Aims. This study aimed to describe the use of revision
We compared thromboembolic events, major haemorrhage
and death after
Bone loss in the proximal tibia and distal femur
is frequently encountered in revision
We present a comparison of patient-reported outcomes
(PROMs) in relation to patient age, in patients who had received
a total (TKR) or unicompartmental knee replacement (UKR). The outcome
was evaluated using the Oxford knee score (OKS), EuroQol (EQ-5D)
and satisfaction scores. Patients aged 65 to 84 years demonstrated
better pre-operative function scores than those aged <
65 years
(OKS, p = 0.03; EQ-5D, p = 0.048) and those aged
≥ 85 years (OKS, p = 0.03). Post-operative scores were comparable
across age groups, but a linear trend for greater post-operative
improvement in OKS and EQ-5D was seen with decreasing age (p <
0.033). The overall mean satisfaction score at six months was 84.9,
but those aged <
55 years exhibited a lower mean level of satisfaction (78.3)
compared with all other age groups (all p <
0.031). The cumulative
overall two-year revision rate was 1.3%. This study demonstrates
that good early outcomes, as measured by the OKS and EQ-5D, can
be anticipated following
Aims. To assess the cost-effectiveness of a two-layer compression bandage versus a standard wool and crepe bandage following total knee arthroplasty, using patient-level data from the
Aims. Approximately 10% to 20% of
Aims. The aim of this study was to determine the risk of tibial eminence avulsion intraoperatively for bi-unicondylar
Cementless
Aims. The metabolic equivalent of task (MET) score examines patient performance in relation to energy expenditure before and after
Aims. The aim of this study was to identify variables associated with time to revision, demographic details associated with revision indication, and type of prosthesis employed, and to describe the survival of hinge
Aims. To map the Oxford Knee Score (OKS) and High Activity Arthroplasty Score (HAAS) items to a common scale, and to investigate the psychometric properties of this new scale for the measurement of knee health. Methods. Patient-reported outcome measure (PROM) data measuring knee health were obtained from the NHS PROMs dataset and Total or Partial Knee Arthroplasty Trial (TOPKAT). Assumptions for common scale modelling were tested. A graded response model (fitted to OKS item responses in the NHS PROMs dataset) was used as an anchor to calibrate paired HAAS items from the TOPKAT dataset. Information curves for the combined OKS-HAAS model were plotted. Bland-Altman analysis was used to compare common scale scores derived from OKS and HAAS items. A conversion table was developed to map between HAAS, OKS, and the common scale. Results. We included 3,329 response sets from 528 patients undergoing
Aims. The James Lind Alliance aims to bring patients, carers, and clinicians together to identify uncertainties regarding care. A Priority Setting Partnership was established by the British Association for Surgery of the Knee in conjunction with the James Lind Alliance to identify research priorities related to the assessment, management, and rehabilitation of patients with persistent symptoms after
Aims. To estimate the measurement properties for the Oxford Knee Score (OKS) in patients undergoing revision
Aims. Hereditary haemochromatosis is a genetic disorder that is caused by several known mutations in the human homeostatic iron regulator protein (HFE) gene. Abnormal accumulation of iron causes a joint disease that resembles osteoarthritis (OA), but appears at a relatively younger age and is accompanied by cirrhosis, diabetes, and injury to other organs. Increased serum transferrin saturation and ferritin levels are known markers of haemochromatosis with high positive predictive values. Methods. We have retrospectively analyzed the iron studies of a cohort of 2,035 patients undergoing knee joint arthroplasty due to OA. Results. No patients had HFE gene C282Y, S65C, or H63D mutations testing. In total, 18 patients (2.96%) of the male cohort and 51 (3.58%) of the female cohort had pathologically increased ferritin levels that may be indicative of haemochromatosis. Seven patients (0.34%) had serum transferrin saturation above 45%. Conclusion. The awareness for the diagnosis of this disorder in Orthopaedics is low and needs improvement. Osteoarthritic patients undergoing
Aims. The purpose of this study was to develop a personalized outcome prediction tool, to be used with
Aims. Recent studies have suggested that corticosteroid injections into the knee may harm the joint resulting in cartilage loss and possibly accelerating the progression of osteoarthritis (OA). The aim of this study was to assess whether patients with, or at risk of developing, symptomatic osteoarthritis of the knee who receive intra-articular corticosteroid injections have an increased risk of requiring arthroplasty. Methods. We used data from the Osteoarthritis Initiative (OAI), a multicentre observational cohort study that followed 4,796 patients with, or at risk of developing, osteoarthritis of the knee on an annual basis with follow-up available up to nine years. Increased risk for symptomatic OA was defined as frequent knee symptoms (pain, aching, or stiffness) without radiological evidence of OA and two or more risk factors, while OA was defined by the presence of both femoral osteophytes and frequent symptoms in one or both knees. Missing data were imputed with multiple imputations using chained equations. Time-dependent propensity score matching was performed to match patients at the time of receving their first injection with controls. The effect of corticosteroid injections on the rate of subsequent (total and partial)
Aims. Achievement of accurate microbiological diagnosis prior to revision is key to reducing the high rates of persistent infection after revision knee surgery. The effect of change in the microorganism between the first- and second-stage revision of total knee arthroplasty for periprosthetic joint infection (PJI) on the success of management is not clear. Methods. A two-centre retrospective cohort study was conducted to review the outcome of patients who have undergone two-stage revision for treatment of
Aims. The aim of this study was to determine the long-term risk of undergoing
Treatment of end-stage anteromedial osteoarthritis (AMOA) of the knee is commonly approached using one of two surgical strategies: medial unicompartmental knee arthroplasty (UKA) or total knee arthroplasty (TKA). In this study we aim to investigate if there is any difference in outcome for patients undergoing UKA or TKA, when treated by high-volume surgeons, in high-volume centres, using two different clinical guidelines. The two strategies are ‘UKA whenever possible’ vs TKA for all patients with AMOA. A total of 501 consecutive AMOA patients (301 UKA) operated on between 2013 to 2016 in two high-volume centres were included. Centre One employed clinical guidelines for the treatment of AMOA allowing either UKA or TKA, but encouraged UKA wherever possible. Centre Two used clinical guidelines that treated all patients with a TKA, regardless of wear pattern. TKA patients were included if they had isolated AMOA on preoperative radiographs. Data were collected from both centres’ local databases. The primary outcome measure was change in Oxford Knee Score (OKS), and the proportion of patients achieving the patient-acceptable symptom state (PASS) at one-year follow-up. The data were 1:1 propensity score matched before regression models were used to investigate potential differences.Aims
Methods
Aims. The aim of this study was to determine the long-term mortality rate, and to identify factors associated with this, following primary and revision
Aims. The aim of this study was to compare any differences in the primary outcome (biphasic flexion knee moment during gait) of robotic arm-assisted bi-unicompartmental
Aims. To compare rates of serious adverse events in patients undergoing revision
Aims. The aim of this study was to compare the clinical outcomes of robotic arm-assisted bi-unicompartmental
Intraoperative pressure sensors allow surgeons to quantify soft-tissue balance during total knee arthroplasty (TKA). The aim of this study was to determine whether using sensors to achieve soft-tissue balance was more effective than manual balancing in improving outcomes in TKA. A multicentre randomized trial compared the outcomes of sensor balancing (SB) with manual balancing (MB) in 250 patients (285 TKAs). The primary outcome measure was the mean difference in the four Knee injury and Osteoarthritis Outcome Score subscales (ΔKOOS4) in the two groups, comparing the preoperative and two-year scores. Secondary outcomes included intraoperative balance data, additional patient-reported outcome measures (PROMs), and functional measures.Aims
Methods
Mobile-bearing posterior-stabilised
Periprosthetic joint infection (PJI) is a challenging complication of any arthroplasty procedure. We reviewed our use of static antibiotic-loaded cement spacers (ABLCSs) for staged management of PJI where segmental bone loss, ligamentous instability, or soft-tissue defects necessitate a static construct. We reviewed factors contributing to their failure and techniques to avoid these complications when using ABLCSs in this context. A retrospective analysis was conducted of 94 patients undergoing first-stage revision of an infected knee prosthesis between September 2007 and January 2020 at a single institution. Radiographs and clinical records were used to assess and classify the incidence and causes of static spacer failure. Of the 94 cases, there were 19 primary total knee arthroplasties (TKAs), ten revision TKAs (varus-valgus constraint), 20 hinged TKAs, one arthrodesis (nail), one failed spacer (performed elsewhere), 21 distal femoral endoprosthetic arthroplasties, and 22 proximal tibial arthroplasties.Aims
Methods
To perform an incremental cost-utility analysis and assess the impact of differential costs and case volume on the cost-effectiveness of robotic arm-assisted unicompartmental knee arthroplasty (rUKA) compared to manual (mUKA). This was a five-year follow-up study of patients who were randomized to rUKA (n = 64) or mUKA (n = 65). Patients completed the EuroQol five-dimension questionnaire (EQ-5D) preoperatively, and at three months and one, two, and five years postoperatively, which was used to calculate quality-adjusted life years (QALYs) gained. Costs for the primary and additional surgery and healthcare costs were calculated.Aims
Methods
Popliteal artery injury (PAI) is a feared complication
during
Debate remains whether the patella should be resurfaced during total knee replacement (TKR). For non-resurfaced TKRs, we estimated what the revision rate would have been if the patella had been resurfaced, and examined the risk of re-revision following secondary patellar resurfacing. A retrospective observational study of the National Joint Registry (NJR) was performed. All primary TKRs for osteoarthritis alone performed between 1 April 2003 and 31 December 2016 were eligible (n = 842,072). Patellar resurfacing during TKR was performed in 36% (n = 305,844). The primary outcome was all-cause revision surgery. Secondary outcomes were the number of excess all-cause revisions associated with using TKRs without (versus with) patellar resurfacing, and the risk of re-revision after secondary patellar resurfacing.Aims
Methods
Aims. The aim of this study was to compare robotic arm-assisted bi-unicompartmental
Total knee arthroplasty (TKA) is a common and safe orthopaedic procedure. Zimmer Biomet's NexGen is the second most popular brand of implant used in the UK. The primary cause of revision after the first year is aseptic loosening. We present our experience of using this implant, with significant concerns around its performance with regards early aseptic loosening of the tibial component. A retrospective, single-surgeon review was carried out of all of the NexGen Legacy Posterior Stabilized (LPS) TKAs performed in this institute. The specific model used for the index procedures was the NexGen Complete Knee System (Legacy Knee-Posterior Stabilized LPS-Flex Articular Surface, LPS-Flex Femoral Component Option, and Stemmed Nonaugmentable Tibial Component Option).Aims
Methods
In the last decade, perioperative advancements have expanded the use of outpatient primary total knee arthroplasty (TKA). Despite this, there remains limited data on expedited discharge after revision TKA. This study compared 30-day readmissions and reoperations in patients undergoing revision TKA with a hospital stay greater or less than 24 hours. The authors hypothesized that expedited discharge in select patients would not be associated with increased 30-day readmissions and reoperations. Aseptic revision TKAs in the National Surgical Quality Improvement Program database were reviewed from 2013 to 2020. TKAs were stratified by length of hospital stay (greater or less than 24 hours). Patient demographic details, medical comorbidities, American Society of Anesthesiologists (ASA) grade, operating time, components revised, 30-day readmissions, and reoperations were compared. Multivariate analysis evaluated predictors of discharge prior to 24 hours, 30-day readmission, and reoperation.Aims
Methods
Aims. The treatment of patients with allergies to metal in total joint arthroplasty is an ongoing debate. Possibilities include the use of hypoallergenic prostheses, as well as the use of standard cobalt-chromium (CoCr) alloy. This non-designer study was performed to evaluate the clinical outcome and survival rates of unicondylar
The Swedish
Aims. The aim of this independent multicentre study was to assess the
mid-term results of mobile bearing unicondylar knee arthroplasty
(UKA) for isolated lateral osteoarthritis of the knee joint. Patients and Methods. We retrospectively evaluated 363 consecutive, lateral UKAs (346
patients) performed using the Oxford domed lateral prosthesis undertaken
in three high-volume
We present detailed information about early morbidity
after aseptic revision
Objectives. The purpose of this study was to develop an accurate, reliable and easily applicable method for determining the anatomical location of the joint line during revision
We have performed a prospective double-blind, randomised controlled trial over two years to evaluate the efficacy and safety of an intra-operative peri-articular injection of triamcinolone acetonide in patients undergoing medial unicondylar
The main objective of this study is to analyze the penetration of bone cement in four different full cementation techniques of the tibial tray. In order to determine the best tibial tray cementation technique, we applied cement to 40 cryopreserved donor tibiae by four different techniques: 1) double-layer cementation of the tibial component and tibial bone with bone restrictor; 2) metallic cementation of the tibial component without bone restrictor; 3) bone cementation of the tibia with bone restrictor; and 4) superficial bone cementation of the tibia and metallic keel cementation of the tibial component without bone restrictor. We performed CT exams of all 40 subjects, and measured cement layer thickness at both levels of the resected surface of the epiphysis and the endomedular metaphyseal level.Aims
Methods
Satisfaction is increasingly employed as an outcome
measure for a successful total knee replacement (TKR). Satisfaction
as an outcome measure encompasses many different intrinsic and extrinsic
factors related to a person’s experience before and after TKR. The
Swedish
Meeting preoperative expectations is known to be of major influence on postoperative satisfaction after total knee arthroplasty (TKA). Improved management of expectation, resulting in more realistic expectations can potentially lead to higher postoperative satisfaction. The objective of this study was to assess the effect of an additional preoperative education module, addressing realistic expectations for long-term functional recovery, on postoperative satisfaction and expectation fulfilment. In total, 204 primary TKA patients with osteoarthritis were enrolled in this randomized controlled trial (RCT). Patients were allocated to either usual preoperative education (control group) or usual education plus an additional module on realistic expectations (intervention group). Primary outcome was being very satisfied (numerical rating scale for satisfaction ≥ 8) with the treatment result at 12 months' follow-up. Other outcomes were change in preoperative expectations and postoperative expectation fulfilment.Aims
Methods
This study compared the cobalt and chromium serum ion concentration of patients treated with two different metal-on-metal (MoM) hinged total knee arthroplasty (TKA) systems, as well as a titanium nitride (TiN)-coated variant. A total of 63 patients (65 implants) were treated using either a MoM-coated (n = 29) or TiN-coated (n = 7) hinged TKA (GenuX mobile bearing, MUTARS; Implantcast, Germany) versus the BPKS (Brehm, Germany) hinged TKA (n = 27), in which the weight placed on the MoM hinge is diffused through a polyethylene (PE) inlay, reducing the direct load on the MoM hinge. Serum cobalt and chromium ion concentrations were assessed after minimum follow-up of 12 months, as well as functional outcome and quality of life.Aims
Methods
We have compared a new technique of computer-assisted
Stiffness is a common complication after total knee arthroplasty (TKA). Pathogenesis is not understood, treatment options are limited, and diagnosis is challenging. The aim of this study was to investigate if MRI can be used to visualize intra-articular scarring in patients with stiff, painful knee arthroplasties. Well-functioning primary TKAs (n = 11), failed non-fibrotic TKAs (n = 5), and patients with a clinical diagnosis of fibrosisAims
Methods
Aims
Materials and Methods
Patients with osteoarthritis undergoing
We assessed the effect of social deprivation
upon the Oxford knee score (OKS), the Short-Form 12 (SF-12) and patient
satisfaction after total knee replacement (TKR). An analysis of
966 patients undergoing primary TKR for symptomatic osteoarthritis
(OA) was performed. Social deprivation was assessed using the Scottish
Index of Multiple Deprivation. Those patients that were most deprived
underwent surgery at an earlier age (p = 0.018), were more likely
to be female (p = 0.046), to endure more comorbidities (p = 0.04)
and to suffer worse pain and function according to the OKS (p <
0.001). In addition, deprivation was also associated with poor mental
health (p = 0.002), which was assessed using the mental component
(MCS) of the SF-12 score. Multivariable analysis was used to identify
independent predictors of outcome at one year. Pre-operative OKS,
SF-12 MCS, back pain, and four or more comorbidities were independent
predictors of improvement in the OKS (all p <
0.001). Pre-operative
OKS and improvement in the OKS were independent predictors of dissatisfaction
(p = 0.003 and p <
0.001, respectively). Although improvement
in the OKS and dissatisfaction after TKR were not significantly
associated with social deprivation Cite this article:
To establish our early clinical results of a new total knee arthroplasty (TKA) tibial component introduced in 2013 and compare it to other designs in use at our hospital during the same period. This is a retrospective study of 166 (154 patients) consecutive cemented, fixed bearing, posterior-stabilized (PS) TKAs (ATTUNE) at one hospital performed by five surgeons. These were compared with a reference cohort of 511 knees (470 patients) of other designs (seven manufacturers) performed at the same hospital by the same surgeons. There were no significant differences in age, sex, BMI, or follow-up times between the two cohorts. The primary outcome was revision performed or pending.Aims
Methods
We carried out an audit on the result of achieving early walking in total knee replacement after instituting a new rehabilitation protocol, and assessed its influence on the development of deep-vein thrombosis as determined by Doppler ultrasound scanning on the fifth post-operative day. Early mobilisation was defined as beginning to walk less than 24 hours after
The radiolucent lines and the stability of the components of 66
Aims. The aim of this study was to determine if a three-month course of microorganism-directed oral antibiotics reduces the rate of failure due to further infection following two-stage revision for chronic prosthetic joint infection (PJI) of the hip and knee. Methods. A total of 185 patients undergoing a two-stage revision in seven different centres were prospectively enrolled. Of these patients, 93 were randomized to receive microorganism-directed oral antibiotics for three months following reimplantation; 88 were randomized to receive no antibiotics, and four were withdrawn before randomization. Of the 181 randomized patients, 28 were lost to follow-up, six died before two years follow-up, and five with culture negative infections were excluded. The remaining 142 patients were followed for a mean of 3.3 years (2.0 to 7.6) with failure due to a further infection as the primary endpoint. Patients who were treated with antibiotics were also assessed for their adherence to the medication regime and for side effects to antibiotics. Results. Nine of 72 patients (12.5%) who received antibiotics failed due to further infection compared with 20 of 70 patients (28.6%) who did not receive antibiotics (p = 0.012). Five patients (6.9%) in the treatment group experienced adverse effects related to the administered antibiotics severe enough to warrant discontinuation. Conclusion. This multicentre randomized controlled trial showed that a three-month course of microorganism-directed, oral antibiotics significantly reduced the rate of failure due to further infection following a two-stage revision of total hip or
Aims. Medial unicompartmental knee arthroplasty (UKA) is associated
with successful outcomes in carefully selected patient cohorts.
We hypothesised that severity and location of patellofemoral cartilage
lesions significantly influences functional outcome after Oxford
medial compartmental
Our study evaluated the accuracy of an image-guided total knee replacement system based on CT with regard to preparation of the femoral and tibial bone using nine limbs from five cadavers. The accuracy was assessed by direct measurement using an extramedullary alignment rod without radiographs. The mean angular errors of the femur and tibia, which represent angular gaps from the real mechanical axis in the coronal plane, were 0.3° and 1.1°, respectively. The CT-based system, provided almost perfect alignment of the femoral component with less than 1° of error and excellent alignment with less than 3° of error for the tibial component. Our results suggest that standardisation of
The Cementless Oxford Unicompartmental Knee Replacement
(OUKR) was developed to address problems related to cementation,
and has been demonstrated in a randomised study to have similar
clinical outcomes with fewer radiolucencies than observed with the
cemented device. However, before its widespread use it is necessary
to clarify contraindications and assess the complications. This
requires a larger study than any previously published. We present a prospective multicentre series of 1000 cementless
OUKRs in 881 patients at a minimum follow-up of one year. All patients
had radiological assessment aligned to the bone–implant interfaces
and clinical scores. Analysis was performed at a mean of 38.2 months
(19 to 88) following surgery. A total of 17 patients died (comprising
19 knees (1.9%)), none as a result of surgery; there were no tibial
or femoral loosenings. A total of 19 knees (1.9%) had significant
implant-related complications or required revision. Implant survival
at six years was 97.2%, and there was a partial radiolucency at
the bone–implant interface in 72 knees (8.9%), with no complete radiolucencies.
There was no significant increase in complication rate compared
with cemented fixation (p = 0.87), and no specific contraindications
to cementless fixation were identified. Cementless OUKR appears to be safe and reproducible in patients
with end-stage anteromedial osteoarthritis of the knee, with radiological
evidence of improved fixation compared with previous reports using
cemented fixation. Cite this article:
We carried out a prospective investigation into
the radiological outcomes of uncemented Oxford medial compartment
unicondylar replacement in 220 consecutive patients (231 knees)
performed in a single centre with a minimum two-year follow-up.
The functional outcomes using the mean Oxford knee score and the
mean high-activity arthroplasty score were significantly improved
over the pre-operative scores (p <
0.001). There were 196 patients
with a two-year radiological examination performed under fluoroscopic
guidance, aiming to provide images acceptable for analysis of the
bone–implant interface. Of the six tibial zones examined on each
knee on the anteroposterior radiograph, only three had a partial
radiolucent line. All were in the medial aspect of the tibial base plate
(zone 1) and all measured <
1 mm. All of these patients were
asymptomatic. There were no radiolucent lines seen around the femoral
component or on the lateral view. There was one revision for loosening
at one year due to initial inadequate seating of the tibial component.
These results confirm that the early uncemented Oxford medial unicompartmental
compartmental
Wear of polyethylene inserts plays an important role in failure
of total knee replacement and can be monitored Before revision, the minimum joint space width values and their
locations on the insert were measured in 15 fully weight-bearing
radiographs. These measurements were compared with the actual minimum
thickness values and locations of the retrieved tibial inserts after
revision. Introduction
Method
We have previously reported the short-term radiological
results of a randomised controlled trial comparing kinematically
aligned total knee replacement (TKR) and mechanically aligned TKR,
along with early pain and function scores. In this study we report
the two-year clinical results from this trial. A total of 88 patients
(88 knees) were randomly allocated to undergo either kinematically
aligned TKR using patient-specific guides, or mechanically aligned
TKR using conventional instruments. They were analysed on an intention-to-treat
basis. The patients and the clinical evaluator were blinded to the
method of alignment. At a minimum of two years, all outcomes were better for the kinematically
aligned group, as determined by the mean Oxford knee score (40 (15
to 48) In this study, the use of a kinematic alignment technique performed
with patient-specific guides provided better pain relief and restored
better function and range of movement than the mechanical alignment
technique performed with conventional instruments. Cite this article:
We report the five- to-ten year results of Anderson Orthopaedic Research Institute type-2 bone defects treated with modular metal augments in revision knee surgery. A total of 102 revision
This cohort study investigated the influence
of psychological factors, including perception of illness, anxiety
and depression on recovery and functional outcome after total knee
replacement surgery. A total of 100 patients (55 male; 45 female) with a mean age
of 71 (42 to 92) who underwent a primary total knee replacement
for osteoarthritis were recruited into this study. In all 97 participants
completed the six week and 87 the one year follow-up questionnaires. Pre-operatively patients completed the revised Illness Perception
Questionnaire, Hospital Anxiety and Depression Scale and Recovery
Locus of Control Scale. Function was assessed pre-operatively, at
six weeks and one year using Oxford Knee Score (OKS) and the goniometer-measured
range of movement (ROM). The results showed that pre-operative function had the biggest
impact on post-operative outcome for ROM and OKS. In addition questionnaire
variables and depression had an impact on the OKS at six weeks.
Depression and anxiety were also associated with a higher (worse)
knee score at one year but did not influence the ROM at either six weeks
or one year. Recovery from total knee replacement can be difficult to predict.
This study has identified psychological factors that play an important
role in recovery from surgery and functional outcome. These should
be taken into account when considering patients for total knee replacement. Cite this article:
The optimum cementing technique for the tibial
component in cemented primary total knee replacement (TKR) remains
controversial. The technique of cementing, the volume of cement
and the penetration are largely dependent on the operator, and hence
large variations can occur. Clinical, experimental and computational
studies have been performed, with conflicting results. Early implant
migration is an indication of loosening. Aseptic loosening is the
most common cause of failure in primary TKR and is the product of
several factors. Sufficient penetration of cement has been shown
to increase implant stability. This review discusses the relevant literature regarding all aspects
of the cementing of the tibial component at primary TKR. Cite this article:
Aims
Patients and Methods
Aims . To investigate whether pre-operative functional mobility is a
determinant of delayed inpatient recovery of activities (IRoA) after
total
We are entering a new era with governmental bodies
taking an increasingly guiding role, gaining control of registries,
demanding direct access with release of open public information
for quality comparisons between hospitals. This review is written
by physicians and scientists who have worked with the Swedish Knee
Arthroplasty Register (SKAR) periodically since it began. It reviews
the history of the register and describes the methods used and lessons
learned. Cite this article:
Knee joint distraction (KJD) is a relatively new, knee-joint
preserving procedure with the goal of delaying total knee arthroplasty
(TKA) in young and middle-aged patients. We present a randomised
controlled trial comparing the two. The 60 patients ≤ 65 years with end-stage knee osteoarthritis
were randomised to either KJD (n = 20) or TKA (n = 40). Outcomes
were assessed at baseline, three, six, nine, and 12 months. In the
KJD group, the joint space width (JSW) was radiologically assessed,
representing a surrogate marker of cartilage thickness.Aims
Patients and Methods
The purpose of this study was to compare outcomes of combined total joint arthroplasty (TJA) (total hip arthroplasty (THA) and total knee arthroplasty (TKA) performed during the same admission) versus bilateral THA, bilateral TKA, single THA, and single TKA. Combined TJAs performed on the same day were compared with those staged within the same admission episode. Data from the National (Nationwide) Inpatient Sample recorded between 2005 and 2014 were used for this retrospective cohort study. Postoperative in-hospital complications, total costs, and discharge destination were reviewed. Logistic and linear regression were used to perform the statistical analyses. p-values less than 0.05 were considered statistically significant.Aims
Patients and Methods
The practice of alternating operating theatres has long been used to reduce surgeon idle time between cases. However, concerns have been raised as to the safety of this practice. We assessed the payments and outcomes of total knee arthroplasty (TKA) performed during overlapping and nonoverlapping days, also comparing the total number of the surgeon’s cases and the total time spent in the operating theatre per day. A retrospective analysis was performed on the Centers for Medicare & Medicaid Services (CMS) Limited Data Set (LDS) on all primary elective TKAs performed at the New England Baptist Hospital between January 2013 and June 2016. Using theatre records, episodes were categorized into days where a surgeon performed overlapping and nonoverlapping lists. Clinical outcomes, economic outcomes, and demographic factors were calculated. A regression model controlling for the patient-specific factors was used to compare groups. Total orthopaedic cases and aggregate time spent operating (time between skin incision and closure) were also compared.Aims
Materials and Methods
Previous studies of failure mechanisms leading
to revision total knee replacement (TKR) performed between 1986 and
2000 determined that many failed early, with a disproportionate
amount accounted for by infection and implant-associated factors
including wear, loosening and instability. Since then, efforts have
been made to improve implant performance and instruct surgeons in
best practice. Recently our centre participated in a multi-centre evaluation
of 844 revision TKRs from 2010 to 2011. The purpose was to report
a detailed analysis of failure mechanisms over time and to see if
failure modes have changed over the past 10 to 15 years. Aseptic
loosening was the predominant mechanism of failure (31.2%), followed
by instability (18.7%), infection (16.2%), polyethylene wear (10.0%),
arthrofibrosis (6.9%) and malalignment (6.6%). The mean time to
failure was 5.9 years (ten days to 31 years), 35.3% of all revisions
occurred at less than two years, and 60.2% in the first five years.
With improvements in implant and polyethylene manufacture, polyethylene
wear is no longer a leading cause of failure. Early mechanisms of
failure are primarily technical errors. In addition to improving
implant longevity, industry and surgeons must work together to decrease
these technical errors. All reports on failure of TKR contain patients
with unexplained pain who not infrequently have unmet expectations.
Surgeons must work to achieve realistic patient expectations pre-operatively,
and therefore, improve patient satisfaction post-operatively. Cite this article:
A small proportion of patients have persistent
pain after total knee replacement (TKR). The primary aim of this study
was to record the prevalence of pain after TKR at specific intervals
post-operatively and to ascertain the impact of neuropathic pain.
The secondary aim was to establish any predictive factors that could
be used to identify patients who were likely to have high levels
of pain or neuropathic pain after TKR. A total of 96 patients were included in the study. Their mean
age was 71 years (48 to 89); 54 (56%) were female. The mean follow-up
was 46 months (39 to 51). Pre-operative demographic details were
recorded including a Visual Analogue Score (VAS) for pain, the Hospital
Anxiety and Depression score as well as the painDETECT score for neuropathic
pain. Functional outcome was assessed using the Oxford Knee score. The mean pre-operative VAS was 5.8 (1 to 10); and it improved
significantly at all time periods post-operatively (p <
0.001):
(from 4.5 at day three to five (1 to 10), 3.2 at six weeks (0 to
9), 2.4 at three months (0 to 7), 2.0 at six months (0 to 9), 1.7
at nine months (0 to 9), 1.5 at one year (0 to 8) and 2.0 at mean
46 months (0 to 10)). There was a high correlation (r >
0.7; p <
0.001) between the mean VAS scores for pain and the mean painDETECT
scores at three months, one year and three years post-operatively.
There was no correlation between the pre-operative scores and any
post-operative scores at any time point. We report the prevalence of pain and neuropathic pain at various
intervals up to three years after TKR. Neuropathic pain is an underestimated
problem in patients with pain after TKR. It peaks at between six
weeks and three-months post-operatively. However, from these data
we were unable to predict which patients are most likely to be affected. Cite this article:
To compare the gait of unicompartmental knee arthroplasty (UKA)
and total knee arthroplasty (TKA) patients with healthy controls,
using a machine-learning approach. 145 participants (121 healthy controls, 12 patients with cruciate-retaining
TKA, and 12 with mobile-bearing medial UKA) were recruited. The
TKA and UKA patients were a minimum of 12 months post-operative,
and matched for pattern and severity of arthrosis, age, and body
mass index. Participants walked on an instrumented treadmill until their
maximum walking speed was reached. Temporospatial gait parameters,
and vertical ground reaction force data, were captured at each speed.
Oxford knee scores (OKS) were also collected. An ensemble of trees
algorithm was used to analyse the data: 27 gait variables were used
to train classification trees for each speed, with a binary output
prediction of whether these variables were derived from a UKA or
TKA patient. Healthy control gait data was then tested by the decision
trees at each speed and a final classification (UKA or TKA) reached
for each subject in a majority voting manner over all gait cycles
and speeds. Top walking speed was also recorded.Aims
Patients and Methods
Fractures around total knee arthroplasties pose
a significant surgical challenge. Most can be managed with osteosynthesis
and salvage of the replacement. The techniques of fixation of these
fractures and revision surgery have evolved and so has the assessment
of outcome. This specialty update summarises the current evidence
for the classification, methods of fixation, revision surgery and
outcomes of the management of periprosthetic fractures associated
with total knee arthroplasty. Cite this article:
We report the results of revision total knee
replacement (TKR) in 26 patients with major metaphyseal osteolytic defects
using 29 trabecular metal cones in conjunction with a rotating hinged
total knee prosthesis. The osteolytic defects were types II and
III (A or B) according to the Anderson Orthopaedic Research Institute
(AORI) classification. The mean age of the patients was 72 years
(62 to 84) and there were 15 men and 11 women. In this series patients had
undergone a mean of 2.34 previous total knee arthroplasties. The
main objective was to restore anatomy along with stability and function
of the knee joint to allow immediate full weight-bearing and active
knee movement. Outcomes were measured using Knee Society scores,
Oxford knee scores, range of movement of the knee and serial radiographs.
Patients were followed for a mean of 36 months (24 to 49). The mean
Oxford knee clinical scores improved from 12.83 (10 to 15) to 35.20
(32 to 38) (p <
0.001) and mean American Knee Society scores
improved from 33.24 (13 to 36) to 81.12 (78 to 86) (p <
0.001).
No radiolucent lines suggestive of loosening were seen around the trabecular
metal cones, and by one year all the radiographs showed good osteo-integration.
There was no evidence of any collapse or implant migration. Our
early results confirm the findings of others that trabecular metal
cones offer a useful way of managing severe bone loss in revision
TKR. Cite this article:
This study reports on the first 150 consecutive
Oxford cementless unicompartmental knee arthroplasties (UKA) performed
in an independent centre (126 patients). All eligible patients had
functional scores (Oxford knee score and high activity arthroplasty
score) recorded pre-operatively and at two- and five-years of follow-up. Fluoroscopically
aligned radiographs were taken at five years and analysed for any
evidence of radiolucent lines (RLLs), subsidence or loosening. The
mean age of the cohort was 63.6 years (39 to 86) with 81 (53.1%)
males. Excellent functional scores were maintained at five years
and there were no progressive RLLs demonstrated on radiographs.
Two patients underwent revision to a total knee arthroplasty giving
a revision rate of 0.23/100 (95% confidence interval 0.03 to 0.84)
component years with overall component survivorship of 98.7% at
five years. There were a further four patients who underwent further
surgery on the same knee, two underwent bearing exchanges for dislocation
and two underwent lateral UKAs for disease progression. This was
a marked improvement from other UKAs reported in New Zealand Joint
Registry data and supports the designing centre’s early results. Cite this article:
Current analysis of unicondylar knee replacements
(UKRs) by national registries is based on the pooled results of medial
and lateral implants. Consequently, little is known about the differential
performance of medial and lateral replacements and the influence
of each implant type within these pooled analyses. Using data from
the National Joint Registry for England and Wales (NJR) we aimed
to determine the proportion of UKRs implanted on the lateral side
of the knee, and their survival and reason for failure compared
with medial UKRs. By combining information on the side of operation
with component details held on the NJR, we were able to determine
implant laterality (medial
Peri-prosthetic infection is amongst the most
common causes of failure following total knee replacement (TKR).
In the presence of established infection, thorough joint debridement
and removal of all components is necessary following which new components
may be implanted. This can be performed in one or two stages; two-stage revision
with placement of an interim antibiotic-loaded spacer is regarded
by many to be the standard procedure for eradication of peri-prosthetic
joint infection. We present our experience of a consecutive series of 50 single-stage
revision TKRs for established deep infection performed between 1979
and 2010. There were 33 women and 17 men with a mean age at revision
of 66.8 years (42 to 84) and a mean follow-up of 10.5 years (2 to
24). The mean time between the primary TKR and the revision procedure
was 2.05 years (1 to 8). Only one patient required a further revision for recurrent infection,
representing a success rate of 98%. Nine patients required further
revision for aseptic loosening, according to microbiological testing
of biopsies taken at the subsequent surgery. Three other patients
developed a further septic episode but none required another revision. These results suggest that a single-stage revision can produce
comparable results to a two-stage revision. Single-stage revision
offers a reduction in costs as well as less morbidity and inconvenience
for patients. Cite this article:
Following arthroplasty of the knee, the patient’s
perception of improvement in symptoms is fundamental to the assessment
of outcome. Better clinical outcome may offset the inferior survival
observed for some types of implant. By examining linked National
Joint Registry (NJR) and patient-reported outcome measures (PROMs)
data, we aimed to compare PROMs collected at a minimum of six months
post-operatively for total (TKR: n = 23 393) and unicondylar knee
replacements (UKR: n = 505). Improvements in knee-specific (Oxford
knee score, OKS) and generic (EuroQol, EQ-5D) scores were compared
and adjusted for case-mix differences using multiple regression.
Whereas the improvements in the OKS and EQ-5D were significantly
greater for TKR than for UKR, once adjustments were made for case-mix
differences and pre-operative score, the improvements in the two
scores were not significantly different. The adjusted mean differences
in the improvement of OKS and EQ-5D were 0.0 (95% confidence interval (CI)
-0.9 to 0.9; p = 0.96) and 0.009 (95% CI -0.034 to 0.015; p = 0.37),
respectively. We found no difference in the improvement of either knee-specific
or general health outcomes between TKR and UKR in a large cohort
of registry patients. With concerns about significantly higher revision
rates for UKR observed in worldwide registries, we question the
widespread use of an arthroplasty that does not confer a significant
benefit in clinical outcome.
The aim of this study was to compare the maximum
laxity conferred by the cruciate-retaining (CR) and posterior-stabilised
(PS) Triathlon single-radius total knee arthroplasty (TKA) for anterior
drawer, varus–valgus opening and rotation in eight cadaver knees
through a defined arc of flexion (0º to 110º). The null hypothesis
was that the limits of laxity of CR- and PS-TKAs are not significantly
different. The investigation was undertaken in eight loaded cadaver knees
undergoing subjective stress testing using a measurement rig. Firstly
the native knee was tested prior to preparation for CR-TKA and subsequently
for PS-TKA implantation. Surgical navigation was used to track maximal
displacements/rotations at 0º, 30º, 60º, 90º and 110° of flexion.
Mixed-effects modelling was used to define the behaviour of the
TKAs. The laxity measured for the CR- and PS-TKAs revealed no statistically
significant differences over the studied flexion arc for the two
versions of TKA. Compared with the native knee both TKAs exhibited
slightly increased anterior drawer and decreased varus-valgus and
internal-external roational laxities. We believe further study is required
to define the clinical states for which the additional constraint
offered by a PS-TKA implant may be beneficial. Cite this article:
The role of high tibial osteotomy (HTO) is being questioned by
the use of unicompartmental knee arthroplasty (UKA) in the treatment
of medial compartment femorotibial osteoarthritis. Our aim was to
compare the outcomes of revision HTO or UKA to a total knee arthroplasty
(TKA) using computer-assisted surgery in matched groups of patients. We conducted a retrospective study to compare the clinical and
radiological outcome of patients who underwent revision of a HTO
to a TKA (group 1) with those who underwent revision of a medial
UKA to a TKA (group 2). All revision procedures were performed using
computer-assisted surgery. We extracted these groups of patients
from our database. They were matched by age, gender, body mass index,
follow-up and pre-operative functional score. The outcomes included
the Knee Society Scores (KSS), radiological outcomes and the rate
of further revision.Aims
Patients and Methods
The purpose of this study was to compare clinical
outcomes of total knee arthroplasty (TKA) after manipulation under
anaesthesia (MUA) for post-operative stiffness with a matched cohort
of TKA patients who did not requre MUA. In total 72 patients (mean age 59.8 years, 42 to 83) who underwent
MUA following TKA were identified from our prospective database
and compared with a matched cohort of patients who had undergone
TKA without subsequent MUA. Patients were evaluated for range of
movement (ROM) and clinical outcome scores (Western Ontario and
McMaster Universities Arthritis Index, Short-Form Health Survey,
and Knee Society Clinical Rating System) at a mean follow-up of
36.4 months (12 to 120). MUA took place at a mean of nine weeks
(5 to 18) after TKA. In patients who required MUA, mean flexion
deformity improved from 10° (0° to 25°) to 4.4° (0° to 15°) (p <
0.001),
and mean range of flexion improved from 79.8° (65° to 95°) to 116°
(80° to 130°) (p <
0.001). There were no statistically significant
differences in ROM or functional outcome scores at three months,
one year, or two years between those who required MUA and those
who did not. There were no complications associated with manipulation At most recent follow-up, patients requiring MUA achieved equivalent
ROM and clinical outcome scores when compared with a matched control
group. While other studies have focused on ROM after manipulation,
the current study adds to current literature by supplementing this
with functional outcome scores. Cite this article:
We sought to establish whether an oxidised zirconium (OxZr) femoral
component causes less loss of polyethylene volume than a cobalt
alloy (CoCr) femoral component in total knee arthroplasty. A total of 20 retrieved tibial inserts that had articulated with
OxZr components were matched with 20 inserts from CoCr articulations
for patient age, body mass index, length of implantation, and revision
diagnosis. Changes in dimensions of the articular surfaces were compared
with those of pristine inserts using laser scanning. The differences
in volume between the retrieved and pristine surfaces of the two
groups were calculated and compared.Aims
Materials and Methods
Unicompartmental knee arthroplasty (UKA) has been successfully
performed in the United States healthcare system on outpatients.
Despite differences in healthcare structure and financial environment,
we hypothesised that it would be feasible to replicate this success
and perform UKA with safe day of surgery discharge within the NHS,
in the United Kingdom. This has not been reported in any other United
Kingdom centres. We report our experience of implementing a pathway to allow safe
day of surgery discharge following UKA. Data were prospectively
collected on 72 patients who underwent UKA as a day case between
December 2011 and September 2015. Aims
Patients and Methods
Risk of revision following total knee arthroplasty (TKA) is higher
in patients under 55 years, but little data are reported regarding
non-revision outcomes. This study aims to identify predictors of
dissatisfaction in these patients. We prospectively assessed 177 TKAs (157 consecutive patients,
99 women, mean age 50 years; 17 to 54) from 2008 to 2013. Age, gender,
implant, indication, body mass index (BMI), social deprivation,
range of movement, Kellgren-Lawrence (KL) grade of osteoarthritis
(OA) and prior knee surgery were recorded. Pre- and post-operative
Oxford Knee Score (OKS) as well as Short Form-12 physical (PCS)
and mental component scores were obtained. Post-operative range
of movement, complications and satisfaction were measured at one
year.Aims
Patients and Methods
We prospectively followed 171 patients who underwent
bilateral unicompartmental knee replacement (UKR) over a period
of two years. Of these, 124 (72.5%) underwent a simultaneous bilateral
procedure and 47 (27.5%) underwent a staged procedure. The mean
cumulative operating time and length of hospital stay were both
shorter in the simultaneous group, by 22.5 minutes (p <
0.001)
and three days (p <
0.001), respectively. The mean reduction
in haemoglobin level post-operatively was greater by 0.15 g/dl in
the simultaneous group (p = 0.023), but this did not translate into
a significant increase in the number of patients requiring blood
transfusion (p = 1.000). The mean hospital cost was lower by $8892
in the simultaneous group (p <
0.001). There was no significant
difference in the rate of complications between the groups, and
at two-year follow-up there was no difference in the outcomes between
the two groups. We conclude that simultaneous bilateral UKR can be recommended
as an appropriate treatment for patients with bilateral medial compartment
osteoarthritis of the knee. Cite this article:
At least four ways have been described to determine
femoral component rotation, and three ways to determine tibial component
rotation in total knee replacement (TKR). Each method has its advocates
and each has an influence on knee kinematics and the ultimate short
and long term success of TKR. Of the four femoral component methods,
the author prefers rotating the femoral component in flexion to
that amount that establishes a stable symmetrical flexion gap. This
judgement is made after the soft tissues of the knee have been balanced
in extension. Of the three tibial component methods, the author prefers rotating
the tibial component into congruency with the established femoral
component rotation with the knee is in extension. This yields a
rotationally congruent articulation during weight-bearing and should
minimise the torsional forces being transferred through a conforming tibial
insert, which could lead to wear to the underside of the tibial
polyethylene. Rotating platform components will compensate for any
mal-rotation, but can still lead to pain if excessive tibial insert
rotation causes soft-tissue impingement. Cite this article:
All major studies have incorporated the use of prolonged courses of parenteral or oral antibiotic therapy in the management of two-stage revision of an infected total knee arthroplasty. We present a series of 59 consecutive patients, all with microbiologically-proven deep infection of a total knee arthroplasty, in whom a prolonged course of antibiotic therapy was not routinely used. The mean follow-up was 56.4 months (24 to 114). Of the 38 patients who underwent a staged exchange, infection was successfully eradicated in 34 (89%) but recurrent or persistent infection was present in four (11%). Our rate of cure for infection is similar to that reported elsewhere. We conclude that a prolonged course of antibiotic therapy seems not to alter the incidence of recurrent or persistent infection. The costs of the administration of antibiotics are high and such a regime may be unnecessary.
Pain is the main indication for performing total knee replacement (TKR). In most patients after TKR there is an improvement, but a few continue to have pain. Generally, the cause of the pain can be addressed when it is identified. However, unexplained pain can be more difficult to manage because revision surgery is likely to be unrewarding in this group. In our study of 622 cemented TKRs in 512 patients with a mean age of 69 years (23 to 90) treated between January 1995 and August 1998, we identified 24 patients (knees) with unexplained pain at six months. This group was followed for five years (data was unavailable for 18 knees) and ten patients (55.5%) went on to show an improvement without intervention. In the case of unexplained pain, management decisions must be carefully considered, but reassurance can be offered to patients that the pain will improve in more than half with time.
Stems improve the mechanical stability of tibial
components in total knee replacement (TKR), but come at a cost of stress
shielding along their length. Their advantages include resistance
to shear, reduced tibial lift-off and increased stability by reducing
micromotion. Longer stems may have disadvantages including stress
shielding along the length of the stem with associated reduction
in bone density and a theoretical risk of subsidence and loosening, peri-prosthetic
fracture and end-of-stem pain. These features make long stems unattractive
in the primary TKR setting, but often desirable in revision surgery
with bone loss and instability. In the revision scenario, stems
are beneficial in order to convey structural stability to the construct
and protect the reconstruction of bony defects. Cemented and uncemented
long stemmed implants have different roles depending on the nature
of the bone loss involved. This review discusses the biomechanics of the design of tibial
components and stems to inform the selection of the component and
the technique of implantation.
We evaluated the rates of survival and cause
of revision of seven different brands of cemented primary total
knee replacement (TKR) in the Norwegian Arthroplasty Register during
the years 1994 to 2009. Revision for any cause, including resurfacing
of the patella, was the primary endpoint. Specific causes of revision
were secondary outcomes. Three posterior cruciate-retaining (PCR) fixed modular-bearing
TKRs, two fixed non-modular bearing PCR TKRs and two mobile-bearing
posterior cruciate-sacrificing TKRs were investigated in a total
of 17 782 primary TKRs. The median follow-up for the implants ranged
from 1.8 to 6.9 years. Kaplan-Meier 10-year survival ranged from
89.5% to 95.3%. Cox’s relative risk (RR) was calculated relative
to the fixed modular-bearing Profix knee (the most frequently used
TKR in Norway), and ranged from 1.1 to 2.6. The risk of revision
for aseptic tibial loosening was higher in the mobile-bearing LCS
Classic (RR 6.8 (95% confidence interval (CI) 3.8 to 12.1)), the
LCS Complete (RR 7.7 (95% CI 4.1 to 14.4)), the fixed modular-bearing
Duracon (RR 4.5 (95% CI 1.8 to 11.1)) and the fixed non-modular
bearing AGC Universal TKR (RR 2.5 (95% CI 1.3 to 5.1)), compared
with the Profix. These implants (except AGC Universal) also had
an increased risk of revision for femoral loosening (RR 2.3
(95% CI 1.1 to 4.8), RR 3.7 (95% CI 1.6 to 8.9), and RR 3.4 (95%
CI 1.1 to 11.0), respectively). These results suggest that aseptic
loosening is related to design in TKR. Cite this article:
We report ten-year clinical and radiological
follow-up data for the Sigma Press Fit Condylar total knee replacement system
(Sigma PFC TKR). Between October 1998 and October 1999 a total of
235 consecutive PFC Sigma TKRs were carried out in 203 patients.
Patients were seen at a specialist nurse-led clinic seven to ten
days before admission and at six and 18 months, three, five and
eight to ten years after surgery. Data were recorded prospectively
at each clinic visit. Radiographs were obtained at the five- and
eight- to ten-year follow-up appointments. Of the 203 patients,
147 (171 knees) were alive at ten years and 12 were lost to follow-up.
A total of eight knees (3.4%) were revised, five for infection and
three to change the polyethylene insert. The survival at ten years
with an endpoint of revision for any reason was 95.9%, and with
an endpoint of revision for aseptic failure was 98.7%. The mean
American Knee Society Score (AKSS) was 79 (10 to 99) at eight to
ten years, compared with 31 (2 to 62) pre-operatively. Of 109 knee
with radiographs reviewed, 47 knees had radiolucent lines but none
showed evidence of loosening. Cite this article:
Smart trials are total knee tibial trial liners
with load bearing and alignment sensors that will graphically show quantitative
compartment load-bearing forces and component track patterns. These
values will demonstrate asymmetrical ligament balancing and misalignments
with the medial retinaculum temporarily closed. Currently surgeons
use feel and visual estimation of imbalance to assess soft-tissue
balancing and tracking with the medial retinaculum open, which results
in lower medial compartment loads and a wider anteroposterior tibial
tracking pattern. The sensor trial will aid the total knee replacement
surgeon in performing soft-tissue balancing by providing quantitative
visual feedback of changes in forces while performing the releases
incrementally. Initial experience using a smart tibial trial is
presented.
Peri-prosthetic patellar fracture following resurfacing
as part of total knee replacement (TKR) is an infrequent yet challenging
complication. This case-control study was performed to identify
clinical, radiological and surgical factors that increase the risk
of developing a spontaneous patellar fracture after TKR. Patellar
fractures were identified in 74 patients (88 knees) from a series
of 7866 consecutive TKRs conducted between 1998 and 2009. After excluding
those with a previous history of extensor mechanism realignment
or a clear traumatic event, a metal-backed patella, any uncemented
component or subsequent infection, the remaining 64 fractures were
compared with a matched group of TKRs with an excellent outcome
defined by the Knee Society score. The mean age of patients with
a fracture was 70 years (51 to 81) at the time of TKR. Patellar
fractures were detected at a mean of 13.4 months (2 to 84) after
surgery. The incidence of patellar fracture was found to be strongly
associated with the number of previous knee operations, greater
pre-operative mechanical malalignment, smaller post-operative patellar
tendon length, thinner post-resection patellar thickness, and a
lower post-operative Insall-Salvati ratio. An understanding of the risk factors associated with spontaneous
patellar fracture following TKR provides a valuable insight into
prevention of this challenging complication.
We carried out 60 revision procedures for failed porous coated anatomic total knee replacements in 54 patients, which were divided into two groups. The 14 knees in group I had a well-fixed femoral component at surgery which was retained, and in the 46 knees in group II both tibial and femoral components were loose and were revised using a variety of implants. Our review comprised clinical and radiological assessment. A total of 13 knees required a second revision. Six (42%) in group I failed very early (mean 2.1 years) when compared with seven (15%) in group II (mean 6.8 years). Failure was due to wear of the polyethylene insert by the abraded, retained femoral component (crude odds ratio 4.07; 95% CI 1.07 to 15.5). We recommend a complete change of primary bearing surfaces at the time of revision of an uncemented total knee replacement in order to prevent early wear of polyethylene.
The optimal timing of total knee replacement
(TKR) in patients with osteoarthritis, in relation to the severity
of disease, remains controversial. This prospective study was performed
to investigate the effect of the severity of osteoarthritis and
other commonly available pre- and post-operative clinical parameters
on the clinical outcome in a consecutive series of cemented TKRs.
A total of 176 patients who underwent unilateral TKR were included
in the study. Their mean age was 68 years (39 to 91), 63 (36%) were
male and 131 knees (74%) were classified as grade 4 on the Kellgren–Lawrence
osteoarthritis scale. A total of 154 patients (87.5%) returned for
clinical review 12 months post-operatively, at which time the outcome
was assessed using the Knee Society score. A low radiological severity of osteoarthritis was not associated
with pain 12 months post-operatively. However, it was significantly
associated with an inferior level of function (p = 0.007), implying
the need for increased focus on all possible reasons for pain in
the knee and the forms of conservative treatment which are available
for patients with lower radiological severity of osteoarthritis. Cite this article:
We reviewed 231 patients who had undergone total knee replacement with an AGC (Biomet) implant over a period of 2.5 years. After applying exclusion criteria and with some loss to follow-up, there were 144 patients available for study. These were divided into two groups; those who had received intra-articular steroid in the 11 months before surgery and those who had not. There were three deep infections, all of which occurred in patients who had received a steroid injection. The incidence of superficial infection was not significantly different in the two groups. Five patients had undergone investigation for suspected deep infection because of persistent swelling or pain and all of these had received an intra-articular injection pre-operatively. We conclude that the decision to administer intra-articular steroids to a patient who may be a candidate for total knee replacement should not be taken lightly because of a risk of post-operative deep infection.
The PROSTALAC functional spacer is made of antibiotic-loaded acrylic cement but has a small metal-on-polythene articular surface. We have used it as an interim spacer in two-stage exchange arthroplasty for infected total knee replacement. PROSTALAC allows continuous rehabilitation between stages as it maintains good alignment and stability of the knee and a reasonable range of movement. It also helps to maintain the soft-tissue planes, which facilitates the second-stage procedure. We reviewed 45 consecutive patients, treated over a period of nine years. The mean follow-up was for 48 months (20 to 112). At final review, there was no evidence of infection in 41 patients (91%); only one had a recurrent infection with the same organism. There was improvement in the Hospital for Special Surgery knee score between stages and at final review. The range of movement was maintained between stages. Complications were primarily related to the extensor mechanism and stability of the knee between stages. Both of these problems decreased with refinement of the design of the implant. The rate of cure of the infection in our patients was similar to that using other methods. Movement of the knee does not appear to hinder control of infection.
This prospective study compares the outcome of
157 hydroxyapatite (HA)-coated tibial components with 164 cemented
components in the ROCC Rotating Platform total knee replacement
in 291 patients. The mean follow-up was 7.6 years (5.2 to 11). There
were two revisions for loosening: one for an HA-coated and one for
a cemented tibial component. Radiological evaluation demonstrated
no radiolucent lines with the HA-coated femoral components. A total
of three HA-coated tibial components exhibited radiolucent lines
at three months post-operatively and these disappeared after three
further months of protected weight-bearing. With HA-coated components
the operating time was shorter (p <
0.006) and the radiological
assessment of the tibial interface was more stable (p <
0.01).
Using revision for aseptic loosening of the tibial component as
the end point, the survival rates at nine years was identical for
both groups at 99.1%. Our results suggest that HA-coated components perform at least
as well as the same design with cemented components and compare
favourably with those of series describing cemented or porous-coated
knee replacements, suggesting that fixation of both components with
hydroxyapatite is a reliable option in primary total knee replacement.
The purpose of this study was to measure the
radiological parameters of femoral component alignment of the Oxford
Phase 3 unicompartmental knee replacement (UKR), and evaluate their
effect on clinical outcome. Multiple regression analysis was used
to examine the relative contributions of the radiological assessment
of femoral component alignment in 189 consecutive UKRs performed
by a single surgeon. The American Knee Society scores were compared
between groups, defined as being within or outside recommended tolerances
of the position of the femoral component. For the flexion/extension
position 21 UKRs (11.1%) lay outside the recommended limits, and for
posterior overhang of the femoral component nine (4.8%) lay outside
the range. The pre-operative hip/knee/ankle (HKA) angle, narrowest
canal distance from the distal femoral entry point of the alignment
jig and coronal entry-point position had significant effects on
the flexion/extension position. Pre-operative HKA angle had a significant
influence on posterior overhang of the femoral component. However,
there was no significant difference in American Knee Society scores
relative to the position of the femoral component.
We have compared the survival of 67 revision arthroplasties of the knee undertaken for aseptic loosening with and without the retention of a secure, cemented femoral component. All the patients had undergone a single primary procedure at a mean of nine years previously. In group I (25 knees) the original femoral component was secure and was retained. There were no abrasions or osteolysis. The knees were stable, normally aligned, with minimal bone loss. In group II 42 knees did not fulfil these criteria and underwent revision of both components. The mean follow-up was four years. Re-revision for loosening was required in seven knees (28%) in group I and three (7%) in group II (p <
0.01). The remaining knees function well with Knee Society scores averaging 84/69 and no radiological evidence of osteolysis. When revising cemented implants, retention of a secure femoral component cannot be recommended even when conditions appear to be suitable.
Aims. Medial unicompartmental knee arthroplasty (mUKA) is an advised treatment for anteromedial knee osteoarthritis. While long-term survival after mUKA is well described, reported incidences of short-term surgical complications vary and the effect of surgical usage on complications is less established. We aimed to describe the overall occurrence and treatment of surgical complications within 90 days of mUKA, as well as occurrence in high-usage centres compared to low-usage centres. Methods. mUKAs performed in eight fast-track centres from February 2010 to June 2018 were included from the Lundbeck Foundation Centre for Fast-track Hip and
Aims. Metal particles detached from metal-on-metal hip prostheses (MoM-THA) have been shown to cause inflammation and destruction of tissues. To further explore this, we investigated the histopathology (aseptic lymphocyte-dominated vasculitis-associated lesions (ALVAL) score) and metal concentrations of the periprosthetic tissues obtained from patients who underwent revision
Aims. Aseptic loosening is the most common cause of failure following cemented total knee arthroplasty (TKA), and has been linked to poor cementation technique. We aimed to develop a consensus on the optimal technique for component cementation in TKA. Methods. A UK-based, three-round, online modified Delphi Expert Consensus Study was completed focusing on cementation technique in TKA. Experts were identified as having a minimum of five years’ consultant experience in the NHS and fulfilling any one of the following criteria: a ‘high volume’