ diet is a commercial