Advertisement for orthosearch.org.uk
Results 1821 - 1840 of 2637
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 235 - 240
1 Mar 1991
Allan D Lavoie G McDonald S Oakeshott R Gross A

We followed prospectively 69 patients with 78 proximal femoral allografts performed for revision of total hip arthroplasty for an average of 36 months (range 29 to 68). Large fragment proximal femoral allografts and cortical strut allografts were successful in 85%. Grafts smaller than 3 cm in length (calcar grafts) were clinically successful in 81%, but 50% underwent significant radiographic resorption. We conclude that large proximal femoral allografts and cortical strut allografts provide dependable reconstruction of bone stock deficiencies during revision total hip arthroplasty


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 436 - 442
1 Apr 2018
Choi HG Lee YB Rhyu SH Kwon BC Lee JK

Aims

The aim of this study was to compare the rate of mortality and causes of death in Korean patients who undergo surgery for a fracture of the hip, up to 11 years after the injury, with a control group from the general population.

Materials and Methods

National cohort data from Korean Health Insurance Review and Assessment Service – National Sample Cohort were used. A ratio of 1:4 matched patients with a fracture who underwent surgery (3383, fracture group) between 2003 and 2012, and controls (13 532) were included. The matches were processed for age, gender, income, and region of residence. We also undertook analyses of subgroups according to age and gender. The mean follow-up was 4.45 years (1 to 11).


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 787 - 791
1 Sep 1997
Clarke MT Green JS Harper WM Gregg PJ

We performed routine venography after operation in a consecutive series of 252 patients with total joint arthroplasties in whom no form of routine chemical or mechanical prophylaxis had been used. The prevalence of deep-vein thrombosis (DVT) was 32% (16% distal, 16% proximal) after total hip replacement and 66% (50% distal, 16% proximal) after total knee replacement (p < 0.001). We did not treat distal DVT. There were only two readmissions within three months of surgery because of thromboembolic disease. There were two deaths within this period, neither of which was due to pulmonary embolism


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 4 | Pages 441 - 446
1 Nov 1980
Fenelon G Von Foerster G Engelbrecht E

Eleven patients underwent disarticulation for infected arthroplasty of the hip. Exchange total hip arthroplasty or conversion to a Girdlestone excision arthroplasty had been undertaken previously an average of 2.9 times. The indications for disarticulation were as a life-saving measure, or as a result of severe infection of soft tissue and bone, loss of bone stock, or vascular injury. While the indications for this drastic operation were highly individual, there were instances where disarticulation could have been avoided if repeated exchange operations had been eschewed in deference to a Girdlestone procedure


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 811 - 815
1 Sep 1991
Berg M Bergman B Hoborn J

Clean air in the operating room is important during joint replacement surgery. We compared monochromatic ultraviolet radiation of 254 nm with the use of a Charnley-Howorth air enclosure by bacterial air-sampling during 113 total hip arthroplasties. Air samples were taken continuously at the edge of the wound and every 15 minutes at a site 130 cm from the operating table. We also tested the effect of occlusive clothing for all personnel. Ultraviolet light was more efficient than the ultra-clean air enclosure, and occlusive clothing on its own or in combination also produced improvement. The implications of these findings are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 752 - 755
1 Nov 1987
Harley J Wilkinson J

Total hip replacement for adults with unreduced congenital dislocation presents a difficult problem because soft-tissue contractures usually prevent sitting at the normal anatomical level. Extensive soft-tissue division or a high-level acetabulum leads to reduced function and poor fixation of the components. We describe a new technique for hip replacement in such cases. The shortened abductors and flexors are released proximally and excision of the upper third of the ilium allows them to be repaired without tension, while providing bone graft to reconstruct the acetabular roof. We report 12 such replacements in 10 patients with good results and few early complications


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 614 - 618
1 May 2000
Fujita H Iida H Ido K Matsuda Y Oka M Nakamura T

We evaluated the efficacy and biocompatibility of porous apatite-wollastonite glass ceramic (AW-GC) as an intramedullary plug in total hip replacement (THR) for up to two years in 22 adult beagle dogs. Cylindrical porous AW-GC rods (70% porosity, mean pore size 200 3m) were prepared. Four dogs were killed at 1, 3, 6 and 12 months each and six at 24 months after implantation. Radiological evaluation confirmed the efficacy of porous AW-CG as an intramedullary plug. Histological evaluation showed osteoconduction at one month and resorption of the porous AW-GC, which was replaced by newly-formed bone, at 24 months. Our findings indicate that porous AW-GC can be used clinically as an intramedullary plug in THR


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 48 - 49
1 Jan 2000
Mant MJ Russell DB Johnston DWC Donahue PA

The administration of heparin during operation has been reported to enhance the efficacy of thromboprophylaxis in patients undergoing total hip replacement. We have performed a small pilot study in which intraoperative doses of heparin were given in addition to the usual postoperative thromboprophylaxis with enoxaparin in 32 patients undergoing total knee replacement. The primary endpoint was deep-vein thrombosis (DVT) as demonstrated by bilateral venography on 6 ± 2 days after operation. Sixteen patients developed DVT; in two the thrombosis was proximal as well as distal and in one the occurrence was bilateral. There was one major haemorrhage. These results are similar to those obtained with the use of postoperative thromboprophylaxis with enoxaparin alone. They do not provide support for the initiation of a larger randomised trial of this approach to management


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 1075 - 1081
1 Sep 2001
Doherty AT Howell RT Ellis LA Bisbinas I Learmonth ID Newson R Case CP

The long-term biological effects of wear debris are unknown. We have investigated whether there is any evidence of cumulative mutagenic damage in peripheral blood lymphocytes of patients undergoing revision arthroplasty of predominantly metal-on-plastic total hip replacements compared with those at primary arthroplasty. There was a threefold increase in aneuploidy and a twofold increase in chromosomal translocations which could not be explained by the confounding variables of smoking, gender, age and diagnostic radiographs. In the patients with TiVaAl prostheses there was a fivefold increase in aneuploidy but no increase in chromosomal translocations. By contrast, in patients with cobalt-chrome prostheses there was a 2.5-fold increase in aneuploidy and a 3.5-fold increase in chromosomal translocations. In six patients with stainless-steel prostheses there was no increase in either aneuploidy or chromosomal translocations. Our results suggest that future epidemiological studies of the putative long-term risks of joint replacement should take into account the type of alloy used in the prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 400 - 403
1 May 1996
Voggenreiter G Assenmacher S Klaes W Schmit-Neuerburg K

We have used total hip replacement combined with cemented intramedullary nailing to treat a selected group of nine patients with pathological fractures of the proximal femur and impending fractures of the shaft due to metastases. One patient died from cardiopulmonary failure on the third postoperative day, but the others were able to walk within the first week after operation. Complications included one recurrent dislocation of the THR and one fracture of an osteolytic lesion of the femoral shaft during nail insertion. Both were managed successfully. The hybrid osteosynthesis which we describe is an alternative to the use of tumour or long-stem prostheses; it has the advantage of preserving bone stock and muscle attachments


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 767 - 771
1 Jul 2001
Biedermann R Stöckl B Krismer M Mayrhofer P Ornstein E Franzén H

Our aim was to determine whether tantalum markers improved the accuracy and/or precision of methods for the measurement of migration in total hip replacement based on conventional measurements without mathematical correction of the data, and with Ein Bild Roentgen Analyse – Femoral Component Analysis (EBRA-FCA) which allows a computerised correction. Three observers independently analysed 13 series of roentgen-stereophotogrammetric-analysis (RSA)-compatible radiographs (88). Data were obtained from conventional measurements, EBRA-FCA and the RSA method and all the results were compared with the RSA data. Radiological evaluation was also used to quantify in how many radiographs the intraosseous position of the bone markers had been simulated. The results showed that tantalum markers improve reliability whereas they do not affect accuracy for conventional measurements and for EBRA-FCA. Because of the danger of third-body wear their implantation should be avoided unless they are an integral part of the method


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 205 - 211
1 Mar 1990
Paavilainen T Hoikka V Solonen K

We report the short-term results of 100 cementless total hip replacements in 52 severely dysplastic and 48 totally dislocated hips, with some new technical solutions to the problems involved. In cases with a very narrow iliac bone, the acetabular screw ring is seated below the true cotyloid area. In hips with tight flexor and abductor muscles or with deformities of the proximal femur, various osteotomies were performed. Special attention was paid to careful pre-operative planning and precise operative technique. In spite of a high complication rate the results were generally good and even patients who required reoperation were satisfied with the final result


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 5 | Pages 809 - 813
1 Nov 1985
Amir D Mogle P Weinberg H

A family of 114 people in six generations, of whom 45 were affected by multiple epiphysial dysplasia, was described in this Journal in May 1960. We have been able to review them again 23 years later, and also to report on the type and incidence of the disease in more children and in a further generation. The relative severity of the disease in different branches of the family has been unchanged through the generations. Patients who were previously hopelessly crippled can today be rehabilitated by total hip replacement. Genetic counselling and birth control have reduced the relative and absolute numbers of affected children; this is tending to make the disease self-limiting


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 384 - 394
1 Mar 2005
Angliss R Fujii G Pickvance E Wainwright AM Benson MKD

The outcome of displaced hips treated by Somerville and Scott’s method was assessed after more than 25 years. A total of 147 patients (191 displaced hips) was reviewed which represented an overall follow-up of 65.6%. The median age at the index operation was two years. During the first five years, 25 (13%) hips showed signs of avascular change. The late development of valgus angulation of the neck, after ten years, was seen in 69 (36%) hips. Further operations were frequently necessary. Moderate to severe osteoarthritis developed at a young age in 40% of the hips. Total hip replacement or arthrodesis was necessary in 27 (14%) hips at a mean age of 36.5 years. Risk factors identified were high dislocation, open reduction, and age at the original operation. Two groups of patients were compared according to outcome. All the radiographic indices were different between the two groups after ten years, but most were similar before. It takes a generation to establish the prognosis, although some early indicators may help to predict outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 822 - 824
1 Nov 1992
Godsiff S Emery R Heywood-Waddington M Thomas T

A prospective, randomised and independently assessed trial of the Ring UPM total hip replacement showed that the quality of the early result was better if the femoral prosthesis was cemented than if it was not. More patients with cemented prostheses were painfree at four months (58% cemented:42% uncemented) and at one year (63% cemented:50% uncemented), but at two years pain relief was equal in both groups. At two years significantly more patients with cemented prostheses could walk without support (96% cemented:62% uncemented, p = 0.01 to 0.05). There is a need for more similar trials to compare the results of contemporary designs of cemented and uncemented total hip prostheses


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1167 - 1175
1 Sep 2017
Luna IE Kehlet H Peterson B Wede HR Hoevsgaard SJ Aasvang EK

Aims

The purpose of this study was to assess early physical function after total hip or knee arthroplasty (THA/TKA), and the correlation between patient-reported outcome measures, physical performance and actual physical activity (measured by actigraphy).

Patients and Methods

A total of 80 patients aged 55 to 80 years undergoing THA or TKA for osteoarthritis were included in this prospective cohort study. The main outcome measure was change in patient reported hip or knee injury and osteoarthritis outcome score (HOOS/KOOS) from pre-operatively until post-operative day 13 (THA) or 20 (TKA). Secondary measures were correlations to objectively assessed change in physical performance (paced-walk, chair-stand, stair-climb tests) at day 14 (THA) or 21 (TKA) and actual physical activity (actigraphy) measured at day 12 and 13 (THA) or 19 and 20 (TKA).


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 85 - 91
1 Jan 1996
Önsten I Carlsson ÅS Sanzén L Besjakov J

A consecutive series of 30 total hip replacements using a hydroxyapatite (HA)-coated, modular implant (Omnifit) was followed clinically and by roentgen stereophotogrammetric analysis for two years and compared with two control groups, one of 27 cemented Charnley sockets and one of 40 cemented Charnley stems. Omnifit sockets with a central gap between the dome of the socket and the acetabular bone in the postoperative radiographs, migrated less than sockets without such gaps (p = 0.01). After adjustment for patient-related factors (age, gender and weight), no significant difference was found between the two prostheses with respect to micromotion and wear. We conclude that the early fixation of the HA-coated Omnifit prosthesis compares with that of the cemented Charnley prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 25 - 28
1 Jan 1991
Lalor P Revell P Gray A Wright S Railton G Freeman M

Tissues from five patients who underwent revision operations for failed total hip replacements were found to contain large quantities of particulate titanium. In four cases this metal must have come from titanium alloy screws used to fix the acetabular component; in the fifth case it may also have originated from a titanium alloy femoral head. Monoclonal antibody labelling showed abundant macrophages and T-lymphocytes, in the absence of B-lymphocytes, suggesting sensitisation to titanium. Skin patch testing with dilute solutions of titanium salts gave negative results in all five patients. However, two of them had a positive skin test to a titanium-containing ointment


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 921 - 927
1 Jul 2005
Glyn-Jones S Gill HS Beard DJ McLardy-Smith P Murray DW

Polished, tapered stems are now widely used for cemented total hip replacement and many such designs have been introduced. However, a change in stem geometry may have a profound influence on stability. Stems with a wide, rectangular proximal section may be more stable than those which are narrower proximally. We examined the influence of proximal geometry on stability by comparing the two-year migration of the Exeter stem with a more recent design, the CPS-Plus, which has a wider shoulder and a more rectangular cross-section. The hypothesis was that these design features would increase rotational stability. Both stems subsided approximately 1 mm relative to the femur during the first two years after implantation. The Exeter stem was found to rotate into valgus (mean 0.2°, . sd. 0.42°) and internally rotate (mean 1.28°, . sd. 0.99°). The CPS-Plus showed no significant valgus rotation (mean 0.2°, . sd. 0.42°) or internal rotation (mean −0.03°, . sd. 0.75°). A wider, more rectangular cross-section improves rotational stability and may have a better long-term outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 46 - 50
1 Jan 1999
Sieber H Rieker CB Köttig P

Osteolysis is due to particulate wear debris and is responsible for the long-term failure of total hip replacements. It has stimulated the development of alternative joint surfaces such as metal-on-metal or ceramic-on-ceramic implants. Since 1988 the second-generation metal-on-metal implant Metasul has been used in over 60 000 hips. Analysis of 118 retrieved specimens of the head or cup showed rates of wear of approximately 25 μm for the whole articulation per year in the first year, decreasing to about 5 μm per year after the third. Metal surfaces have a ‘self-polishing’ capacity. Scratches are worn out by further joint movement. Volumetric wear was decreased some 60-fold compared with that of metal-on-polyethylene implants, suggesting that second-generation metal-on-metal prostheses may considerably reduce osteolysis