Aims. Loosening of components after
Aims. The aim of this study was to describe the prevalence and patterns of neuropathic pain over one year in a cohort of patients with chronic post-surgical pain at three months following
Aims. Total hip arthroplasty (THA) and
Aims. The aim of this study was to compare the migration of the femoral component, five years postoperatively, between patients with a highly cross-linked polyethylene (HXLPE) insert and those with a conventional polyethylene (PE) insert in an uncemented Triathlon fixed insert cruciate-retaining
Aims. A retrospective longitudinal study was conducted to compare directly volumetric wear of retrieved polyethylene inserts to predicted volumetric wear modelled from individual gait mechanics of
To investigate the impact of consecutive perioperative care transitions on in-hospital recovery of patients who had primary total knee arthroplasty (TKA) over an 11-year period. This observational cohort study used electronic health record data from all patients undergoing preoperative screening for primary TKA at a Northern Netherlands hospital between 2009 and 2020. In this timeframe, three perioperative care transitions were divided into four periods: Baseline care (Joint Care, n = 171; May 2009 to August 2010), Function-tailored (n = 404; September 2010 to October 2013), Fast-track (n = 721; November 2013 to May 2018), and Prehabilitation (n = 601; June 2018 to December 2020). In-hospital recovery was measured using inpatient recovery of activities (IROA), length of stay (LOS), and discharge to preoperative living situation (PLS). Multivariable regression models were used to analyze the impact of each perioperative care transition on in-hospital recovery.Aims
Methods
In a prospective multicentre study we investigated
variations in pain management used by knee arthroplasty surgeons
in order to compare the differences in pain levels among patients
undergoing
We have previously reported the short-term radiological
results of a randomised controlled trial comparing kinematically
aligned
Tranexamic acid (TEA), an inhibitor of fibrinolysis,
reduces blood loss after routine
Objectives. Numerous complications following
We performed a randomised controlled trial comparing
computer-assisted surgery (CAS) with conventional surgery (CONV)
in
There are several methods for evaluating stability
of the joint during
The incidence of anterior knee pain following
total knee replacement (TKR) is reported to be as high as 49%. The source
of the pain is poorly understood but the soft tissues around the
patella have been implicated. In theory circumferential electrocautery denervates the patella
thereby reducing efferent pain signals. However, there is mixed
evidence that this practice translates into improved outcomes. We aimed to investigate the clinical effect of intra-operative
circumpatellar electrocautery in patients undergoing
Objectives. Lower limb muscle power is thought to influence outcome following
total knee replacement (TKR). Post-operative deficits in muscle
strength are commonly reported, although not explained. We hypothesised
that post-operative recovery of lower limb muscle power would be
influenced by the number of satellite cells in the quadriceps muscle at
time of surgery. . Methods. Biopsies were obtained from 29 patients undergoing
Although it has been suggested that the outcome
after revision of a unicondylar knee replacement (UKR) to total knee
replacement (TKR) is better when the mechanism of failure is understood,
a comparative study on this subject has not been undertaken. A total of 30 patients (30 knees) who underwent revision of their
unsatisfactory UKR to
A consecutive series of patients with a hydroxyapatite-coated
uncemented
Improvements in the surgical technique of total
knee replacement (TKR) are continually being sought. There has recently
been interest in three-dimensional (3D) pre-operative planning using
magnetic resonance imaging (MRI) and CT. The 3D images are increasingly
used for the production of patient-specific models, surgical guides
and custom-made implants for
There is conflicting evidence about the merits
of mobile bearings in
In posterior stabilised total knee replacement
(TKR) a larger femoral component is sometimes selected to manage the
increased flexion gap caused by resection of the posterior cruciate
ligament. However, concerns remain regarding the adverse effect
of the increased anteroposterior dimensions of the femoral component
on the patellofemoral (PF) joint. Meanwhile, the gender-specific
femoral component has a narrower and thinner anterior flange and
is expected to reduce the PF contact force. PF contact forces were
measured at 90°, 120°, 130° and 140° of flexion using the NexGen
Legacy Posterior Stabilized (LPS)-Flex Fixed Bearing Knee system
using Standard, Upsized and Gender femoral components during
Component malalignment can be associated with
pain following
This study assessed the effect of concomitant
back pain on the Oxford knee score (OKS), Short-Form (SF)-12 and patient
satisfaction after
We identified a group of patients from the Swedish
Arthroplasty Register who reported no relief of pain or worse pain
one year after a
We compared lower limb coronal alignment measurements
obtained pre- and post-operatively with long-leg radiographs and
computer navigation in patients undergoing primary total knee replacement
(TKR). A series of 185 patients had their pre- and post-implant
radiological and computer-navigation system measurements of coronal alignment
compared using the Bland-Altman method. The study included 81 men
and 104 women with a mean age of 68.5 years (32 to 87) and a mean
body mass index of 31.7 kg/m. 2. (19 to 49). Pre-implant
Bland–Altman limits of agreement were -9.4° to 8.6° with a repeatability
coefficient of 9.0°. The Bland–Altman plot showed a tendency for the
radiological measurement to indicate a higher level of pre-operative
deformity than the corresponding navigation measurement. Post-implant
limits of agreement were -5.0° to 5.4° with a repeatability coefficient
of 5.2°. The tendency for valgus knees to have greater deformity
on the radiograph was still seen, but was weaker for varus knees. . The alignment seen or measured intra-operatively during
Patient-reported outcome measures (PROMs) are
increasingly being used to assess functional outcome and patient satisfaction.
They provide a framework for comparisons between surgical units,
and individual surgeons for benchmarking and financial remuneration.
Better performance may bring the reward of more customers as patients and
commissioners seek out high performers for their elective procedures.
Using National Joint Registry (NJR) data linked to PROMs we identified
22 691 primary total knee replacements (TKRs) undertaken for osteoarthritis
in England and Wales between August 2008 and February 2011, and
identified the surgical factors that influenced the improvements
in the Oxford knee score (OKS) and EuroQol-5D (EQ-5D) assessment
using multiple regression analysis. After correction for patient
factors the only surgical factors that influenced PROMs were implant
brand and hospital type (both p <
0.001). However, the effects
of surgical factors upon the PROMs were modest compared with patient
factors. For both the OKS and the EQ-5D the most important factors
influencing the improvement in PROMs were the corresponding pre-operative
score and the patient’s general health status. Despite having only
a small effect on PROMs, this study has shown that both implant
brand and hospital type do influence reported subjective functional
scores following
We investigated whether an asymmetric extension
gap seen on routine post-operative radiographs after primary total
knee replacement (TKR) is associated with pain at three, six, 12
and 24 months’ follow-up. On radiographs of 277 patients after primary
TKR we measured the distance between the tibial tray and the femoral
condyle on both the medial and lateral sides. A difference was defined
as an asymmetric extension gap. We considered three groups (no asymmetric
gap, medial-opening and lateral-opening gap) and calculated the
associations with the Western Ontario and McMaster Universities
osteoarthritis index pain scores over time. Those with an asymmetric extension gap of ≥ 1.5 mm had a significant
association with pain scores at three months’ follow-up; patients
with a medial-opening extension gap reported more pain and patients
with a lateral-opening extension gap reported less pain (p = 0.036).
This effect was still significant at six months (p = 0.044), but had
lost significance by 12 months (p = 0.924). When adjusting for multiple
cofounders the improvement in pain was more pronounced in patients
with a lateral-opening extension gap than in those with a medial-opening extension
gap at three (p = 0.037) and six months’ (p = 0.027) follow-up. Cite this article:
We reviewed the long-term clinical and radiological
results of 63 uncemented Low Contact Stress (LCS) total knee replacements
(TKRs) in 47 patients with rheumatoid arthritis. The mean age of
the patients at the time of surgery was 69 years (53 to 81). At
a mean follow-up of 22 years (20 to 25), 12 patients were alive
(17 TKRs), 27 had died (36 TKRs), and eight (ten TKRs) were lost
to follow-up. Revision was necessary in seven patients (seven TKRs, 11.1%)
at a mean of 12.1 years (0 to 19) after surgery. In the surviving
ten patients who had not undergone revision (15 TKRs), the mean
Oxford knee score was 30.2 (16 to 41) at a mean follow-up of 19.5
years (15 to 24.7) and mean active flexion was 105° (90° to 150°).
The survival rate was 88.9% at 20 years (56 of 63) and the Kaplan–Meier
survival estimate, without revision, was 80.2% (95% confidence interval
37 to 100) at 25 years. Cite this article:
In the absence of patellar resurfacing, we have
previously shown that the use of electrocautery around the margin of
the patella improved the one-year clinical outcome of total knee
replacement (TKR). In this prospective randomised study we compared
the mean 3.7 year (1.1 to 4.2) clinical outcomes of 300 TKRs performed
with and without electrocautery of the patellar rim: this is an
update of a previous report. The overall prevalence of anterior knee
pain was 32% (95% confidence intervals [CI] 26 to 39), and 26% (95%
CI 18 to 35) in the intervention group compared with 38% (95% CI
29 to 48) in the control group (chi-squared test; p = 0.06). The
overall prevalence of anterior knee pain remained unchanged between
the one-year and 3.7 year follow-up (chi-squared test; p = 0.12). The
mean total Western Ontario McMasters Universities Osteoarthritis
Indices and the American Knee Society knee and function scores at
3.7 years’ follow-up were similar in the intervention and control
groups (repeated measures analysis of variance p = 0.43, p = 0.09
and p = 0.59, respectively). There were no complications. A total
of ten patients (intervention group three, control group seven)
required secondary patellar resurfacing after the first year. Our study suggests that the improved clinical outcome with electrocautery
denervation compared with no electrocautery is not maintained at
a mean of 3.7 years’ follow-up. Cite this article:
Aims. The use of high tibial osteotomy (HTO) to delay
We investigated the characteristics of patients
who achieved Japanese-style deep flexion (seiza-sitting) after total knee
replacement (TKR) and measured three-dimensional positioning and
the contact positions of the femoral and tibial components. Seiza-sitting
was achieved after surgery by 23 patients (29 knees) of a series
of 463 TKRs in 341 patients. Pre-operatively most of these patients
were capable of seiza-sitting, had a lower body mass index and a favourable
attitude towards the Japanese lifestyle (27 of 29 knees). According
to two-/three-dimensional image registration analysis in the seiza-sitting
position, flexion, varus and internal rotation angles of the tibial
component relative to the femoral component had means of 148° ( Cite this article:
Aims. The primary objective of this study was to compare the five-year tibial component migration and wear between highly crosslinked polyethylene (HXLPE) inserts and conventional polyethylene (PE) inserts of the uncemented Triathlon fixed insert cruciate-retaining
Aims. The Coronal Plane Alignment of the Knee (CPAK) classification is a simple and comprehensive system for predicting pre-arthritic knee alignment. However, when the CPAK classification is applied in the Asian population, which is characterized by more varus and wider distribution in lower limb alignment, modifications in the boundaries of arithmetic hip-knee-ankle angle (aHKA) and joint line obliquity (JLO) should be considered. The purposes of this study were as follows: first, to propose a modified CPAK classification based on the actual joint line obliquity (aJLO) and wider range of aHKA in the Asian population; second, to test this classification in a cohort of Asians with healthy knees; third, to propose individualized alignment targets for different CPAK types in kinematically aligned (KA)
Aims. The aim of this study was to report patient and clinical outcomes following robotic-assisted
Aims. Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but the feasibility and early outcomes when using this technology for revision surgery remain unknown. The objective of this study was to compare the outcomes of robotic arm-assisted revision of unicompartmental knee arthroplasty (UKA) to
Aims. The primary aim of this study was to compare the postoperative systemic inflammatory response in conventional jig-based
Aims. Distal femoral osteotomies (DFOs) are commonly used for the correction of valgus deformities and lateral compartment osteoarthritis. However, the impact of a DFO on subsequent
Aims. Nearly 99,000
Aims. The purpose of this study is to determine an individual’s age-specific prevalence of
Aims. The rate of day-case
Aims. The aims were to assess whether joint-specific outcome after
Aims. Unicompartmental knee arthroplasty (UKA) and
Advanced 3D imaging and CT-based navigation have emerged as valuable tools to use in
Aims. Robotic-assisted
We aim to evaluate the usefulness of postoperative blood tests by investigating the incidence of abnormal results following total joint replacement (TJR), as well as identifying preoperative risk factors for abnormal blood test results postoperatively, especially pertaining to anaemia and acute kidney injury (AKI). This is a retrospective cohort study of patients who had elective TJR between January and December 2019 at a tertiary centre. Data gathered included age at time of surgery, sex, BMI, American Society of Anesthesiologists (ASA) grade, preoperative and postoperative laboratory test results, haemoglobin (Hgb), white blood count (WBC), haematocrit (Hct), platelets (Plts), sodium (Na+), potassium (K+), creatinine (Cr), estimated glomerular filtration rate (eGFR), and Ferritin (ug/l). Abnormal blood tests, AKI, electrolyte imbalance, anaemia, transfusion, reoperation, and readmission within one year were reported.Aims
Methods
Aims. Breast cancer survivors have known risk factors that might influence the results of total hip arthroplasty (THA) or
Aims.
Aims. Blood transfusion and postoperative anaemia are complications of
Aims. This study aims to determine the rate of and risk factors for
Aims. To assess the cost-effectiveness of a two-layer compression bandage versus a standard wool and crepe bandage following
Aims.
Aims. The mid-term results of kinematic alignment (KA) for
Aims. In-hospital length of stay (LOS) and discharge dispositions following arthroplasty could act as surrogate measures for improvement in patient pathways, and have major cost saving implications for healthcare providers. With the ever-growing adoption of robotic technology in arthroplasty, it is imperative to evaluate its impact on LOS. The objectives of this study were to compare LOS and discharge dispositions following robotic arm-assisted
Aims. Mid-level constraint designs for
Aims. No predictive model has been published to forecast operating time for
Prophylactic antibiotics are important in reducing the risk of periprosthetic joint infection (PJI) following
Aims. The aims of this study were to investigate the ability to kneel after
Aims. This multicentre retrospective observational study’s aims were to investigate whether there are differences in the occurrence of radiolucent lines (RLLs) following
Aims. This prospective study reports longitudinal, within-patient, patient-reported outcome measures (PROMs) over a 15-year period following cemented single radius
Aims. The primary aim was to assess whether robotic
Aims. The aim of this study was to compare a bicruciate-retaining (BCR)
Aims. Despite new technologies for
Aims. Waiting times for arthroplasty surgery in Northern Ireland are among the longest in the NHS, which have been further lengthened by the onset of the COVID-19 global pandemic in March 2020. The Department of Health in Northern Ireland has announced a new Elective Care Framework (ECF), with the framework proposing that by March 2026 no patient will wait more than 52 weeks for inpatient/day case treatment. We aimed to assess the feasibility of achieving this with reference to total hip arthroplasty (THA) and
Aims. The aim of this study was to compare ten-year longitudinal healthcare costs and revision rates for patients undergoing unicompartmental knee arthroplasty (UKA) and
Aims. Access to
Aims. The success of
Aims. We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measurement of knee range of motion after
Aims. The aim was to assess whether robotic-assisted
Aims. Neither a surgeon’s intraoperative impression nor the parameters of computer navigation have been shown to be predictive of the outcomes following
Aims. This study aimed to evaluate if
Limb alignment in
Aims. Social determinants of health (SDOHs) may contribute to the total cost of care (TCOC) for patients undergoing
Aims. The aim of this study was to investigate the distribution of phenotypes in Asian patients with end-stage osteoarthritis (OA) and assess whether the phenotype affected the clinical outcome and survival of mechanically aligned
Aims. Intraoperative pressure sensors allow surgeons to quantify soft-tissue balance during
Aims. There is conflicting evidence on the safety of intra-articular injections of hyaluronic acid (HA) or corticosteroids (CSs) before
Aims. The goal of the current systematic review was to assess the impact of implant placement accuracy on outcomes following
Aims. Unicompartmental knee arthroplasty (UKA) and bicompartmental knee arthroplasty (BCA) have been associated with improved functional outcomes compared to
Aims. This study aimed to investigate the optimal sagittal positioning of the uncemented femoral component in
Aims. The aim of this study was to compare any differences in the primary outcome (biphasic flexion knee moment during gait) of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned
Aims. The primary aim of this study was to compare the migration of the femoral and tibial components of the cementless rotating platform Attune and Low Contact Stress (LCS)
Aims. Many surgeons choose to perform
Aims. Patients with a deformity of the hindfoot present a particular challenge when performing
The aim of this study is to compare the effectiveness and safety of thromboprophylactic treatments in patients undergoing primary total knee arthroplasty (TKA). Using nationwide medical registries, we identified patients with a primary TKA performed in Denmark between 1 January 2013 and 31 December 2018 who received thromboprophylactic treatment. We examined the 90-day risk of venous thromboembolism (VTE), major bleeding, and all-cause mortality following surgery. We used a Cox regression model to compute hazard ratios (HRs) with 95% confidence intervals (CIs) for each outcome, pairwise comparing treatment with dalteparin or dabigatran with rivaroxaban as the reference. The HRs were both computed using a multivariable and a propensity score matched analysis.Aims
Methods
Aims. The surgical target for optimal implant positioning in robotic-assisted
Aims. Medial pivot (MP)
Aims. The primary aim of this study was to assess whether non-fatal postoperative venous thromboembolism (VTE) within six months of surgery influences the knee-specific functional outcome (Oxford Knee Score (OKS)) one year after
Objectives. Electronic forms of data collection have gained interest in recent
years. In orthopaedics, little is known about patient preference
regarding pen-and-paper or electronic questionnaires. We aimed to
determine whether patients undergoing total hip (THR) or total knee
replacement (TKR) prefer pen-and-paper or electronic questionnaires
and to identify variables that predict preference for electronic
questionnaires. Methods. We asked patients who participated in a multi-centre cohort study
investigating improvement in health-related quality of life (HRQoL)
after THR and
Aims. Wear of the polyethylene (PE) tibial insert of
Aims. A novel enhanced cement fixation (EF) tibial implant with deeper cement pockets and a more roughened bonding surface was released to market for an existing
Aims. It is unknown whether gap laxities measured in robotic arm-assisted
Objectives. To define Patient Acceptable Symptom State (PASS) thresholds
for the Oxford hip score (OHS) and Oxford knee score (OKS) at mid-term
follow-up. Methods. In a prospective multicentre cohort study, OHS and OKS were collected
at a mean follow-up of three years (1.5 to 6.0), combined with a
numeric rating scale (NRS) for satisfaction and an external validation
question assessing the patient’s willingness to undergo surgery
again. A total of 550 patients underwent total hip replacement (THR)
and 367 underwent
Aims. Recent
Aims. The Coronal Plane Alignment of the Knee (CPAK) classification has been developed to predict individual variations in inherent knee alignment. The impact of preoperative and postoperative CPAK classification phenotype on the postoperative clinical outcomes of
Pre-operative variables are increasingly being
used to determine eligibility for
Aims. The tibial component of
The aim of this study was to perform a cost–utility
analysis of total hip (THR) and knee replacement (TKR). Arthritis is
a disabling condition that leads to long-term deterioration in quality
of life. Total joint replacement, despite being one of the greatest
advances in medicine of the modern era, has recently come under
scrutiny. The National Health Service (NHS) has competing demands,
and resource allocation is challenging in times of economic restraint. Patients
who underwent THR (n = 348) or
Aims.
Patient expectations and their fulfilment are
an important factor in determining patient-reported outcome and satisfaction
of hip (THR) and knee replacement (TKR). The aim of this prospective
cohort study was to examine the expectations of patients undergoing
THR and