Advertisement for orthosearch.org.uk
Results 1 - 50 of 219
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1458 - 1463
1 Nov 2013
Won S Lee Y Ha Y Suh Y Koo K

Pre-operative planning for total hip replacement (THR) is challenging in hips with severe acetabular deformities, including those with a hypoplastic acetabulum or severe defects and in the presence of arthrodesis or ankylosis. We evaluated whether a Rapid Prototype (RP) model, which is a life-sized reproduction based on three-dimensional CT scans, can determine the feasibility of THR and provide information about the size and position of the acetabular component in severe acetabular deformities. THR was planned using an RP model in 21 complex hips in five men (five hips) and 16 women (16 hips) with a mean age of 47.7 years (24 to 70) at operation. An acetabular component was implanted successfully and THR completed in all hips. The acetabular component used was within 2 mm of the predicted size in 17 hips (80.9%). All of the acetabular components and femoral stems had radiological evidence of bone ingrowth and stability at the final follow-up, without any detectable wear or peri-prosthetic osteolysis. The RP model allowed a simulated procedure pre-operatively and was helpful in determining the feasibility of THR pre-operatively, and to decide on implant type, size and position in complex THRs. Cite this article: Bone Joint J 2013;95-B:1458–63


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 333 - 340
1 Mar 2009
Sariali E Mouttet A Pasquier G Durante E Catone Y

Pre-operative computerised three-dimensional planning was carried out in 223 patients undergoing total hip replacement with a cementless acetabular component and a cementless modular-neck femoral stem. Components were chosen which best restored leg length and femoral offset. The post-operative restoration of the anatomy was assessed by CT and compared with the pre-operative plan. The component implanted was the same as that planned in 86% of the hips for the acetabular implant, 94% for the stem, and 93% for the neck-shaft angle. The rotational centre of the hip was restored with a mean accuracy of 0.73 mm (. sd. 3.5) craniocaudally and 1.2 mm (. sd. 2) laterally. Limb length was restored with a mean accuracy of 0.3 mm (. sd. 3.3) and femoral offset with a mean accuracy of 0.8 mm (. sd. 3.1). This method appears to offer high accuracy in hip reconstruction as the difficulties likely to be encountered when restoring the anatomy can be anticipated and solved pre-operatively by optimising the selection of implants. Modularity of the femoral neck helped to restore the femoral offset and limb length


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 158 - 159
1 Jan 1992
Watson J Hollingdale J


Bone & Joint Research
Vol. 6, Issue 10 | Pages 577 - 583
1 Oct 2017
Sallent A Vicente M Reverté MM Lopez A Rodríguez-Baeza A Pérez-Domínguez M Velez R

Objectives. To assess the accuracy of patient-specific instruments (PSIs) versus standard manual technique and the precision of computer-assisted planning and PSI-guided osteotomies in pelvic tumour resection. Methods. CT scans were obtained from five female cadaveric pelvises. Five osteotomies were designed using Mimics software: sacroiliac, biplanar supra-acetabular, two parallel iliopubic and ischial. For cases of the left hemipelvis, PSIs were designed to guide standard oscillating saw osteotomies and later manufactured using 3D printing. Osteotomies were performed using the standard manual technique in cases of the right hemipelvis. Post-resection CT scans were quantitatively analysed. Student’s t-test and Mann–Whitney U test were used. Results. Compared with the manual technique, PSI-guided osteotomies improved accuracy by a mean 9.6 mm (p < 0.008) in the sacroiliac osteotomies, 6.2 mm (p < 0.008) and 5.8 mm (p < 0.032) in the biplanar supra-acetabular, 3 mm (p < 0.016) in the ischial and 2.2 mm (p < 0.032) and 2.6 mm (p < 0.008) in the parallel iliopubic osteotomies, with a mean linear deviation of 4.9 mm (p < 0.001) for all osteotomies. Of the manual osteotomies, 53% (n = 16) had a linear deviation > 5 mm and 27% (n = 8) were > 10 mm. In the PSI cases, deviations were 10% (n = 3) and 0 % (n = 0), respectively. For angular deviation from pre-operative plans, we observed a mean improvement of 7.06° (p < 0.001) in pitch and 2.94° (p < 0.001) in roll, comparing PSI and the standard manual technique. Conclusion. In an experimental study, computer-assisted planning and PSIs improved accuracy in pelvic tumour resections, bringing osteotomy results closer to the parameters set in pre-operative planning, as compared with standard manual techniques. Cite this article: A. Sallent, M. Vicente, M. M. Reverté, A. Lopez, A. Rodríguez-Baeza, M. Pérez-Domínguez, R. Velez. How 3D patient-specific instruments improve accuracy of pelvic bone tumour resection in a cadaveric study. Bone Joint Res 2017;6:577–583. DOI: 10.1302/2046-3758.610.BJR-2017-0094.R1


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 44 - 48
1 Jan 2006
Keene G Simpson D Kalairajah Y

Twenty patients underwent simultaneous bilateral medial unicompartmental knee arthroplasty. Pre-operative hip-knee-ankle alignment and valgus stress radiographs were used to plan the desired post-operative alignment of the limb in accordance with established principles for unicompartmental arthroplasty. In each patient the planned alignment was the same for both knees. Overall, the mean planned post-operative alignment was to 2.3° of varus (0° to 5°). The side and starting order of surgery were randomised, using conventional instrumentation for one knee and computer-assisted surgery for the opposite side. The mean variation between the pre-operative plan and the achieved correction in the navigated and the non-navigated limb was 0.9° (. sd. 1.1; 0° to 4°) and 2.8° (. sd. 1.4; 1° to 7°), respectively. Using the Wilcoxon signed rank test, we found the difference in variation statistically significant (p < 0.001). Assessment of lower limb alignment in the non-navigated group revealed that 12 (60%) were within ± 2° of the pre-operative plan, compared to 17 (87%) of the navigated cases. Computer-assisted surgery significantly improves the post-operative alignment of medial unicompartmental knee arthroplasty compared to conventional techniques in patients undergoing bilateral simultaneous arthroplasty. Improved alignment after arthroplasty is associated with better function and increased longevity


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1080 - 1085
1 Aug 2016
Gauci MO Boileau P Baba M Chaoui J Walch G

Aims. Patient-specific glenoid guides (PSGs) claim an improvement in accuracy and reproducibility of the positioning of components in total shoulder arthroplasty (TSA). The results have not yet been confirmed in a prospective clinical trial. Our aim was to assess whether the use of PSGs in patients with osteoarthritis of the shoulder would allow accurate and reliable implantation of the glenoid component. Patients and Methods. A total of 17 patients (three men and 14 women) with a mean age of 71 years (53 to 81) awaiting TSA were enrolled in the study. Pre- and post-operative version and inclination of the glenoid were measured on CT scans, using 3D planning automatic software. During surgery, a congruent 3D-printed PSG was applied onto the glenoid surface, thus determining the entry point and orientation of the central guide wire used for reaming the glenoid and the introduction of the component. Manual segmentation was performed on post-operative CT scans to compare the planned and the actual position of the entry point (mm) and orientation of the component (°). Results. The mean error in the accuracy of the entry point was -0.1 mm (standard deviation (. sd. ) 1.4) in the horizontal plane, and 0.8 mm (. sd. 1.3) in the vertical plane. The mean error in the orientation of the glenoid component was 3.4° (. sd. 5.1°) for version and 1.8° (. sd. 5.3°) for inclination. Conclusion. Pre-operative planning with automatic software and the use of PSGs provides accurate and reproducible positioning and orientation of the glenoid component in anatomical TSA. Cite this article: Bone Joint J 2016;98-B:1080–5


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 54 - 59
1 Jan 2016
González Della Valle A Sharrock N Barlow M Caceres L Go G Salvati EA

We describe our technique and rationale using hybrid fixation for primary total hip arthroplasty (THA) at the Hospital for Special Surgery. Modern uncemented acetabular components have few screw holes, or no holes, polished inner surfaces, improved locking mechanisms, and maximised thickness and shell-liner conformity. Uncemented sockets can be combined with highly cross-linked polyethylene liners, which have demonstrated very low wear and osteolysis rates after ten to 15 years of implantation. The results of cement fixation with a smooth or polished surface finished stem have been excellent, virtually eliminating complications seen with cementless fixation like peri-operative femoral fractures and thigh pain. Although mid-term results of modern cementless stems are encouraging, the long-term data do not show reduced revision rates for cementless stems compared with cemented smooth stems. In this paper we review the conduct of a hybrid THA, with emphasis on pre-operative planning, surgical technique, hypotensive epidural anaesthesia, and intra-operative physiology. Cite this article: Bone Joint J 2016;98-B(1 Suppl A):54–9


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 147 - 149
1 Feb 2015
Morgan-Jones R Oussedik SIS Graichen H Haddad FS

Revision knee arthroplasty presents a number of challenges, not least of which is obtaining solid primary fixation of implants into host bone. Three anatomical zones exist within both femur and tibia which can be used to support revision implants. These consist of the joint surface or epiphysis, the metaphysis and the diaphysis. The methods by which fixation in each zone can be obtained are discussed. The authors suggest that solid fixation should be obtained in at least two of the three zones and emphasise the importance of pre-operative planning and implant selection. Cite this article: Bone Joint J 2015;97-B:147–9


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 780 - 785
1 Jun 2015
Baauw M van Hellemondt GG van Hooff ML Spruit M

We evaluated the accuracy with which a custom-made acetabular component could be positioned at revision arthroplasty of the hip in patients with a Paprosky type 3 acetabular defect. A total of 16 patients with a Paprosky type 3 defect underwent revision surgery using a custom-made trabecular titanium implant. There were four men and 12 women with a median age of 67 years (48 to 79). The planned inclination (INCL), anteversion (AV), rotation and centre of rotation (COR) of the implant were compared with the post-operative position using CT scans. A total of seven implants were malpositioned in one or more parameters: one with respect to INCL, three with respect to AV, four with respect to rotation and five with respect to the COR. To the best of our knowledge, this is the first study in which CT data acquired for the pre-operative planning of a custom-made revision acetabular implant have been compared with CT data on the post-operative position. The results are encouraging. Cite this article: Bone Joint J 2015; 97-B:780–5


The Bone & Joint Journal
Vol. 97-B, Issue 10_Supple_A | Pages 30 - 39
1 Oct 2015
Baldini A Castellani L Traverso F Balatri A Balato G Franceschini V

Primary total knee arthroplasty (TKA) is a reliable procedure with reproducible long-term results. Nevertheless, there are conditions related to the type of patient or local conditions of the knee that can make it a difficult procedure. The most common scenarios that make it difficult are discussed in this review. These include patients with many previous operations and incisions, and those with severe coronal deformities, genu recurvatum, a stiff knee, extra-articular deformities and those who have previously undergone osteotomy around the knee and those with chronic dislocation of the patella. Each condition is analysed according to the characteristics of the patient, the pre-operative planning and the reported outcomes. . When approaching the difficult primary TKA surgeons should use a systematic approach, which begins with the review of the existing literature for each specific clinical situation. Cite this article: Bone Joint J 2015;97-B(10 Suppl A):30–9


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 239 - 243
1 Mar 2004
Cutler L Molloy A Dhukuram V Bass A

Distal tibial physeal fractures are the second most common growth plate injury and the most common cause of growth arrest and deformity. This study assesses the accuracy of pre-operative planning for placement of the screws in these fractures using either standard radiographs or CT scans. We studied 62 consecutive physeal fractures over a period of four years. An outline of a single cut of the CT scan was used for each patient. An ideal position for the screw was determined as being perpendicular to and at the midpoint of the fracture. The difference in entry point and direction of the screw between the ideal and the observers’ assessments were compared using the paired Student’s t-test. There was a statistically significant improvement (p < 0.0001) in the accuracy of the point of insertion and the direction of the screw on the pre-operative plan when CT scans were used rather than plain radiographs. We would, therefore, recommend that CT scans are routinely used in the pre-operative assessment and treatment of distal tibial physeal fractures


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 153 - 158
1 Nov 2013
Victor J Premanathan A

We have investigated the benefits of patient specific instrument guides, applied to osteotomies around the knee. Single, dual and triple planar osteotomies were performed on tibias or femurs in 14 subjects. In all patients, a detailed pre-operative plan was prepared based upon full leg standing radiographic and CT scan information. The planned level of the osteotomy and open wedge resection was relayed to the surgery by virtue of a patient specific guide developed from the images. The mean deviation between the planned wedge angle and the executed wedge angle was 0° (-1 to 1, . sd. 0.71) in the coronal plane and 0.3° (-0.9 to 3, . sd. 1.14) in the sagittal plane. The mean deviation between the planned hip, knee, ankle angle (HKA) on full leg standing radiograph and the post-operative HKA was 0.3° (-1 to 2, . sd. 0.75). It is concluded that this is a feasible and valuable concept from the standpoint of pre-operative software based planning, surgical application and geometrical accuracy of outcome. . Cite this article: Bone Joint J 2013;95-B, Supple A:153–8


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 914 - 921
1 Jul 2010
Karachalios T Hartofilakidis G

This paper reviews the current knowledge relating to the management of adult patients with congenital hip disease. Orthopaedic surgeons who treat these patients with a total hip replacement should be familiar with the arguments concerning its terminology, be able to recognise the different anatomical abnormalities and to undertake thorough pre-operative planning in order to replace the hip using an appropriate surgical technique and the correct implants and be able to anticipate the clinical outcome and the complications


Bone & Joint Research
Vol. 4, Issue 8 | Pages 128 - 133
1 Aug 2015
Kuwashima U Okazaki K Tashiro Y Mizu-Uchi H Hamai S Okamoto S Murakami K Iwamoto Y

Objectives. Because there have been no standard methods to determine pre-operatively the thickness of resection of the proximal tibia in unicompartmental knee arthroplasty (UKA), information about the relationship between the change of limb alignment and the joint line elevation would be useful for pre-operative planning. The purpose of this study was to clarify the correlation between the change of limb alignment and the change of joint line height at the medial compartment after UKA. Methods. A consecutive series of 42 medial UKAs was reviewed retrospectively. These patients were assessed radiographically both pre- and post-operatively with standing anteroposterior radiographs. The thickness of bone resection at the proximal tibia and the distal femur was measured radiographically. The relationship between the change of femorotibial angle (δFTA) and the change of joint line height, was analysed. Results. The mean pre- and post-operative FTA was 180.5° (172.2° to 184.8°) and 175.0° (168.5° to 178.9°), respectively. The mean δFTA was 5.5° (2.3° to 10.1°). The joint line elevation of the tibia (JLET) was 4.4 mm (2.1 to 7.8). The δFTA was correlated with the JLET (correlation coefficient 0.494, p = 0.0009). Conclusions. This study indicated that there is a significant correlation between the change of limb alignment and joint line elevation. This observation suggests that it is possible to know the requirement of elevation of the joint line to obtain the desired correction of limb alignment, and to predict the requirement of bone resection of the proximal tibia pre-operatively. Cite this article: Bone Joint Res 2015;4:128–133


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 31 - 36
1 Nov 2013
Gustke K

Total hip replacement for developmental hip dysplasia is challenging. The anatomical deformities on the acetabular and femoral sides are difficult to predict. The Crowe classification is usually used to describe these cases – however, it is not a very helpful tool for pre-operative planning. Small acetabular components, acetabular augments, and modular femoral components should be available for all cases. Regardless of the Crowe classification, the surgeon must be prepared to perform a femoral osteotomy for shortening, or to correct rotation, and/or angulation. Cite this article: Bone Joint J 2013;95-B, Supple A:31–6


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1360 - 1368
1 Oct 2016
Waterson HB Clement ND Eyres KS Mandalia VI Toms AD

Aims. Our aim was to compare kinematic with mechanical alignment in total knee arthroplasty (TKA). Patients and Methods. We performed a prospective blinded randomised controlled trial to compare the functional outcome of patients undergoing TKA in mechanical alignment (MA) with those in kinematic alignment (KA). A total of 71 patients undergoing TKA were randomised to either kinematic (n = 36) or mechanical alignment (n = 35). Pre- and post-operative hip-knee-ankle radiographs were analysed. The knee injury and osteoarthritis outcome score (KOOS), American Knee Society Score, Short Form-36, Euro-Qol (EQ-5D), range of movement (ROM), two minute walk, and timed up and go tests were assessed pre-operatively and at six weeks, three and six months and one year post-operatively. Results. A total of 78% of the kinematically aligned group (28 patients) and 77% of the mechanically aligned group (27 patients) were within 3° of their pre-operative plan. There were no statistically significant differences in the mean KOOS (difference 1.3, 95% confidence interval (CI) -9.4 to 12.1, p = 0.80), EQ-5D (difference 0.8, 95% CI -7.9 to 9.6, p = 0.84), ROM (difference 0.1, 95% CI -6.0 to 6.1, p = 0.99), two minute distance tolerance (difference 20.0, 95% CI -52.8 to 92.8, p = 0.58), or timed up and go (difference 0.78, 95% CI -2.3 to 3.9, p = 0.62) between the groups at one year. Conclusion. Kinematically aligned TKAs appear to have comparable short-term results to mechanically aligned TKAs with no significant differences in function one year post-operatively. Further research is required to see if any theoretical long-term functional benefits of kinematic alignment are realised or if there are any potential effects on implant survival. Cite this article: Bone Joint J 2016;98-B:1360–8


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1281 - 1286
1 Oct 2009
Olsen M Davis ET Chiu M Gamble P Tumia N Boyle RA Schemitsch EH

The computed neck-shaft angle and the size of the femoral component were recorded in 100 consecutive hip resurfacings using imageless computer-navigation and compared with the angle measured before operation and with actual component implanted. The reliability of the registration was further analysed using ten cadaver femora. The mean absolute difference between the measured and navigated neck-shaft angle was 16.3° (0° to 52°). Navigation underestimated the measured neck-shaft angle in 38 patients and the correct implant size in 11. Registration of the cadaver femora tended to overestimate the correct implant size and provided a low level of repeatability in computing the neck-shaft angle. Prudent pre-operative planning is advisable for use in conjunction with imageless navigation since misleading information may be registered intraoperatively, which could lead to inappropriate sizing and positioning of the femoral component in hip resurfacing


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1457 - 1461
1 Nov 2012
Krishnan SP Dawood A Richards R Henckel J Hart AJ

Improvements in the surgical technique of total knee replacement (TKR) are continually being sought. There has recently been interest in three-dimensional (3D) pre-operative planning using magnetic resonance imaging (MRI) and CT. The 3D images are increasingly used for the production of patient-specific models, surgical guides and custom-made implants for TKR. The users of patient-specific instrumentation (PSI) claim that they allow the optimum balance of technology and conventional surgery by reducing the complexity of conventional alignment and sizing tools. In this way the advantages of accuracy and precision claimed by computer navigation techniques are achieved without the disadvantages of additional intra-operative inventory, new skills or surgical time. This review describes the terminology used in this area and debates the advantages and disadvantages of PSI


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 889 - 895
1 Jul 2014
Fink B Urbansky K Schuster P

We report our experience of revision total hip replacement (THR) using the Revitan curved modular titanium fluted revision stem in patients with a full spectrum of proximal femoral defects. A total of 112 patients (116 revisions) with a mean age of 73.4 years (39 to 90) were included in the study. The mean follow-up was 7.5 years (5.3 to 9.1). A total of 12 patients (12 hips) died but their data were included in the survival analysis, and four patients (4 hips) were lost to follow-up. The clinical outcome, proximal bone regeneration and subsidence were assessed for 101 hips. The mean Harris Hip Score was 88.2 (45.8 to 100) after five years and there was an increase of the mean Barnett and Nordin-Score, a measure of the proximal bone regeneration, of 20.8 (-3.1 to 52.7). Five stems had to be revised (4.3%), three (2.9%) showed subsidence, five (4.3%) a dislocation and two of 85 aseptic revisions (2.3%) a periprosthetic infection. . At the latest follow-up, the survival with revision of the stem as the endpoint was 95.7% (95% confidence interval 91.9% to 99.4%) and with aseptic loosening as the endpoint, was 100%. Peri-prosthetic fractures were not observed. We report excellent results with respect to subsidence, the risk of fracture, and loosening after femoral revision using a modular curved revision stem with distal cone-in-cone fixation. A successful outcome depends on careful pre-operative planning and the use of a transfemoral approach when the anatomy is distorted or a fracture is imminent, or residual cement or a partially-secured existing stem cannot be removed. The shortest appropriate stem should, in our opinion, be used and secured with > 3 cm fixation at the femoral isthmus, and distal interlocking screws should be used for additional stability when this goal cannot be realised. Cite this article: Bone Joint J 2014;96-B:889–95


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1332 - 1337
1 Oct 2010
Leung KS Tang N Cheung LWH Ng E

Fluoronavigation is an image-guided technology which uses intra-operative fluoroscopic images taken under a real-time tracking system and registration to guide surgical procedures. With the skeleton and the instrument registered, guidance under an optical tracking system is possible, allowing fixation of the fracture and insertion of an implant. This technology helps to minimise exposure to x-rays, providing multiplanar views for monitoring and accurate positioning of implants. It allows real-time interactive quantitative data for decision-making and expands the application of minimally invasive surgery. In orthopaedic trauma its use can be further enhanced by combining newer imaging technologies such as intra-operative three-dimensional fluoroscopy and optical image guidance, new advances in software for fracture reduction, and new tracking mechanisms using electromagnetic technology. The major obstacles for general and wider applications are the inability to track individual fracture fragments, no navigated real-time fracture reduction, and the lack of an objective assessment method for cost-effectiveness. We believe that its application will go beyond the operating theatre and cover all aspects of patient management, from pre-operative planning to intra-operative guidance and postoperative rehabilitation


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 188 - 197
1 Feb 2006
Cobb J Henckel J Gomes P Harris S Jakopec M Rodriguez F Barrett A Davies B

We performed a prospective, randomised controlled trial of unicompartmental knee arthroplasty comparing the performance of the Acrobot system with conventional surgery. A total of 27 patients (28 knees) awaiting unicompartmental knee arthroplasty were randomly allocated to have the operation performed conventionally or with the assistance of the Acrobot. The primary outcome measurement was the angle of tibiofemoral alignment in the coronal plane, measured by CT. Other secondary parameters were evaluated and are reported. All of the Acrobot group had tibiofemoral alignment in the coronal plane within 2° of the planned position, while only 40% of the conventional group achieved this level of accuracy. While the operations took longer, no adverse effects were noted, and there was a trend towards improvement in performance with increasing accuracy based on the Western Ontario and McMaster Universities Osteoarthritis Index and American Knee Society scores at six weeks and three months. The Acrobot device allows the surgeon to reproduce a pre-operative plan more reliably than is possible using conventional techniques which may have clinical advantages


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 67 - 69
1 Nov 2013
Brooks PJ

Dislocation is one of the most common causes of patient and surgeon dissatisfaction following hip replacement and to treat it, the causes must first be understood. Patient factors include age greater than 70 years, medical comorbidities, female gender, ligamentous laxity, revision surgery, issues with the abductors, and patient education. Surgeon factors include the annual quantity of procedures and experience, the surgical approach, adequate restoration of femoral offset and leg length, component position, and soft-tissue or bony impingement. Implant factors include the design of the head and neck region, and so-called skirts on longer neck lengths. There should be offset choices available in order to restore soft-tissue tension. Lipped liners aid in gaining stability, yet if improperly placed may result in impingement and dislocation. Late dislocation may result from polyethylene wear, soft-tissue destruction, trochanteric or abductor disruption and weakness, or infection. Understanding the causes of hip dislocation facilitates prevention in a majority of instances. Proper pre-operative planning includes the identification of patients with a high offset in whom inadequate restoration of offset will reduce soft-tissue tension and abductor efficiency. Component position must be accurate to achieve stability without impingement. Finally, patient education cannot be over-emphasised, as most dislocations occur early, and are preventable with proper instructions. Cite this article: Bone Joint J 2013;95-B, Supple A:67–9


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 668 - 673
1 May 2008
Karva AR Board TN Porter ML

We present a 25-year-old patient with juvenile rheumatoid arthritis and ankylosis of both hips and both knees treated by staged bilateral hip and knee arthroplasty. She was followed up for 18 months. We discuss the pre-operative planning, surgical details and post-operative rehabilitation


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 270 - 275
1 Feb 2012
Ilharreborde B Gaumetou E Souchet P Fitoussi F Presedo A Penneçot GF Mazda K

Percutaneous epiphysiodesis using transphyseal screws (PETS) has been developed for the treatment of lower limb discrepancies with the aim of replacing traditional open procedures. The goal of this study was to evaluate its efficacy and safety at skeletal maturity. A total of 45 consecutive patients with a mean skeletal age of 12.7 years (8.5 to 15) were included and followed until maturity. The mean efficacy of the femoral epiphysiodesis was 35% (14% to 87%) at six months and 66% (21% to 100%) at maturity. The mean efficacy of the tibial epiphysiodesis was 46% (18% to 73%) at six months and 66% (25% to 100%) at maturity. In both groups of patients the under-correction was significantly reduced between six months post-operatively and skeletal maturity. The overall rate of revision was 18% (eight patients), and seven of these revisions (87.5%) involved the tibia. This series showed that use of the PETS technique in the femur was safe, but that its use in the tibia was associated with a significant rate of complications, including a valgus deformity in nine patients (20%), leading us to abandon it in the tibia. The arrest of growth was delayed and the final loss of growth at maturity was only 66% of that predicted pre-operatively. This should be taken into account in the pre-operative planning


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1643 - 1646
1 Dec 2005
Miura H Matsuda S Okazaki K Kawano T Kawamura H Iwamoto Y

We have previously developed a radiographic technique, the oblique posterior condylar view, for assessment of the posterior aspect of the femoral condyles after total knee arthroplasty. The purpose of this study was to confirm the validity of this radiographic view based upon intra-operative findings at revision total knee arthroplasty. Lateral and oblique posterior condylar views were performed for 11 knees prior to revision total knee arthroplasty, and radiolucent lines or osteolysis of the posterior aspect of the femoral condyles were identified. These findings were compared with the intra-operative appearance of the posterior aspects of the femoral condyles. Statistical analysis showed that sensitivity and efficacy were significantly better for the oblique posterior condylar than the lateral view. This method can, therefore, be considered as suitable for routine follow-up radiographs of the femoral component and in the pre-operative planning of revision surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1520 - 1523
1 Nov 2005
Attias N Lindsey RW Starr AJ Borer D Bridges K Hipp JA

We created virtual three-dimensional reconstruction models from computed tomography scans obtained from patients with acetabular fractures. Virtual cylindrical implants were placed intraosseously in the anterior column, the posterior column and across the dome of the acetabulum. The maximum diameter which was entirely contained within the bone was determined for each position of the screw. In the same model, the cross-sectional diameters of the columns were measured and compared to the maximum diameter of the corresponding virtual implant. We found that the mean maximum diameter of virtual implant accommodated by the anterior columns was 6.4 mm and that the smallest diameter of the columns was larger than the maximum diameter of the equivalent virtual implant. This study suggests that the size of the screw used for percutaneous fixation of acetabular fractures should not be based solely on the measurement of cross-sectional diameter and that virtual three-dimensional reconstructions might be useful in pre-operative planning


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 510 - 515
1 Apr 2007
Watts AC Morris A Robinson CM

Fractures of the distal humeral articular surface which do not involve the medial and lateral columns are often more extensive than is apparent from plain radiographs. This retrospective study describes the epidemiology of this injury using modern classification systems and compares pre-operative radiography with operative findings. The study group included 79 patients with a mean age of 47 years (13 to 91). The annual incidence was 1.5 per 100 000 population, and was highest in women over the age of 60. The majority of the fractures (59; 75%) were sustained in falls from standing height. Young males tended to sustain more high-energy injuries with more complex fracture patterns. In 24% of cases (19) there was a concomitant radial head fracture. Classification from plain radiographs often underestimates the true extent of the injury and computed tomography may be of benefit in pre-operative planning, especially in those over 60 years of age


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 374 - 380
1 Mar 2016
Kocsis G Thyagarajan DS Fairbairn KJ Wallace WA

Aims. Glenoid bone loss can be a challenging problem when revising a shoulder arthroplasty. Precise pre-operative planning based on plain radiographs or CT scans is essential. We have investigated a new radiological classification system to describe the degree of medialisation of the bony glenoid and that will indicate the amount of bone potentially available for supporting a glenoid component. It depends on the relationship between the most medial part of the articular surface of the glenoid with the base of the coracoid process and the spinoglenoid notch: it classifies the degree of bone loss into three types. It also attempts to predict the type of glenoid reconstruction that may be possible (impaction bone grafting, structural grafting or simple non-augmented arthroplasty) and gives guidance about whether a pre-operative CT scan is indicated. Patients and Methods. Inter-method reliability between plain radiographs and CT scans was assessed retrospectively by three independent observers using data from 39 randomly selected patients. . Inter-observer reliability and test-retest reliability was tested on the same cohort using Cohen's kappa statistics. Correlation of the type of glenoid with the Constant score and its pain component was analysed using the Kruskal-Wallis method on data from 128 patients. Anatomical studies of the scapula were reviewed to explain the findings. Results. Excellent inter-method reliability, inter-observer and test-retest reliability were seen. The system did not correlate with the Constant score, but correlated well with its pain component. . Take home message: Our system of classification is a helpful guide to the degree of glenoid bone loss when embarking on revision shoulder arthroplasty. Cite this article: Bone Joint J 2016;98-B:374–80


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1275 - 1279
1 Sep 2013
Liu T Liu Z Zhang Q Zhang X

The aim of this study was to assess a specific protocol for the treatment of patients with a parosteal osteosarcoma of the distal femur with limb salvage involving hemicortical resection and reconstruction using recycled pasteurised autograft and internal fixation. Between January 2000 and January 2010, 13 patients with a mean age of 26.5 years (17 to 39) underwent this procedure. All the tumours were staged according to Enneking’s criteria: there were eight stage IA tumours and five stage IB tumours. The mean follow-up was 101.6 months (58 to 142), and mean post-operative Musculoskeletal Tumour Society functional score was 88.6% (80% to 100%) at the final follow-up. All the patients had achieved bony union; the mean time to union was 11.2 months (6 to 18). Local recurrence occurred in one patient 27 months post-operatively. No patient had a pulmonary metastasis. A hemicortical procedure for the treatment of a parosteal osteosarcoma is safe and effective. Precise pre-operative planning using MRI is essential in order to define the margins of resection. Although it is a technically demanding procedure, gratifying results make it worthwhile for selected patients. Cite this article: Bone Joint J 2013;95-B:1275–9


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 247 - 250
1 Mar 1988
Lowrie I Finlay D Brenkel I Gregg P

Thirty-six patients with 39 fresh fractures of the calcaneus were investigated by standard radiography and by computerised tomography. It was found that the size and disposition of the fracture fragments and the degree of involvement of the posterior facet of the subtalar joint were more clearly shown by CT scanning. We recommend this technique for assessment and particularly for pre-operative planning


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 43 - 46
1 Jan 1989
Dias J Johnson G Finlay D Stoyle T

We have studied the role of computerised axial tomography in the assessment of the acetabulum before an uncemented Mittelmeier arthroplasty was performed in 20 patients. In the absence of gross anatomical abnormality, computerised tomography did not provide additional information, but in eight patients it was useful in determining adequacy of acetabular depth, anterior acetabular cover, and thickness of the anterior and posterior walls. In these patients, the CT scans provided information which was not available from plain radiographs and greatly assisted in pre-operative planning


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 927 - 931
1 Nov 1991
Ogata K Yoshii I Kawamura H Miura H Arizono T Sugioka Y

The use of standing radiographs to determine correction angles for high tibial osteotomy is not appropriate because the relative angle of the articular surfaces (condylar-plateau angle) in the weight-bearing knee changes after the osteotomy. This may give unpredictable results postoperatively. We found that the condylar-plateau angle in postoperative standing films is very similar to that seen in non-weight-bearing supine views, and suggest that these latter radiographs be used for pre-operative planning. We describe our early results, using a special osteotomy jig, in 140 knees


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 205 - 211
1 Mar 1990
Paavilainen T Hoikka V Solonen K

We report the short-term results of 100 cementless total hip replacements in 52 severely dysplastic and 48 totally dislocated hips, with some new technical solutions to the problems involved. In cases with a very narrow iliac bone, the acetabular screw ring is seated below the true cotyloid area. In hips with tight flexor and abductor muscles or with deformities of the proximal femur, various osteotomies were performed. Special attention was paid to careful pre-operative planning and precise operative technique. In spite of a high complication rate the results were generally good and even patients who required reoperation were satisfied with the final result


Bone & Joint 360
Vol. 9, Issue 4 | Pages 15 - 17
1 Aug 2020


Bone & Joint Open
Vol. 1, Issue 5 | Pages 152 - 159
22 May 2020
Oommen AT Chandy VJ Jeyaraj C Kandagaddala M Hariharan TD Arun Shankar A Poonnoose PM Korula RJ

Aims

Complex total hip arthroplasty (THA) with subtrochanteric shortening osteotomy is necessary in conditions other than developmental dysplasia of the hip (DDH) and septic arthritis sequelae with significant proximal femur migration. Our aim was to evaluate the hip centre restoration with THAs in these hips.

Methods

In all, 27 THAs in 25 patients requiring THA with femoral shortening between 2012 and 2019 were assessed. Bilateral shortening was required in two patients. Subtrochanteric shortening was required in 14 out of 27 hips (51.9%) with aetiology other than DDH or septic arthritis. Vertical centre of rotation (VCOR), horizontal centre of rotation, offset, and functional outcome was calculated. The mean followup was 24.4 months (5 to 92 months).


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 965 - 966
1 Aug 2020
Haddad FS Plastow R


Bone & Joint 360
Vol. 9, Issue 4 | Pages 41 - 44
1 Aug 2020


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 664 - 670
1 Jun 2020
Wyatt MC Kunutsor SK Beswick AD Whitehouse MR Kieser DC

Aims

There is inconsistent evidence on whether prior spinal fusion surgery adversely impacts outcomes following total hip arthroplasty (THA). We conducted a systematic review and meta-analysis to assess the association between pre-existing spinal fusion surgery and the rate of complications following primary THA.

Methods

We searched MEDLINE, Embase, Web of Science, and Cochrane Library up to October 2019 for randomized controlled trials (RCTs) and observational studies comparing outcomes of dislocation, revision, or reasons for revision in patients following primary THA with or without pre-existing spinal fusion surgery. Furthermore, we compared short (two or less levels) or long (three or more levels) spinal fusions to no fusion. Summary measures of association were relative risks (RRs) (with 95% confidence intervals (CIs)).


Bone & Joint Research
Vol. 6, Issue 3 | Pages 137 - 143
1 Mar 2017
Cho HS Park YK Gupta S Yoon C Han I Kim H Choi H Hong J

Objectives

We evaluated the accuracy of augmented reality (AR)-based navigation assistance through simulation of bone tumours in a pig femur model.

Methods

We developed an AR-based navigation system for bone tumour resection, which could be used on a tablet PC. To simulate a bone tumour in the pig femur, a cortical window was made in the diaphysis and bone cement was inserted. A total of 133 pig femurs were used and tumour resection was simulated with AR-assisted resection (164 resection in 82 femurs, half by an orthropaedic oncology expert and half by an orthopaedic resident) and resection with the conventional method (82 resection in 41 femurs). In the conventional group, resection was performed after measuring the distance from the edge of the condyle to the expected resection margin with a ruler as per routine clinical practice.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 872 - 879
1 Jul 2017
Li Y Zhang X Wang Q Peng X Wang Q Jiang Y Chen Y

Aims

There is no consensus about the best method of achieving equal leg lengths at total hip arthroplasty (THA) in patients with Crowe type-IV developmental dysplasia of the hip (DDH). We reviewed our experience of a consecutive series of patients who underwent THA for this indication.

Patients and Methods

We retrospectively reviewed 78 patients (86 THAs) with Crowe type-IV DDH, including 64 women and 14 men, with a minimum follow-up of two years. The mean age at the time of surgery was 52.2 years (34 to 82). We subdivided Crowe type-IV DDH into two major types according to the number of dislocated hips, and further categorised them into three groups according to the occurrence of pelvic obliquity or spinal curvature. Leg length discrepancy (LLD) and functional scores were analysed.


Bone & Joint Research
Vol. 6, Issue 11 | Pages 631 - 639
1 Nov 2017
Blyth MJG Anthony I Rowe P Banger MS MacLean A Jones B

Objectives

This study reports on a secondary exploratory analysis of the early clinical outcomes of a randomised clinical trial comparing robotic arm-assisted unicompartmental knee arthroplasty (UKA) for medial compartment osteoarthritis of the knee with manual UKA performed using traditional surgical jigs. This follows reporting of the primary outcomes of implant accuracy and gait analysis that showed significant advantages in the robotic arm-assisted group.

Methods

A total of 139 patients were recruited from a single centre. Patients were randomised to receive either a manual UKA implanted with the aid of traditional surgical jigs, or a UKA implanted with the aid of a tactile guided robotic arm-assisted system. Outcome measures included the American Knee Society Score (AKSS), Oxford Knee Score (OKS), Forgotten Joint Score, Hospital Anxiety Depression Scale, University of California at Los Angeles (UCLA) activity scale, Short Form-12, Pain Catastrophising Scale, somatic disease (Primary Care Evaluation of Mental Disorders Score), Pain visual analogue scale, analgesic use, patient satisfaction, complications relating to surgery, 90-day pain diaries and the requirement for revision surgery.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 261 - 266
1 Feb 2017
Laitinen MK Parry MC Albergo JI Grimer RJ Jeys LM

Aims

Due to the complex anatomy of the pelvis, limb-sparing resections of pelvic tumours achieving adequate surgical margins, can often be difficult. The advent of computer navigation has improved the precision of resection of these lesions, though there is little evidence comparing resection with or without the assistance of navigation.

Our aim was to evaluate the efficacy of navigation-assisted surgery for the resection of pelvic bone tumours involving the posterior ilium and sacrum.

Patients and Methods

Using our prospectively updated institutional database, we conducted a retrospective case control study of 21 patients who underwent resection of the posterior ilium and sacrum, for the treatment of a primary sarcoma of bone, between 1987 and 2015. The resection was performed with the assistance of navigation in nine patients and without navigation in 12. We assessed the accuracy of navigation-assisted surgery, as defined by the surgical margin and how this affects the rate of local recurrence, the disease-free survival and the effects on peri-and post-operative morbidity.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1157 - 1166
1 Sep 2017
Nerhus TK Ekeland A Solberg G Olsen BH Madsen JE Heir S

Aims

The aim of this prospective randomised study was to compare the time course of clinical improvement during the first two years following a closing or opening wedge high tibial osteotomy (HTO). It was hypothesised that there would be no differences in clinical outcome between the two techniques.

Patients and Methods

Between 2007 and 2013, 70 consecutive patients were randomly allocated to undergo either a closing or opening wedge HTO. All patients had medial compartment osteoarthritis (OA), and were aged between 30 years and 60 years. They were evaluated by independent investigators pre-operatively and at three and six months, and one and two years post-operatively using the Knee Injury and Osteoarthritis Outcome Score (KOOS), the Oxford Knee Score (OKS), the Lysholm score, the Tegner activity score, the University of California, Los Angeles (UCLA) activity scale and range of movement (ROM).


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 724 - 731
1 Jun 2017
Mei-Dan O Jewell D Garabekyan T Brockwell J Young DA McBryde CW O’Hara JN

Aims

The aim of this study was to evaluate the long-term clinical and radiographic outcomes of the Birmingham Interlocking Pelvic Osteotomy (BIPO).

Patients and Methods

In this prospective study, we report the mid- to long-term clinical outcomes of the first 100 consecutive patients (116 hips; 88 in women, 28 in men) undergoing BIPO, reflecting the surgeon’s learning curve. Failure was defined as conversion to hip arthroplasty. The mean age at operation was 31 years (7 to 57). Three patients (three hips) were lost to follow-up.


Bone & Joint 360
Vol. 6, Issue 6 | Pages 17 - 20
1 Dec 2017


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 231 - 236
1 Feb 2017
Wagener J Gross CE Schweizer C Lang TH Hintermann B

Aims

A failed total ankle arthroplasty (TAA) is often associated with much bone loss. As an alternative to arthrodesis, the surgeon may consider a custom-made talar component to compensate for the bone loss. Our aim in this study was to assess the functional and radiological outcome after the use of such a component at mid- to long-term follow-up.

Patients and Methods

A total of 12 patients (five women and seven men, mean age 53 years; 36 to77) with a failed TAA and a large talar defect underwent a revision procedure using a custom-made talar component. The design of the custom-made components was based on CT scans and standard radiographs, when compared with the contralateral ankle. After the anterior talocalcaneal joint was fused, the talar component was introduced and fixed to the body of the calcaneum.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 786 - 792
1 Jun 2016
Schotanus MGM Sollie R van Haaren EH Hendrickx RPM Jansen EJP Kort NP

Aims

This prospective randomised controlled trial was designed to evaluate the outcome of both the MRI- and CT-based patient-specific matched guides (PSG) from the same manufacturer.

Patients and Methods

A total of 137 knees in 137 patients (50 men, 87 women) were included, 67 in the MRI- and 70 in the CT-based PSG group. Their mean age was 68.4 years (47.0 to 88.9). Outcome was expressed as the biomechanical limb alignment (centre hip-knee-ankle: HKA-axis) achieved post-operatively, the position of the individual components within 3° of the pre-operatively planned alignment, correct planned implant size and operative data (e.g. operating time and blood loss).


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1435 - 1441
1 Nov 2017
Buttaro MA Oñativia JI Slullitel PA Andreoli M Comba F Zanotti G Piccaluga F

Aims

The Corail stem has good long-term results. After four years of using this stem, we have detected a small group of patients who have presented with symptomatic metaphyseal debonding. The aim of this study was to quantify the incidence of this complication, to delineate the characteristics of patients presenting with this complication and to compare these patients with asymptomatic controls to determine any important predisposing factors.

Patients and Methods

Of 855 Corail collarless cementless stems implanted for osteoarthritis, 18 presented with symptomatic metaphyseal debonding. A control group of 74 randomly selected patients was assembled. Clinical and radiological parameters were measured and a logistic regression model was created to evaluate factors associated with metaphyseal debonding.


Bone & Joint Research
Vol. 5, Issue 7 | Pages 280 - 286
1 Jul 2016
Ozkurt B Sen T Cankaya D Kendir S Basarır K Tabak Y

Objectives

The purpose of this study was to develop an accurate, reliable and easily applicable method for determining the anatomical location of the joint line during revision knee arthroplasty.

Methods

The transepicondylar width (TEW), the perpendicular distance between the medial and lateral epicondyles and the distal articular surfaces (DMAD, DLAD) and the distance between the medial and lateral epicondyles and the posterior articular surfaces (PMAD, DLAD) were measured in 40 knees from 20 formalin-fixed adult cadavers (11 male and nine female; mean age at death 56.9 years, sd 9.4; 34 to 69). The ratios of the DMAD, PMAD, DLAD and PLAD to TEW were calculated.


Bone & Joint Research
Vol. 6, Issue 8 | Pages 522 - 529
1 Aug 2017
Ali AM Newman SDS Hooper PA Davies CM Cobb JP

Objectives

Unicompartmental knee arthroplasty (UKA) is a demanding procedure, with tibial component subsidence or pain from high tibial strain being potential causes of revision. The optimal position in terms of load transfer has not been documented for lateral UKA. Our aim was to determine the effect of tibial component position on proximal tibial strain.

Methods

A total of 16 composite tibias were implanted with an Oxford Domed Lateral Partial Knee implant using cutting guides to define tibial slope and resection depth. Four implant positions were assessed: standard (5° posterior slope); 10° posterior slope; 5° reverse tibial slope; and 4 mm increased tibial resection. Using an electrodynamic axial-torsional materials testing machine (Instron 5565), a compressive load of 1.5 kN was applied at 60 N/s on a meniscal bearing via a matching femoral component. Tibial strain beneath the implant was measured using a calibrated Digital Image Correlation system.