The April 2013 Trauma Roundup360 looks at: ankle sprains; paediatric knee haemarthroses; evidence to support a belief; ‘Moonboot’ saves the day; pamphlets and outcomes; poor gait in pilons; lactate and surgical timing; and marginal results with marginal impaction.
We report the functional and socioeconomic long-term
outcome of patients with pelvic ring injuries. We identified 109 patients treated at a Level I trauma centre
between 1973 and 1990 with multiple blunt orthopaedic injuries including
an injury to the pelvic ring, with an Injury Severity Score (ISS)
of ≥ 16. These patients were invited for clinical review at a minimum
of ten years after the initial injury, at which point functional
results, general health scores and socioeconomic factors were assessed. In all 33 isolated anterior (group A), 33 isolated posterior
(group P) and 43 combined anterior/posterior pelvic ring injuries
(group A/P) were included. The mean age of the patients at injury
was 28.8 years (5 to 55) and the mean ISS was 22.7 (16 to 44). At review the mean Short-Form 12 physical component score for
the A/P group was 38.71 (22.12 to 56.56) and the mean Hannover Score
for Polytrauma Outcome subjective score was 67.27 (12.48 to 147.42),
being significantly worse compared with the other two groups (p =
0.004 and p = 0.024, respectively). A total of 42 patients (39%)
had a limp and 12 (11%) required crutches. Car or public transport
usage was restricted in 16 patients (15%). Overall patients in groups
P and A/P had a worse outcome. The long-term outcome of patients
with posterior or combined anterior/posterior pelvic ring injuries
is poorer than of those with an isolated anterior injury. Cite this article:
The aim of this study was to validate the use of three models of fracture fixation in the assessment of technical skills. We recruited 21 subjects (six experts, seven intermediates, and eight novices) to perform three procedures: application of a dynamic compression plate on a cadaver porcine model, insertion of an unreamed tibial intramedullary nail, and application of a forearm external fixator, both on synthetic bone models. The primary outcome measures were the Objective Structural Assessment of technical skills global rating scale on video recordings of the procedures which were scored by two independent expert observers, and the hand movements of the surgeons which were analysed using the Imperial College Surgical Assessment Device. The video scores were significantly different for the three groups in all three procedures (p <
0.05), with excellent inter-rater reliability (α = 0.88). The novice and intermediate groups specifically were significantly different in their performance with dynamic compression plate and intramedullary nails (p <
0.05). Movement analysis distinguished between the three groups in the dynamic compression plate model, but a ceiling effect was demonstrated in the intramedullary nail and external fixator procedures, where intermediates and experts performed to comparable standards (p >
0.6). A total of 85% (18 of 21) of the subjects found the dynamic compression model and 57% (12 of 21) found all the models acceptable tools of assessment. This study has validated a low-cost, high-fidelity porcine dynamic compression plate model using video rating scores for skills assessment and movement analysis. It has also demonstrated that Synbone models for the application of and intramedullary nail and an external fixator are less sensitive and should be improved for further assessment of surgical skills in trauma. The availability of valid objective tools of assessment of surgical skills allows further studies into improving methods of training.
Richard Carey Smith is an orthopaedic oncology surgeon with fellowship training in the UK, USA, Australia and Canada, and has worked in Zambia, Zimbabwe and Papa New Guinea. David Wood is head of the University Department of Orthopaedics in Perth, Western Australia. He did his masters in Africa, and first experienced Papa New Guinea on his medical elective, starting a lifelong commitment to medical aid work there.
In a global environment of rising costs and limited funds, robotic and computer-assisted orthopaedic technologies could provide the means to drive a necessary revolution in arthroplasty productivity. Robots have been used to operate on humans for 20 years, but the adoption of the technology has lagged behind that of the manufacturing industry. The use of robots in surgery should enable cost savings by reducing instrumentation and inventories, and improving accuracy. Despite these benefits, the orthopaedic community has been resistant to change. If the ergonomics and economics are right, robotic technology just might transform the provision of joint replacement.
Seven stiff total knee arthroplasties are presented
to illustrate the roles of: 1) manipulation under general anesthesia;
2) multiple concurrent diagnoses in addition to stiffness; 3) extra-articular
pathology; 4) pain as part of the stiffness triad (pain and limits
to flexion or extension); 5) component internal rotation; 6) multifactorial
etiology; and 7) surgical exposure in this challenging clinical
problem.
We conducted a prospective follow-up MRI study
of originally asymptomatic healthy subjects to clarify the development
of Modic changes in the cervical spine over a ten-year period and
to identify related factors. Previously, 497 asymptomatic healthy
volunteers with no history of cervical trauma or surgery underwent
MRI. Of these, 223 underwent a second MRI at a mean follow-up of
11.6 years (10 to 12.7). These 223 subjects comprised 133 men and 100
women with a mean age at second MRI of 50.5 years (23 to 83). Modic
changes were classified as not present and types 1 to 3. Changes
in Modic types over time and relationships between Modic changes
and progression of degeneration of the disc or clinical symptoms
were evaluated. A total of 31 subjects (13.9%) showed Modic changes at
follow-up: type 1 in nine, type 2 in 18, type 3 in two, and types In the cervical spine over a ten-year period
The 2010 Fellows undertook a six-week journey through centres of orthopaedic excellence along the East Coast of Canada and the United States. What we learned and gained from the experience and each other is immeasurable, but five areas particularly stand out; education, research, service delivery, financial insights and professional development.
We report a 30-year-old patient who was involved in a high-velocity road traffic accident and developed a left-sided hemiparesis, which was noted in the post-operative period following bilateral femoral intramedullary nailing. CT scanning of the brain revealed infarcts in the right frontal and parietal lobes in the distribution of the right middle cerebral artery. CT angiography showed occlusion of the right internal carotid artery consistent with internal carotid artery dissection. He was anticoagulated and nine months later was able to walk independently. An awareness of this injury is needed to diagnose blunt trauma to the internal carotid artery. Even in the absence of obvious neck trauma, carotid artery dissection should be suspected in patients with a neurological deficit in the peri-operative period.
We describe three patients with pre-ganglionic (avulsion) injuries of the brachial plexus which caused a partial Brown-Séquard syndrome.
A man of 52 years of age had a
This retrospective cohort study was conducted to investigate whether operative treatment of patients with a pertrochanteric femoral fracture outside working hours is associated with an increased risk of complications and higher mortality. During the study period 165 patients were operated on outside working hours and 123 were operated on during working hours (08.00 to 17.00). There was no difference in the rate of early complications (outside working hours 33% versus working hours 33%, p = 0.91) or total complications during follow-up (outside working hours 40% versus working hours 41%, p = 0.91). Both in-hospital mortality (outside working hours 12% versus working hours 11%, p = 0.97) and mortality after one year (outside working hours 29% versus working hours 27%, p = 0.67) were comparable. Adjustment for possible confounders by multivariate logistic regression analysis revealed no increased risk of complications when patients were operated on outside working hours. On the basis of these data, there is no medical reason to postpone operative reduction and fixation in patients with a proximal femoral fracture until working hours.
Dedifferentiated chordoma is a rare and aggressive variant of the conventional tumour in which an area undergoes transformation to a high-grade lesion, typically fibrous histiocytoma, fibrosarcoma, and rarely, osteosarcoma or rhabdomyosarcoma. The dedifferentiated component dictates overall survival, with smaller areas of dedifferentiation carrying a more favourable prognosis. Although it is more commonly diagnosed in recurrences and following radiotherapy, there have been a few reports of spontaneous development. We describe four such cases, which were diagnosed
We have examined the accuracy of 143 consecutive ultrasound scans of patients who subsequently underwent shoulder arthroscopy for rotator-cuff disease. All the scans and subsequent surgery were performed by an orthopaedic surgeon using a portable ultrasound scanner in a one-stop clinic. There were 78 full thickness tears which we confirmed by surgery or MRI. Three moderate-size tears were assessed as partial-thickness at ultrasound scan (false negative) giving a sensitivity of 96.2%. One partially torn and two intact cuffs were over-diagnosed as small full-thickness tears by ultrasound scan (false positive) giving a specificity of 95.4%. This gave a positive predictive value of 96.2% and a negative predictive value of 95.4%. Estimation of tear size was more accurate for large and massive tears at 96.5% than for moderate (88.8%) and small tears (91.6%). These results are equivalent to those obtained by several studies undertaken by experienced radiologists. We conclude that ultrasound imaging of the shoulder performed by a sufficiently-trained orthopaedic surgeon is a reliable time-saving practice to identify rotator-cuff integrity.
We report the case of a 12-year-old boy with polyostotic fibrous dysplasia of the upper femur in whom a massive customised polyethylene prosthesis functioned successfully for more than fifty years.