Advertisement for orthosearch.org.uk
Results 1 - 36 of 36
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 221 - 226
1 Mar 2023
Wilton T Skinner JA Haddad FS

Recent publications have drawn attention to the fact that some brands of joint replacement may contain variants which perform significantly worse (or better) than their ‘siblings’. As a result, the National Joint Registry has performed much more detailed analysis on the larger families of knee arthroplasties in order to identify exactly where these differences may be present and may hitherto have remained hidden. The analysis of the Nexgen knee arthroplasty brand identified that some posterior-stabilized combinations have particularly high revision rates for aseptic loosening of the tibia, and consequently a medical device recall has been issued for the Nexgen ‘option’ tibial component which was implicated. More elaborate signal detection is required in order to identify such variation in results in a routine fashion if patients are to be protected from such variation in outcomes between closely related implant types. Cite this article: Bone Joint J 2023;105-B(3):221–226


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 356 - 360
15 Mar 2023
Baker PN Jeyapalan R Jameson SS

The importance of registries has been brought into focus by recent UK national reports focusing on implant (Cumberlege) and surgeon (Paterson) performance. National arthroplasty registries provide real-time, real-world information about implant, hospital, and surgeon performance and allow case identification in the event of product recall or adverse surgical outcomes. They are a valuable resource for research and service improvement given the volume of data recorded and the longitunidal nature of data collection. This review discusses the current value of registry data as it relates to both clinical practice and research.

Cite this article: Bone Joint J 2023;105-B(4):356–360.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 312 - 318
1 Apr 2024
Sheth NP Jones SA Sanghavi SA Manktelow A

The advent of modular porous metal augments has ushered in a new form of treatment for acetabular bone loss. The function of an augment can be seen as reducing the size of a defect or reconstituting the anterosuperior/posteroinferior columns and/or allowing supplementary fixation. Depending on the function of the augment, the surgeon can decide on the sequence of introduction of the hemispherical shell, before or after the augment. Augments should always, however, be used with cement to form a unit with the acetabular component. Given their versatility, augments also allow the use of a hemispherical shell in a position that restores the centre of rotation and biomechanics of the hip. Progressive shedding or the appearance of metal debris is a particular finding with augments and, with other radiological signs of failure, should be recognized on serial radiographs. Mid- to long-term outcomes in studies reporting the use of augments with hemispherical shells in revision total hip arthroplasty have shown rates of survival of > 90%. However, a higher risk of failure has been reported when augments have been used for patients with chronic pelvic discontinuity.

Cite this article: Bone Joint J 2024;106-B(4):312–318.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1039 - 1043
1 Oct 2024
Luo TD Kayani B Magan A Haddad FS

The subject of noise in the operating theatre was recognized as early as 1972 and has been compared to noise levels on a busy highway. While noise-induced hearing loss in orthopaedic surgery specifically has been recognized as early as the 1990s, it remains poorly studied. As a result, there has been renewed focus in this occupational hazard. Noise level is typically measured in decibels (dB), whereas noise adjusted for human perception uses A-weighted sound levels and is expressed in dBA. Mean operating theatre noise levels range between 51 and 75 dBA, with peak levels between 80 and 119 dBA. The greatest sources of noise emanate from powered surgical instruments, which can exceed levels as high as 140 dBA. Newer technology, such as robotic-assisted systems, contribute a potential new source of noise. This article is a narrative review of the deleterious effects of prolonged noise exposure, including noise-induced hearing loss in the operating theatre team and the patient, intraoperative miscommunication, and increased cognitive load and stress, all of which impact the surgical team’s overall performance. Interventions to mitigate the effects of noise exposure include the use of quieter surgical equipment, the implementation of sound-absorbing personal protective equipment, or changes in communication protocols. Future research endeavours should use advanced research methods and embrace technological innovations to proactively mitigate the effects of operating theatre noise.

Cite this article: Bone Joint J 2024;106-B(10):1039–1043.


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1104 - 1109
1 Oct 2022
Hansjee S Giebaly DE Shaarani SR Haddad FS

We aim to explore the potential technologies for monitoring and assessment of patients undergoing arthroplasty by examining selected literature focusing on the technology currently available and reflecting on possible future development and application. The reviewed literature indicates a large variety of different hardware and software, widely available and used in a limited manner, to assess patients’ performance. There are extensive opportunities to enhance and integrate the systems which are already in existence to develop patient-specific pathways for rehabilitation.

Cite this article: Bone Joint J 2022;104-B(10):1104–1109.


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 430 - 434
1 May 2024
Eardley WGP


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 307 - 311
1 Apr 2024
Horner D Hutchinson K Bretherton CP Griffin XL


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 843 - 849
1 Aug 2023
Grandhi TSP Fontalis A Raj RD Kim WJ Giebaly DE Haddad FS

Telehealth has the potential to change the way we approach patient care. From virtual consenting to reducing carbon emissions, costs, and waiting times, it is a powerful tool in our clinical armamentarium. There is mounting evidence that remote diagnostic evaluation and decision-making have reached an acceptable level of accuracy and can safely be adopted in orthopaedic surgery. Furthermore, patients’ and surgeons’ satisfaction with virtual appointments are comparable to in-person consultations. Challenges to the widespread use of telehealth should, however, be acknowledged and include the cost of installation, training, maintenance, and accessibility. It is also vital that clinicians are conscious of the medicolegal and ethical considerations surrounding the medium and adhere strictly to the relevant data protection legislation and storage framework. It remains to be seen how organizations harness the full spectrum of the technology to facilitate effective patient care.

Cite this article: Bone Joint J 2023;105-B(8):843–849.


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 911 - 914
1 Aug 2022
Prijs J Liao Z Ashkani-Esfahani S Olczak J Gordon M Jayakumar P Jutte PC Jaarsma RL IJpma FFA Doornberg JN

Artificial intelligence (AI) is, in essence, the concept of ‘computer thinking’, encompassing methods that train computers to perform and learn from executing certain tasks, called machine learning, and methods to build intricate computer models that both learn and adapt, called complex neural networks. Computer vision is a function of AI by which machine learning and complex neural networks can be applied to enable computers to capture, analyze, and interpret information from clinical images and visual inputs. This annotation summarizes key considerations and future perspectives concerning computer vision, questioning the need for this technology (the ‘why’), the current applications (the ‘what’), and the approach to unlocking its full potential (the ‘how’).

Cite this article: Bone Joint J 2022;104-B(8):911–914.


The Bone & Joint Journal
Vol. 99-B, Issue 1_Supple_A | Pages 8 - 13
1 Jan 2017
Haynes J Barrack RL Nam D

Aims. The purpose of this article was to review the current literature pertaining to the use of mobile compression devices (MCDs) for venous thromboembolism (VTE) following total joint arthroplasty (TJA), and to discuss the results of data from our institution. Patients and Methods. Previous studies have illustrated higher rates of post-operative wound complications, re-operation and re-admission with the use of more aggressive anticoagulation regimens, such as warfarin and factor Xa inhibitors. This highlights the importance of the safety, as well as efficacy, of the chemoprophylactic regimen. Results. Studies have shown a symptomatic VTE rate of 0.92% with use of MCDs for prophylaxis, which is comparable with rates seen with more aggressive anticoagulation protocols. A prior prospective study found that use of a pre-operative risk stratification protocol based on personal history of deep vein thrombosis, family history of VTE, active cancer, or a hypercoaguable state allowed for the avoidance of aggressive prophylactic anticoagulation in over 70% of patients while maintaining a low incidence of symptomatic VTE. Conclusion. Further investigation is needed into the role of aspirin in VTE prophylaxis as well as the efficacy of MCDs as stand-alone prophylactic treatment. Cite this article: Bone Joint J 2017;99-B(1 Supple A):8–13


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 809 - 812
1 May 2021
Farhan-Alanie MM Trompeter AJ Wall PDH Costa ML

The use of tourniquets in lower limb trauma surgery to control bleeding and improve the surgical field is a long established practice. In this article, we review the evidence relating to harms and benefits of tourniquet use in lower limb fracture fixation surgery and report the results of a survey on current tourniquet practice among trauma surgeons in the UK.


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 661 - 663
1 Jun 2020
Meek RMD Treacy R Manktelow A Timperley JA Haddad FS

In this review, we discuss the evidence for patients returning to sport after hip arthroplasty. This includes the choices regarding level of sporting activity and revision or complications, the type of implant, fixation and techniques of implantation, and how these choices relate to health economics. It is apparent that despite its success over six decades, hip arthroplasty has now evolved to accommodate and support ever-increasing patient demands and may therefore face new challenges.

Cite this article: Bone Joint J 2020;102-B(6):661–663.


Bone & Joint Open
Vol. 1, Issue 7 | Pages 359 - 363
9 Jul 2020
Teo THL Tan BJ Loo WL Yeo AKS Dinesh SK

The COVID-19 pandemic creates unique challenges in the practice of spinal surgery. We aim to show how the use of a high-definition 3D digital exoscope can help streamline workflows, and protect both patients and healthcare staff.


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1476 - 1478
1 Dec 2019
Bayliss L Jones LD

This annotation briefly reviews the history of artificial intelligence and machine learning in health care and orthopaedics, and considers the role it will have in the future, particularly with reference to statistical analyses involving large datasets.

Cite this article: Bone Joint J 2019;101-B:1476–1478


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 432 - 435
1 Apr 2018
Murray DW Parkinson RW

Unicompartmental knee arthroplasty (UKA) has numerous advantages over total knee arthroplasty (TKA) and one disadvantage, the higher revision rate. The best way to minimize the revision rate is for surgeons to use UKA for at least 20% of their knee arthroplasties. To achieve this, they need to learn and apply the appropriate indications and techniques. This would decrease the revision rate and increase the number of UKAs which were implanted, which would save money and patients would benefit from improved outcomes over their lifetime.

Cite this article: Bone Joint J 2018;100-B:432–5.


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1264 - 1269
1 Oct 2018
Thomas AM Simmons MJ

Deep infection was identified as a serious complication in the earliest days of total hip arthroplasty. It was identified that airborne contamination in conventional operating theatres was the major contributing factor. As progress was made in improving the engineering of operating theatres, airborne contamination was reduced. Detailed studies were carried out relating airborne contamination to deep infection rates.

In a trial conducted by the United Kingdom Medical Research Council (MRC), it was found that the use of ultra-clean air (UCA) operating theatres was associated with a significant reduction in deep infection rates. Deep infection rates were further reduced by the use of a body exhaust system. The MRC trial also included a detailed microbiology study, which confirmed the relationship between airborne contamination and deep infection rates.

Recent observational evidence from joint registries has shown that in contemporary practice, infection rates remain a problem, and may be getting worse. Registry observations have also called into question the value of “laminar flow” operating theatres.

Observational evidence from joint registries provides very limited evidence on the efficacy of UCA operating theatres. Although there have been some changes in surgical practice in recent years, the conclusions of the MRC trial remain valid, and the use of UCA is essential in preventing deep infection.

There is evidence that if UCA operating theatres are not used correctly, they may have poor microbiological performance. Current UCA operating theatres have limitations, and further research is required to update them and improve their microbiological performance in contemporary practice.

Cite this article: Bone Joint J 2018;100-B:1264–9.


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 566 - 569
1 May 2018
White TO

The posterior malleolus of the ankle is the object of increasing attention, with considerable enthusiasm for CT scanning and surgical fixation, as expressed in a recent annotation in The Bone & Joint Journal. Undoubtedly, fractures with a large posterior malleolar fragment that allow posterior talar subluxation from the mortise are served better by fixation. However, in all other situations, the existing literature does not support this widespread change in practice. The available biomechanical evidence shows that the posterior malleolus has little part to play in the stability or contact stresses of the ankle joint. Radiographic studies have not shown that CT scanning offers helpful information on pathoanatomical classification, case selection, or prognosis, or that scanning improves the likelihood of an adequate surgical reduction. Clinical studies have not shown any improvement in patient outcome after surgical fixation, and have confirmed that the inevitable consequence of increased intervention is an increased rate of complications. A careful and thoughtful evaluation of indications, risks, and benefits of this fashionable concept is required to ensure that we are deploying valuable resources with efficacy, and that we do no harm.

Cite this article: Bone Joint J 2018;100-B:566–9.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 708 - 713
1 Jun 2017
Rushton PRP Siddique I Crawford R Birch N Gibson MJ Hutton MJ

The MAGnetic Expansion Control (MAGEC) system is used increasingly in the management of early-onset scoliosis. Good results have been published, but there have been recent reports identifying implant failures that may be associated with significant metallosis surrounding the implants. This article aims to present the current knowledge regarding the performance of this implant, and the potential implications and strategies that may be employed to identify and limit any problems.

We urge surgeons to apply caution to patient and construct selection; engage in prospective patient registration using a spine registry; ensure close clinical monitoring until growth has ceased; and send all explanted MAGEC rods for independent analysis.

The MAGEC system may be a good instrumentation system for the treatment of early-onset scoliosis. However, it is innovative and like all new technology, especially when deployed in a paediatric population, robust systems to assess long-term outcome are required to ensure that patient safety is maintained.

Cite this article: Bone Joint J 2017;99-B:708–13.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 892 - 900
1 Jul 2016
Atrey A Heylen S Gosling O Porteous MJL Haddad FS

Joint replacement of the hip and knee remain very satisfactory operations. They are, however, expensive. The actual manufacturing of the implant represents only 30% of the final cost, while sales and marketing represent 40%. Recently, the patents on many well established and successful implants have expired. Companies have started producing and distributing implants that purport to replicate existing implants with good long-term results.

The aims of this paper are to assess the legality, the monitoring and cost saving implications of such generic implants. We also assess how this might affect the traditional orthopaedic implant companies.

Cite this article: Bone Joint J 2016;98-B:892–900.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 6 - 9
1 Jan 2016
Fillingham Y Jacobs J

The continual cycle of bone formation and resorption is carried out by osteoblasts, osteocytes, and osteoclasts under the direction of the bone-signaling pathway. In certain situations the host cycle of bone repair is insufficient and requires the assistance of bone grafts and their substitutes. The fundamental properties of a bone graft are osteoconduction, osteoinduction, osteogenesis, and structural support. Options for bone grafting include autogenous and allograft bone and the various isolated or combined substitutes of calcium sulphate, calcium phosphate, tricalcium phosphate, and coralline hydroxyapatite. Not all bone grafts will have the same properties. As a result, understanding the requirements of the clinical situation and specific properties of the various types of bone grafts is necessary to identify the ideal graft. We present a review of the bone repair process and properties of bone grafts and their substitutes to help guide the clinician in the decision making process.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):6–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 611 - 616
1 May 2010
Treasure T Chong L Sharpin C Wonderling D Head K Hill J

Following the publication in 2007 of the guidelines from the National Institute for Health and Clinical Excellence (NICE) for prophylaxis against venous thromboembolism (VTE) for patients undergoing surgery, concerns were raised by British orthopaedic surgeons as to the appropriateness of the recommendations for their clinical practice. In order to address these concerns NICE and the British Orthopaedic Association agreed to engage a representative panel of orthopaedic surgeons in the process of developing expanded VTE guidelines applicable to all patients admitted to hospital. The functions of this panel were to review the evidence and to consider the applicability and implications in orthopaedic practice in order to advise the main Guideline Development Group in framing recommendations.

The panel considered both direct and indirect evidence of the safety and efficacy, the cost-effectiveness of prophylaxis and its implication in clinical practice for orthopaedic patients. We describe the process of selection of the orthopaedic panel, the evidence considered and the contribution of the panel to the latest guidelines from NICE on the prophylaxis against VTE, published in January 2010.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 28 - 31
1 Jan 2012
Kearney RS Costa ML

Rupture of the tendo Achillis is a common injury with a rising incidence. Traditionally the key question following this injury has been whether or not to operate. However a contemporary Cochrane review highlighted that the method of rehabilitation may also have an important contribution to the outcome. Since this review, various early weight-bearing rehabilitation protocols have been described. Currently evidence points to the use of early functional rehabilitation, regardless of operative or non-operative management. However, there is no consensus on which exact functional rehabilitation protocol should be used. Future research should be directed towards improving our understanding of how the different rehabilitative components interact in the tendo Achillis as it heals.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 23 - 27
1 Jan 2012
Uzoigwe CE Middleton RG

Radiological imaging is necessary in a wide variety of trauma and elective orthopaedic operations. The evolving orthopaedic workforce includes an increasing number of pregnant workers. Current legislation in the United Kingdom, Europe and United States allows them to choose their degree of participation, if any, with fluoroscopic procedures. For those who wish to engage in radiation-prone procedures, specific regulations apply to limit the radiation dose to the pregnant worker and unborn child.

This paper considers those aspects of radiation protection, the potential effects of exposure to radiation in pregnancy and the dose of radiation from common orthopaedic procedures, which are important for safe clinical practice.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 294 - 303
1 Mar 2009
Lindner T Kanakaris NK Marx B Cockbain A Kontakis G Giannoudis PV

Failure of fixation is a common problem in the treatment of osteoporotic fractures around the hip. The reinforcement of bone stock or of fixation of the implant may be a solution. Our study assesses the existing evidence for the use of bone substitutes in the management of these fractures in osteoporotic patients. Relevant publications were retrieved through Medline research and further scrutinised. Of 411 studies identified, 22 met the inclusion criteria, comprising 12 experimental and ten clinical reports. The clinical studies were evaluated with regard to their level of evidence. Only four were prospective and randomised.

Polymethylmethacrylate and calcium-phosphate cements increased the primary stability of the implant-bone construct in all experimental and clinical studies, although there was considerable variation in the design of the studies. In randomised, controlled studies, augmentation of intracapsular fractures of the neck of the femur with calcium-phosphate cement was associated with poor long-term results. There was a lack of data on the long-term outcome for trochanteric fractures. Because there were only a few, randomised, controlled studies, there is currently poor evidence for the use of bone cement in the treatment of fractures of the hip.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1046 - 1049
1 Aug 2005
Shepperd JAN Apthorp H


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 297 - 301
1 Mar 2012
Haddad FS Konan S

An international faculty of orthopaedic surgeons presented their work on the current challenges in hip surgery at the London Hip Meeting which was attended by over 400 delegates. The topics covered included femoroacetabular impingement, thromboembolic phenomena associated with hip surgery, bearing surfaces (including metal-on-metal articulations), outcomes of hip replacement surgery and revision hip replacement. We present a concise report of the current opinions on hip surgery from this meeting with appropriate references to the current literature.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1195 - 1202
1 Sep 2010
Moran CJ Shannon FJ Barry FP O’Byrne JM O’Brien T Curtin W

Orthopaedic surgery is in an exciting transitional period as modern surgical interventions, implants and scientific developments are providing new therapeutic options. As advances in basic science and technology improve our understanding of the pathology and repair of musculoskeletal tissue, traditional operations may be replaced by newer, less invasive procedures which are more appropriately targeted at the underlying pathophysiology. However, evidence-based practice will remain a basic requirement of care. Orthopaedic surgeons can and should remain at the forefront of the development of novel therapeutic interventions and their application. Progression of the potential of bench research into an improved array of orthopaedic treatments in an effective yet safe manner will require the development of a subgroup of specialists with extended training in research to play an important role in bridging the gap between laboratory science and clinical practice. International regulations regarding the introduction of new biological treatments will place an additional burden on the mechanisms of this translational process, and orthopaedic surgeons who are trained in science, surgery and the regulatory environment will be essential. Training and supporting individuals with these skills requires special consideration and discussion by the orthopaedic community.

In this paper we review some traditional approaches to the integration of orthopaedic science and surgery, the therapeutic potential of current regenerative biomedical science for cartilage repair and ways in which we may develop surgeons with the skills required to translate scientific discovery into effective and properly assessed orthopaedic treatments.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 454 - 458
1 Apr 2012
Goldberg AJ MacGregor A Spencer SA

With the established success of the National Joint Registry and the emergence of a range of new national initiatives for the capture of electronic data in the National Health Service, orthopaedic surgery in the United Kingdom has found itself thrust to the forefront of an information revolution. In this review we consider the benefits and threats that this revolution poses, and how orthopaedic surgeons should marshal their resources to ensure that this is a force for good.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1187 - 1191
1 Sep 2005
Pitts D Rowley DI Sher JL


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1493 - 1497
1 Nov 2010
Simpson JM Villar RN

We review the history and literature of hip resurfacing arthroplasty. Resurfacing and the science behind it continues to evolve. Recent results, particularly from the national arthroplasty registers, have spread disquiet among both surgeons and patients. A hip resurfacing arthroplasty is not a total hip replacement, but should perhaps be seen as a means of delaying it. The time when hip resurfacing is offered to a patient may be different from that for a total hip replacement. The same logic can apply to the timing of revision surgery. Consequently, the comparison of resurfacing with total hip replacement may be a false one. Nevertheless, the need for innovative solutions for young arthroplasty patients is clear. Total hip replacement can be usefully delayed in many of these patients by the use of hip resurfacing arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 580 - 585
1 May 2007
Crowley DJ Kanakaris NK Giannoudis PV

Modern principles for the treatment of open fractures include stabilisation of the bone and management of the soft tissues. Wound debridement and irrigation is thought to be the mainstay in reducing the incidence of infection. Although numerous studies on animals and humans have focused on the type of irrigation performed, little is known of the factors which influence irrigation. This paper evaluates the evidence, particularly with regard to additives and the mode of delivery of irrigation fluid.

Normal saline should be used and although many antiseptics and antibiotics have been employed, no consensus has been reached as to the ideal additive. Despite the advocates of high-pressure methods highlighting the improved dilutional ability of such techniques, the results are inconclusive and these irrigation systems are not without complications.

New systems for debridement are currently being investigated, and an ideal method has yet to be determined.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1545 - 1549
1 Dec 2009
Migliore A Perrini MR Romanini E Fella D Cavallo A Cerbo M Jefferson T

This study evaluated the feasibility of using published data from more than one register to define the performance of different hip implants. In order to obtain estimates of performance for specific types of hip system from different register, we analysed data from the annual reports of five national and one Italian regional register. We extracted the number of implants and rates of implant survival at different periods of follow-up. Our aim was to assess whether estimates of cumulative survival rate were comparable with data from registers from different countries, and our conclusion was that such a comparison could only be performed incompletely.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 903 - 910
1 Jul 2005
Sikorski JM Blythe MC


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1414 - 1421
1 Nov 2008
Arya AP Klenerman L

The Jaipur foot was developed for barefoot amputees by Professor P. K. Sethi. He used local artisans and readily available materials. The prosthesis was cheap and could be made in one hour. It enabled amputees to work in rural conditions, muddy and wet fields and to climb trees. It has been widely used in India, South East Asia and Africa, where local variations to the design have now been made.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 8 - 15
1 Jan 2009
Bardakos NV Villar RN

Advances in hip arthroscopy have renewed interest in the ligamentum teres. Considered by many to be a developmental vestige, it is now recognised as a significant potential source of pain and mechanical symptoms arising from the hip joint. Despite improvements in imaging, arthroscopy remains the optimum method of diagnosing lesions of the ligamentum teres. Several biological or mechanical roles have been proposed for the ligament. Unless these are disproved, the use of surgical procedures that sacrifice the ligamentum teres, as in surgical dislocation of the hip, should be carefully considered. This paper provides an update on the development, structure and function of the ligamentum teres, and discusses associated clinical implications.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 717 - 720
1 Jun 2007
Zhen-Sheng M Hong-Ju Z Tao Y Gang R Guo-Sheng D Yong-Hua W

Online case discussion may be used for the education of orthopaedic surgeons. The authors developed a website for discussing orthopaedic cases nine years ago and describe its management. It currently has 20 000 registered users.