Penetration of the dorsal screw when treating
distal radius fractures with volar locking plates is an avoidable complication
that causes lesions of the
Aims
To analyze the short-term outcome of two types of total wrist arthroplasty (TWA) in terms of wrist function, migration, and periprosthetic bone behaviour.
Methods
A total of 40 patients suffering from non-rheumatoid wrist arthritis were enrolled in a randomized controlled trial comparing the ReMotion and Motec TWAs. Patient-rated and functional outcomes, radiological changes, blood metal ion levels, migration measured by model-based radiostereometric analysis (RSA), bone mineral density (BMD) measured by dual-energy X-ray absorptiometry (DXA), complications, loosening, and revision rates at two years were compared.
Aims
The aim of this study was to investigate whether intraoperative 3D fluoroscopic imaging outperforms dorsal tangential views in the detection of dorsal cortex screw penetration after volar plating of an intra-articular distal radial fracture, as identified on postoperative CT imaging.
Methods
A total of 165 prospectively enrolled patients who underwent volar plating for an intra-articular distal radial fracture were retrospectively evaluated to study three intraoperative imaging protocols: 1) standard 2D fluoroscopic imaging with anteroposterior (AP) and elevated lateral images (n = 55); 2) 2D fluoroscopic imaging with AP, lateral, and dorsal tangential views images (n = 50); and 3) 3D fluoroscopy (n = 60). Multiplanar reconstructions of postoperative CT scans served as the reference standard.
Aims
Total wrist arthrodesis (TWA) produces a spectrum of outcomes. We investigated this by reviewing 77 consecutive TWA performed for inflammatory and post-traumatic arthropathies, wrist instability and as a salvage procedure.
Patients and Methods
All operations were performed by a single surgeon using a specifically designed pre-contoured dorsally applied non-locking wrist arthrodesis plate at a single centre.
Aims
The aims of this study were to evaluate the clinical and radiological outcomes of the Universal-2 total wrist arthroplasty (TWA) in patients with rheumatoid arthritis.
Patients and Methods
This was a retrospective review of all 95 Universal-2 TWAs which were performed in our institution between 2003 to 2012 in patients with rheumatoid arthritis. A total of six patients were lost to follow-up and two died of unrelated causes. A total of ten patients had bilateral procedures. Accordingly, 75 patients (85 TWAs) were included in the study. There were 59 women and 16 men with a mean age of 59 years (26 to 86). The mean follow-up was 53 months (24 to 120). Clinical assessment involved recording pain on a visual analogue score, range of movement, grip strength, the Quick Disabilities of the Arm, Shoulder and Hand (DASH) and Wrightington wrist scores. Any adverse effects were documented with particular emphasis on residual pain, limitation of movement, infection, dislocation and the need for revision surgery.
Radiographic assessment was performed pre-operatively and at three, six and 12 months post-operatively, and annually thereafter. Arthroplasties were assessed for distal row intercarpal fusion and loosening. Radiolucent zones around the components were documented according to a system developed at our institution.
The aims of this study were to assess the efficacy of a newly designed radiological technique (the radial groove view) for the detection of protrusion of screws in the groove for the extensor pollicis longus tendon (EPL) during plating of distal radial fractures. We also aimed to determine the optimum position of the forearm to obtain this view. We initially analysed the anatomy of the EPL groove by performing three-dimensional CT on 51 normal forearms. The mean horizontal angle of the groove was 17.8° (14° to 23°). We found that the ideal position of the fluoroscopic beam to obtain this view was 20° in the horizontal plane and 5° in the sagittal plane.
We then intra-operatively assessed the use of the radial groove view for detecting protrusion of screws in the EPL groove in 93 fractures that were treated by volar plating. A total of 13 protruding screws were detected. They were changed to shorter screws and these patients underwent CT scans of the wrist immediately post-operatively. There remained one screw that was protruding. These findings suggest that the use of the radial groove view intra-operatively is a good method of assessing the possible protrusion of screws into the groove of EPL when plating a fracture of the distal radius.
Cite this article: