Aims. While internet search engines have been the primary information source for patients’ questions, artificial intelligence large language models like ChatGPT are trending towards becoming the new primary source. The purpose of this study was to determine if ChatGPT can answer patient questions about total hip (THA) and knee arthroplasty (TKA) with consistent
Aims. National joint registries under-report revisions for periprosthetic joint infection (PJI). We aimed to validate PJI reporting to the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR) and the factors associated with its
Aims. The aim of this study was to determine the diagnostic
Aims. The aim of this study was to evaluate the diagnostic
Aims. The aims of this study were to increase the diagnostic accuracy
of the analysis of synovial fluid in the differentiation of prosthetic
joint infection (PJI) by the addition of inexpensive biomarkers
such as the levels of C-reactive protein (CRP), adenosine deaminase
(ADA), alpha-2-macrogloblulin (α2M) and procalcitonin. Patients and Methods. Between January 2013 and December 2015, synovial fluid and removed
implants were requested from 143 revision total joint arthroplasties.
A total of 55 patients met inclusion criteria of the receipt of
sufficient synovial fluid, tissue samples and removed implants for
analysis. The diagnosis of PJI followed the definition from a recent International
Consensus Meeting to create two groups of patients; septic and aseptic.
Using receiver operating characteristic curves we determined the
cutoff values and diagnostic
Aims. To examine whether natural language processing (NLP) using a clinically based large language model (LLM) could be used to predict patient selection for total hip or total knee arthroplasty (THA/TKA) from routinely available free-text radiology reports. Methods. Data pre-processing and analyses were conducted according to the Artificial intelligence to Revolutionize the patient Care pathway in Hip and knEe aRthroplastY (ARCHERY) project protocol. This included use of de-identified Scottish regional clinical data of patients referred for consideration of THA/TKA, held in a secure data environment designed for artificial intelligence (AI) inference. Only preoperative radiology reports were included. NLP algorithms were based on the freely available GatorTron model, a LLM trained on over 82 billion words of de-identified clinical text. Two inference tasks were performed: assessment after model-fine tuning (50 Epochs and three cycles of k-fold cross validation), and external validation. Results. For THA, there were 5,558 patient radiology reports included, of which 4,137 were used for model training and testing, and 1,421 for external validation. Following training, model performance demonstrated average (mean across three folds)
Aims. Total hip arthroplasty (THA) and total knee arthroplasty (TKA) are common orthopaedic procedures requiring postoperative radiographs to confirm implant positioning and identify complications. Artificial intelligence (AI)-based image analysis has the potential to automate this postoperative surveillance. The aim of this study was to prepare a scoping review to investigate how AI is being used in the analysis of radiographs following THA and TKA, and how accurate these tools are. Methods. The Embase, MEDLINE, and PubMed libraries were systematically searched to identify relevant articles. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for scoping reviews and Arksey and O’Malley framework were followed. Study quality was assessed using a modified Methodological Index for Non-Randomized Studies tool. AI performance was reported using either the area under the curve (AUC) or
Aims. The aim of this study was to evaluate the diagnostic
Aims. Histology is widely used for diagnosis of persistent infection during reimplantation in two-stage revision hip and knee arthroplasty, although data on its utility remain scarce. Therefore, this study aims to assess the predictive value of permanent sections at reimplantation in relation to reinfection risk, and to compare results of permanent and frozen sections. Methods. We retrospectively collected data from 226 patients (90 hips, 136 knees) with periprosthetic joint infection who underwent two-stage revision between August 2011 and September 2021, with a minimum follow-up of one year. Histology was assessed via the SLIM classification. First, we analyzed whether patients with positive permanent sections at reimplantation had higher reinfection rates than patients with negative histology. Further, we compared permanent and frozen section results, and assessed the influence of anatomical regions (knee versus hip), low- versus high-grade infections, as well as first revision versus multiple prior revisions on the histological result at reimplantation. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), chi-squared tests, and Kaplan-Meier estimates were calculated. Results. Overall, the reinfection rate was 18%. A total of 14 out of 82 patients (17%) with positive permanent sections at reimplantation experienced reinfection, compared to 26 of 144 patients (18%) with negative results (p = 0.996). Neither permanent sections nor fresh frozen sections were significantly associated with reinfection, with a sensitivity of 0.35, specificity of 0.63, PPV of 0.17, NPV of 0.81, and
Aims. Synovial fluid white blood cell (WBC) count and percentage of polymorphonuclear cells (%PMN) are elevated at periprosthetic joint infection (PJI). Leucocytes produce different interleukins (IL), including IL-6, so we hypothesized that synovial fluid IL-6 could be a more accurate predictor of PJI than synovial fluid WBC count and %PMN. The main aim of our study was to compare the predictive performance of all three diagnostic tests in the detection of PJI. Methods. Patients undergoing total hip or knee revision surgery were included. In the perioperative assessment phase, synovial fluid WBC count, %PMN, and IL-6 concentration were measured. Patients were labeled as positive or negative according to the predefined cut-off values for IL-6 and WBC count with %PMN. Intraoperative samples for microbiological and histopathological analysis were obtained. PJI was defined as the presence of sinus tract, inflammation in histopathological samples, and growth of the same microorganism in a minimum of two or more samples out of at least four taken. Results. In total, 49 joints in 48 patients (mean age 68 years (SD 10; 26 females (54%), 25 knees (51%)) were included. Of these 11 joints (22%) were infected. The synovial fluid WBC count and %PMN predicted PJI with sensitivity, specificity,
Aims. The aim of this study was to further evaluate the
Aims. The diagnosis of periprosthetic joint infection (PJI) can be difficult. All current diagnostic tests have problems with
Aims. Metagenomic next-generation sequencing (mNGS) is useful in the diagnosis of infectious disease. However, while it is highly sensitive at identifying bacteria, it does not provide information on the sensitivity of the organisms to antibiotics. The purpose of this study was to determine whether the results of mNGS can be used to guide optimization of culture methods to improve the sensitivity of culture from intraoperative samples. Methods. Between July 2014 and October 2019, patients with suspected joint infection (JI) from whom synovial fluid (SF) was obtained preoperatively were enrolled. Preoperative aspirated SF was analyzed by conventional microbial culture and mNGS. In addition to samples taken for conventional microbial culture, some samples were taken for intraoperative culture to optimize the culture method according to the preoperative mNGS results. The demographic characteristics, medical history, laboratory examination, mNGS, and culture results of the patients were recorded, and the possibility of the optimized culture methods improving diagnostic efficiency was evaluated. Results. A total of 56 cases were included in this study. There were 35 cases of JI and 21 cases of non-joint infection (NJI). The sensitivity, specificity, and
Aims. Use of molecular sequencing methods in periprosthetic joint infection (PJI) diagnosis and organism identification have gained popularity. Next-generation sequencing (NGS) is a potentially powerful tool that is now commercially available. The purpose of this study was to compare the diagnostic
Aims. Biopsy of the periprosthetic tissue is an important diagnostic tool for prosthetic joint infection (PJI) as it enables the detection of the responsible microorganism with its sensitivity to antibiotics. We aimed to investigate how often the bacteria identified in the tissue analysis differed between samples obtained from preoperative biopsy and intraoperative revision surgery in cases of late PJI; and whether there was a therapeutic consequence. Methods. A total of 508 patients who required revision surgery of total hip arthroplasty (THA) (n = 231) or total knee arthroplasty (TKA) (n = 277) because of component loosening underwent biopsy before revision surgery. The tissue samples collected at biopsy and during revision surgery were analyzed according to the criteria of the Musculoskeletal Infection Society (MSIS). Results. In total, 178 (113 THA, 65 TKA) were classified as infected. The biopsy procedure had a sensitivity of 93.8%, a specificity of 97.3%, a positive predictive value (PPV) of 94.9%, a negative predictive value (NPV) of 96.7%, and an
The aim of this study was to evaluate the optimal deep tissue specimen sample number for histopathological analysis in the diagnosis of periprosthetic joint infection (PJI). In this retrospective diagnostic study, patients undergoing revision surgery after total hip or knee arthroplasty (n = 119) between January 2015 and July 2018 were included. Multiple specimens of the periprosthetic membrane and pseudocapsule were obtained for histopathological analysis at revision arthroplasty. Based on the Infectious Diseases Society of America (IDSA) 2013 criteria, the International Consensus Meeting (ICM) 2018 criteria, and the European Bone and Joint Infection Society (EBJIS) 2021 criteria, PJI was defined. Using a mixed effects logistic regression model, the sensitivity and specificity of the histological diagnosis were calculated. The optimal number of periprosthetic tissue specimens for histopathological analysis was determined by applying the Youden index.Aims
Methods
The outcomes of patients with unexpected positive cultures (UPCs) during revision total hip arthroplasty (THA) and total knee arthroplasty (TKA) remain unknown. The objectives of this study were to establish the prevalence and infection-free implant survival in UPCs during presumed aseptic single-stage revision THA and TKA at mid-term follow-up. This study included 297 patients undergoing presumed aseptic single-stage revision THA or TKA at a single treatment centre. All patients with at least three UPCs obtained during revision surgery were treated with minimum three months of oral antibiotics following revision surgery. The prevalence of UPCs and causative microorganisms, the recurrence of periprosthetic joint infections (PJIs), and the infection-free implant survival were established at minimum five years’ follow-up (5.1 to 12.3).Aims
Methods
A substantial fraction of patients undergoing knee arthroplasty (KA) or hip arthroplasty (HA) do not achieve an improvement as high as the minimal clinically important difference (MCID), i.e. do not achieve a meaningful improvement. Using three patient-reported outcome measures (PROMs), our aim was: 1) to assess machine learning (ML), the simple pre-surgery PROM score, and logistic-regression (LR)-derived performance in their prediction of whether patients undergoing HA or KA achieve an improvement as high or higher than a calculated MCID; and 2) to test whether ML is able to outperform LR or pre-surgery PROM scores in predictive performance. MCIDs were derived using the change difference method in a sample of 1,843 HA and 1,546 KA patients. An artificial neural network, a gradient boosting machine, least absolute shrinkage and selection operator (LASSO) regression, ridge regression, elastic net, random forest, LR, and pre-surgery PROM scores were applied to predict MCID for the following PROMs: EuroQol five-dimension, five-level questionnaire (EQ-5D-5L), EQ visual analogue scale (EQ-VAS), Hip disability and Osteoarthritis Outcome Score-Physical Function Short-form (HOOS-PS), and Knee injury and Osteoarthritis Outcome Score-Physical Function Short-form (KOOS-PS).Aims
Methods
Data of high quality are critical for the meaningful interpretation of registry information. The National Joint Registry (NJR) was established in 2002 as the result of an unexpectedly high failure rate of a cemented total hip arthroplasty. The NJR began data collection in 2003. In this study we report on the outcomes following the establishment of a formal data quality (DQ) audit process within the NJR, within which each patient episode entry is validated against the hospital unit’s Patient Administration System and vice-versa. This process enables bidirectional validation of every NJR entry and retrospective correction of any errors in the dataset. In 2014/15 baseline average compliance was 92.6% and this increased year-on-year with repeated audit cycles to 96.0% in 2018/19, with 76.4% of units achieving > 95% compliance. Following the closure of the audit cycle, an overall compliance rate of 97.9% was achieved for the 2018/19 period. An automated system was initiated in 2018 to reduce administrative burden and to integrate the DQ process into standard workflows. Our processes and quality improvement results demonstrate that DQ may be implemented successfully at national level, while minimizing the burden on hospitals. Cite this article:
Objectives. Computed tomography (CT) plays an important role in evaluating wear and periacetabular osteolysis (PAO) in total hip replacements. One concern with CT is the high radiation exposure since standard pelvic CT provides approximately 3.5 millisieverts (mSv) of radiation exposure, whereas a planar radiographic examination with three projections totals approximately 0.5 mSv. The objective of this study was to evaluate the lowest acceptable radiation dose for dual-energy CT (DECT) images when measuring wear and periacetabular osteolysis in uncemented metal components. Materials and Methods. A porcine pelvis with bilateral uncemented hip prostheses and with known linear wear and acetabular bone defects was examined in a third-generation multidetector DECT scanner. The examinations were performed with four different radiation levels both with and without iterative reconstruction techniques. From the high and low peak kilo voltage acquisitions, polychrmoatic images were created together with virtual monochromatic images of energies 100 kiloelectron volts (keV) and 150 keV. Results. We could assess wear and PAO while substantially lowering the effective radiation dose to 0.7 mSv for a total pelvic view with an
The purpose of this study was to compare the
diagnostic
The aim of this study was to estimate the 90-day periprosthetic joint infection (PJI) rates following total knee arthroplasty (TKA) and total hip arthroplasty (THA) for osteoarthritis (OA). This was a data linkage study using the New South Wales (NSW) Admitted Patient Data Collection (APDC) and the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), which collect data from all public and private hospitals in NSW, Australia. Patients who underwent a TKA or THA for OA between 1 January 2002 and 31 December 2017 were included. The main outcome measures were 90-day incidence rates of hospital readmission for: revision arthroplasty for PJI as recorded in the AOANJRR; conservative definition of PJI, defined by T84.5, the PJI diagnosis code in the APDC; and extended definition of PJI, defined by the presence of either T84.5, or combinations of diagnosis and procedure code groups derived from recursive binary partitioning in the APDC.Aims
Methods
Objectives. Wear debris released from bearing surfaces has been shown to
provoke negative immune responses in the recipient. Excessive wear
has been linked to early failure of prostheses. Analysis using coordinate
measuring machines (CMMs) can provide estimates of total volumetric
material loss of explanted prostheses and can help to understand
device failure. The
Tranexamic acid (TXA) is now commonly used in major surgical operations including orthopaedics. The TRAC-24 randomized control trial (RCT) aimed to assess if an additional 24 hours of TXA postoperatively in primary total hip (THA) and total knee arthroplasty (TKA) reduced blood loss. Contrary to other orthopaedic studies to date, this trial included high-risk patients. This paper presents the results of a cost analysis undertaken alongside this RCT. TRAC-24 was a prospective RCT on patients undergoing TKA and THA. Three groups were included: Group 1 received 1 g intravenous (IV) TXA perioperatively and an additional 24-hour postoperative oral regime, Group 2 received only the perioperative dose, and Group 3 did not receive TXA. Cost analysis was performed out to day 90.Aims
Methods
Aims. α-defensin is a biomarker which has been described as having
a high degree of
Fungal and mycobacterial periprosthetic joint infections (PJI) are rare events. Clinicians are wary of missing these diagnoses, often leading to the routine ordering of fungal and mycobacterial cultures on periprosthetic specimens. Our goal was to examine the utility of these cultures and explore a modern bacterial culture technique using bacterial blood culture bottles (BCBs) as an alternative. We performed a retrospective review of patients diagnosed with hip or knee PJI between 1 January 2010 and 31 December 2019, at the Mayo Clinic in Rochester, Minnesota, USA. We included patients aged 18 years or older who had fungal, mycobacterial, or both cultures performed together with bacterial cultures. Cases with positive fungal or mycobacterial cultures were reviewed using the electronic medical record to classify the microbiological findings as representing true infection or not.Aims
Methods
Aims. The purpose of this current multicentre study is to analyse the
presence of alpha-defensin proteins in synovial fluid using the
Synovasure lateral flow device and to determine its diagnostic reliability
and
Debridement, antibiotics, and implant retention (DAIR) is a widely accepted form of surgical treatment for patients with an early periprosthetic joint infection (PJI) after primary arthroplasty. The outcome of DAIR after revision arthroplasty, however, has not been reported. The aim of this study was to report the success rate of DAIR after revision arthroplasty with a follow-up of two years. This retrospective study, conducted at the Sint Maartenskliniek, Nijmegen, the Netherlands, included 88 patients who underwent DAIR within 90 days of revision total hip or total knee arthroplasty between 2012 and 2019. Details of the surgical procedures and PJI were collected. Univariate analysis and a subgroup analysis of the culture-positive group were performed. Kaplan-Meier survivorship curves were constructed.Aims
Methods
The aim of this study was to determine satisfaction rates after hip and knee arthroplasty in patients who did not respond to postoperative patient-reported outcome measures (PROMs), characteristics of non-responders, and contact preferences to maximize response rates. A prospective cohort study of patients planned to undergo hip arthroplasty (n = 713) and knee arthroplasty (n = 737) at a UK university teaching hospital who had completed preoperative PROMs questionnaires, including the EuroQol five-dimension health-related quality of life score, and Oxford Hip Score (OHS) and Oxford Knee Score (OKS). Follow-up questionnaires were sent by post at one year, including satisfaction scoring. Attempts were made to contact patients who did not initially respond. Univariate, logistic regression, and receiver operator curve analysis was performed.Aims
Methods
Aims. The diagnosis of periprosthetic joint infection (PJI) remains
demanding due to limitations of all the available diagnostic tests.
The synovial fluid marker, α-defensin, is a promising adjunct for
the assessment of potential PJI. The purpose of this study was to
investigate the qualitative assessment of α-defensin, using Synovasure
to detect or exclude periprosthetic infection in total joint arthroplasty. Patients and Methods. We studied 50 patients (28 women, 22 men, mean age 65 years;
20 to 89) with a clinical indication for revision arthroplasty who
met the inclusion criteria of this prospective diagnostic study.
The presence of α-defensin was determined using the qualitative
Synovasure test and compared with standard diagnostic methods for
PJI. Based on modified Musculoskeletal Infection Society (MSIS)
criteria, 13 cases were categorised as septic and 36 as aseptic revisions.
One test was inconclusive. Results. The Synovasure test achieved a sensitivity of 69% and a specificity
of 94%. The positive and negative likelihood ratios were 12.46 and
0.33, respectively. A good diagnostic
Antibiotic prophylaxis involving timely administration of appropriately dosed antibiotic is considered effective to reduce the risk of surgical site infection (SSI) after total hip and total knee arthroplasty (THA/TKA). Cephalosporins provide effective prophylaxis, although evidence regarding the optimal timing and dosage of prophylactic antibiotics is inconclusive. The aim of this study is to examine the association between cephalosporin prophylaxis dose, timing, and duration, and the risk of SSI after THA/TKA. A prospective multicentre cohort study was undertaken in consenting adults with osteoarthritis undergoing elective primary TKA/THA at one of 19 high-volume Australian public/private hospitals. Data were collected prior to and for one-year post surgery. Logistic regression was undertaken to explore associations between dose, timing, and duration of cephalosporin prophylaxis and SSI. Data were analyzed for 1,838 participants. There were 264 SSI comprising 63 deep SSI (defined as requiring intravenous antibiotics, readmission, or reoperation) and 161 superficial SSI (defined as requiring oral antibiotics) experienced by 249 (13.6%) participants within 365 days of surgery.Aims
Methods
Aims . Recently, several synovial biomarkers have been introduced into
the algorithm for the diagnosis of a prosthetic joint infection
(PJI). Alpha defensin is a promising biomarker, with a high sensitivity
and specificity, but it is expensive. Calprotectin is a protein
that is present in the cytoplasm of neutrophils, is released upon
neutrophil activation and exhibits anti-microbial activity. Our
aim, in this study, was to determine the diagnostic potential of
synovial calprotectin in the diagnosis of a PJI. Patients and Methods. In this pilot study, we prospectively collected synovial fluid
from the hip, knee, shoulder and elbow of 19 patients with a proven
PJI and from a control group of 42 patients who underwent revision
surgery without a PJI. PJI was diagnosed according to the current diagnostic criteria
of the Musculoskeletal Infection Society. Synovial fluid was centrifuged
and the supernatant was used to measure the level of calprotectin
after applying a lateral flow immunoassay. . Results. The median synovial calprotectin level was 991 mg/L (interquartile
range (IQR) 154 to 1787) in those with a PJI and 11 mg/L (IQR 3
to 29) in the control group (p <
0.0001). Using a cut-off value
of 50 mg/L, this level showed an excellent diagnostic
We have investigated the
To determine the trajectories of patient reported pain and functional disability over five years following total hip arthroplasty (THA) or total knee arthroplasty (TKA). A prospective, longitudinal cohort sub-study within the National Joint Registry (NJR) was undertaken. In all, 20,089 patients who underwent primary THA and 22,489 who underwent primary TKA between 2009 and 2010 were sent Oxford Hip Score (OHS) and Oxford Knee Score (OKS) questionnaires at six months, and one, three, and five years postoperatively. OHS and OKS were disaggregated into pain and function subscales. A k-means clustering procedure assigned each patient to a longitudinal trajectory group for pain and function. Ordinal regression was used to predict trajectory group membership using baseline OHS and OKS score, age, BMI, index of multiple deprivation, sex, ethnicity, geographical location, and American Society of Anesthesiologists grade.Aims
Methods
If patients could recall their physical status
before total hip (THA) or knee arthroplasty (TKA) accurately it
could have valuable applications both clinically and for research.
This study evaluated the
While preoperative bloodwork is routinely ordered, its value in determining which patients are at risk of postoperative readmission following total knee arthroplasty (TKA) and total hip arthroplasty (THA) is unclear. The objective of this study was to determine which routinely ordered preoperative blood markers have the strongest association with acute hospital readmission for patients undergoing elective TKA and THA. Two population-based retrospective cohorts were assembled for all adult primary elective TKA (n = 137,969) and THA (n = 78,532) patients between 2011 to 2018 across 678 North American hospitals using the American College of Surgeons National Quality Improvement Programme (ACS-NSQIP) registry. Six routinely ordered preoperative blood markers - albumin, haematocrit, platelet count, white blood cell count (WBC), estimated glomerular filtration rate (eGFR), and sodium level - were queried. The association between preoperative blood marker values and all-cause readmission within 30 days of surgery was compared using univariable analysis and multivariable logistic regression adjusted for relevant patient and treatment factors.Aims
Methods
Using general practitioner records and hospital
notes and through direct telephone conversation with patients, we investigated
the
As a proven and comprehensive molecular technique, metagenomic next-generation sequencing (mNGS) has shown its potential in the diagnosis of pathogens in patients with periprosthetic joint infection (PJI), using a single type of specimen. However, the optimal use of mNGS in the management of PJI has not been explored. In this study, we evaluated the diagnostic value of mNGS using three types of specimen with the aim of achieving a better choice of specimen for mNGS in these patients. In this prospective study, 177 specimens were collected from 59 revision arthroplasties, including periprosthetic tissues, synovial fluid, and prosthetic sonicate fluid. Each specimen was divided into two, one for mNGS and one for culture. The criteria of the Musculoskeletal Infection Society were used to define PJI (40 cases) and aseptic failure (19 cases).Aims
Methods
The primary aim was to assess the rate of postoperative COVID-19 following hip and knee arthroplasty performed in March 2020 in the UK. The secondary aims were to assess whether there were clinical factors associated with COVID-19 status, the mortality rate of patients with COVID-19, and the rate of potential COVID-19 in patients not presenting to healthcare services. A multicentre retrospective study was conducted of patients undergoing hip or knee arthroplasty during the first wave of the COVID-19 pandemic (1 March 2020 to 31 March 2020) with a minimum of 60 days follow-up. Patient demographics, American Society of Anesthesiologists grade, procedure type, primary or revision, length of stay (LOS), COVID-19 test status, and postoperative mortality were recorded. A subgroup of patients (n = 211) who had not presented to healthcare services after discharge were contacted and questioned as to whether they had symptoms of COVID-19.Aims
Methods
Calprotectin (CLP) is produced in neutrophils and monocytes and released into body fluids as a result of inflammation or infection. The aim of this study was to evaluate the utility of blood and synovial CLP in the diagnosis of chronic periprosthetic joint infection (PJI). Blood and synovial fluid samples were collected prospectively from 195 patients undergoing primary or revision hip and knee arthroplasty. Patients were divided into five groups: 1) primary total hip and knee arthroplasty performed due to idiopathic osteoarthritis (OA; n = 60); 2) revision hip and knee arthroplasty performed due to aseptic failure of the implant (AR-TJR; n = 40); 3) patients with a confirmed diagnosis of chronic PJI awaiting surgery (n = 45); 4) patients who have finished the first stage of the PJI treatment with the use of cemented spacer and were qualified for replantation procedure (SR-TJR; n = 25), and 5) patients with rheumatoid arthritis undergoing primary total hip and knee arthroplasty (RA; n = 25). CLP concentrations were measured quantitatively in the blood and synovial fluid using an immunoturbidimetric assay. Additionally, blood and synovial CRP, blood interleukin-6 (IL-6), and ESR were measured, and a leucocyte esterase (LE) strip test was performed.Aims
Methods
Digital radiography is becoming widespread. Accurate pre-operative templating of digital images of the hip traditionally involves positioning a calibration object at its centre. This can be difficult and cause embarrassment. We have devised a method whereby a planar disc placed on the radiographic cassette accounts for the expected magnification. Initial examination of 50 pelvic CT scans showed a mean hip centre distance of 117 mm (79 to 142) above the gluteal skin. Further calculations predicted that a disc of 37.17 mm diameter, placed on the cassette, would appear identical to a 30 mm sphere placed at the level of the centre of the hip as requested by our templating software. We assessed
To develop and validate patient-centred algorithms that estimate individual risk of death over the first year after elective joint arthroplasty surgery for osteoarthritis. A total of 763,213 hip and knee joint arthroplasty episodes recorded in the National Joint Registry for England and Wales (NJR) and 105,407 episodes from the Norwegian Arthroplasty Register were used to model individual mortality risk over the first year after surgery using flexible parametric survival regression.Aims
Methods
Prosthetic joint infection (PJI) remains a major clinical challenge. Neutrophil CD64 index, Fc-gamma receptor 1 (FcγR1), plays an important role in mediating inflammation of bacterial infections and therefore could be a valuable biomarker for PJI. The aim of this study is to compare the neutrophil CD64 index in synovial and blood diagnostic ability with the standard clinical tests for discrimination PJI and aseptic implant failure. A total of 50 patients undergoing revision hip and knee arthroplasty were enrolled into a prospective study. According to Musculoskeletal Infection Society (MSIS) criteria, 25 patients were classified as infected and 25 as not infected. In all patients, neutrophil CD64 index and percentage of polymorphonuclear neutrophils (PMN%) in synovial fluid, serum CRP, ESR, and serum CD64 index levels were measured preoperatively. Receiver operating characteristic (ROC) curves and the area under the curve (AUC) were analyzed for each biomarker.Aims
Methods
To establish the utility of adding the laboratory-based synovial alpha-defensin immunoassay to the traditional diagnostic work-up of a prosthetic joint infection (PJI). A group of four physicians evaluated 158 consecutive patients who were worked up for PJI, of which 94 underwent revision arthroplasty. Each physician reviewed the diagnostic data and decided on the presence of PJI according to the 2014 Musculoskeletal Infection Society (MSIS) criteria (yes, no, or undetermined). Their initial randomized review of the available data before or after surgery was blinded to each alpha-defensin result and a subsequent randomized review was conducted with each result. Multilevel logistic regression analysis assessed the effect of having the alpha-defensin result on the ability to diagnose PJI. Alpha-defensin was correlated to the number of synovial white blood cells (WBCs) and percentage of polymorphonuclear cells (%PMN).Aims
Methods
To calculate how the likelihood of obtaining measurable benefit from hip or knee arthroplasty varies with preoperative patient-reported scores. Existing UK data from 222,933 knee and 209,760 hip arthroplasty patients were used to model an individual’s probability of gaining meaningful improvement after surgery based on their preoperative Oxford Knee or Hip Score (OKS/OHS). A clinically meaningful improvement after arthroplasty was defined as ≥ 8 point improvement in OHS, and ≥ 7 in OKS.Aims
Methods
Total joint replacement (TJR) is a high-cost, high-volume procedure that impacts patients’ quality of life. Informed decisions are important for patients facing TJR. The quality of information provided by websites regarding TJR is highly variable. We aimed to measure the quality of TJR information online. We identified 10,800 websites using 18 TJR-related keywords (conditions and procedures) across the Australian, French, German and Spanish Google search engines. We used the Health on the Net (HON) toolbar to evaluate the first 150 websites downloaded for every keyword in each language. The quality of information on websites was inspected, accounting for differences by language and tertiles. We also undertook an analysis of English websites to explore types of website providers.Aims
Methods
Obtaining a balanced flexion gap with correct
femoral component rotation is one of the prerequisites for a successful
outcome after total knee replacement (TKR). Different techniques
for achieving this have been described. In this study we prospectively
compared gap-balancing versus measured resection
in terms of reliability and
The EuroQol five-dimension (EQ-5D) questionnaire is a widely used multiattribute general health questionnaire where an EQ-5D < 0 defines a state ‘worse than death’ (WTD). The aim of this study was to determine the proportion of patients awaiting total hip arthroplasty (THA) or total knee arthroplasty (TKA) in a health state WTD and to identify associations with this state. Secondary aims were to examine the effect of WTD status on one-year outcomes. A cross-sectional analysis of 2073 patients undergoing 2073 THAs (mean age 67.4 years (Aims
Patients and Methods
The aim of this study was to compare the results of 16S/28S rRNA sequencing with the erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) level, and synovial fluid analysis in the diagnosis of prosthetic joint infection (PJI). Between September 2015 and August 2016, 214 consecutive patients were enrolled. In the study population, there were 25 patients with a PJI and 189 controls. Of the PJI patients, 14 (56%) were women, and the mean age at the time of diagnosis was 65 years (38 to 83). The ESR and CRP levels were measured, and synovial fluid specimens were collected prospectively. Synovial fluid was subjected to reverse transcription polymerase chain reaction (RT-PCR)/sequence analysis targeting the 16S/28S rRNA, and to conventional culture. Laboratory personnel who were blind to the clinical information performed all tests. The diagnosis of PJI was based on the criteria of the Musculoskeletal Infection Society.Aims
Patients and Methods
The aims of this study were to report the efficacy of revision surgery for patients with co-infective bacterial and fungal prosthetic joint infections (PJIs) presenting to a single institution, and to identify prognostic factors that would guide management. A total of 1189 patients with a PJI were managed in our bone infection service between 2006 and 2015; 22 (1.85%) with co-infective bacterial and fungal PJI were included in the study. There were nine women and 13 men, with a mean age at the time of diagnosis of 64.5 years (47 to 83). Their mean BMI was 30.9 kg/m2 (24 to 42). We retrospectively reviewed the outcomes of these PJIs, after eight total hip arthroplasties and 14 total knee arthroplasties. The mean clinical follow-up was 4.1 years (1.4 to 8.8).Aims
Patients and Methods
The aim of this study was to determine the prevalence and characteristics of C-reactive protein (CRP)-negative prosthetic joint infection (PJI) and evaluate the influence of the type of infecting organism on the CRP level. A retrospective analysis of all PJIs affecting the hip or knee that were diagnosed in our institution between March 2013 and December 2016 was performed. A total of 215 patients were included. Their mean age was 71 years (Aims
Patients and Methods
The aim of this study was to establish the diagnostic accuracy
of culture of joint aspirate with and without saline injection-reaspiration. This is a retrospective analysis of 580 hip and knee aspirations
in patients who were deemed to have a moderate to high risk of infection,
and who subsequently proceeded to revision arthroplasty over a period
of 12 years. It was carried out at a large quaternary referral centre
where preoperative aspiration is routine.Aims
Patients and Methods
Increasing innovation in rapid prototyping (RP)
and additive manufacturing (AM), also known as 3D printing, is bringing
about major changes in translational surgical research. This review describes the current position in the use of additive
manufacturing in orthopaedic surgery. Cite this article:
The aims of this study were to determine the indications and
frequency of ordering a CT pulmonary angiography (CTPA) following
primary arthroplasty of the hip and knee, and to determine the number
of positive scans in these patients, the location of emboli and
the outcome for patients undergoing CTPA. We analyzed the use of CTPA, as an inpatient and up to 90 days
as an outpatient, in a cohort of patients and reviewed the medical
records and imaging for each patient undergoing CTPA.Aims
Patients and Methods
The aim of this study was to identify the incidence of positive
cultures during the second stage of a two-stage revision arthroplasty
and to analyse the association between positive cultures and an
infection-free outcome. This single-centre retrospective review of prospectively collected
data included patients with a periprosthetic joint infection (PJI)
of either the hip or the knee between 2013 and 2015, who were treated
using a standardised diagnostic and therapeutic algorithm with two-stage
exchange. Failure of treatment was assessed according to a definition
determined by a Delphi-based consensus. Logistic regression analysis
was performed to assess the predictors of positive culture and risk
factors for failure. The mean follow-up was 33 months (24 to 48).Aims
Patients and Methods
Older patients with multiple medical co-morbidities
are increasingly being offered and undergoing total joint arthroplasty
(TJA). These patients are more likely to require intensive care
support, following surgery. We prospectively evaluated the need
for intensive care admission and intervention in a consecutive series
of 738 patients undergoing elective hip and knee arthroplasty procedures.
The mean age was 60.6 years (18 to 91; 440 women, 298 men. Risk
factors, correlating with the need for critical care intervention,
according to published guidelines, were analysed to identify high-risk
patients who would benefit from post-operative critical care monitoring.
A total of 50 patients (6.7%) in our series required critical care
level interventions during their hospital stay. Six independent
multivariate clinical predictors were identified (p <
0.001)
including a history of congestive heart failure (odds ratio (OR)
24.26, 95% confidence interval (CI) 9.51 to 61.91), estimated blood
loss >
1000 mL (OR 17.36, 95% CI 5.36 to 56.19), chronic obstructive
pulmonary disease (13.90, 95% CI 4.78 to 40.36), intra-operative
use of vasopressors (OR 8.10, 95% CI 3.23 to 20.27), revision hip
arthroplasty (OR 2.71, 95% CI 1.04 to 7.04) and body mass index
>
35 kg/m2 (OR 2.70, 95% CI 123 to 5.94). The model was
then validated against an independent, previously published data
set of 1594 consecutive patients. The use of this risk stratification
model can be helpful in predicting which high-risk patients would
benefit from a higher level of monitoring and care after elective
TJA and aid hospitals in allocating precious critical care resources. Cite this article:
The aim of this study was to present data on 11 459 patients
who underwent total hip (THA), total knee (TKA) or unicompartmental
knee arthroplasty (UKA) between November 2002 and April 2014 with
aspirin as the primary agent for pharmacological thromboprophylaxis. We analysed the incidence of deep vein thrombosis (DVT) and pulmonary
embolism (PE) then compared the 90-day all-cause mortality with
the corresponding data in the National Joint Registry for England
and Wales (NJR). Aims
Patients and Methods
Total joint arthroplasty (TJA) is commonly performed in elderly
patients. Frailty, an aggregate expression of vulnerability, becomes
increasingly common with advanced age, and independently predicts
adverse outcomes and the use of resources after a variety of non-cardiac
surgical procedures. Our aim was to assess the impact of frailty
on outcomes after TJA. We analysed the impact of pre-operative frailty on death and
the use of resources after elective TJA in a population-based cohort
study using linked administrative data from Ontario, Canada.Aims
Patients and Methods
The aim of this study was to define return to
theatre (RTT) rates for elective hip and knee replacement (HR and
KR), to describe the predictors and to show the variations in risk-adjusted
rates by surgical team and hospital using national English hospital
administrative data. We examined information on 260 206 HRs and 315 249 KRs undertaken
between April 2007 and March 2012. The 90-day RTT rates were 2.1%
for HR and 1.8% for KR. Male gender, obesity, diabetes and several
other comorbidities were associated with higher odds for both index
procedures. For HR, hip resurfacing had half the odds of cement fixation
(OR = 0.58, 95% confidence intervals (CI) 0.47 to 0.71). For KR,
unicondylar KR had half the odds of total replacement (OR = 0.49,
95% CI 0.42 to 0.56), and younger ages had higher odds (OR = 2.23,
95% CI 1.65 to 3.01) for ages <
40 years compared with ages 60
to 69 years). There were more funnel plot outliers at three standard deviations
than would be expected if variation occurred on a random basis. Hierarchical modelling showed that three-quarters of the variation
between surgeons for HR and over half the variation between surgeons
for KR are not explained by the hospital they operated at or by
available patient factors. We conclude that 90-day RTT rate may
be a useful quality indicator for orthopaedics. Cite this article:
Initial stability of tibial trays is crucial for long-term success of total knee arthroplasty (TKA) in both primary and revision settings. Rotating platform (RP) designs reduce torque transfer at the tibiofemoral interface. We asked if this reduced torque transfer in RP designs resulted in subsequently reduced micromotion at the cemented fixation interface between the prosthesis component and the adjacent bone. Composite tibias were implanted with fixed and RP primary and revision tibial trays and biomechanically tested under up to 2.5 kN of axial compression and 10° of external femoral component rotation. Relative micromotion between the implanted tibial tray and the neighbouring bone was quantified using high-precision digital image correlation techniques.Objectives
Methods
The purpose of this study was to evaluate whether
the serum level of interleukin 6 (IL-6) could be used to identify the
persistence of infection after the first stage of a two-stage revision
for periprosthetic joint infection. Between 2010 and 2011, we prospectively studied 55 patients (23
men, 32 women; mean age 69.5 years; 36 to 86) with a periprosthetic
joint infection. Bacteria were identified in two intra-operative
tissue samples during re-implantation in 16 patients. These cases
were classified as representing persistent infection. To calculate a precise cut-off value which could be used in everyday
clinical practice, a 3 x 2 contingency table was constructed and
manually defined. We found that a serum IL-6 ≥ 13 pg/mL can be regarded as indicating
infection: its positive-predictive value is 90.9%. A serum IL-6 ≤ 8
pg/mL can be regarded as indicating an absence of infection: its
negative predictive value is 92.1%. The serum IL-6 level seems to be a reasonable marker for identifying
persistent infection after the first stage of a revision joint arthroplasty
and before attempting re-implantation. Cite this article:
Infection is a leading indication for revision
arthroplasty. Established criteria used to diagnose prosthetic joint infection
(PJI) include a range of laboratory tests. Leucocyte esterase (LE)
is widely used on a colorimetric reagent strip for the diagnosis
of urinary tract infections. This inexpensive test may be used for
the diagnosis or exclusion of PJI. Aspirates from 30 total hip arthroplasties
(THAs) and 79 knee arthroplasties (KA) were analysed for LE activity. Semi-quantitative
reagent strip readings of 15, 70, 125 and 500 white blood cells
(WBC) were validated against a manual synovial white cell count
(WCC). A receiver operating characteristic (ROC) curve was constructed
to determine the optimal cut-off point for the semi-quantitative
results. Based on established criteria, six THAs and 15 KAs were
classified as infected. The optimal cut-off point for the diagnosis
of PJI was 97 WBC. The closest semi-quantitative reading for a positive
result was 125 WBC, achieving a sensitivity of 81% and a specificity
of 93%. The positive and negative predictive values of the LE test
strip were 74% and 95% respectively. The LE reagent strip had a high specificity and negative predictive
value. A negative result may exclude PJI and negate the need for
further diagnostic tests. Cite this article:
The aim of our study was to describe the characteristics,
treatment, and outcomes of patients with periprosthetic joint infection
(PJI) and normal inflammatory markers after total knee arthroplasty
(TKA) and total hip arthroplasty (THA). In total 538 TKAs and 414 THAs underwent surgical treatment for
PJI and met the inclusion criteria. Pre-operative erythrocyte sedimentation
rate (ESR) and C-reactive protein level (CRP) were reviewed to identify
the seronegative cohort. An age- and gender-matched cohort was identified
from the remaining patients for comparison. Overall, 4% of confirmed
infections were seronegative (21 TKA and 17 THA). Of those who underwent
pre-operative aspiration, cultures were positive in 76% of TKAs
(n = 13) and 64% of THAs (n = 7). Cell count and differential were
suggestive of infection in 85% of TKA (n = 11) and all THA aspirates
(n = 5). The most common organism was coagulase-negative Cite this article:
We compared the length of hospitalisation, rate
of infection, dislocation of the hip and revision, and mortality following
primary hip and knee arthroplasty for osteoarthritis in patients
with Alzheimer’s disease (n = 1064) and a matched control group
(n = 3192). The data were collected from nationwide Finnish health
registers. Patients with Alzheimer’s disease had a longer peri-operative
hospitalisation (median 13 days Cite this article:
The Unified Classification System (UCS) was introduced
because of a growing need to have a standardised universal classification
system of periprosthetic fractures. It combines and simplifies many
existing classification systems, and can be applied to any fracture
around any partial or total joint replacement occurring during or
after operation. Our goal was to assess the inter- and intra-observer
reliability of the UCS in association with knee replacement when
classifying fractures affecting one or more of the femur, tibia
or patella. We used an international panel of ten orthopaedic surgeons with
subspecialty fellowship training and expertise in adult hip and
knee reconstruction (‘experts’) and ten residents of orthopaedic
surgery in the last two years of training (‘pre-experts’). They
each received 15 radiographs for evaluation. After six weeks they
evaluated the same radiographs again but in a different order. The reliability was assessed using the Kappa and weighted Kappa
values. The Kappa values for inter-observer reliability for the experts
and the pre-experts were 0.741 (95% confidence interval (CI) 0.707
to 0.774) and 0.765 (95% CI 0.733 to 0.797), respectively. The weighted
Kappa values for intra-observer reliability for the experts and
pre-experts were 0.898 (95% CI 0.846 to 0.950) and 0.878 (95% CI
0.815 to 0.942) respectively. The UCS has substantial inter-observer reliability and ‘near
perfect’ intra-observer reliability when used for periprosthetic
fractures in association with knee replacement in the hands of experienced
and inexperienced users. Cite this article:
Cut-off values with highest sensitivity and specificity
for the synovial fluid white cell and differential count will facilitate
the accurate diagnosis of infection in total knee (TKR) and total
hip replacement (THR). All patients undergoing revision TKR or THR
for suspected prosthetic joint infection between 2009 and 2011 at
two hospitals were identified. A total of 75 patients were included
with a mean age of 70.3 years (38 to 89). Synovial fluid was aspirated
pre-operatively and peri-prosthetic tissue samples were taken intra-operatively
for histological and microbiological examination. Receiver operating characteristic (ROC) plots were constructed
for white cell and differential counts in aspirated fluid. The optimal
cut-off for TKR and THR was 1590 white cells/µl and 65% neutrophilia.
The white cell count cut-off value identified for THR was notably
lower than previously quoted in the literature. A cut-off value
for white cell count in synovial aspirate in suspected prosthetic
joint infection of between 1100 and 1700 white cells/µl is likely
to be applicable to both THR and TKR. Cite this article:
This prospective study evaluates the role of new laboratory markers in the diagnosis of deep implant infection in 78 patients (41 men and 37 women) with a revision total knee or hip replacement. The mean age at the time of operation was 64.0 years (19 to 90). Intra-operative cultures showed that 21 patients had a septic and 57 an aseptic total joint replacement. The white blood cell count, the erythrocyte sedimentation rate and levels of C-reactive protein, interleukin-6, procalcitonin and tumour necrosis factor (TNF)-α were measured in blood samples before operation. The diagnostic cut-off values were determined by Received Operating Characteristic curve analysis. C-reactive protein (>
3.2 md/dl) and interleukin-6 (>
12 pg/ml) have the highest sensitivity (0.95). Interleukin-6 is less specific than C-reactive protein (0.87 The combination of C-reactive protein and interleukin-6 measurement provide excellent screening tests for infection of a deep implant. A highly specific marker such as procalcitonin and pre-operative aspiration of the joint might be useful in identifying patients with true positive C-reactive protein and/or interleukin-6 levels.
We have developed a novel method of calculating the radiological magnification of the hip using two separate radio-opaque markers. We recruited 74 patients undergoing radiological assessment following total hip replacement. Both the new double marker and a conventional single marker were used by the radiographer at the time of x-ray. The predicted magnification according to each marker was calculated, as was the true radiological magnification of the components. The correlation between true and predicted magnification was good using the double marker (r = 0.90, n = 74, p <
0.001), but only moderate for the single marker (r = 0.50, n = 63, p <
0.001). The median error was significantly less for the double marker than for the single (1.1% The double marker method appears to be superior to the single marker method when used in the clinical environment.
In order to compare the effect of oral apixaban
(a factor Xa inhibitor) with subcutaneous enoxaparin on major venous
thromboembolism and major and non-major clinically relevant bleeding
after total knee and hip replacement, we conducted a pooled analysis
of two previously reported double-blind randomised studies involving 8464
patients. One group received apixaban 2.5 mg twice daily (plus placebo
injection) starting 12 to 24 hours after operation, and the other
received enoxaparin subcutaneously once daily (and placebo tablets)
starting 12 hours (± 3) pre-operatively. Each regimen was continued
for 12 days ( Apixaban 2.5 mg twice daily is more effective than enoxaparin
40 mg once daily without increased bleeding.
Using the General Practice Research Database, we examined the temporal changes in the rates of primary total hip (THR) and total knee (TKR) replacement, the age at operation and the female-to-male ratio between 1991 and 2006 in the United Kingdom. We identified 27 113 patients with THR and 23 843 with TKR. The rate of performance of THR and TKR had increased significantly (p <
0.0001 for both) during the 16-year period and was greater for TKR, especially in the last five years. The mean age at operation was greater for women than for men and had remained stable throughout the period of study. The female-to-male ratio was higher for THR and TKR and had remained stable. The data support the notion that the rate of joint replacement is increasing in the United Kingdom with the rate of TKR rising at the highest rate. The perception that the mean age for TKR has decreased over time is not supported.
The National Institute for Clinical Excellence (NICE) produces recommendations on appropriate treatment within the National Health Service (NHS) in England and Wales. The NICE guidelines on prophylaxis for venous thromboembolism in orthopaedic surgery recommend that all patients be offered a low molecular weight heparin (LMWH). The linked hospital episode statistics of 219 602 patients were examined to determine the rates of complications following lower limb arthroplasty for the 12-month periods prior to and following the publication of these guidelines. These were compared with data from the National Joint Registry (England and Wales) regarding the use of LMWH during the same periods. There was a significant increase in the reported use of LMWH (59.5% to 67.6%, p <
0.001) following the publication of the guidelines. However, the 90-day venous thromboembolism events actually increased slightly following total hip replacement (THR, 1.69% to 1.84%, p = 0.06) and remained unchanged following total knee replacement (TKR, 1.99% to 2.04%). Return to theatre in the first 30 days for infection did not show significant changes. There was an increase in the number of patients diagnosed with thrombocytopenia, which was significant following THR (0.11% to 0.16%, p = 0.04). The recommendations from NICE are based on predicted reductions in venous thromboembolism events, reducing morbidity, mortality and costs to the NHS. The early results in orthopaedic patients do not support these predictions, but do show an increase in complications.
As part of the government’s initiative to reduce waiting times for major joint surgery in Wales, the Cardiff and Vale NHS Trust sent 224 patients (258 knees) to the NHS Treatment Centre in Weston-Super-Mare for total knee replacement. The Kinemax total knee replacement system was used in all cases. The cumulative survival rate at three years was 79.2% (95% confidence interval (CI) 69.2 to 86.8) using re-operation for any cause as an endpoint and 85.3% (95% CI 75.9 to 91.8) using aseptic revision as an endpoint. This is significantly worse than that recorded in the published literature. These poor results have resulted in a significant impact on our service.
Bone cements produced by different manufacturers vary in their mechanical properties and antibiotic elution characteristics. Small changes in the formulation of a bone cement, which may not be apparent to surgeons, can also affect these properties. The supplier of Palacos bone cement with added gentamicin changed in 2005. We carried out a study to examine the mechanical characteristics and antibiotic elution of Schering-Plough Palacos, Heraeus Palacos and Depuy CMW Smartset bone cements. Both Heraeus Palacos and Smartset bone cements performed significantly better than Schering-Plough Palacos in terms of mechanical characteristics, with and without additional vancomycin (p <
0.001). All cements show a deterioration in flexural strength with increasing addition of vancomycin, albeit staying above ISO minimum levels. Both Heraeus Palacos and Smartset elute significantly more gentamicin cumulatively than Schering-Plough Palacos. Smartset elutes significantly more vancomycin cumulatively than Heraeus Palacos. The improved antibiotic elution characteristics of Smartset and Heraeus Palacos are not associated with a deterioration in mechanical properties. Although marketed as the ‘original’ Palacos, Heraeus Palacos has significantly altered mechanical and antibiotic elution characteristics compared with the most commonly-used previous version.