Aims. A recent report from France suggested an association between the use of cobalt-chrome (CoCr) femoral heads in
Aims. Iliopsoas pathology is a relatively uncommon cause of pain following
Aims. Previous research has demonstrated increased early complication rates following
Objectives. Our study aimed to examine not only the incidence but also the
impact of noise from two types of
Aims. Periprosthetic joint infection (PJI) remains a challenging complication
following
The outcome after
Aims. We assessed the difference in hospital based and early clinical
outcomes between the direct anterior approach and the posterior
approach in patients who undergo
The timing of
Several factors have been implicated in unsatisfactory
results after
Down’s syndrome is associated with a number of
musculoskeletal abnormalities, some of which predispose patients
to early symptomatic arthritis of the hip. The purpose of the present
study was to review the general and hip-specific factors potentially
compromising
Restoration of leg length and offset is an important
goal in
It has been suggested that cemented fixation of total hip arthroplasty
(THA) is associated with an increased peri-operative mortality compared
with cementless THA. Our aim was to investigate this through a nationwide
matched cohort study adjusting for age, comorbidity, and socioeconomic
background. A total of 178 784 patients with osteoarthritis who underwent
either cemented or cementless THA from the Swedish Hip Arthroplasty
Register were matched with 862 294 controls from the general population.
Information about the causes of death, comorbidities, and socioeconomic
background was obtained. Mortality within the first 90 days after
the operation was the primary outcome measure.Aims
Patients and Methods
Large-head metal-on-metal (MoM) total hip replacements
(THR) have given rise to concern. Comparative studies of small-head
MoM THRs over a longer follow-up period are lacking. Our objective
was to compare the incidence of complications such as infection,
dislocation, revision, adverse local tissue reactions, mortality
and radiological and clinical outcomes in small-head (28 mm) MoM
and ceramic-on-polyethylene (CoP) THRs up to 12 years post-operatively. A prospective cohort study included 3341 THRs in 2714 patients.
The mean age was 69.1 years (range 24 to 98) and 1848 (55.3%) were
performed in women, with a mean follow-up of 115 months (18 to 201).
There were 883 MoM and 2458 CoP bearings. Crude incidence rates
(cases/1000 person-years) were: infection 1.3 In conclusion, we found similar results for small-head MoM and
CoP bearings up to ten years post-operatively, but after ten years
MoM THRs had a higher risk of all-cause revision. Furthermore, the
presence of an adverse response to metal debris seen in the small-head
MOM group at revision is a cause for concern. Cite this article:
Between 1999 and 2001, 90 patients underwent
total hip replacement using the same uncemented acetabular and femoral
components with a 28 mm metallic femoral head but with prospective
randomisation of the acetabular liner to either Durasul highly cross-linked
polyethylene or nitrogen-sterilised Sulene polyethylene. We assessed
83 patients at a minimum follow-up of ten years. Linear penetration
of the femoral head was estimated at six weeks, six and 12 months
and annually thereafter, using the Dorr method, given the non-spherical
shape of the acetabular component. There was no loosening of any component; only one hip in the
Sulene group showed proximal femoral osteolysis. The mean penetration
of the femoral head at six weeks was 0.08 mm (0.02 to 0.15) for
the Durasul group and 0.16 mm (0.05 to 0.28) for the Sulene group
(p = 0.001). The mean yearly linear penetration was 64.8% lower
for the Durasul group at 0.05 mm/year ( Cite this article:
Aims.
Aims. Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in
Aims. Recent improvements in surgical technique and perioperative blood management after total joint replacement (TJR) have decreased rates of transfusion. However, as many surgeons transition to outpatient TJR, obtaining routine postoperative blood tests becomes more challenging. Therefore, we sought to determine if a preoperative outpatient assessment tool that stratifies patients based on numerous medical comorbidities could predict who required postoperative haemoglobin (Hb) measurement. Methods. We performed a prospective study of consecutive unilateral primary total knee arthroplasties (TKAs) and
We aim to evaluate the usefulness of postoperative blood tests by investigating the incidence of abnormal results following total joint replacement (TJR), as well as identifying preoperative risk factors for abnormal blood test results postoperatively, especially pertaining to anaemia and acute kidney injury (AKI). This is a retrospective cohort study of patients who had elective TJR between January and December 2019 at a tertiary centre. Data gathered included age at time of surgery, sex, BMI, American Society of Anesthesiologists (ASA) grade, preoperative and postoperative laboratory test results, haemoglobin (Hgb), white blood count (WBC), haematocrit (Hct), platelets (Plts), sodium (Na+), potassium (K+), creatinine (Cr), estimated glomerular filtration rate (eGFR), and Ferritin (ug/l). Abnormal blood tests, AKI, electrolyte imbalance, anaemia, transfusion, reoperation, and readmission within one year were reported.Aims
Methods
Aims. The primary objective of this study was to develop a validated classification system for assessing iatrogenic bone trauma and soft-tissue injury during
Aims. Iliopsoas impingement occurs in 4% to 30% of patients after undergoing
Aims. Conventional patient-reported surveys, used for patients undergoing
Aims.
Aims. In 2015, we published the results of our ceramic-on-metal (CoM)
Aims. This study aimed to describe practice variation in the use of
Aims. Manual impaction, with a mallet and introducer, remains the standard method of installing cementless acetabular cups during
Aims. The aim of this study was to evaluate the survival of a collarless, straight, hydroxyapatite-coated femoral stem in
Aims. A significant reduction in wear at five and ten years was previously reported when comparing Durasul highly cross-linked polyethylene with nitrogen-sterilized Sulene polyethylene in
Aims. Leg length discrepancy (LLD) is a common pre- and postoperative issue in
Aims. Femoral component anteversion is an important factor in the success of
Aims. The aim of this study was to explore the functional results in a fitter subgroup of participants in the Hip Fracture Evaluation with Alternatives of
Aims. Implant waste during
Aims. Professional dancers represent a unique patient population in the setting of hip arthroplasty, given the high degree of hip strength and mobility required by their profession. We sought to determine the clinical outcomes and ability to return to professional dance after
Aims. The aims of this systematic review were to assess the learning curve of semi-active robotic arm-assisted
Aims. Computer-assisted 3D preoperative planning software has the potential to improve postoperative stability in
Aims. This study aimed to assess the carbon footprint associated with
Aims. Young adults undergoing
Aims. Postoperative length of stay (LOS) and discharge dispositions following arthroplasty can be used as surrogate measurements for improvements in patients’ pathways and costs. With the increasing use of robotic technology in arthroplasty, it is important to assess its impact on LOS. The aim of this study was to identify factors associated with decreased LOS following robotic arm-assisted
Aims. The aim of this study was to evaluate the suitability of the tapered cone stem in
Aims. Obesity is associated with an increased risk of hip osteoarthritis, resulting in an increased number of
Aims. The aim of this study was to evaluate the reliability and validity of a patient-specific algorithm which we developed for predicting changes in sagittal pelvic tilt after
Aims. The aim of this study was to compare the early postoperative mortality and morbidity in older patients with a fracture of the femoral neck, between those who underwent
Aims. For displaced femoral neck fractures (FNFs) in geriatric patients, there remains uncertainty regarding the effect of
Aims. Osteoporosis is common in
Aims. A revision for periprosthetic joint infection (PJI) in
Aims. Adult patients with history of childhood infection pose a surgical challenge for
Aims. The prevalence of obesity is increasing substantially around the world. Elevated BMI increases the risk of complications following
Aims. Excessive posterior pelvic tilt (PT) may increase the risk of anterior instability after
Aims. The volume of ambulatory
Aims. Mechanical impingement of the iliopsoas (IP) tendon accounts for 2% to 6% of persistent postoperative pain after