Advertisement for orthosearch.org.uk
Results 1 - 50 of 418
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1225 - 1233
1 Nov 2022
Png ME Petrou S Achten J Ooms A Lamb SE Hedley H Dias J Costa ML

Aims. The aim of this study was to compare the cost-effectiveness of surgical fixation with Kirschner (K-)wire ersus moulded casting after manipulation of a fracture of the distal radius in an operating theatre setting. Methods. An economic evaluation was conducted based on data collected from the Distal Radius Acute Fracture Fixation Trial 2 (DRAFFT2) multicentre randomized controlled trial in the UK. Resource use was collected at three, six, and 12 months post-randomization using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY) gained from an NHS and personal social services perspective. Sensitivity analyses were conducted to examine the robustness of cost-effectiveness estimates, and decision uncertainty was handled using confidence ellipses and cost-effectiveness acceptability curves. Results. In the base case analysis, surgical fixation with K-wire was more expensive (£29.65 (95% confidence interval (CI) -94.85 to 154.15)) and generated lower QALYs (0.007 (95% CI -0.03 to 0.016)) than moulded casting, but this difference was not statistically significant. The probability of K-wire being cost-effective at a £20,000 per QALY cost-effectiveness threshold was 24%. The cost-effectiveness results remained robust in the sensitivity analyses. Conclusion. The findings suggest that surgical fixation with K-wire is unlikely to be a cost-effective alternative to a moulded cast in adults, following manipulation of a fracture of the distal radius in a theatre setting. Cite this article: Bone Joint J 2022;104-B(11):1225–1233


Aims. The aim of this study was to compare the clinical effectiveness of Kirschner wire (K-wire) fixation with locking-plate fixation for patients with a dorsally displaced fracture of the distal radius in the five years after injury. Patients and Methods. We report the five-year follow-up of a multicentre, two-arm, parallel-group randomized controlled trial. A total of 461 adults with a dorsally displaced fracture of the distal radius within 3 cm of the radiocarpal joint that required surgical fixation were recruited from 18 trauma centres in the United Kingdom. Patients were excluded if the surface of the wrist joint was so badly displaced it required open reduction. In all, 448 patients were randomized to receive either K-wire fixation or locking-plate fixation. In the K-wire group, there were 179 female and 38 male patients with a mean age of 59.1 years (19 to 89). In the locking-plate group, there were 194 female and 37 male patients with a mean age of 58.3 years (20 to 89). The primary outcome measure was the patient-rated wrist evaluation (PRWE). Secondary outcomes were health-related quality of life using the EuroQol five-dimension three-level (EQ-5D-3L) assessment, and further surgery related to the index fracture. Results. At 12 months, 402/448 participants (90%) recruited into the main study provided PRWE scores. At year two, 294 participants (66%) provided scores; at year five, 198 participants (44%) provided scores. There was no clinically relevant difference in the PRWE at any point during the five-year follow-up; at five years, the PRWE score was 8.3 (12.5) in the wire group and 11.3 (15.6) in the plate group (95% confidence interval -6.99 to 0.99; p = 0.139). Nor was there a clinically relevant difference in health-related quality of life. Only three participants had further surgery in the five years after their injury (one in the wire group and two in the plate group). Conclusion. This follow-up study continues to show no evidence of a difference in wrist pain, wrist function, or quality of life for patients treated with wires versus locking plates in the five years following a dorsally displaced fracture of the distal radius. Cite this article: Bone Joint J 2019;101-B:978–983


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1263 - 1271
1 Oct 2019
Eisenschenk A Spitzmüller R Güthoff C Obladen A Kim S Henning E Dornberger JE Stengel D

Aims. The aim of this study was to investigate whether clinical and radiological outcomes after intramedullary nailing of displaced fractures of the fifth metacarpal neck using a single thick Kirschner wire (K-wire) are noninferior to those of technically more demanding fixation with two thinner dual wires. Patients and Methods. This was a multicentre, parallel group, randomized controlled noninferiority trial conducted at 12 tertiary trauma centres in Germany. A total of 290 patients with acute displaced fractures of the fifth metacarpal neck were randomized to either intramedullary single-wire (n = 146) or dual-wire fixation (n = 144). The primary outcome was the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire six months after surgery, with a third of the minimal clinically important difference (MCID) used as the noninferiority threshold. Secondary outcomes were pain, health-related quality of life (EuroQol five-dimensional questionnaire (EQ-5D)), radiological measures, functional deficits, and complications. Results. Overall, 151/290 of patients (52%) completed the six months of follow-up, leaving 83 patients in the single-wire group and 68 patients in the dual-wire group. In the modified intention-to-treat analysis set, mean DASH scores six months after surgery were 3.8 (. sd. 7.0) and 4.4 (. sd. 9.4), respectively. With multiple imputation (n = 288), mean DASH scores were estimated at 6.3 (. sd. 8.7) and 7.0 (. sd. 10.0). Upper (1 - 2α)) confidence limits consistently remained below the noninferiority margin of 3.0 points in the DASH instrument. While there was a statistically nonsignificant trend towards a higher rate of shortening and rotational malalignment in the single wire group, no statistically significant differences were observed across groups in any secondary outcome measure. Conclusion. A single thick K-wire is sufficient for intramedullary fixation of acute displaced subcapital fractures of the fifth metacarpal neck. The less technically demanding single-wire technique produces noninferior clinical and radiological outcomes compared with the dual-wire approach. Cite this article: Bone Joint J 2019;101-B:1263–1271


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1082 - 1089
1 Aug 2015
Tubeuf S Yu G Achten J Parsons NR Rangan A Lamb SE Costa ML

We present an economic evaluation using data from the Distal Radius Acute Fracture Fixation Trial (DRAFFT) to compare the relative cost effectiveness of percutaneous Kirschner wire (K-wire) fixation and volar locking-plate fixation for patients with dorsally-displaced fractures of the distal radius. . The cost effectiveness analysis (cost per quality-adjusted life year; QALY) was derived from a multi-centre, two-arm, parallel group, assessor-blind, randomised controlled trial which took place in 18 trauma centres in the United Kingdom. Data from 460 patients were available for analysis, which includes both a National Health Service cost perspective including costs of surgery, implants and healthcare resource use over a 12-month period after surgery, and a societal perspective, which includes the cost of time off work and the need for additional private care. . There was only a small difference in QALYs gained for patients treated with locking-plate fixation over those treated with K-wires. At a mean additional cost of £714 (95% confidence interval 588 to 865) per patient, locking-plate fixation presented an incremental cost effectiveness ratio (ICER) of £89 322 per QALY within the first 12 months of treatment. Sensitivity analyses were undertaken to assess the ICER of locking-plate fixation compared with K-wires. These were greater than £30 000. . Compared with locking-plate fixation, K-wire fixation is a ‘cost saving’ intervention, with similar health benefits. Cite this article: Bone Joint J 2015;97-B:1082–9


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 106 - 108
1 Jan 1998
Ngarmukos C Parkpian V Patradul A

We treated 110 fractures of the middle third of the clavicle in 108 patients aged between 14 and 66 years, by fixation with 2 mm Kirschner wires. The wire was introduced, using an air drill and a telescoping guide, from the medial into the lateral fragment. The medial end of the wire which perforated the anterior cortex of the medial fragment was bent backwards to prevent migration into the lung or mediastinum. In cases of nonunion and acute fracture in which a bone gap was present, bone graft was laid around the fracture site after internal fixation. All the fractures united. No wires broke but in three patients one migrated before union was achieved. Twenty-one patients failed to return for removal of the wire; nine of them had radiological evidence of union before they were lost to follow-up


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 858 - 861
1 Nov 1992
Casteleyn P Handelberg F Haentjens P

In a prospective trial, biodegradable polyglycolic acid rods were compared with Kirschner wires for fixation of wrist fractures (Frykman types I, II, V and VI). Fifteen patients were randomly assigned to each treatment group. There was no significant difference between the groups with regard to age, sex ratio and fracture type. Kapandji's pinning technique was used in all cases. There were no significant differences in the results obtained in both groups at final follow-up. At three months and six months the functional results of the Kirschner-wire group were, however, significantly better (p < 0.05), due to numerous transient complications from foreign-body reactions to the polyglycolic acid rods. The use of polyglycolic acid rods is therefore not recommended for the fixation of distal radial fractures


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 809 - 814
1 Jun 2013
Park HY Yoon JO Jeon IH Chung HW Kim JS

This study was performed to determine whether pure cancellous bone graft and Kirschner (K-) wire fixation were sufficient to achieve bony union and restore alignment in scaphoid nonunion. A total of 65 patients who underwent cancellous bone graft and K-wire fixation were included in this study. The series included 61 men and four women with a mean age of 34 years (15 to 72) and mean delay to surgery of 28.7 months (3 to 240). The patients were divided into an unstable group (A) and stable group (B) depending on the pre-operative radiographs. Unstable nonunion was defined as a lateral intrascaphoid angle > 45°, or a radiolunate angle > 10°. There were 34 cases in group A and 31 cases in group B. Bony union was achieved in 30 patients (88.2%) in group A, and in 26 (83.9%) in group B (p = 0.439). Comparison of the post-operative radiographs between the two groups showed no significant differences in lateral intrascaphoid angle (p = 0.657) and scaphoid length (p = 0.670) and height (p = 0.193). The radiolunate angle was significantly different (p = 0.020) but the mean value in both groups was < 10°. Comparison of the dorsiflexion and palmar flexion of movement of the wrist and the mean Mayo wrist score at the final clinical visit in each group showed no significant difference (p = 0.190, p = 0.587 and p = 0.265, respectively). Cancellous bone graft and K-wire fixation were effective in the treatment of stable and unstable scaphoid nonunion. Cite this article: Bone Joint J 2013;95-B:809–14


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 292 - 296
1 Mar 1992
Plaga B Royster R Donigian A Wright G Caskey P

We compared fibrin sealant, polydioxanone (PDS) pins and Kirschner wires in the fixation of osteochondral fractures in rabbit knees. Standardised osteochondral fractures of the right medial femoral condyle were made in 56 adult New Zealand white rabbits. There were equal groups of control knees, and those which had Kirschner-wire, fibrin-sealant or PDS-pin fixation. No external immobilisation was used. One animal from each group was killed at two, three and four weeks. The remaining rabbits were killed at six weeks. A fracture which healed with less than 1 mm of displacement was considered a success. There was successful healing in 29% of the control group, in all of the Kirschner-wire group, in 50% of the fibrin-sealant group, and in 86% of the PDS-pin group. The use of PDS pins appears to be a reliable alternative to the use of metal in the fixation of osteochondral fractures in rabbits


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 902 - 907
1 May 2021
Marson BA Ng JWG Craxford S Chell J Lawniczak D Price KR Ollivere BJ Hunter JB

Aims

The management of completely displaced fractures of the distal radius in children remains controversial. This study evaluates the outcomes of surgical and non-surgical management of ‘off-ended’ fractures in children with at least two years of potential growth remaining.

Methods

A total of 34 boys and 22 girls aged 0 to ten years with a closed, completely displaced metaphyseal distal radial fracture presented between 1 November 2015 and 1 January 2020. After 2018, children aged ten or under were offered treatment in a straight plaster or manipulation under anaesthesia with Kirschner (K-)wire stabilization. Case notes and radiographs were reviewed to evaluate outcomes. In all, 16 underwent treatment in a straight cast and 40 had manipulation under anaesthesia, including 37 stabilized with K-wires.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1478 - 1481
1 Nov 2009
Lee YH Kim JY Chung MS Baek GH Gong HS Lee SK

We treated 32 displaced mallet finger fractures by a two extension block Kirschner-wire technique. The clinical and radiological outcomes were evaluated at a mean follow-up of 49 months (25 to 84). The mean joint surface involvement was 38.4% (33% to 50%) and 18 patients (56%) had accompanying joint subluxation.

All 32 fractures united with a mean time to union of 6.2 weeks (5.1 to 8.2). Congruent joint surfaces and anatomical reduction were seen in all cases. The mean flexion of the distal interphalangeal joints was 83.1° (75° to 90°) and the mean extension loss was 0.9° (0° to 7°). No digit had a prominent dorsal bump or a recurrent mallet deformity.

We believe that this technique, when properly applied, produces satisfactory results both clinically and radiologically.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 746 - 746
1 Jul 1998
HOPKINSON-WOOLLEY JA CONSTANT CR


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 326 - 327
1 Mar 1988
Potter F Fiorini A Knox J Rajesh P


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 82 - 87
1 Jan 2023
Barrie A Kent B

Aims. Management of displaced paediatric supracondylar elbow fractures remains widely debated and actual practice is unclear. This national trainee collaboration aimed to evaluate surgical and postoperative management of these injuries across the UK. Methods. This study was led by the South West Orthopaedic Research Division (SWORD) and performed by the Supra Man Collaborative. Displaced paediatric supracondylar elbow fractures undergoing surgery between 1 January 2019 and 31 December 2019 were retrospectively identified and their anonymized data were collected via Research Electronic Data Capture (REDCap). Results. A total of 972 patients were identified across 41 hospitals. Mean age at injury was 6.3 years (1 to 15), 504 were male (52%), 583 involved the left side (60%), and 538 were Gartland type 3 fractures (55%). Median time from injury to theatre was 16 hours (interquartile range (IQR) 6.6 to 22), 300 patients (31%) underwent surgery on the day of injury, and 91 (9%) underwent surgery between 10:00 pm and 8:00 am. Overall, 910 patients (94%) had Kirschner (K)-wire) fixation and these were left percutaneous in 869 (95%), while 62 patients (6%) had manipulation under anaesthetic (MUA) and casting. Crossed K-wire configuration was used as fixation in 544 cases (59.5%). Overall, 208 of the fixation cases (61%) performed or supervised by a paediatric orthopaedic consultant underwent lateral-only fixation, whereas 153 (27%) of the fixation cases performed or supervised by a non-paediatric orthopaedic consultant used lateral-only fixation. In total, 129 percutaneous wires (16%) were removed in theatre. Of the 341 percutaneous wire fixations performed or supervised by a paediatric orthopaedic consultant, 11 (3%) underwent wire removal in theatre, whereas 118 (22%) of the 528 percutaneous wire fixation cases performed or supervised by a non-paediatric orthopaedic consultant underwent wire removal in theatre. Four MUA patients (6%) and seven K-wire fixation patients (0.8%) required revision surgery within 30 days for displacement. Conclusion. The treatment of supracondylar elbow fractures in children varies across the UK. Patient cases where a paediatric orthopaedic consultant was involved had an increased tendency for lateral only K-wire fixation and for wire removal in clinic. Low rates of displacement requiring revision surgery were identified in all fixation configurations. Cite this article: Bone Joint J 2023;105-B(1):82–87


Bone & Joint Research
Vol. 13, Issue 8 | Pages 383 - 391
2 Aug 2024
Mannala GK Rupp M Walter N Youf R Bärtl S Riool M Alt V

Aims. Bacteriophages infect, replicate inside bacteria, and are released from the host through lysis. Here, we evaluate the effects of repetitive doses of the Staphylococcus aureus phage 191219 and gentamicin against haematogenous and early-stage biofilm implant-related infections in Galleria mellonella. Methods. For the haematogenous infection, G. mellonella larvae were implanted with a Kirschner wire (K-wire), infected with S. aureus, and subsequently phages and/or gentamicin were administered. For the early-stage biofilm implant infection, the K-wires were pre-incubated with S. aureus suspension before implantation. After 24 hours, the larvae received phages and/or gentamicin. In both models, the larvae also received daily doses of phages and/or gentamicin for up to five days. The effect was determined by survival analysis for five days and quantitative culture of bacteria after two days of repetitive doses. Results. In the haematogenous infection, a single combined dose of phages and gentamicin, and repetitive injections with gentamicin or in combination with phages, resulted in significantly improved survival rates. In the early-stage biofilm infection, only repetitive combined administration of phages and gentamicin led to a significantly increased survival. Additionally, a significant reduction in number of bacteria was observed in the larvae after receiving repetitive doses of phages and/or gentamicin in both infection models. Conclusion. Based on our results, a single dose of the combination of phages and gentamicin is sufficient to prevent a haematogenous S. aureus implant-related infection, whereas gentamicin needs to be administered daily for the same effect. To treat early-stage S. aureus implant-related infection, repetitive doses of the combination of phages and gentamicin are required. Cite this article: Bone Joint Res 2024;13(8):383–391


Aims. The primary aim of this study was to report the radiological outcomes of patients with a dorsally displaced distal radius fracture who were randomized to a moulded cast or surgical fixation with wires following manipulation and closed reduction of their fracture. The secondary aim was to correlate radiological outcomes with patient-reported outcome measures (PROMs) in the year following injury. Methods. Participants were recruited as part of DRAFFT2, a UK multicentre clinical trial. Participants were aged 16 years or over with a dorsally displaced distal radius fracture, and were eligible for the trial if they needed a manipulation of their fracture, as recommended by their treating surgeon. Participants were randomly allocated on a 1:1 ratio to moulded cast or Kirschner wires after manipulation of the fracture in the operating theatre. Standard posteroanterior and lateral radiographs were performed in the radiology department of participating centres at the time of the patient’s initial assessment in the emergency department and six weeks postoperatively. Intraoperative fluoroscopic images taken at the time of fracture reduction were also assessed. Results. Patients treated with surgical fixation with wires had less dorsal angulation of the radius versus those treated in a moulded cast at six weeks after manipulation of the fracture; the mean difference of -4.13° was statistically significant (95% confidence interval 5.82 to -2.45). There was no evidence of a difference in radial shortening. However, there was no correlation between these radiological measurements and PROMs at any timepoint in the 12 months post-injury. Conclusion. For patients with a dorsally displaced distal radius fracture treated with a closed manipulation, surgical fixation with wires leads to less dorsal angulation on radiographs at six weeks compared with patients treated in a moulded plaster cast alone. However, the difference in dorsal angulation was small and did not correlate with patient-reported pain and function. Cite this article: Bone Jt Open 2024;5(2):132–138


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 946 - 952
1 Aug 2022
Wu F Zhang Y Liu B

Aims. This study aims to report the outcomes in the treatment of unstable proximal third scaphoid nonunions with arthroscopic curettage, non-vascularized bone grafting, and percutaneous fixation. Methods. This was a retrospective analysis of 20 patients. All cases were delayed presentations (n = 15) or failed nonoperatively managed scaphoid fractures (n = 5). Surgery was performed at a mean duration of 27 months (7 to 120) following injury with arthroscopic debridement and arthroscopic iliac crest autograft. Fracture fixation was performed percutaneously with Kirschner (K)-wires in 12 wrists, a headless screw in six, and a combination of a headless screw and single K-wire in two. Clinical outcomes were assessed using grip strength, patient-reported outcome measures, and wrist range of motion (ROM) measurements. Results. Intraoperatively, established avascular necrosis of the proximal fragment was identified in ten scaphoids. All fractures united within 16 weeks, confirmed by CT. At a mean follow-up of 31 months (12 to 64), there were significant improvements in the Patient-Rated Wrist Evaluation, Mayo Wrist Score, abbreviated Disabilities of the Arm, Shoulder and Hand score, wrist ROM, grip strength, and the patients’ subjective pain score. No peri- or postoperative complications were encountered. Conclusion. Our data indicate that arthroscopic bone grafting and fixation with cancellous autograft is a viable method in the treatment of proximal third scaphoid nonunions, regardless of the vascularity of the proximal fragment. Cite this article: Bone Joint J 2022;104-B(8):946–952


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1550 - 1556
1 Dec 2019
Mc Colgan R Dalton DM Cassar-Gheiti AJ Fox CM O’Sullivan ME

Aims. The aim of this study was to examine trends in the management of fractures of the distal radius in Ireland over a ten-year period, and to determine if there were any changes in response to the English Distal Radius Acute Fracture Fixation Trial (DRAFFT). Patients and Methods. Data was grouped into annual intervals from 2008 to 2017. All adult inpatient episodes that involved emergency surgery for fractures of the distal radius were included. Results. In 2008 Kirschner-wire (K-wire) fixation accounted for 59% of operations for fractures of the distal radius, and plate fixation for 21%. In 2017, the rate of K-wire fixation had fallen to 30%, and the proportion of patients who underwent plate fixation had risen to 62%. Conclusion. There is an increasing trend towards open reduction and internal fixation for fractures of the distal radius in Ireland. This has been accompanied by a decrease in popularity for K-wire fixation. DRAFFT did not appear to influence trends in the management of fractures of the distal radius in Ireland. Cite this article: Bone Joint J 2019;101-B:1550–1556


Bone & Joint Research
Vol. 11, Issue 2 | Pages 49 - 60
1 Feb 2022
Li J Wong RMY Chung YL Leung SSY Chow SK Ip M Cheung W

Aims. With the ageing population, fragility fractures have become one of the most common conditions. The objective of this study was to investigate whether microbiological outcomes and fracture-healing in osteoporotic bone is worse than normal bone with fracture-related infection (FRI). Methods. A total of 120 six-month-old Sprague-Dawley (SD) rats were randomized to six groups: Sham, sham + infection (Sham-Inf), sham with infection + antibiotics (Sham-Inf-A), ovariectomized (OVX), OVX + infection (OVX-Inf), and OVX + infection + antibiotics (OVX-Inf-A). Open femoral diaphysis fractures with Kirschner wire fixation were performed. Staphylococcus aureus at 4 × 10. 4. colony-forming units (CFU)/ml was inoculated. Rats were euthanized at four and eight weeks post-surgery. Radiography, micro-CT, haematoxylin-eosin, mechanical testing, immunohistochemistry (IHC), gram staining, agar plating, crystal violet staining, and scanning electron microscopy were performed. Results. Agar plating analysis revealed a higher bacterial load in bone (p = 0.002), and gram staining showed higher cortical bone colonization (p = 0.039) in OVX-Inf compared to Sham-Inf. OVX-Inf showed significantly increased callus area (p = 0.013), but decreased high-density bone volume (p = 0.023) compared to Sham-Inf. IHC staining showed a significantly increased expression of TNF-α in OVX-Inf compared to OVX (p = 0.049). Significantly reduced bacterial load on bone (p = 0.001), enhanced ultimate load (p = 0.001), and energy to failure were observed in Sham-Inf-A compared to Sham-Inf (p = 0.028), but not in OVX-Inf-A compared to OVX-Inf. Conclusion. In osteoporotic bone with FRI, infection was more severe with more bone lysis and higher bacterial load, and fracture-healing was further delayed. Systemic antibiotics significantly reduced bacterial load and enhanced callus quality and strength in normal bone with FRI, but not in osteoporotic bone. Cite this article: Bone Joint Res 2022;11(2):49–60


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 387 - 395
1 Mar 2018
Ganeshalingam R Donnan A Evans O Hoq M Camp M Donnan L

Aims. Displaced fractures of the lateral condyle of the humerus are frequently managed surgically with the aim of avoiding nonunion, malunion, disturbances of growth and later arthritis. The ideal method of fixation is however not known, and treatment varies between surgeons and hospitals. The aim of this study was to compare the outcome of two well-established forms of surgical treatment, Kirschner wire (K-wire) and screw fixation. Patients and Methods. A retrospective cohort study of children who underwent surgical treatment for a fracture of the lateral condyle of the humerus between January 2005 and December 2014 at two centres was undertaken. Pre, intraoperative and postoperative characteristics were evaluated. A total of 336 children were included in the study. Their mean age at the time of injury was 5.8 years (0 to 15) with a male:female patient ratio of 3:2. A total of 243 (72%) had a Milch II fracture and the fracture was displaced by > 2 mm in 228 (68%). In all, 235 patients underwent K-wire fixation and 101 had screw fixation. . Results. There was a higher rate of nonunion with K-wire fixation (p = 0.02). There was no difference in Baumann’s angle, carrying angle or the rate of major complications between the two groups. No benefit was obtained by immobilizing the elbow for more than four weeks in either group. No short-term complications were seen when fixation crossed the lateral ossific nucleus. Conclusions. Fixation of lateral condylar humeral fractures in children using either K-wires or screws gives satisfactory results. Proponents of both techniques may find justification of their methods in our data, but prospective, randomized trials with long-term follow-up are required to confirm the findings, which suggest a higher rate of nonunion with K-wire fixation. Cite this article: Bone Joint J 2018;100-B:387–95


Bone & Joint Open
Vol. 1, Issue 7 | Pages 424 - 430
17 Jul 2020
Baxter I Hancock G Clark M Hampton M Fishlock A Widnall J Flowers M Evans O

Aims. To determine the impact of COVID-19 on orthopaediatric admissions and fracture clinics within a regional integrated care system (ICS). Methods. A retrospective review was performed for all paediatric orthopaedic patients admitted across the region during the recent lockdown period (24 March 2020 to 10 May 2020) and the same period in 2019. Age, sex, mechanism, anatomical region, and treatment modality were compared, as were fracture clinic attendances within the receiving regional major trauma centre (MTC) between the two periods. Results. Paediatric trauma admissions across the region fell by 33% (197 vs 132) with a proportional increase to 59% (n = 78) of admissions to the MTC during lockdown compared with 28.4% in 2019 (N = 56). There was a reduction in manipulation under anaesthetic (p = 0.015) and the use of Kirschner wires (K-wires) (p = 0.040) between the two time periods. The median time to surgery remained one day in both (2019 IQR 0 to 2; 2020 IQR 1 to 1). Supracondylar fractures were the most common reason for fracture clinic attendance (17.3%, n = 19) with a proportional increase of 108.4% vs 2019 (2019 n = 20; 2020 n = 19) (p = 0.007). While upper limb injuries and falls from play apparatus, equipment, or height remained the most common indications for admission, there was a reduction in sports injuries (p < 0.001) but an increase in lacerations (p = 0.031). Fracture clinic management changed with 67% (n = 40) of follow-up appointments via telephone and 69% (n = 65) of patients requiring cast immobilization treated with a 3M Soft Cast, enabling self-removal. The safeguarding team saw a 22% reduction in referrals (2019: n = 41, 2020: n = 32). Conclusion. During this viral pandemic, the number of trauma cases decreased with a change in the mechanism of injury, median age of presentation, and an increase in referrals to the regional MTC. Adaptions in standard practice led to fewer MUA, and K-wire procedures being performed, more supracondylar fractures managed through clinic and an increase in the use of removable cast. Cite this article: Bone Joint Open 2020;1-7:424–430


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 939 - 945
1 May 2021
Kakar S Logli AL Ramazanian T Gaston RG Fowler JR

Aims. The purpose was to evaluate early clinical, patient-reported, and radiological outcomes of the scapholunate ligament 360° tenodesis (SL 360) technique for treatment of scapholunate (SL) instability. Methods. We studied the results of nine patients (eight males and one female with a mean age of 44.7 years (26 to 55)) who underwent the SL 360 procedure for reducible SL instability between January 2016 and June 2019, and who were identified from retrospective review of electronic medical records. Final follow-up of any kind was a mean of 33.7 months (12.0 to 51.3). Clinical, radiological, and patient-reported outcome data included visual analogue scale (VAS) for pain, Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH), Mayo Wrist Score (MWS), and Patient-Rated Wrist Examination (PRWE). Means were analyzed using paired t-test. Results. Before surgery, patients with SL instability were significantly impaired with respect to wrist flexion, extension, and grip strength (mean flexion, 51° (20° to 85°) vs 73° (45° to 90°); mean extension, 46° (15° to 70°) vs 66° (45° to 80°); mean grip strength, 25 kg (20 to 31) vs 50 kg (35 to 68) compared to the unaffected side). The mean SL gap (4.9 mm (2.3 to 7.3) vs 2.1 mm (1.6 to 2.9)) and mean SL angle (71° (59° to 105°) vs 50° (38° to 64°) were also significantly greater in the affected wrist. At final follow-up, there was mean improvement regarding clinical, radiological, and functional outcomes comparing preoperative to final postoperative values for the VAS for pain scale, QuickDASH, MWS, PRWE, and SL gap and SL angle. Conclusion. In our small series, the SL 360 procedure for reducible SL instability has favourable early clinical, patient-reported, and radiological outcomes at a mean of 33.7 months (12.0 to 51.3). The suture tape and tendon construct confers robust stability, permitting earlier mobilization without the inherent disadvantages of Kirschner wire stabilization. Cite this article: Bone Joint J 2021;103-B(5):939–945


Bone & Joint Research
Vol. 9, Issue 2 | Pages 71 - 76
1 Feb 2020
Gao T Lin J Zhang C Zhu H Zheng X

Aims. The purpose of this study was to determine whether intracellular Staphylococcus aureus is associated with recurrent infection in a rat model of open fracture. Methods. After stabilizing with Kirschner wire, we created a midshaft femur fracture in Sprague-Dawley rats and infected the wound with green fluorescent protein (GFP)-tagged S. aureus. After repeated debridement and negative swab culture was achieved, the isolation of GFP-containing cells from skin, bone marrow, and muscle was then performed. The composition and viability of intracellular S. aureus in isolated GFP-positive cells was assessed. We suppressed the host immune system and observed whether recurrent infection would occur. Finally, rats were assigned to one of six treatment groups (a combination of antibiotic treatment and implant removal/retention). The proportion of successful eradication was determined. Results. Green fluorescent protein-containing cells were successfully isolated after the swab culture was negative from skin (n = 0, 0%), muscle (n = 10, 100%), and bone marrow (n = 10, 100%) of a total of ten rats. The phagocytes were predominant in GFP-positive cells from muscle (73%) and bone marrow (81%) with a significantly higher viability of intracellular S. aureus (all p-values < 0.001). The recurrent infection occurred in up to 75% of rats after the immunosuppression. The proportion of successful eradication was not associated with implant retention or removal, and the efficacy of linezolid in eradicating intracellular S. aureus is significantly higher than that of vancomycin. Conclusion. Intracellular S. aureus is associated with recurrent infection in the rat model of open fracture. Usage of linezolid, a membrane-permeable antibiotic, is an effective strategy against intracellular S. aureus. Cite this article:Bone Joint Res. 2020;9(2):71–76


Bone & Joint Research
Vol. 9, Issue 8 | Pages 484 - 492
1 Aug 2020
Zhang W Fang X Shi T Cai Y Huang Z Zhang C Lin J Li W

Aims. To explore the effect of different types of articulating antibiotic-loaded cement spacers in two-stage revision for chronic hip prosthetic joint infection (PJI). Methods. A retrospective cohort study was performed involving 36 chronic PJI patients treated with different types of articulating antibiotic-loaded cement spacers between January 2014 and December 2017. The incidence of complications and the therapeutic effects of different types of antibiotic-loaded articulating cement spacers were compared. Results. A total of 36 patients with chronic hip PJI were included. Of these, 13 patients were treated with spacers with Kirschner wires as an endoskeleton (group I), ten patients were treated with spacers with a cemented femoral prosthesis as an endoskeleton (group II), and 13 patients were treated with cemented femoral prostheses combined with polyethylene sockets as a spacer (group III). All patients were followed for 12 to 60 months, with a mean follow-up period of 26.44 months (SEM 14.09). Infection was controlled in 34 patients (94.44%), and there were no significant differences in the eradication rate among the three groups (p = 0.705), but the risk of complications related to the spacer in group III was significantly lower than that in groups I and II (p = 0.006). Conclusion. Articulating antibiotic-loaded cement spacers is effective in the treatment of chronic hip PJI, but we must pay attention to the occurrence of spacer fracture and dislocation, which can lead to poor joint function. The risk of spacer-related mechanical complications is low, and better joint function can be achieved when using cemented femoral prostheses combined with polyethylene sockets as spacers. Cite this article: Bone Joint Res 2020;9(8):484–492


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1160 - 1167
1 Sep 2019
Wang WT Li YQ Guo YM Li M Mei HB Shao JF Xiong Z Li J Canavese F Chen SY

Aims. The aim of this study was to clarify the factors that predict the development of avascular necrosis (AVN) of the femoral head in children with a fracture of the femoral neck. Patients and Methods. We retrospectively reviewed 239 children with a mean age of 10.0 years (. sd. 3.9) who underwent surgical treatment for a femoral neck fracture. Risk factors were recorded, including age, sex, laterality, mechanism of injury, initial displacement, the type of fracture, the time to reduction, and the method and quality of reduction. AVN of the femoral head was assessed on radiographs. Logistic regression analysis was used to evaluate the independent risk factors for AVN. Chi-squared tests and Student’s t-tests were used for subgroup analyses to determine the risk factors for AVN. Results. We found that age (p = 0.006) and initial displacement (p = 0.001) were significant independent risk factors. Receiver operating characteristic (ROC) curve analysis indicated that 12 years of age was the cut-off for increasing the rate of AVN. Severe initial displacement (p = 0.021) and poor quality of reduction (p = 0.022) significantly increased the rate of AVN in patients aged 12 years or greater, while in those aged less than 12 years, the rate of AVN significantly increased only with initial displacement (p = 0.048). A poor reduction significantly increased the rate of AVN in patients treated by closed reduction (p = 0.026); screw and plate fixation was preferable to cannulated screw or Kirschner wire (K-wire) fixation for decreasing the rate of AVN in patients treated by open reduction (p = 0.034). Conclusion. The rate of AVN increases with age, especially in patients aged 12 years or greater, and with the severity of displacement. In patients treated by closed reduction, anatomical reduction helps to decrease the rate of AVN, while in those treated by open reduction, screw and plate fixation was preferable to fixation using cannulated screws or K-wires. Cite this article: Bone Joint J 2019;101-B:1160–1167


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 413 - 417
1 Apr 2002
McLauchlan GJ Cowan B Annan IH Robb JE

In a prospective, randomised controlled trial, 68 children who had a completely displaced metaphyseal fracture of the distal radius were treated either by manipulation (MUA) and application of an above-elbow cast alone or by the additional insertion of a percutaneous Kirschner (K-) wire. Full radiological follow-up to union was obtained in 65 children and 56 returned for clinical evaluation three months after injury. Maintenance of reduction was significantly better in the K-wire group and fewer follow-up radiographs were required. There was no significant difference in the clinical outcome measured three months after injury. Seven of 33 patients in the MUA group had to undergo a second procedure because of an unacceptable position compared with none of the 35 in the K-wire group (chi-squared test, p < 0.01). One patient in the K-wire group required exploration for recovery of a migrated wire. We conclude that the use of a percutaneous K-wire to augment the reduction of the fracture in children who have a completely displaced metaphyseal fracture of the distal radius is a safe and reliable way of maintaining alignment of the fracture


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 410 - 413
1 Mar 2016
Costa ML Jameson SS Reed MR

Aims. Our aim, using English Hospital Episode Statistics data before during and after the Distal Radius Acute Fracture Fixation Trial (DRAFFT), was to assess whether the results of the trial affected clinical practice. Patients and Methods. Data were grouped into six month intervals from July 2005 to December 2014. All patient episodes in the National Health Service involving emergency surgery for an isolated distal radial fracture were included. Results. Clinical practice in England had not changed in the five years before DRAFFT: 75% of patients were treated with plate fixation versus 12% with Kirschner (K)-wires. After the publication of the trial, the proportion of patients having K-wire fixation rose to 42% with a concurrent fall in the proportion having fixation with a plate to 48%. The proportion of ‘other’ procedures stayed the same. Take home message. It appears that surgeons in the United Kingdom do change their practice in response to large, pragmatic, multicentre clinical trials in musculoskeletal trauma. Cite this article: Bone Joint J 2016;98-B:410–13


Bone & Joint Open
Vol. 5, Issue 7 | Pages 581 - 591
12 Jul 2024
Wang W Xiong Z Huang D Li Y Huang Y Guo Y Andreacchio A Canavese F Chen S

Aims

To investigate the risk factors for unsuccessful radial head reduction (RHR) in children with chronic Monteggia fractures (CMFs) treated surgically.

Methods

A total of 209 children (mean age 6.84 years (SD 2.87)), who underwent surgical treatment for CMFs between March 2015 and March 2023 at six institutions, were retrospectively reviewed. Assessed risk factors included age, sex, laterality, dislocation direction and distance, preoperative proximal radial metaphysis width, time from injury to surgery, reduction method, annular ligament reconstruction, radiocapitellar joint fixation, ulnar osteotomy, site of ulnar osteotomy, preoperative and postoperative ulnar angulation, ulnar fixation method, progressive ulnar distraction, and postoperative cast immobilization. Independent-samples t-test, chi-squared test, and logistic regression analysis were used to identify the risk factors associated with unsuccessful RHR.


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 112 - 123
1 Feb 2023
Duckworth AD Carter TH Chen MJ Gardner MJ Watts AC

Despite being one of the most common injuries around the elbow, the optimal treatment of olecranon fractures is far from established and stimulates debate among both general orthopaedic trauma surgeons and upper limb specialists. It is almost universally accepted that stable non-displaced fractures can be safely treated nonoperatively with minimal specialist input. Internal fixation is recommended for the vast majority of displaced fractures, with a range of techniques and implants to choose from. However, there is concern regarding the complication rates, largely related to symptomatic metalwork resulting in high rates of implant removal. As the number of elderly patients sustaining these injuries increases, we are becoming more aware of the issues associated with fixation in osteoporotic bone and the often fragile soft-tissue envelope in this group. Given this, there is evidence to support an increasing role for nonoperative management in this high-risk demographic group, even in those presenting with displaced and/or multifragmentary fracture patterns. This review summarizes the available literature to date, focusing predominantly on the management techniques and available implants for stable fractures of the olecranon. It also offers some insights into the potential avenues for future research, in the hope of addressing some of the pertinent questions that remain unanswered.

Cite this article: Bone Joint J 2023;105-B(2):112–123.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 965 - 968
1 Nov 1991
Hope P Williamson D Coates C Cole W

A prospective randomised clinical trial was undertaken to compare biodegradable polyglycolic acid pins with standard Kirschner wires used to fix displaced elbow fractures in children. Twenty-four children were enrolled in the trial; 14 had fractures of the lateral condyle of the humerus, eight of the medial epicondyle and two had olecranon fractures. Eleven fractures were fixed with Kirschner wires and 13 with polyglycolic acid pins. Fracture union with full function occurred in all cases within six months. Kirschner wires caused problems including infection in three cases, soft-tissue ossification in one and they required removal under general anaesthesia in nine cases. No such complications occurred with polyglycolic acid pins but one patient in this group developed avascular necrosis and premature fusion of the medial epicondyle


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 137 - 140
1 Jan 2002
Piska M Yang L Reed M Saleh M

An innovative Kirschner (K-) wire point was developed and compared in fresh pig femora in terms of drilling efficiency and temperature elevation with the trochar and diamond points currently used in clinical practice. The tips of thermal couples were machined to the defined geometry and the temperature measured during drilling. Using the same drill speed (rev/min) and feed rate, the new K-wire point produced the lowest thrust force and torque as measured by a Kistler dynamometer. Drill point temperatures were highest with the trochar geometry (129 ± 6°C), followed by the diamond (98 ± 7°C). The lowest temperatures were recorded with the Medin K-wire (66 ± 2°C). On repeated drilling it could be used for up to 30 holes before reaching the less satisfactory drill performance of the diamond tip. The new K-wire provides a better alternative as it requires less effort for insertion, generates less heat and may be re-used


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims

This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA).

Methods

From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery.


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 449 - 454
15 Mar 2023
Zhang C Wang C Duan N Zhou D Ma T

Aims

The aim of this study was to assess the safety and clinical outcome of patients with a femoral shaft fracture and a previous complex post-traumatic femoral malunion who were treated with a clamshell osteotomy and fixation with an intramedullary nail (IMN).

Methods

The study involved a retrospective analysis of 23 patients. All had a previous, operatively managed, femoral shaft fracture with malunion due to hardware failure. They were treated with a clamshell osteotomy between May 2015 and March 2020. The mean age was 42.6 years (26 to 62) and 15 (65.2%) were male. The mean follow-up was 2.3 years (1 to 5). Details from their medical records were analyzed. Clinical outcomes were assessed using the quality of correction of the deformity, functional recovery, the healing time of the fracture, and complications.


Bone & Joint 360
Vol. 12, Issue 1 | Pages 26 - 29
1 Feb 2023

The February 2023 Wrist & Hand Roundup360 looks at: ‘Self-care’ protocol for minimally displaced distal radius fractures; Treatment strategies for acute Seymour fractures in children and adolescents: including crushed open fractures; Routinely collected outcomes of proximal row carpectomy; Moving minor hand surgeries in the office-based procedure room: a population-based trend analysis; A comparison between robotic-assisted scaphoid screw fixation and a freehand technique for acute scaphoid fracture: a randomized, controlled trial; Factors associated with conversion to surgical release after a steroid injection in patients with a trigger finger; Two modern total wrist arthroplasties: a randomized comparison; Triangular fibrocartilage complex suture repair reliable even in ulnar styloid nonunion.


Bone & Joint Open
Vol. 4, Issue 9 | Pages 682 - 688
6 Sep 2023
Hampton M Balachandar V Charalambous CP Sutton PM

Aims

Aseptic loosening is the most common cause of failure following cemented total knee arthroplasty (TKA), and has been linked to poor cementation technique. We aimed to develop a consensus on the optimal technique for component cementation in TKA.

Methods

A UK-based, three-round, online modified Delphi Expert Consensus Study was completed focusing on cementation technique in TKA. Experts were identified as having a minimum of five years’ consultant experience in the NHS and fulfilling any one of the following criteria: a ‘high volume’ knee arthroplasty practice (> 150 TKAs per annum) as identified from the National joint Registry of England, Wales, Northern Ireland and the Isle of Man; a senior author of at least five peer reviewed articles related to TKA in the previous five years; a surgeon who is named trainer for a post-certificate of comletion of training fellowship in TKA.


Bone & Joint 360
Vol. 3, Issue 6 | Pages 23 - 26
1 Dec 2014

The December 2014 Trauma Roundup. 360 . looks at: infection and temporising external fixation; Vitamin C in distal radial fractures; DRAFFT: Cheap and cheerful Kirschner wires win out; femoral neck fractures not as stable as they might be; displaced sacral fractures give high morbidity and mortality; sanders and calcaneal fractures: a 20-year experience; bleeding and pelvic fractures; optimising timing for acetabular fractures; and tibial plateau fractures


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 331 - 340
1 Mar 2023
Vogt B Toporowski G Gosheger G Laufer A Frommer A Kleine-Koenig M Roedl R Antfang C

Aims

Temporary hemiepiphysiodesis (HED) is applied to children and adolescents to correct angular deformities (ADs) in long bones through guided growth. Traditional Blount staples or two-hole plates are mainly used for this indication. Despite precise surgical techniques and attentive postoperative follow-up, implant-associated complications are frequently described. To address these pitfalls, a flexible staple was developed to combine the advantages of the established implants. This study provides the first results of guided growth using the new implant and compares these with the established two-hole plates and Blount staples.

Methods

Between January 2013 and December 2016, 138 patients (22 children, 116 adolescents) with genu valgum or genu varum were treated with 285 flexible staples. The minimum follow-up was 24 months. These results were compared with 98 patients treated with 205 two-hole plates and 92 patients treated with 535 Blount staples. In long-standing anteroposterior radiographs, mechanical axis deviations (MADs) were measured before and during treatment to analyze treatment efficiency. The evaluation of the new flexible staple was performed according to the idea, development, evaluation, assessment, long-term (IDEAL) study framework (Stage 2a).


Bone & Joint 360
Vol. 2, Issue 5 | Pages 24 - 27
1 Oct 2013

The October 2013 Wrist & Hand Roundup. 360 . looks at: Cost effectiveness of Dupuytren’s surgery; A 'new horizon' in distal radius imaging; Undisplaced means undisplaced; The mystery of the distal radial fracture continues; How thick is thick enough?: articular cartilage step off revisited; Is the midcarpal joint more important than we think?; Plates and Kirschner wires; Better early results with an IM nail?


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 543 - 550
1 May 2023
Abel F Avrumova F Goldman SN Abjornson C Lebl DR

Aims

The aim of this study was to assess the accuracy of pedicle screw placement, as well as intraoperative factors, radiation exposure, and complication rates in adult patients with degenerative disorders of the thoracic and lumbar spines who have undergone robotic-navigated spinal surgery using a contemporary system.

Methods

The authors reviewed the prospectively collected data on 196 adult patients who had pedicle screws implanted with robot-navigated assistance (RNA) using the Mazor X Stealth system between June 2019 and March 2022. Pedicle screws were implanted by one experienced spinal surgeon after completion of a learning period. The accuracy of pedicle screw placement was determined using intraoperative 3D fluoroscopy.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 1004 - 1006
1 Jul 2015
Middleton SD McNiven N Griffin EJ Anakwe RE Oliver CW

We define the long-term outcomes and rates of further operative intervention following displaced Bennett’s fractures treated with Kirschner (K-) wire fixation between 1996 and 2009. We retrospectively identified 143 patients (127 men and 16 women) with a mean age at the time of injury of 33.2 years (18 to 75). Electronic records were examined and patients were invited to complete the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire in addition to a satisfaction questionnaire. The time since injury was a mean of 11.5 years (3.4 to 18.5). In total 11 patients had died, one had developed dementia and 12 patients were lost to follow-up. This left 119 patients available for recruitment. Of these, 57 did not respond, leaving a study group of 62 patients. Patients reported excellent functional outcomes and high levels of satisfaction at follow-up. Median satisfaction was 94% (interquartile range 91.5 to 97.5) and the mean DASH score was 3.0 (0 to 38). None of the patients had undergone salvage procedures and none of the responders had changed occupation or sporting activities. Long-term patient reported outcomes following displaced Bennett’s fractures treated by closed reduction and K-wire fixation show excellent functional results and a high level of patient satisfaction. The rate of infection is low and similar to other surgical procedures with percutaneous K-wires. Cite this article: Bone Joint J 2015;97-B:1004–6


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 16 - 18
1 Jan 2024
Metcalfe D Perry DC

Displaced fractures of the distal radius in children are usually reduced under sedation or general anaesthesia to restore anatomical alignment before the limb is immobilized. However, there is growing evidence of the ability of the distal radius to remodel rapidly, raising doubts over the benefit to these children of restoring alignment. There is now clinical equipoise concerning whether or not young children with displaced distal radial fractures benefit from reduction, as they have the greatest ability to remodel. The Children’s Radius Acute Fracture Fixation Trial (CRAFFT), funded by the National Institute for Health and Care Research, aims to definitively answer this question and determine how best to manage severely displaced distal radial fractures in children aged up to ten years.

Cite this article: Bone Joint J 2024;106-B(1):16–18.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 705 - 710
1 May 2015
Ozmeric A Yucens M Gultaç E Açar HI Aydogan NH Gül D Alemdaroglu KB

We hypothesised that the anterior and posterior walls of the body of the first sacral vertebra could be visualised with two different angles of inlet view, owing to the conical shape of the sacrum. Six dry male cadavers with complete pelvic rings and eight dry sacrums with K-wires were used to study the effect of canting (angling the C-arm) the fluoroscope towards the head in 5° increments from 10° to 55°. Fluoroscopic images were taken in each position. Anterior and posterior angles of inclination were measured between the upper sacrum and the vertical line on the lateral view. Three authors separately selected the clearest image for overlapping anterior cortices and the upper sacral canal in the cadaveric models. The dry bone and K-wire models were scored by the authors, being sure to check whether the K-wire was in or out. In the dry bone models the mean score of the relevant inlet position of the anterior or posterior inclination was 8.875 (standard deviation (. sd. ) 0.35), compared with the inlet position of the opposite inclination of –5.75 (. sd. 4.59). We found that two different inlet views should be used separately to evaluate the borders of the body of the sacrum using anterior and posterior inclination angles of the sacrum, during placement of iliosacral screws. Cite this article: Bone Joint J 2015;97-B:705–10


Bone & Joint Research
Vol. 11, Issue 10 | Pages 700 - 714
4 Oct 2022
Li J Cheung W Chow SK Ip M Leung SYS Wong RMY

Aims

Biofilm-related infection is a major complication that occurs in orthopaedic surgery. Various treatments are available but efficacy to eradicate infections varies significantly. A systematic review was performed to evaluate therapeutic interventions combating biofilm-related infections on in vivo animal models.

Methods

Literature research was performed on PubMed and Embase databases. Keywords used for search criteria were “bone AND biofilm”. Information on the species of the animal model, bacterial strain, evaluation of biofilm and bone infection, complications, key findings on observations, prevention, and treatment of biofilm were extracted.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 212 - 218
1 Feb 2024
Liu S Su Y

Aims

Medial humeral epicondyle fractures (MHEFs) are common elbow fractures in children. Open reduction should be performed in patients with MHEF who have entrapped intra-articular fragments as well as displacement. However, following open reduction, transposition of the ulnar nerve is disputed. The aim of this study is to evaluate the need for ulnar nerve exploration and transposition.

Methods

This was a retrospective cohort study. The clinical data of patients who underwent surgical treatment of MHEF in our hospital from January 2015 to January 2022 were collected. The patients were allocated to either transposition or non-transposition groups. Data for sex, age, cause of fracture, duration of follow-up, Papavasiliou and Crawford classification, injury-to-surgery time, preoperative ulnar nerve symptoms, intraoperative exploration of ulnar nerve injury, surgical incision length, intraoperative blood loss, postoperative ulnar nerve symptoms, complications, persistent ulnar neuropathy, and elbow joint function were analyzed. Binary logistic regression analysis was used for statistical analysis.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 46 - 52
19 Jan 2024
Assink N ten Duis K de Vries JPM Witjes MJH Kraeima J Doornberg JN IJpma FFA

Aims

Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery.

Methods

A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group.


Bone & Joint Research
Vol. 12, Issue 8 | Pages 504 - 511
23 Aug 2023
Wang C Liu S Chang C

Aims

This study aimed to establish the optimal fixation methods for calcaneal tuberosity avulsion fractures with different fragment thicknesses in a porcine model.

Methods

A total of 36 porcine calcanea were sawed to create simple avulsion fractures with three different fragment thicknesses (5, 10, and 15 mm). They were randomly fixed with either two suture anchors or one headless screw. Load-to-failure and cyclic loading tension tests were performed for the biomechanical analysis.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 613 - 622
1 Jun 2024
Shen J Wei Z Wu H Wang X Wang S Wang G Luo F Xie Z

Aims

The aim of the present study was to assess the outcomes of the induced membrane technique (IMT) for the management of infected segmental bone defects, and to analyze predictive factors associated with unfavourable outcomes.

Methods

Between May 2012 and December 2020, 203 patients with infected segmental bone defects treated with the IMT were enrolled. The digital medical records of these patients were retrospectively analyzed. Factors associated with unfavourable outcomes were identified through logistic regression analysis.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 803 - 808
1 Jun 2013
Choi GW Choi WJ Yoon HS Lee JW

We reviewed 91 patients (103 feet) who underwent a Ludloff osteotomy combined with additional procedures. According to the combined procedures performed, patients were divided into Group I (31 feet; first web space release), Group II (35 feet; Akin osteotomy and trans-articular release), or Group III (37 feet; Akin osteotomy, supplementary axial Kirschner (K-) wire fixation, and trans-articular release). Each group was then further subdivided into severe and moderate deformities. The mean hallux valgus angle correction of Group II was significantly greater than that of Group I (p = 0.001). The mean intermetatarsal angle correction of Group III was significantly greater than that of Group II (p < 0.001). In severe deformities, post-operative incongruity of the first metatarsophalangeal joint was least common in Group I (p = 0.026). Akin osteotomy significantly increased correction of the hallux valgus angle, while a supplementary K-wire significantly reduced the later loss of intermetatarsal angle correction. First web space release can be recommended for severe deformity. Additionally, K-wire fixation (odds ratio (OR) 5.05 (95% confidence interval (CI) 1.21 to 24.39); p = 0.032) and the pre-operative hallux valgus angle (OR 2.20 (95% CI 1.11 to 4.73); p = 0.001) were shown to be factors affecting recurrence of hallux valgus after Ludloff osteotomy. Cite this article: Bone Joint J 2013;95-B:803–8


Bone & Joint Open
Vol. 5, Issue 8 | Pages 652 - 661
8 Aug 2024
Taha R Davis T Montgomery A Karantana A

Aims

The aims of this study were to describe the epidemiology of metacarpal shaft fractures (MSFs), assess variation in treatment and complications following standard care, document hospital resource use, and explore factors associated with treatment modality.

Methods

A multicentre, cross-sectional retrospective study of MSFs at six centres in the UK. We collected and analyzed healthcare records, operative notes, and radiographs of adults presenting within ten days of a MSF affecting the second to fifth metacarpal between 1 August 2016 and 31 July 2017. Total emergency department (ED) attendances were used to estimate prevalence.


Bone & Joint 360
Vol. 11, Issue 5 | Pages 34 - 36
1 Oct 2022


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 131 - 136
1 Jan 2016
Kurien T Price KR Pearson RG Dieppe C Hunter JB

A retrospective study was performed in 100 children aged between two and 16 years, with a dorsally angulated stable fracture of the distal radius or forearm, who were treated with manipulation in the emergency department (ED) using intranasal diamorphine and 50% oxygen and nitrous oxide. Pre- and post-manipulation radiographs, the final radiographs and the clinical notes were reviewed. A successful reduction was achieved in 90 fractures (90%) and only three children (3%) required remanipulation and Kirschner wire fixation or internal fixation. The use of Entonox and intranasal diamorphine is safe and effective for the closed reduction of a stable paediatric fracture of the distal radius and forearm in the ED. . By facilitating discharge on the same day, there is a substantial cost benefit to families and the NHS and we recommend this method. Take home message: Simple easily reducible fractures of the distal radius and forearm in children can be successfully and safely treated in the ED using this approach, thus avoiding theatre admission and costly hospital stay. . Cite this article: Bone Joint J 2016;97-B:131–6