Advertisement for orthosearch.org.uk
Results 1 - 100 of 132
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 112 - 115
1 Jul 2020
Waly FJ Garbuz DS Greidanus NV Duncan CP Masri BA

Aims. The practice of overlapping surgery has been increasing in the delivery of orthopaedic surgery, aiming to provide efficient, high-quality care. However, there are concerns about the safety of this practice. The purpose of this study was to examine the safety and efficacy of a model of partially overlapping surgery that we termed ‘swing room’ in the practice of primary total hip (THA) and knee arthroplasty (TKA). Methods. A retrospective review of prospectively collected data was carried out on patients who underwent primary THA and TKA between 2006 and 2017 in two academic centres. Cases were stratified as partially overlapping (swing room), in which the surgeon is in one operating room (OR) while the next patient is being prepared in another, or nonoverlapping surgery. The demographic details of the patients which were collected included operating time, length of stay (LOS), postoperative complications within six weeks of the procedure, unplanned hospital readmissions, and unplanned reoperations. Fisher's exact, Wilcoxon rank-sum tests, chi-squared tests, and logistic regression analysis were used for statistical analysis. Results. A total of 12,225 cases performed at our institution were included in the study, of which 10,596 (86.6%) were partially overlapping (swing room) and 1,629 (13.3%) were nonoverlapping. There was no significant difference in the mean age, sex, body mass index (BMI), side, and LOS between the two groups. The mean operating time was significantly shorter in the swing room group (58.2 minutes) compared with the nonoverlapping group (62.8 minutes; p < 0.001). There was no significant difference in the rates of complications, readmission and reoperations (p = 0.801 and p = 0.300, respectively) after adjusting for baseline American Society of Anesthesiologists scores. Conclusion. The new ‘swing room’ model yields similar short-term outcomes without an increase in complication rates compared with routine single OR surgery in patients undergoing primary THA or TKA. Cite this article: Bone Joint J 2020;102-B(7 Supple B):112–115


Bone & Joint Research
Vol. 5, Issue 6 | Pages 206 - 214
1 Jun 2016
Malak TT Broomfield JAJ Palmer AJR Hopewell S Carr A Brown C Prieto-Alhambra D Glyn-Jones S

Objectives. High failure rates of metal-on-metal hip arthroplasty implants have highlighted the need for more careful introduction and monitoring of new implants and for the evaluation of the safety of medical devices. The National Joint Registry and other regulatory services are unable to detect failing implants at an early enough stage. We aimed to identify validated surrogate markers of long-term outcome in patients undergoing primary total hip arthroplasty (THA). Methods. We conducted a systematic review of studies evaluating surrogate markers for predicting long-term outcome in primary THA. Long-term outcome was defined as revision rate of an implant at ten years according to National Institute of Health and Care Excellence guidelines. We conducted a search of Medline and Embase (OVID) databases. Separate search strategies were devised for the Cochrane database and Google Scholar. Each search was performed to include articles from the date of their inception to June 8, 2015. Results. Our search strategy identified 1082 studies of which 115 studies were included for full article review. Following review, 17 articles were found that investigated surrogate markers of long-term outcome. These included one systematic review, one randomised control trial (RCT), one case control study and 13 case series. Validated surrogate markers included Radiostereometric Analysis (RSA) and Einzel-Bild-Röntgen-Analyse (EBRA), each measuring implant migration and wear. We identified five RSA studies (one systematic review and four case series) and four EBRA studies (one RCT and three case series). Patient Reported Outcome Measures (PROMs) at six months have been investigated but have not been validated against long-term outcomes. Conclusions. This systematic review identified two validated surrogate markers of long-term primary THA outcome: RSA and EBRA, each measuring implant migration and wear. We recommend the consideration of RSA in the pre-market testing of new implants. EBRA can be used to investigate acetabular wear but not femoral migration. Further studies are needed to validate the use of PROMs for post-market surveillance. Cite this article: T. T. Malak, J. A. J. Broomfield, A. J. R. Palmer, S. Hopewell, A. Carr, C. Brown, D. Prieto-Alhambra, S. Glyn-Jones. Surrogate markers of long-term outcome in primary total hip arthroplasty: A systematic review. Bone Joint Res 2016;5:206–214. DOI: 10.1302/2046-3758.56.2000568


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1005 - 1012
1 Aug 2008
Tsiridis E Pavlou G Charity J Tsiridis E Gie G West R

Comparison of the safety and efficacy of bilateral simultaneous total hip replacement (THR) and that of staged bilateral THR and unilateral THR was conducted using DerSimonian-Laird heterogeneity meta-analysis. A review of the English-language literature identified 23 citations eligible for inclusion. A total of 2063 bilateral simultaneous THR patients were identified. Meta-analysis of homogeneous data revealed no statistically significant differences in the rates of thromboembolic events (p = 0.268 and p = 0.365) and dislocation (p = 0.877) when comparing staged or unilateral with bilateral simultaneous THR procedures. A systematic analysis of heterogeneous data demonstrated that the mean length of hospital stay was shorter after bilateral simultaneous THR. Higher blood transfusion requirements were expected following bilateral simultaneous THR than staged or unilateral THR, and surgical time was not different between groups. This procedure was also found to be economically and functionally efficacious when performed by experienced surgeons in specialist centres


Bone & Joint Open
Vol. 4, Issue 6 | Pages 416 - 423
2 Jun 2023
Tung WS Donnelley C Eslam Pour A Tommasini S Wiznia D

Aims. Computer-assisted 3D preoperative planning software has the potential to improve postoperative stability in total hip arthroplasty (THA). Commonly, preoperative protocols simulate two functional positions (standing and relaxed sitting) but do not consider other common positions that may increase postoperative impingement and possible dislocation. This study investigates the feasibility of simulating commonly encountered positions, and positions with an increased risk of impingement, to lower postoperative impingement risk in a CT-based 3D model. Methods. A robotic arm-assisted arthroplasty planning platform was used to investigate 11 patient positions. Data from 43 primary THAs were used for simulation. Sacral slope was retrieved from patient preoperative imaging, while angles of hip flexion/extension, hip external/internal rotation, and hip abduction/adduction for tested positions were derived from literature or estimated with a biomechanical model. The hip was placed in the described positions, and if impingement was detected by the software, inspection of the impingement type was performed. Results. In flexion, an overall impingement rate of 2.3% was detected for flexed-seated, squatting, forward-bending, and criss-cross-sitting positions, and 4.7% for the ankle-over-knee position. In extension, most hips (60.5%) were found to impinge at or prior to 50° of external rotation (pivoting). Many of these impingement events were due to a prominent ischium. The mean maximum external rotation prior to impingement was 45.9° (15° to 80°) and 57.9° (20° to 90°) prior to prosthetic impingement. No impingement was found in standing, sitting, crossing ankles, seiza, and downward dog. Conclusion. This study demonstrated that positions of daily living tested in a CT-based 3D model show high rates of impingement. Simulating additional positions through 3D modelling is a low-cost method of potentially improving outcomes without compromising patient safety. By incorporating CT-based 3D modelling of positions of daily living into routine preoperative protocols for THA, there is the potential to lower the risk of postoperative impingement events. Cite this article: Bone Jt Open 2023;4(6):416–423


Bone & Joint Open
Vol. 4, Issue 5 | Pages 385 - 392
24 May 2023
Turgeon TR Hedden DR Bohm ER Burnell CD

Aims. Instability is a common cause of failure after total hip arthroplasty. A novel reverse total hip has been developed, with a femoral cup and acetabular ball, creating enhanced mechanical stability. The purpose of this study was to assess the implant fixation using radiostereometric analysis (RSA), and the clinical safety and efficacy of this novel design. Methods. Patients with end-stage osteoarthritis were enrolled in a prospective cohort at a single centre. The cohort consisted of 11 females and 11 males with mean age of 70.6 years (SD 3.5) and BMI of 31.0 kg/m. 2. (SD 5.7). Implant fixation was evaluated using RSA as well as Western Ontario and McMaster Universities Osteoarthritis Index, Harris Hip Score, Oxford Hip Score, Hip disability and Osteoarthritis Outcome Score, 38-item Short Form survey, and EuroQol five-dimension health questionnaire scores at two-year follow-up. At least one acetabular screw was used in all cases. RSA markers were inserted into the innominate bone and proximal femur with imaging at six weeks (baseline) and six, 12, and 24 months. Independent-samples t-tests were used to compare to published thresholds. Results. Mean acetabular subsidence from baseline to 24 months was 0.087 mm (SD 0.152), below the critical threshold of 0.2 mm (p = 0.005). Mean femoral subsidence from baseline to 24 months was -0.002 mm (SD 0.194), below the published reference of 0.5 mm (p < 0.001). There was significant improvement in patient-reported outcome measures at 24 months with good to excellent results. Conclusion. RSA analysis demonstrates excellent fixation with a predicted low risk of revision at ten years of this novel reverse total hip system. Clinical outcomes were consistent with safe and effective hip replacement prostheses. Cite this article: Bone Jt Open 2023;4(5):385–392


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 29 - 34
1 Jan 2023
Fransen BL Bengoa FJ Neufeld ME Sheridan GA Garbuz DS Howard LC

Aims. Several short- and mid-term studies have shown minimal liner wear of highly cross-linked polyethylene (HXLPE) in total hip arthroplasty (THA), but the safety of using thinner HXLPE liners to maximize femoral head size remains uncertain. The objective of this study was to analyze clinical survival and radiological wear rates of patients with HXLPE liners, a 36 mm femoral head, and a small acetabular component with a minimum of ten years’ follow-up. Methods. We retrospectively identified 55 patients who underwent primary THA performed at a single centre, using HXLPE liners with 36 mm cobalt-chrome heads in acetabular components with an outer diameter of 52 mm or smaller. Patient demographic details, implant details, death, and all-cause revisions were recorded. Cox regression and Kaplan-Meier survival was used to determine all-cause and liner-specific revision. Of these 55 patients, 22 had a minimum radiological follow-up of seven years and were assessed radiologically for linear and volumetric wear. Results. Overall survival rate for all-cause revision was 94.5% (95% confidence interval (CI) 81.7% to 97.2%) at a mean follow-up of 12.8 years (10.9 to 18.7). Three patients were revised, none for liner wear, fracture, or dissociation. A total of 22 patients were included in the radiological analysis (mean follow-up 9.9 years (7.5 to 13.7)). Mean linear liner wear was 0.085 mm (95% CI -0.086 to 0.257) and the volumetric wear rate was 11.097 mm. 3. /year (95% CI -6.5 to 28.7). Conclusion. Using HXLPE liners with 36 mm heads in 52 mm acetabular components or smaller is safe, with excellent survival and low rates of linear and volumetric wear at medium-term follow-up. Patients did not require revision surgery for liner complications such as fracture, dissociation, or wear. Our results suggest that the advantages of using larger heads outweigh the potential risks of using thin HXLPE liners. Cite this article: Bone Joint J 2023;105-B(1):29–34


Bone & Joint Open
Vol. 3, Issue 4 | Pages 340 - 347
22 Apr 2022
Winkler T Costa ML Ofir R Parolini O Geissler S Volk H Eder C

Aims. The aim of the HIPGEN consortium is to develop the first cell therapy product for hip fracture patients using PLacental-eXpanded (PLX-PAD) stromal cells. Methods. HIPGEN is a multicentre, multinational, randomized, double-blind, placebo-controlled trial. A total of 240 patients aged 60 to 90 years with low-energy femoral neck fractures (FNF) will be allocated to two arms and receive an intramuscular injection of either 150 × 10. 6. PLX-PAD cells or placebo into the medial gluteal muscle after direct lateral implantation of total or hemi hip arthroplasty. Patients will be followed for two years. The primary endpoint is the Short Physical Performance Battery (SPPB) at week 26. Secondary and exploratory endpoints include morphological parameters (lean body mass), functional parameters (abduction and handgrip strength, symmetry in gait, weightbearing), all-cause mortality rate and patient-reported outcome measures (Lower Limb Measure, EuroQol five-dimension questionnaire). Immunological biomarker and in vitro studies will be performed to analyze the PLX-PAD mechanism of action. A sample size of 240 subjects was calculated providing 88% power for the detection of a 1 SPPB point treatment effect for a two-sided test with an α level of 5%. Conclusion. The HIPGEN study assesses the efficacy, safety, and tolerability of intramuscular PLX-PAD administration for the treatment of muscle injury following arthroplasty for hip fracture. It is the first phase III study to investigate the effect of an allogeneic cell therapy on improved mobilization after hip fracture, an aspect which is in sore need of addressing for the improvement in standard of care treatment for patients with FNF. Cite this article: Bone Jt Open 2022;3(4):340–347


Bone & Joint Open
Vol. 4, Issue 11 | Pages 853 - 858
10 Nov 2023
Subbiah Ponniah H Logishetty K Edwards TC Singer GC

Aims. Metal-on-metal hip resurfacing (MoM-HR) has seen decreased usage due to safety and longevity concerns. Joint registries have highlighted the risks in females, smaller hips, and hip dysplasia. This study aimed to identify if reported risk factors are linked to revision in a long-term follow-up of MoM-HR performed by a non-designer surgeon. Methods. A retrospective review of consecutive MoM hip arthroplasties (MoM-HRAs) using Birmingham Hip Resurfacing was conducted. Data on procedure side, indication, implant sizes and orientation, highest blood cobalt and chromium ion concentrations, and all-cause revision were collected from local and UK National Joint Registry records. Results. A total of 243 hips (205 patients (163 male, 80 female; mean age at surgery 55.3 years (range 25.7 to 75.3)) with MoM-HRA performed between April 2003 and October 2020 were included. Mean follow-up was 11.2 years (range 0.3 to 17.8). Osteoarthritis was the most common indication (93.8%), and 13 hips (5.3%; 7M:6F) showed dysplasia (lateral centre-edge angle < 25°). Acetabular cups were implanted at a median of 45.4° abduction (interquartile range 41.9° - 48.3°) and stems neutral or valgus to the native neck-shaft angle. In all, 11 hips (4.5%; one male, ten females) in ten patients underwent revision surgery at a mean of 7.4 years (range 2.8 to 14.2), giving a cumulative survival rate of 94.8% (95% confidence interval (CI) 91.6% to 98.0%) at ten years, and 93.4% (95% CI 89.3% to 97.6%) at 17 years. For aseptic revision, male survivorship was 100% at 17 years, and 89.6% (95% CI 83.1% to 96.7%) at ten and 17 years for females. Increased metal ion levels were implicated in 50% of female revisions, with the remaining being revised for unexplained pain or avascular necrosis. Conclusion. The Birmingham MoM-HR showed 100% survivorship in males, exceeding the National Institute for Health and Care Excellence ‘5% at ten years’ threshold. Female sex and small component sizes are independent risk factors. Dysplasia alone is not a contraindication to resurfacing. Cite this article: Bone Jt Open 2023;4(11):853–858


Bone & Joint Open
Vol. 3, Issue 6 | Pages 485 - 494
13 Jun 2022
Jaubert M Le Baron M Jacquet C Couvreur A Fabre-Aubrespy M Flecher X Ollivier M Argenson J

Aims. Two-stage exchange revision total hip arthroplasty (THA) performed in case of periprosthetic joint infection (PJI) has been considered for many years as being the gold standard for the treatment of chronic infection. However, over the past decade, there have been concerns about its safety and its effectiveness. The purposes of our study were to investigate our practice, collecting the overall spacer complications, and then to analyze their risk factors. Methods. We retrospectively included 125 patients with chronic hip PJI who underwent a staged THA revision performed between January 2013 and December 2019. All spacer complications were systematically collected, and risk factors were analyzed. Statistical evaluations were performed using the Student's t-test, Mann-Whitney U test, and Fisher's exact test. Results. Our staged exchange practice shows poor results, which means a 42% mechanical spacer failure rate, and a 20% recurrent infection rate over the two years average follow-up period. Moreover, we found a high rate of spacer dislocation (23%) and a low rate of spacer fracture (8%) compared to the previous literature. Our findings stress that the majority of spacer complications and failures is reflecting a population with high comorbid burden, highlighted by the American Society of Anesthesiology grade, Charlson Comorbidity Index, and Lee score associations, as well as the cardiac, pulmonary, kidney, or hepatic chronic conditions. Conclusion. Our experience of a two-stage hip exchange revision noted important complication rates associated with high failure rates of polymethylmethacrylate spacers. These findings must be interpreted in the light of the patient’s comorbidity profiles, as the elective population for staged exchange has an increasing comorbid burden leading to poor results. In order to provide better results for this specific population, our conclusion suggests that comparative strategy studies are required to improve our therapeutic indication. Cite this article: Bone Jt Open 2022;3(6):485–494


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1197 - 1205
1 Jul 2021
Magill P Hill JC Bryce L Martin U Dorman A Hogg R Campbell C Gardner E McFarland M Bell J Benson G Beverland D

Aims. A typical pattern of blood loss associated with total hip arthroplasty (THA) is 200 ml intraoperatively and 1.3 l in the first 48 postoperative hours. Tranexamic acid (TXA) is most commonly given as a single preoperative dose only and is often withheld from patients with a history of thromboembolic disease as they are perceived to be “high-risk” with respect to postoperative venous thromboembolism (VTE). The TRanexamic ACid for 24 hours trial (TRAC-24) aimed to identify if an additional 24-hour postoperative TXA regime could further reduce blood loss beyond a once-only dose at the time of surgery, without excluding these high-risk patients. Methods. TRAC-24 was a prospective, phase IV, single centre, open label, parallel group, randomized controlled trial (RCT) involving patients undergoing primary unilateral elective THA. The primary outcome measure was the indirect calculated blood loss (IBL) at 48 hours. The patients were randomized into three groups. Group 1 received 1 g intravenous (IV) TXA at the time of surgery and an additional oral regime for 24 hours postoperatively, group 2 only received the intraoperative dose, and group 3 did not receive any TXA. Results. A total of 534 patients were randomized, with 233 in group 1, 235 in group 2, and 66 in group 3; 92 patients (17.2%) were considered high-risk. The mean IBL did not differ significantly between the two intervention groups (848.4 ml (SD 463.8) for group 1, and 843.7 ml (SD 478.7) for group 2; mean difference -4.7 ml (95% confidence interval -82.9 to 92.3); p = 0.916). No differences in mortality or incidence of VTE were observed between any group. Conclusion. The addition of oral TXA for 24 hours postoperatively does not reduce blood loss beyond that achieved with a single 1 g IV perioperative dose alone. There may be a clinically relevant difference in patients with a normal BMI, which warrants further investigation. Critically, there were no safety issues in patients with a history of thromboembolic, cardiovascular, or cerebrovascular disease. Cite this article: Bone Joint J 2021;103-B(7):1197–1205


Bone & Joint Open
Vol. 2, Issue 7 | Pages 535 - 539
15 Jul 2021
Zak SG Lygrisse K Tang A Meftah M Long WJ Schwarzkopf R

Aims. As our population ages, the number of octogenarians who will require a total hip arthroplasty (THA) rises. In a value-based system where operative outcomes are linked to hospital payments, it is necessary to assess the outcomes in this population. The purpose of this study was to compare outcomes of elective, primary THA in patients ≥ 80 years old to those aged < 80. Methods. A retrospective review of 10,251 consecutive THA cases from 2011 to 2019 was conducted. Patient-reported outcome (PRO) scores (Hip disability and Osteoarthritis Outcome Score (HOOS)), as well as demographic, readmission, and complication data, were collected. Results. On average, the younger cohort (YC, n = 10,251) was a mean 61.60 years old (SD 10.71), while the older cohort (OC, n = 609) was 84.25 years old (SD 3.02) (p < 0.001). The OC had greater surgical risk based on their higher mean American Society of Anesthesiologists (ASA) scores (2.74 (SD 0.63) vs 2.30 (SD 0.63); p < 0.001) and Charlson Comorbidity Index (CCI) scores (6.26 (SD 1.71) vs 3.87 (SD 1.98); p < 0.001). While the OC stayed in the hospital longer than the YC (mean 3.5 vs 2.5 days; p < 0.001), there were no differences in 90-day emergency visits (p = 0.083), myocardial infarctions (p = 0.993), periprosthetic joint infections (p = 0.214), dislocations (p = 0.993), or aseptic failure (p = 0.993). The YC was more likely to be readmitted within 90 days (3.88% vs 2.18%, Β = 0.57; p = 0.048). There were no observed differences in 12-week (p = 0.518) or one-year (p = 0.511) HOOS scores. Conclusion. Although patients ≥ 80 years old have a greater number of comorbidities than younger patients, they had equivalent perioperative complication rates and PRO scores. This study demonstrates the safety and success of elective THA in octogenarians. Cite this article: Bone Jt Open 2021;2(7):535–539


Bone & Joint Research
Vol. 10, Issue 6 | Pages 354 - 362
1 Jun 2021
Luo Y Zhao X Yang Z Yeersheng R Kang P

Aims. The purpose of this study was to examine the efficacy and safety of carbazochrome sodium sulfonate (CSS) combined with tranexamic acid (TXA) on blood loss and inflammatory responses after primary total hip arthroplasty (THA), and to investigate the influence of different administration methods of CSS on perioperative blood loss during THA. Methods. This study is a randomized controlled trial involving 200 patients undergoing primary unilateral THA. A total of 200 patients treated with intravenous TXA were randomly assigned to group A (combined intravenous and topical CSS), group B (topical CSS), group C (intravenous CSS), or group D (placebo). Results. Mean total blood loss (TBL) in groups A (605.0 ml (SD 235.9)), B (790.9 ml (SD 280.7)), and C (844.8 ml (SD 248.1)) were lower than in group D (1,064.9 ml (SD 318.3), p < 0.001). We also found that compared with group D, biomarker level of inflammation, transfusion rate, pain score, and hip range of motion at discharge in groups A, B, and C were significantly improved. There were no differences among the four groups in terms of intraoperative blood loss (IBL), intramuscular venous thrombosis (IMVT), and length of hospital stay (LOS). Conclusion. The combined application of CSS and TXA is more effective than TXA alone in reducing perioperative blood loss and transfusion rates, inflammatory response, and postoperative hip pain, results in better early hip flexion following THA, and did not increase the associated venous thromboembolism (VTE) events. Intravenous combined with topical injection of CSS was superior to intravenous or topical injection of CSS alone in reducing perioperative blood loss. Cite this article: Bone Joint Res 2021;10(6):354–362


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1192 - 1198
1 Oct 2019
Sköldenberg OG Rysinska AD Chammout G Salemyr M Mukka SS Bodén H Eisler T

Aims. Radiostereometric analysis (RSA) studies of vitamin E-doped, highly crosslinked polyethylene (VEPE) liners show low head penetration rates in cementless acetabular components. There is, however, currently no data on cemented VEPE acetabular components in total hip arthroplasty (THA). The aim of this study was to evaluate the safety of a new cemented VEPE component, compared with a conventional polyethylene (PE) component regarding migration, head penetration, and clinical results. Patients and Methods. We enrolled 42 patients (21 male, 21 female) with osteoarthritis and a mean age of 67 years (. sd. 5), in a double-blinded, noninferiority, randomized controlled trial. The subjects were randomized in a 1:1 ratio to receive a reverse hybrid THA with a cemented component of either argon-gas gamma-sterilized PE component (controls) or VEPE, with identical geometry. The primary endpoint was proximal implant migration of the component at two years postoperatively measured with RSA. Secondary endpoints included total migration of the component, penetration of the femoral head into the component, and patient-reported outcome measurements. Results. In total, 19 control implants and 18 implants in the VEPE group were analyzed for the primary endpoint. We found a continuous proximal migration of the component in the VEPE group that was significantly higher with a difference at two years of a mean 0.21 mm (95% confidence interval (CI) 0.05 to 0.37; p = 0.013). The total migration was also significantly higher in the VEPE group, but femoral head penetration was lower. We found no difference in clinical outcomes between the groups. Conclusion. At two years, this cemented VEPE component, although having a low head penetration and excellent clinical results, failed to meet noninferiority compared with the conventional implant by a proximal migration above the proposed safety threshold of RSA. The early proximal migration pattern of the VEPE component is a reason for continued monitoring, although a specific threshold for proximal migration and risk for later failure cannot be defined and needs further study. Cite this article: Bone Joint J 2019;101-B:1192–1198


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 71 - 77
1 Jul 2020
Gonzalez Della Valle A Shanaghan KA Nguyen J Liu J Memtsoudis S Sharrock NE Salvati EA

Aims. We studied the safety and efficacy of multimodal thromboprophylaxis in patients with a history of venous thromboembolism (VTE) who undergo total hip arthroplasty (THA) within the first 120 postoperative days, and the mortality during the first year. Multimodal prophylaxis includes discontinuation of procoagulant medications, VTE risk stratification, regional anaesthesia, an intravenous bolus of unfractionated heparin prior to femoral preparation, rapid mobilization, the use of pneumatic compression devices, and chemoprophylaxis tailored to the patient’s risk of VTE. Methods. Between 2004 to 2018, 257 patients with a proven history of VTE underwent 277 primary elective THA procedures by two surgeons at a single institution. The patients had a history of deep vein thrombosis (DVT) (186, 67%), pulmonary embolism (PE) (43, 15.5%), or both (48, 17.5%). Chemoprophylaxis included aspirin (38 patients), anticoagulation (215 patients), or a combination of aspirin and anticoagulation (24 patients). A total of 50 patients (18%) had a vena cava filter in situ at the time of surgery. Patients were followed for 120 days to record complications, and for one year to record mortality. Results. Postoperative VTE was diagnosed in seven patients (2.5%): DVT in five, and PE with and without DVT in one patient each. After hospitalization, three patients required readmiss-ion for evacuation of a haematoma, one for wound drainage, and one for monitoring of an elevated international normalized ratio (INR). Seven patients died (2.5%). One patient died five months postoperatively of a PE during open thrombectomy. She had discontinued anticoagulation. One patient died of a haemorrhagic stroke while receiving Coumadin. PE or bleeding was not suspected in the remaining five fatalities. Conclusion. Multimodal prophylaxis is safe and effective in patients with a history of VTE. Postoperative anticoagulation should be prudent as very few patients developed VTE (2.5%) or died of suspected or confirmed PE. Mortality during the first year was mostly unrelated to either VTE or bleeding. Cite this article: Bone Joint J 2020;102-B(7 Supple B):71–77


Aims. Surgical treatment of hip fracture is challenging; the bone is porotic and fixation failure can be catastrophic. Novel implants are available which may yield superior clinical outcomes. This study compared the clinical effectiveness of the novel X-Bolt Hip System (XHS) with the sliding hip screw (SHS) for the treatment of fragility hip fractures. Methods. We conducted a multicentre, superiority, randomized controlled trial. Patients aged 60 years and older with a trochanteric hip fracture were recruited in ten acute UK NHS hospitals. Participants were randomly allocated to fixation of their fracture with XHS or SHS. A total of 1,128 participants were randomized with 564 participants allocated to each group. Participants and outcome assessors were blind to treatment allocation. The primary outcome was the EuroQol five-dimension five-level health status (EQ-5D-5L) utility at four months. The minimum clinically important difference in utility was pre-specified at 0.075. Secondary outcomes were EQ-5D-5L utility at 12 months, mortality, residential status, mobility, revision surgery, and radiological measures. Results. Overall, 437 and 443 participants were analyzed in the primary intention-to-treat analysis in XHS and SHS treatment groups respectively. There was a mean difference of 0.029 in adjusted utility index in favour of XHS with no evidence of a difference between treatment groups (95% confidence interval -0.013 to 0.070; p = 0.175). There was no evidence of any differences between treatment groups in any of the secondary outcomes. The pattern and overall risk of adverse events associated with both treatments was similar. Conclusion. Any difference in four-month health-related quality of life between the XHS and SHS is small and not clinically important. There was no evidence of a difference in the safety profile of the two treatments; both were associated with lower risks of revision surgery than previously reported. Cite this article: Bone Joint J 2021;103-B(2):256–263


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 699 - 708
1 Jun 2020
Nieuwenhuijse MJ Vehmeijer SBW Mathijsen NMC Keizer SB

Aims. Short, bone-conserving femoral components are increasingly used in total hip arthroplasty (THA). They are expected to allow tissue-conserving implantation and to render future revision surgery more straightforward but the long-term data on such components is limited. One such component is the global tissue-sparing (GTS) stem. Following the model for stepwise introduction of new orthopaedic implants, we evaluated early implant fixation and clinical outcome of this novel short-stem THA and compared it to that of a component with established good long-term clinical outcome. Methods. In total, 50 consecutive patients ≤ 70 years old with end-stage symptomatic osteo-arthritis were randomized to receive THA with the GTS stem or the conventional Taperloc stem using the anterior supine intermuscular approach by two experienced hip surgeons in two hospitals in the Netherlands. Primary outcome was implant migration. Patients were followed using routine clinical examination, patient reported outcome using Harris Hip Score (HHS), Hip Disability And Osteoarthritis Outcome Score (HOOS), EuroQol five-dimension questionnaire (EQ5D), and Roentgen Stereophotogrammetric Analysis (RSA) at three, six, 12, and 24 months. This study evaluated the two-year follow-up results. Results. In addition to the initial migration pattern of distal migration (subsidence, Y-translation) and retroversion (Y-rotation) also exhibited by the Taperloc stem, the GTS stem showed an initial migration pattern of varization (X-translation combined with Z-rotation) and posterior translation (Z-translation). However, all components stabilized aside from one Taperloc stem which became loose secondary to malposition and was later revised. Clinical outcomes and complications were not statistically significantly different with the numbers available. Conclusion. A substantially different and more extensive initial migration pattern was seen for the GTS stem compared to the Taperloc stem. Although implant stabilization was achieved, excellent long-term survival similar to that of the Taperloc stem should not be inferred. Especially in the absence of clinically proven relevant improvement, widespread usage should be postponed until long-term safety has been established. Cite this article: Bone Joint J 2020;102-B(6):699–708


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 74 - 76
1 Nov 2013
Kamath AF McAuliffe CL Gutsche JT Kosseim LM Hume EL Baldwin KD Kornfield Z Israelite CL

Patient safety is a critical issue in elective total joint replacement surgery. Identifying risk factors that might predict complications and intensive care unit (ICU) admission proves instrumental in reducing morbidity and mortality. The institution’s experience with risk stratification and pre-operative ICU triage has resulted in a reduction in unplanned ICU admissions and post-operative complications after total hip replacement. The application of the prediction tools to total knee replacement has proven less robust so far. This work also reviews areas for future research in patient safety and cost containment. . Cite this article: Bone Joint J 2013;95-B, Supple A:74–6


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1297 - 1302
3 Oct 2020
Kurosaka K Tsukada S Ogawa H Nishino M Nakayama T Yoshiya S Hirasawa N

Aims. Although periarticular injection plays an important role in multimodal pain management following total hip arthroplasty (THA), there is no consensus on the optimal composition of the injection. In particular, it is not clear whether the addition of a corticosteroid improves the pain relief achieved nor whether it is associated with more complications than are observed without corticosteroid. The aim of this study was to quantify the safety and effectiveness of cortocosteroid use in periarticular injection during THA. Methods. We conducted a prospective, two-arm, parallel-group, randomized controlled trial involving patients scheduled for unilateral THA. A total of 187 patients were randomly assigned to receive periarticular injection containing either a corticosteroid (CS group) or without corticosteroid (no-CS group). Other perioperative interventions were identical for all patients. The primary outcome was postoperative pain at rest during the initial 24 hours after surgery. Pain score was recorded every three hours until 24 hours using a 100 mm visual analogue scale (VAS). The primary outcome was assessed based on the area under the curve (AUC). Results. The CS group had a significantly lower AUC postoperatively at 0 to 24 hours compared to the no-CS group (AUC of VAS score at rest 550 ± 362 vs 392 ± 320, respectively; mean difference 158 mm; 95% confidence interval (CI) 58 to 257; p = 0.0021). In point-by-point evaluation, the CS group had significantly lower VAS scores at 12, 15, 18, 21, 24, and 48 hours. There were no significant differences in complication rates, including surgical site infection, between the two groups. Conclusion. The addition of corticosteroid to periarticular injections reduces postoperative pain without increasing complication rate following THA. Cite this article: Bone Joint J 2020;102-B(10):1297–1302


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 151 - 157
1 Feb 2024
Dreyer L Bader C Flörkemeier T Wagner M

Aims

The risk of mechanical failure of modular revision hip stems is frequently mentioned in the literature, but little is currently known about the actual clinical failure rates of this type of prosthesis. The current retrospective long-term analysis examines the distal and modular failure patterns of the Prevision hip stem from 18 years of clinical use. A design improvement of the modular taper was introduced in 2008, and the data could also be used to compare the original and the current design of the modular connection.

Methods

We performed an analysis of the Prevision modular hip stem using the manufacturer’s vigilance database and investigated different mechanical failure patterns of the hip stem from January 2004 to December 2022.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 324 - 335
1 Apr 2024
Fontalis A Kayani B Plastow R Giebaly DE Tahmassebi J Haddad IC Chambers A Mancino F Konan S Haddad FS

Aims

Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA.

Methods

This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 459 - 466
1 Apr 2013
Fisher WD Agnelli G George DJ Kakkar AK Lassen MR Mismetti P Mouret P Turpie AGG

There is currently limited information available on the benefits and risks of extended thromboprophylaxis after hip fracture surgery. SAVE-HIP3 was a randomised, double-blind study conducted to evaluate the efficacy and safety of extended thromboprophylaxis with the ultra-low molecular-weight heparin semuloparin compared with placebo in patients undergoing hip fracture surgery. After a seven- to ten-day open-label run-in phase with semuloparin (20 mg once daily subcutaneously, initiated post-operatively), patients were randomised to once-daily semuloparin (20 mg subcutaneously) or placebo for 19 to 23 additional days. The primary efficacy endpoint was a composite of any venous thromboembolism (VTE; any deep-vein thrombosis and non-fatal pulmonary embolism) or all-cause death until day 24 of the double-blind period. Safety parameters included major and clinically relevant non-major bleeding, laboratory data, and treatment-emergent adverse events (TEAEs). Extended thromboprophylaxis with semuloparin demonstrated a relative risk reduction of 79% in the rate of any VTE or all-cause death compared with placebo (3.9% vs 18.6%, respectively; odds ratio 0.18 (95% confidence interval 0.07 to 0.45), p < 0.001). Two patients in the semuloparin group and none in the placebo group experienced clinically relevant bleeding. TEAE rates were similar in both groups. In conclusion, the SAVE-HIP3 study results demonstrate that patients undergoing hip fracture surgery benefit from extended thromboprophylaxis. Cite this article: Bone Joint J 2013;95-B:459–66


Bone & Joint Open
Vol. 5, Issue 7 | Pages 560 - 564
7 Jul 2024
Meißner N Strahl A Rolvien T Halder AM Schrednitzki D

Aims

Transfusion after primary total hip arthroplasty (THA) has become rare, and identification of causative factors allows preventive measures. The aim of this study was to determine patient-specific factors that increase the risk of needing a blood transfusion.

Methods

All patients who underwent elective THA were analyzed retrospectively in this single-centre study from 2020 to 2021. A total of 2,892 patients were included. Transfusion-related parameters were evaluated. A multiple logistic regression was performed to determine whether age, BMI, American Society of Anesthesiologists (ASA) grade, sex, or preoperative haemoglobin (Hb) could predict the need for transfusion within the examined patient population.


Bone & Joint Open
Vol. 4, Issue 3 | Pages 198 - 204
16 Mar 2023
Ramsay N Close JCT Harris IA Harvey LA

Aims

Cementing in arthroplasty for hip fracture is associated with improved postoperative function, but may have an increased risk of early mortality compared to uncemented fixation. Quantifying this mortality risk is important in providing safe patient care. This study investigated the association between cement use in arthroplasty and mortality at 30 days and one year in patients aged 50 years and over with hip fracture.

Methods

This retrospective cohort study used linked data from the Australian Hip Fracture Registry and the National Death Index. Descriptive analysis and Kaplan-Meier survival curves tested the unadjusted association of mortality between cemented and uncemented procedures. Multilevel logistic regression, adjusted for covariates, tested the association between cement use and 30-day mortality following arthroplasty. Given the known institutional variation in preference for cemented fixation, an instrumental variable analysis was also performed to minimize the effect of unknown confounders. Adjusted Cox modelling analyzed the association between cement use and mortality at 30 days and one year following surgery.


Bone & Joint Open
Vol. 5, Issue 10 | Pages 825 - 831
3 Oct 2024
Afghanyar Y Afghanyar B Loweg L Drees P Gercek E Dargel J Rehbein P Kutzner KP

Aims

Limited implant survival due to aseptic cup loosening is most commonly responsible for revision total hip arthroplasty (THA). Advances in implant designs and materials have been crucial in addressing those challenges. Vitamin E-infused highly cross-linked polyethylene (VEPE) promises strong wear resistance, high oxidative stability, and superior mechanical strength. Although VEPE monoblock cups have shown good mid-term performance and excellent wear patterns, long-term results remain unclear. This study evaluated migration and wear patterns and clinical and radiological outcomes at a minimum of ten years’ follow-up.

Methods

This prospective observational study investigated 101 cases of primary THA over a mean duration of 129 months (120 to 149). At last follow-up, 57 cases with complete clinical and radiological outcomes were evaluated. In all cases, the acetabular component comprised an uncemented titanium particle-coated VEPE monoblock cup. Patients were assessed clinically and radiologically using the Harris Hip Score, visual analogue scale (pain and satisfaction), and an anteroposterior radiograph. Cup migration and polyethylene wear were measured using Einzel-Bild-Röntgen-Analyze software. All complications and associated treatments were documented until final follow-up.


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 735 - 742
1 Jul 2023
Andronic O Germann C Jud L Zingg PO

Aims

This study reports mid-term outcomes after periacetabular osteotomy (PAO) exclusively in a borderline hip dysplasia (BHD) population to provide a contrast to published outcomes for arthroscopic surgery of the hip in BHD.

Methods

We identified 42 hips in 40 patients treated between January 2009 and January 2016 with BHD defined as a lateral centre-edge angle (LCEA) of ≥ 18° but < 25°. A minimum five-year follow-up was available. Patient-reported outcomes (PROMs) including Tegner score, subjective hip value (SHV), modified Harris Hip Score (mHHS), and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) were assessed. The following morphological parameters were evaluated: LCEA, acetabular index (AI), α angle, Tönnis staging, acetabular retroversion, femoral version, femoroepiphyseal acetabular roof index (FEAR), iliocapsularis to rectus femoris ratio (IC/RF), and labral and ligamentum teres (LT) pathology.


Bone & Joint Open
Vol. 5, Issue 8 | Pages 671 - 680
14 Aug 2024
Fontalis A Zhao B Putzeys P Mancino F Zhang S Vanspauwen T Glod F Plastow R Mazomenos E Haddad FS

Aims

Precise implant positioning, tailored to individual spinopelvic biomechanics and phenotype, is paramount for stability in total hip arthroplasty (THA). Despite a few studies on instability prediction, there is a notable gap in research utilizing artificial intelligence (AI). The objective of our pilot study was to evaluate the feasibility of developing an AI algorithm tailored to individual spinopelvic mechanics and patient phenotype for predicting impingement.

Methods

This international, multicentre prospective cohort study across two centres encompassed 157 adults undergoing primary robotic arm-assisted THA. Impingement during specific flexion and extension stances was identified using the virtual range of motion (ROM) tool of the robotic software. The primary AI model, the Light Gradient-Boosting Machine (LGBM), used tabular data to predict impingement presence, direction (flexion or extension), and type. A secondary model integrating tabular data with plain anteroposterior pelvis radiographs was evaluated to assess for any potential enhancement in prediction accuracy.


Bone & Joint Open
Vol. 3, Issue 12 | Pages 991 - 997
23 Dec 2022
McPherson EJ Stavrakis AI Chowdhry M Curtin NL Dipane MV Crawford BM

Aims

Large acetabular bone defects encountered in revision total hip arthroplasty (THA) are challenging to restore. Metal constructs for structural support are combined with bone graft materials for restoration. Autograft is restricted due to limited volume, and allogenic grafts have downsides including cost, availability, and operative processing. Bone graft substitutes (BGS) are an attractive alternative if they can demonstrate positive remodelling. One potential product is a biphasic injectable mixture (Cerament) that combines a fast-resorbing material (calcium sulphate) with the highly osteoconductive material hydroxyapatite. This study reviews the application of this biomaterial in large acetabular defects.

Methods

We performed a retrospective review at a single institution of patients undergoing revision THA by a single surgeon. We identified 49 consecutive patients with large acetabular defects where the biphasic BGS was applied, with no other products added to the BGS. After placement of metallic acetabular implants, the BGS was injected into the remaining bone defects surrounding the new implants. Patients were followed and monitored for functional outcome scores, implant fixation, radiological graft site remodelling, and revision failures.


Bone & Joint Open
Vol. 4, Issue 5 | Pages 306 - 314
3 May 2023
Rilby K Mohaddes M Kärrholm J

Aims

Although the Fitmore Hip Stem has been on the market for almost 15 years, it is still not well documented in randomized controlled trials. This study compares the Fitmore stem with the CementLeSs (CLS) in several different clinical and radiological aspects. The hypothesis is that there will be no difference in outcome between stems.

Methods

In total, 44 patients with bilateral hip osteoarthritis were recruited from the outpatient clinic at a single tertiary orthopaedic centre. The patients were operated with bilateral one-stage total hip arthroplasty. The most painful hip was randomized to either Fitmore or CLS femoral component; the second hip was operated with the femoral component not used on the first side. Patients were evaluated at three and six months and at one, two, and five years postoperatively with patient-reported outcome measures, radiostereometric analysis, dual-energy X-ray absorptiometry, and conventional radiography. A total of 39 patients attended the follow-up visit at two years (primary outcome) and 35 patients at five years. The primary outcome was which hip the patient considered to have the best function at two years.


Bone & Joint Open
Vol. 4, Issue 3 | Pages 168 - 181
14 Mar 2023
Dijkstra H Oosterhoff JHF van de Kuit A IJpma FFA Schwab JH Poolman RW Sprague S Bzovsky S Bhandari M Swiontkowski M Schemitsch EH Doornberg JN Hendrickx LAM

Aims

To develop prediction models using machine-learning (ML) algorithms for 90-day and one-year mortality prediction in femoral neck fracture (FNF) patients aged 50 years or older based on the Hip fracture Evaluation with Alternatives of Total Hip arthroplasty versus Hemiarthroplasty (HEALTH) and Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trials.

Methods

This study included 2,388 patients from the HEALTH and FAITH trials, with 90-day and one-year mortality proportions of 3.0% (71/2,388) and 6.4% (153/2,388), respectively. The mean age was 75.9 years (SD 10.8) and 65.9% of patients (1,574/2,388) were female. The algorithms included patient and injury characteristics. Six algorithms were developed, internally validated and evaluated across discrimination (c-statistic; discriminative ability between those with risk of mortality and those without), calibration (observed outcome compared to the predicted probability), and the Brier score (composite of discrimination and calibration).


Bone & Joint Open
Vol. 3, Issue 11 | Pages 867 - 876
10 Nov 2022
Winther SS Petersen M Yilmaz M Kaltoft NS Stürup J Winther NS

Aims

Pelvic discontinuity is a rare but increasingly common complication of total hip arthroplasty (THA). This single-centre study evaluated the performance of custom-made triflange acetabular components in acetabular reconstruction with pelvic discontinuity by determining: 1) revision and overall implant survival rates; 2) discontinuity healing rate; and 3) Harris Hip Score (HHS).

Methods

Retrospectively collected data of 38 patients (39 hips) with pelvic discontinuity treated with revision THA using a custom-made triflange acetabular component were analyzed. Minimum follow-up was two years (mean 5.1 years (2 to 11)).


Bone & Joint Open
Vol. 3, Issue 10 | Pages 804 - 814
13 Oct 2022
Grammatopoulos G Laboudie P Fischman D Ojaghi R Finless A Beaulé PE

Aims

The primary aim of this study was to determine the ten-year outcome following surgical treatment for femoroacetabular impingement (FAI). We assessed whether the evolution of practice from open to arthroscopic techniques influenced outcomes and tested whether any patient, radiological, or surgical factors were associated with outcome.

Methods

Prospectively collected data of a consecutive single-surgeon cohort, operated for FAI between January 2005 and January 2015, were retrospectively studied. The cohort comprised 393 hips (365 patients; 71% male (n = 278)), with a mean age of 34.5 years (SD 10.0). Over the study period, techniques evolved from open surgical dislocation (n = 94) to a combined arthroscopy-Hueter technique (HA + Hueter; n = 61) to a pure arthroscopic technique (HA; n = 238). Outcome measures of interest included modes of failures, complications, reoperation, and patient-reported outcome measures (PROMs). Demographic, radiological, and surgical factors were tested for possible association with outcome.


Bone & Joint Research
Vol. 6, Issue 8 | Pages 472 - 480
1 Aug 2017
Oduwole KO de SA D Kay J Findakli F Duong A Simunovic N Yen Y Ayeni OR

Objectives. The purpose of this study was to evaluate the existing literature from 2005 to 2016 reporting on the efficacy of surgical management of patients with femoroacetabular impingement (FAI) secondary to slipped capital femoral epiphysis (SCFE). Methods. The electronic databases MEDLINE, EMBASE, and PubMed were searched and screened in duplicate. Data such as patient demographics, surgical technique, surgical outcomes and complications were retrieved from eligible studies. Results. Fifteen eligible level IV studies were included in this review comprising 261 patients (266 hips). Treatment groups included arthroscopic osteochondroplasty, surgical hip dislocation, and traditional open osteotomy. The mean alpha angle corrections were 32.14° (standard deviation (. sd). 7.02°), 41.45° (. sd. 10.5°) and 6.0° (. sd. 5.21°), for arthroscopy, surgical hip dislocation, and open osteotomy groups, respectively (p < 0.05). Each group demonstrated satisfactory clinical outcomes across their respective scoring systems. Major complication rates were 1.6%, 10.7%, and 6.7%, for arthroscopy, surgical dislocation and osteotomy treatments, respectively. Conclusion. In the context of SCFE-related FAI, surgical hip dislocation demonstrated improved correction of the alpha angle, albeit at higher complication and revision rates than both arthroscopic and open osteotomy treatments. Further investigation, including high-quality trials with standardised radiological and clinical outcome measures for young patients, is warranted to clarify treatment approaches and safety. Cite this article: K. O. Oduwole, D. de Sa, J. Kay, F. Findakli, A. Duong, N. Simunovic, Y. Yi-Meng, O. R. Ayeni. Surgical treatment of femoroacetabular impingement following slipped capital femoral epiphysis: A systematic review. Bone Joint Res 2017;6:472–480. DOI: 10.1302/2046-3758.68.BJR-2017-0018.R1


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 867 - 874
1 Jul 2022
Ji B Li G Zhang X Xu B Wang Y Chen Y Cao L

Aims

Periprosthetic joint infections (PJIs) with prior multiple failed surgery for reinfection represent a huge challenge for surgeons because of poor vascular supply and biofilm formation. This study aims to determine the results of single-stage revision using intra-articular antibiotic infusion in treating this condition.

Methods

A retrospective analysis included 78 PJI patients (29 hips; 49 knees) who had undergone multiple prior surgical interventions. Our cohort was treated with single-stage revision using a supplementary intra-articular antibiotic infusion. Of these 78 patients, 59 had undergone more than two prior failed debridement and implant retentions, 12 patients had a failed arthroplasty resection, three hips had previously undergone failed two-stage revision, and four had a failed one-stage revision before their single-stage revision. Previous failure was defined as infection recurrence requiring surgical intervention. Besides intravenous pathogen-sensitive agents, an intra-articular infusion of vancomycin, imipenem, or voriconazole was performed postoperatively. The antibiotic solution was soaked into the joint for 24 hours for a mean of 16 days (12 to 21), then extracted before next injection. Recurrence of infection and clinical outcomes were evaluated.


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 303 - 309
1 Mar 2017
Beaulé PE Bleeker H Singh A Dobransky J

Aims. Joint-preserving surgery of the hip (JPSH) has evolved considerably and now includes a number of procedures, including arthroscopy, surgical dislocation, and redirectional osteotomies of the femur and acetabulum. There are a number of different factors which lead to failure of JPSH. Consequently, it is of interest to assess the various modes of failure in order to continue to identify best practice and the indications for these procedures. . Patients and Methods. Using a retrospective observational study design, we reviewed 1013 patients who had undergone JPSH by a single surgeon between 2005 and 2015. There were 509 men and 504 women with a mean age of 39 years (16 to 78). Of the 1013 operations, 783 were arthroscopies, 122 surgical dislocations, and 108 peri-acetabular osteotomies (PAO). We analysed the overall failure rates and modes of failure. Re-operations were categorised into four groups: Mode 1 was arthritis progression or organ failure leading to total hip arthroplasty (THA); Mode 2 was an Incorrect diagnosis/procedure; Mode 3 resulted from malcorrection of femur (type A), acetabulum (type B), or labrum (type C) and Mode 4 resulted from an unintended consequence of the initial surgical intervention. Results. At a mean follow-up of 2.5 years, there had been 104 re-operations (10.2%) with a mean patient age of 35.5 years (17 to 64). There were 64 Mode 1 failures (6.3%) at a mean of 3.2 years following JPSH with a mean patient age of 46.8 years (18 to 64). There were 17 Mode 2 failures (1.7%) at a mean of 2.2 years post-JPSH with a mean patient age of 28.9 years (17 to 42) (2% scopes; 1% surgical dislocations). There were 19 Mode 3 failures (1.9%) at a mean of 2.0 years post-JPSH, with a mean patient age of 29.9 years (18 to 51) (2% scopes; 2% surgical dislocations; 5% PAO). There were 4 Mode 4 failures (0.4%) at a mean of 1.8 years post-JPSH with a mean patient age of 31.5 years (15 to 43). Using the modified Dindo-Clavien classification system, the overall complication rate among JPSHs was 4.2%. Conclusion. While defining the overall re-operation and complication rates, it is important to define the safety and effectiveness of JPSH. Standardisation of the modes of failure may help identify the best practice. Application of these modes to large clinical series, such as registries, will assist in further establishing how to improve the efficacy of JPSH. Cite this article: Bone Joint J 2017;99-B:303–9


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 747 - 753
1 Jun 2016
Tengberg PT Foss NB Palm H Kallemose T Troelsen A

Aims. We chose unstable extra-capsular hip fractures as our study group because these types of fractures suffer the largest blood loss. We hypothesised that tranexamic acid (TXA) would reduce total blood loss (TBL) in extra-capsular fractures of the hip. . Patients and Methods. A single-centre placebo-controlled double-blinded randomised clinical trial was performed to test the hypothesis on patients undergoing surgery for extra-capsular hip fractures. For reasons outside the control of the investigators, the trial was stopped before reaching the 120 included patients as planned in the protocol. . Results. In all 72 patients (51 women, 21 men; 33 patients in the TXA group, 39 in the placebo group) were included in the final analysis, with a significant mean reduction of 570.8 ml (p = 0.029) in TBL from 2100.4 ml (standard deviation (. sd). = 1152.6) in the placebo group to 1529.6 ml (. sd. = 1012.7) in the TXA group. . The 90-day mortality was 27.2% (n = 9) in the TXA group and 10.2% (n = 4) in the placebo group (p = 0.07). We were not able to ascertain a reliable cause of death in these patients. . Discussion. TXA significantly reduced TBL in extra-capsular hip fractures, but concerns regarding its safety in this patient group must be investigated further before the use of TXA can be recommended. Take home message: We present a randomised clinical trial that is unique in the literature. We evaluate the effect of TXA in very homogenous population - extra-capsular fractures operated with short intramedullary nails. Cite this article: Bone Joint J 2016;98-B:747–53


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 16 - 21
1 Jan 2017
Aprato A Leunig M Massé A Slongo T Ganz R

Aims. Several studies have reported the safety and efficacy of subcapital re-alignment for patients with slipped capital femoral epiphysis (SCFE) using surgical dislocation of the hip and an extended retinacular flap. Instability of the hip and dislocation as a consequence of this surgery has only recently gained attention. We discuss this problem with some illustrative cases. Materials and Methods. We explored the literature on the possible pathophysiological causes and surgical steps associated with the risk of post-operative instability and articular damage. In addition, we describe supplementary steps that could be used to avoid these problems. Results. The causes of instability may be divided into three main groups: the first includes causes directly related to SCFE (acetabular labral damage, severe abrasion of the acetabular cartilage, flattening of the acetabular roof and a bell-shaped deformity of the epiphysis); the second, causes not related to the SCFE (acetabular orientation and poor quality of the soft tissues); the third, causes directly related to the surgery (capsulotomy, division of the ligamentum teres, shortening of the femoral neck, pelvi-trochanteric impingement, previous proximal femoral osteotomy and post-operative positioning of the leg). Conclusion. We present examples drawn from our clinical practice, as well as possible ways of reducing the risks of these complications, and of correcting them if they happen. Cite this article: Bone Joint J 2017;99-B:16–21


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 359 - 367
1 Mar 2022
Deere K Matharu GS Ben-Shlomo Y Wilkinson JM Blom AW Sayers A Whitehouse MR

Aims

A recent report from France suggested an association between the use of cobalt-chrome (CoCr) femoral heads in total hip arthroplasties (THAs) and an increased risk of dilated cardiomyopathy and heart failure. CoCr is a commonly used material in orthopaedic implants. If the reported association is causal, the consequences would be significant given the millions of joint arthroplasties and other orthopaedic procedures in which CoCr is used annually. We examined whether CoCr-containing THAs were associated with an increased risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders in a large national database.

Methods

Data from the National Joint Registry was linked to NHS English hospital inpatient episodes for 374,359 primary THAs with up to 14.5 years' follow-up. We excluded any patients with bilateral THAs, knee arthroplasties, indications other than osteoarthritis, aged under 55 years, and diagnosis of one or more outcome of interest before THA. Implants were grouped as either containing CoCr or not containing CoCr. The association between implant construct and the risk of all-cause mortality and incident heart failure, cancer, and neurodegenerative disorders was examined.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1036 - 1042
1 Aug 2016
Amanatullah DF Masini MA Roger DJ Pagnano MW

Aims. We wished to quantify the extent of soft-tissue damage sustained during minimally invasive total hip arthroplasty through the direct anterior (DA) and direct superior (DS) approaches. Materials and Methods. In eight cadavers, the DA approach was performed on one side, and the DS approach on the other, a single brand of uncemented hip prosthesis was implanted by two surgeons, considered expert in their surgical approaches. Subsequent reflection of the gluteus maximus allowed the extent of muscle and tendon damage to be measured and the percentage damage to each anatomical structure to be calculated. Results. The DA approach caused substantially greater damage to the gluteus minimus muscle and tendon when compared with the DS approach (t-test, p = 0.049 and 0.003, respectively). The tensor fascia lata and rectus femoris muscles were damaged only in the DA approach. There was no difference in the amount of damage to the gluteus medius muscle and tendon, piriformis tendon, obturator internus tendon, obturator externus tendon or quadratus femoris muscle between approaches. The posterior soft-tissue releases of the DA approach damaged the gluteus minimus muscle and tendon, piriformis tendon and obturator internus tendon. Conclusion. The DS approach caused less soft-tissue damage than the DA approach. However the clinical relevance is unknown. Further clinical outcome studies, radiographic evaluation of component position, gait analyses and serum biomarker levels are necessary to evaluate and corroborate the safety and efficacy of the DS approach. Cite this article: Bone Joint J 2016;98-B1036–42


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 341 - 351
1 Mar 2022
Fowler TJ Aquilina AL Reed MR Blom AW Sayers A Whitehouse MR

Aims

Total hip arthroplasties (THAs) are performed by surgeons at various stages in training with varying levels of supervision, but we do not know if this is safe practice with comparable outcomes to consultant-performed THA. Our aim was to examine the association between surgeon grade, the senior supervision of trainees, and the risk of revision following THA.

Methods

We performed an observational study using National Joint Registry (NJR) data. We included adult patients who underwent primary THA for osteoarthritis, recorded in the NJR between 2003 and 2016. Exposures were operating surgeon grade (consultant or trainee) and whether or not trainees were directly supervised by a scrubbed consultant. Outcomes were all-cause revision and the indication for revision up to ten years. We used methods of survival analysis, adjusted for patient, operation, and healthcare setting factors.


Bone & Joint Open
Vol. 3, Issue 1 | Pages 4 - 11
3 Jan 2022
Argyrou C Tzefronis D Sarantis M Kateros K Poultsides L Macheras GA

Aims

There is evidence that morbidly obese patients have more intra- and postoperative complications and poorer outcomes when undergoing total hip arthroplasty (THA) with the direct anterior approach (DAA). The aim of this study was to determine the efficacy of DAA for THA, and compare the complications and outcomes of morbidly obese patients with nonobese patients.

Methods

Morbidly obese patients (n = 86), with BMI ≥ 40 kg/m2 who underwent DAA THA at our institution between September 2010 and December 2017, were matched to 172 patients with BMI < 30 kg/m2. Data regarding demographics, set-up and operating time, blood loss, radiological assessment, Harris Hip Score (HHS), International Hip Outcome Tool (12-items), reoperation rate, and complications at two years postoperatively were retrospectively analyzed.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 70 - 72
1 Nov 2014
Callaghan JJ Liu SS Phruetthiphat O

A common situation presenting to the orthopaedic surgeon today is a worn acetabular liner with substantial acetabular and pelvic osteolysis. The surgeon has many options for dealing with osteolytic defects. These include allograft, calcium based substitutes, demineralised bone matrix, or combinations of these options with or without addition of platelet rich plasma. To date there are no clinical studies to determine the efficacy of using bone-stimulating materials in osteolytic defects at the time of revision surgery and there are surprisingly few studies demonstrating the clinical efficacy of these treatment options. Even when radiographs appear to demonstrate incorporation of graft material CT studies have shown that incorporation is incomplete. The surgeon, in choosing a graft material for a surgical procedure must take into account the efficacy, safety, cost and convenience of that material. Cite this article: Bone Joint J 2014;96-B (11 Suppl A):70–2


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 116 - 121
1 Jul 2021
Inoue D Grace TR Restrepo C Hozack WJ

Aims

Total hip arthroplasty (THA) using the direct anterior approach (DAA) is undertaken with the patient in the supine position, creating an opportunity to replace both hips under one anaesthetic. Few studies have reported simultaneous bilateral DAA-THA. The aim of this study was to characterize a cohort of patients selected for this technique by a single, high-volume arthroplasty surgeon and to investigate their early postoperative clinical outcomes.

Methods

Using an institutional database, we reviewed 643 patients who underwent bilateral DAA-THA by a single surgeon between 1 January 2010 and 31 December 2018. The demographic characteristics of the 256 patients (39.8%) who underwent simultaneous bilateral DAA-THA were compared with the 387 patients (60.2%) who underwent staged THA during the same period of time. We then reviewed the length of stay, rate of discharge home, 90-day complications, and readmissions for the simultaneous bilateral group.


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1035 - 1042
1 Dec 2021
Okowinski M Hjorth MH Mosegaard SB Jürgens-Lahnstein JH Storgaard Jakobsen S Hedevang Christensen P Kold S Stilling M

Aims

Femoral bone preparation using compaction technique has been shown to preserve bone and improve implant fixation in animal models. No long-term clinical outcomes are available. There are no significant long-term differences between compaction and broaching techniques for primary total hip arthroplasty (THA) in terms of migration, clinical, and radiological outcomes.

Methods

A total of 28 patients received one-stage bilateral primary THA with cementless femoral stems (56 hips). They were randomized to compaction on one femur and broaching on the contralateral femur. Overall, 13 patients were lost to the ten-year follow-up leaving 30 hips to be evaluated in terms of stem migration (using radiostereometry), radiological changes, Harris Hip Score, Oxford Hip Score, and complications.


Bone & Joint Open
Vol. 2, Issue 11 | Pages 909 - 920
10 Nov 2021
Smith T Clark L Khoury R Man M Hanson S Welsh A Clark A Hopewell S Pfeiffer K Logan P Crotty M Costa M Lamb SE

Aims

This study aims to assess the feasibility of conducting a pragmatic, multicentre randomized controlled trial (RCT) to test the clinical and cost-effectiveness of an informal caregiver training programme to support the recovery of people following hip fracture surgery.

Methods

This will be a mixed-methods feasibility RCT, recruiting 60 patients following hip fracture surgery and their informal caregivers. Patients will be randomized to usual NHS care, versus usual NHS care plus a caregiver-patient dyad training programme (HIP HELPER). This programme will comprise of three, one-hour, one-to-one training sessions for the patient and caregiver, delivered by a nurse, physiotherapist, or occupational therapist. Training will be delivered in the hospital setting pre-patient discharge. It will include practical skills for rehabilitation such as: transfers and walking; recovery goal setting and expectations; pacing and stress management techniques; and introduction to the HIP HELPER Caregiver Workbook, which provides information on recovery, exercises, worksheets, and goal-setting plans to facilitate a ‘good’ recovery. After discharge, patients and caregivers will be supported in delivering rehabilitation through three telephone coaching sessions. Data, collected at baseline and four months post-randomization, will include: screening logs, intervention logs, fidelity checklists, quality assurance monitoring visit data, and clinical outcomes assessing quality of life, physical, emotional, adverse events, and resource use outcomes. The acceptability of the study intervention and RCT design will be explored through qualitative methods with 20 participants (patients and informal caregivers) and 12 health professionals.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 595 - 602
1 May 2015
McCalden RW Korczak A Somerville L Yuan X Naudie DD

This was a randomised controlled trial studying the safety of a new short metaphyseal fixation (SMF) stem. We hypothesised that it would have similar early clinical results and micromovement to those of a standard-length tapered Synergy metaphyseal fixation stem. Using radiostereometric analysis (RSA) we compared the two stems in 43 patients. A short metaphyseal fixation stem was used in 22 patients and a Synergy stem in 21 patients. No difference was found in the clinical outcomes pre- or post-operatively between groups. RSA showed no significant differences two years post-operatively in mean micromovement between the two stems (except for varus/valgus tilt at p = 0.05) (subsidence 0.94 mm (. sd.  1.71) vs 0.32 mm (. sd. 0.45), p = 0.66; rotation 0.96° (. sd. 1.49) vs 1.41° (. sd. 2.95), p = 0.88; and total migration 1.09 mm (. sd. 1.74) vs 0.73 mm (. sd. 0.72), p = 0.51). A few stems (four SMF and three Synergy) had initial migration > 1.0 mm but stabilised by three to six months, with the exception of one SMF stem which required revision three years post-operatively. For most stems, total micromovement was very low at two years (subsidence < 0.5 mm, rotation < 1.0°, total migration < 0.5 mm), which was consistent with osseous ingrowth. The small sample makes it difficult to confirm the universal applicability of or elucidate the potential contraindications to the use of this particular new design of stem. Cite this article: Bone Joint J 2015; 97-B:595–602


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 84 - 90
1 Jul 2021
Yang J Olsen AS Serino J Terhune EB DeBenedetti A Della Valle CJ

Aims

The proportion of arthroplasties performed in the ambulatory setting has increased considerably. However, there are concerns whether same-day discharge may increase the risk of complications. The aim of this study was to compare 90-day outcomes between inpatient arthroplasties and outpatient arthroplasties performed at an ambulatory surgery centre (ASC), and determine whether there is a learning curve associated with performing athroplasties in an ASC.

Methods

Among a single-surgeon cohort of 970 patients who underwent arthroplasty at an ASC, 854 (88.0%) were matched one-to-one with inpatients based on age, sex, American Society of Anesthesiologists (ASA) grade, BMI, and procedure (105 could not be adequately matched and 11 lacked 90-day follow-up). The cohort included 281 total hip arthroplasties (THAs) (32.9%), 267 unicompartmental knee arthroplasties (31.3%), 242 primary total knee arthroplasties (TKAs) (28.3%), 60 hip resurfacings (7.0%), two revision THAs (0.3%), and two revision TKAs (0.3%). Outcomes included readmissions, reoperations, visits to the emergency department, unplanned clinic visits, and complications.


Bone & Joint Open
Vol. 2, Issue 8 | Pages 611 - 617
10 Aug 2021
Kubik JF Bornes TD Klinger CE Dyke JP Helfet DL

Aims

Surgical treatment of young femoral neck fractures often requires an open approach to achieve an anatomical reduction. The application of a calcar plate has recently been described to aid in femoral neck fracture reduction and to augment fixation. However, application of a plate may potentially compromise the regional vascularity of the femoral head and neck. The purpose of this study was to investigate the effect of calcar femoral neck plating on the vascularity of the femoral head and neck.

Methods

A Hueter approach and capsulotomy were performed bilaterally in six cadaveric hips. In the experimental group, a one-third tubular plate was secured to the inferomedial femoral neck at 6:00 on the clockface. The contralateral hip served as a control with surgical approach and capsulotomy without fixation. Pre- and post-contrast MRI was then performed to quantify signal intensity in the femoral head and neck. Qualitative assessment of the terminal arterial branches to the femoral head, specifically the inferior retinacular artery (IRA), was also performed.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 887 - 892
1 Jul 2007
Cohen AT Skinner JA Warwick D Brenkel I

Little is known about the efficacy of graduated compression stockings in preventing venous thromboembolism after hip surgery. We conducted a prospective, randomised single-blind study to determine whether the addition of compression stockings to fondaparinux conferred any additional benefit. The study included 874 patients, of whom 795 could be evaluated (400 in the fondaparinux group and 395 in the fondaparinux plus compression stocking group). Fondaparinux was given post-operatively for five to nine days, either alone or combined with wearing stockings, which were worn for a mean 42 days (35 to 49). The study outcomes were venous thromboembolism, or sudden death before day 42. Duplex ultrasonography was scheduled within a week of day 42. Safety outcomes were bleeding and death from venous thromboembolism. The prevalence of deep-vein thrombosis was similar in the two groups 5.5% (22 of 400) in the fondaparinux group and 4.8 (19 of 395) in the fondaparinux plus stocking group (odds ratio 0.88, 95% confidence interval 0.46 to 1.65, p = 0.69). Major bleeding occurred in only one patient. The addition of graduated compression stockings to fondaparinux appears to offer no additional benefit over the use of fondaparinux alone


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 639 - 642
1 Jul 2004
Pitto RP Hamer H Heiss-Dunlop W Kuehle J

Routine prophylaxis for venous thromboembolic disease after total hip replacement (THR) is recommended. Pneumatic compression with foot pumps seems to provide an alternative to chemical agents. However, the overall number of patients investigated in randomised clinical trials has been too small to draw evidence-based conclusions. This randomised clinical trial was carried out to compare the effectiveness and safety of mechanical versus chemical prophylaxis of DVT in patients after THR. Inclusion criteria were osteoarthritis of the hip and age less than 80 years. Exclusion criteria included a history of thromboembolic disease, heart disease, and bleeding diatheses. There were 216 consecutive patients considered for inclusion in the trial who were randomised either for management with the A-V Impulse System foot pump. We excluded 16 patients who did not tolerate continuous use of the foot pump or with low-molecular-weight heparin (LMWH). Patients were monitored for DVT using serial duplex sonography at 3, 10 and 45 days after surgery. DVT was detected in three of 100 patients in the foot-pump group and with six of 100 patients in the LMWH group (p < 0.05). The mean post-operative drainage was 259 ml in the foot-pump group and 328 ml in the LMWH group (p < 0.05). Patients in the foot-pump group had less swelling of the thigh (10 mm compared with 15 mm; p < 0.05). One patient developed heparin-induced thrombocytopenia. This study confirms the effectiveness and safety of mechanical prophylaxis of DVT in THR. Some patients cannot tolerate the foot pump


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 53 - 58
1 Jul 2021
Lawrie CM Bechtold D Schwabe M Clohisy JC

Aims

The direct anterior approach (DAA) for total hip arthroplasty (THA) has potential advantages over other approaches and is most commonly performed with the patient in the supine position. We describe a technique for DAA THA with the patient in the lateral decubitus position and report the early clinical and radiological outcomes, the characteristics of the learning curve, and perioperative complications.

Methods

All primary DAA THAs performed in the lateral position by a single surgeon over a four-year period from the surgeon’s first case using the technique were identified from a prospectively collected database. Modified Harris Hip Scores (mHHS) were collected to assess clinical outcome, and routine radiological analysis was performed. Retrospective review of the medical records identified perioperative complications, the characteristics of the learning curve, and revisions.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 10 - 13
1 Jan 2016
Brooks PJ

Hip resurfacing has been proposed as an alternative to traditional total hip arthroplasty in young, active patients. Much has been learned following the introduction of metal-on-metal resurfacing devices in the 1990s. The triad of a well-designed device, implanted accurately, in the correct patient has never been more critical than with these implants. . Following Food and Drug Administration approval in 2006, we studied the safety and effectiveness of one hip resurfacing device (Birmingham Hip Resurfacing) at our hospital in a large, single-surgeon series. We report our early to mid–term results in 1333 cases followed for a mean of 4.3 years (2 to 5.7) using a prospective, observational registry. The mean patient age was 53.1 years (12 to 84); 70% were male and 91% had osteoarthritis. Complications were few, including no dislocations, no femoral component loosening, two femoral neck fractures (0.15%), one socket loosening (0.08%), three deep infections (0.23%), and three cases of metallosis (0.23%). There were no destructive pseudotumours. Overall survivorship at up to 5.7 years was 99.2%. Aseptic survivorship in males under the age of 50 was 100%. We believe this is the largest United States series of a single surgeon using a single resurfacing system. Cite this article: Bone Joint J 2016;98-B (1 Suppl A):10–13


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 103 - 110
1 Jul 2021
Chalmers BP Lebowitz JS Chiu Y Joseph AD Padgett DE Bostrom MPG Gonzalez Della Valle A

Aims

Due to the opioid epidemic in the USA, our service progressively decreased the number of opioid tablets prescribed at discharge after primary hip (THA) and knee (TKA) arthroplasty. The goal of this study was to analyze the effect on total morphine milligram equivalents (MMEs) prescribed and post-discharge opioid repeat prescriptions.

Methods

We retrospectively reviewed 19,428 patients undergoing a primary THA or TKA between 1 February 2016 and 31 December 2019. Two reductions in the number of opioid tablets prescribed at discharge were implemented over this time; as such, we analyzed three periods (P1, P2, and P3) with different routine discharge MME (750, 520, and 320 MMEs, respectively). We investigated 90-day refill rates, refill MMEs, and whether discharge MMEs were associated with represcribing in a multivariate model.


Bone & Joint Open
Vol. 2, Issue 2 | Pages 93 - 102
1 Feb 2021
Thompson JW Wignadasan W Ibrahim M Beasley L Konan S Plastow R Magan A Haddad FS

Aims

We present the development of a day-case total hip arthroplasty (THA) pathway in a UK National Health Service institution in conjunction with an extensive evidence-based summary of the interventions used to achieve successful day-case THA to which the protocol is founded upon.

Methods

We performed a prospective audit of day-case THA in our institution as we reinitiate our full capacity elective services. In parallel, we performed a review of the literature reporting complication or readmission rates at ≥ 30-day postoperative following day-case THA. Electronic searches were performed using four databases from the date of inception to November 2020. Relevant studies were identified, data extracted, and qualitative synthesis performed.


Bone & Joint Open
Vol. 2, Issue 5 | Pages 293 - 300
3 May 2021
Lewis PM Khan FJ Feathers JR Lewis MH Morris KH Waddell JP

Aims

“Get It Right First Time” (GIRFT) and NHS England’s Best Practice Tariff (BPT) have published directives advising that patients over the ages of 65 (GIRFT) and 69 years (BPT) receiving total hip arthroplasty (THA) should receive cemented implants and have brought in financial penalties if this policy is not observed. Despite this, worldwide, uncemented component use has increased, a situation described as a ‘paradox’. GIRFT and BPT do, however, acknowledge more data are required to support this edict with current policies based on the National Joint Registry survivorship and implant costs.

Methods

This study compares THA outcomes for over 1,000 uncemented Corail/Pinnacle constructs used in all age groups/patient frailty, under one surgeon, with identical pre- and postoperative pathways over a nine-year period with mean follow-up of five years and two months (range: nine months to nine years and nine months). Implant information, survivorship, and regular postoperative Oxford Hip Scores (OHS) were collected and two comparisons undertaken: a comparison of those aged over 65 years with those 65 and under and a second comparison of those aged 70 years and over with those aged under 70.


Aims

Intravenous dexamethasone has been shown to reduce immediate postoperative pain after total hip arthroplasty (THA), though the effects are short-lived. We aimed to assess whether two equivalent perioperative split doses were more effective than a single preoperative dose.

Methods

A total of 165 patients were randomly assigned into three groups: two perioperative saline injections (Group A, placebo), a single preoperative dose of 20 mg dexamethasone and a postoperative saline injection (Group B), and two perioperative doses of 10 mg dexamethasone (Group C). Patients, surgeons, and staff collecting outcome data were blinded to allocation. The primary outcome was postoperative pain level reported on a ten-point Numerical Rating Scale (NRS) at rest and during activity. The use of analgesic and antiemetic rescue, incidence of postoperative nausea and vomiting (PONV), CRP and interleukin-6 (IL-6) levels, range of motion (ROM), length of stay (LOS), patient satisfaction, and the incidence of surgical site infection (SSI) and gastrointestinal bleeding (GIB) in the three months postoperatively, were also compared.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 298 - 303
1 Mar 2006
Bhan S Pankaj A Malhotra R

We compared the safety and outcome of one-stage bilateral total hip arthroplasty with those of a two-stage procedure during different admissions in a prospective, randomised controlled trial in an Asian population. Of 168 patients included in the study, 83 had a single- and 85 a two-stage procedure. Most of the patients (59.9%) suffered from inflammatory arthritis. The intra-operative complications, early systemic complications, the operating time, positioning of the components, the functional score, restoration of limb length and survival rates at 96 months were similar in the two groups. The total estimated blood loss was significantly lower in patients undergoing a one-stage procedure than in patients who had a two-stage procedure, but the transfusion requirements were significantly higher in the former group (p = 0.001). The hospital stay was significantly shorter in the one-stage group, 7.25 days (. sd. 1.30; 5 to 20) compared with 10 days (. sd. 1.65; 8 to 24) in the two-stage group (p = 0.023). We believe that a one-stage procedure is safe and appropriate in our population


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 650 - 658
1 Apr 2021
Konow T Baetz J Melsheimer O Grimberg A Morlock M

Aims

Periprosthetic femoral fractures (PPF) are a serious complication of total hip arthroplasty (THA) and are becoming an increasingly common indication for revision arthroplasty with the ageing population. This study aimed to identify potential risk factors for PPF based on an analysis of registry data.

Methods

Cases recorded with PPF as the primary indication for revision arthroplasty in the German Arthroplasty Registry (Endoprothesenregister Deutschland (EPRD)), as well as those classified as having a PPF according to the International Classification of Diseases (ICD) codes in patients’ insurance records were identified from the complete datasets of 249,639 registered primary hip arthroplasties in the EPRD and included in the analysis.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 935 - 940
1 Jul 2010
McCalden RW Charron KD Yuan X Bourne RB Naudie DD MacDonald SJ

This was a safety study where the hypothesis was that the newer-design CPCS femoral stem would demonstrate similar early clinical results and micromovement to the well-established Exeter stem. Both are collarless, tapered, polished cemented stems, the only difference being a slight lateral to medial taper with the CPCS stem. A total of 34 patients were enrolled in a single-blinded randomised controlled trial in which 17 patients received a dedicated radiostereometric CPCS stem and 17 a radiostereometric Exeter stem. No difference was found in any of the outcome measures pre-operatively or post-operatively between groups. At two years, the mean subsidence for the CPCS stem was nearly half that seen for the Exeter stem (0.77 mm (−0.943 to 1.77) and 1.25 mm (0.719 to 1.625), respectively; p = 0.032). In contrast, the mean internal rotation of the CPCS stem was approximately twice that of the Exeter (1.61° (−1.07° to 4.33°) and 0.59° (0.97° to 1.64°), respectively; p = 0.048). Other migration patterns were not significantly different between the stems. The subtle differences in designs may explain the different patterns of migration. Comparable migration with the Exeter stem suggests that the CPCS design will perform well in the long term


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 166 - 168
1 Feb 2007
Chitre AR Fehily MJ Bamford DJ

Intra-articular injections of steroid into the hip are used for a variety of reasons in current orthopaedic practice. Recently their safety prior to ipsilateral total hip replacement has been called into question owing to concerns about deep joint infection. We undertook a retrospective analysis of all patients who had undergone local anaesthetic and steroid injections followed by ipsilateral total hip replacement over a five-year period. Members of the surgical team, using a lateral approach to the hip, performed all the injections in the operating theatre using a strict aseptic technique. The mean time between injection and total hip replacement was 18 months (4 to 50). The mean follow-up after hip replacement was 25.8 months (9 to 78), during which time no case of deep joint sepsis was found. In our series, ipsilateral local anaesthetic and steroid injections have not conferred an increased risk of infection in total hip replacement. We believe that the practice of intra-articular local anaesthetic and steroid injections to the hip followed by total hip replacement is safer than previously reported


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 57 - 61
1 Jul 2020
Woolson ST

Aims

To establish whether there was a consensus among the members of the Hip Society (HS) on the role of direct anterior approach (DAA) contemporary primary total hip arthroplasty (THA).

Methods

An online survey was sent to all 112 active and senior members of the HS, to which 71 members responded. The survey was constructed to determine whether they believed that evidence-based medicine proves, in modern clinical practice, that the DAA has significant benefits compared to risks when contrasted with other approaches. In addition, they were asked if they currently used the DAA.


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1151 - 1157
14 Sep 2020
Levack AE McLawhorn AS Dodwell E DelPizzo K Nguyen J Sink E

Aims

Tranexamic acid (TXA) has been shown to reduce blood loss and transfusion requirements in patients undergoing orthopaedic surgery. There remains a lack of prospective evidence for the use of TXA in patients undergoing periacetabular osteotomy (PAO). The purpose of this study was to determine if intravenous (IV) TXA is effective in reducing calculated blood loss and transfusions after PAO.

Methods

This was a single-centre prospective double-blind placebo-controlled randomized trial of 81 patients aged 12 to 45 years undergoing elective PAO by a single surgeon. The intervention group (n = 40) received two doses of IV TXA of a maximum 1 g in each dose; the control group (n = 41) received two doses of 50 ml 0.9% saline IV. The primary outcome was perioperative calculated blood loss. Secondary outcomes included allogenic transfusions and six-week postoperative complications.


Bone & Joint Research
Vol. 9, Issue 8 | Pages 515 - 523
1 Aug 2020
Bergiers S Hothi H Henckel J Eskelinen A Skinner J Hart A

Aims

The optimum clearance between the bearing surfaces of hip arthroplasties is unknown. Theoretically, to minimize wear, it is understood that clearances must be low enough to maintain optimal contact pressure and fluid film lubrication, while being large enough to allow lubricant recovery and reduce contact patch size. This study aimed to identify the relationship between diametrical clearance and volumetric wear, through the analysis of retrieved components.

Methods

A total of 81 metal-on-metal Pinnacle hips paired with 12/14 stems were included in this study. Geometrical analysis was performed on each component, using coordinate and roundness measuring machines. The relationship between their as-manufactured diametrical clearance and volumetric wear was investigated. The Mann-Whitney U test and unpaired t-test were used, in addition to calculating the non-parametric Spearman's correlation coefficient, to statistically evaluate the acquired data.


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 104 - 109
1 Jun 2019
Hines JT Hernandez NM Amundson AW Pagnano MW Sierra RJ Abdel MP

Aims

Tranexamic acid (TXA) has been shown to significantly reduce transfusion rates in primary total hip arthroplasties (THAs), but high-quality evidence is limited in the revision setting. The purpose of the current study was to compare the rate of blood transfusions and symptomatic venous thromboembolic events (VTEs) in a large cohort of revision THAs treated with or without intravenous (IV) TXA.

Patients and Methods

We performed a retrospective review of 3264 revision THAs (2645 patients) between 2005 and 2014, of which 1142 procedures received IV TXA (1 g at incision and 1 g at closure). The mean age in the revision group with TXA was 65 years (28 to 95), with 579 female patients (51%). The mean age in the revision group treated without TXA was 67 years (21 to 98), with 1160 female patients (55%). Outcomes analyzed included rates of transfusion and symptomatic VTEs between procedures undertaken with and without TXA. These comparisons were performed for the overall cohort, as well as within cases subcategorized for aseptic or septic aetiologies. A propensity score was developed to minimize bias between groups and utilized age at revision THA, sex, body mass index, American Society of Anesthesiologists (ASA) score, preoperative anticoagulation, and year of surgery.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 191 - 197
1 Feb 2020
Gabor JA Padilla JA Feng JE Schnaser E Lutes WB Park KJ Incavo S Vigdorchik J Schwarzkopf R

Aims

Although good clinical outcomes have been reported for monolithic tapered, fluted, titanium stems (TFTS), early results showed high rates of subsidence. Advances in stem design may mitigate these concerns. This study reports on the use of a current monolithic TFTS for a variety of indications.

Methods

A multi-institutional retrospective study of all consecutive total hip arthroplasty (THA) and revision total hip arthroplasty (rTHA) patients who received the monolithic TFTS was conducted. Surgery was performed by eight fellowship-trained arthroplasty surgeons at four institutions. A total of 157 hips in 153 patients at a mean follow-up of 11.6 months (SD7.8) were included. Mean patient age at the time of surgery was 67.4 years (SD 13.3) and mean body mass index (BMI) was 28.9 kg/m2 (SD 6.5). Outcomes included intraoperative complications, one-year all-cause re-revisions, and subsidence at postoperative time intervals (two weeks, six weeks, six months, nine months, and one year).


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 9 - 15
1 Jun 2019
Wyles CC Hevesi M Osmon DR Park MA Habermann EB Lewallen DG Berry DJ Sierra RJ

Aims

The aims of this study were to characterize antibiotic choices for perioperative total knee arthroplasty (TKA) and total hip arthroplasty (THA) prophylaxis, assess antibiotic allergy testing efficacy, and determine rates of prosthetic joint infection (PJI) based on perioperative antibiotic regimen.

Patients and Methods

We evaluated all patients undergoing primary TKA or THA at a single academic institution between January 2004 and May 2017, yielding 29 695 arthroplasties (22 705 patients), with 3411 arthroplasties in 2576 patients (11.5%) having undergone preoperative allergy testing. A series of institutional databases were combined to identify allergy consultation outcomes, perioperative antibiotic regimen, and infection-free survivorship until final follow-up.


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 82 - 89
1 Jan 2020
Coenders MJ Mathijssen NMC Vehmeijer SBW

Aims

The aim of this study was to report our experience at 3.5 years with outpatient total hip arthroplasty (THA).

Methods

In this prospective cohort study, we included all patients who were planned to receive primary THA through the anterior approach between 1 April 2014 and 1 October 2017. Patient-related data and surgical information were recorded. Patient reported outcome measures (PROMs) related to the hip and an anchor question were taken preoperatively, at six weeks, three months, and one year after surgery. All complications, readmissions, and reoperations were registered.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 207 - 212
1 Feb 2019
Clavé A Gérard R Lacroix J Baynat C Danguy des Déserts M Gatineau F Mottier D

Aims

Cementless primary total hip arthroplasty (THA) is associated with risks of bleeding and thromboembolism. Anticoagulants are effective as venous thromboprophylaxis, but with an increased risk of bleeding. Tranexamic acid (TXA) is an efficient antifibrinolytic agent, but the mode and timing of its administration remain controversial. This study aimed to determine whether two intravenous (IV) TXA regimens (a three-hour two-dose (short-TXA) and 11-hour four-dose (long-TXA)) were more effective than placebo in reducing perioperative real blood loss (RBL, between baseline and day 3 postoperatively) in patients undergoing THA who receive rivaroxaban as thromboprophylaxis. The secondary aim was to assess the non-inferiority of the reduction of blood loss of the short protocol versus the long protocol.

Patients and Methods

A multicentre, prospective, randomized, double-blind, placebo-controlled trial was undertaken involving 229 patients undergoing primary cementless THA using a posterior approach, whose extended rivaroxaban thromboprophylaxis started on the day of surgery. There were 98 male and 131 female patients, with a mean age of 65.5 years (32 to 91). The primary outcome, perioperative RBL, was evaluated at 72 hours postoperatively. The efficacy of short- and long-TXA protocols in the reduction of perioperative RBL was compared with a placebo group.


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1585 - 1592
1 Dec 2019
Logishetty K Rudran B Cobb JP

Aims

Arthroplasty skills need to be acquired safely during training, yet operative experience is increasingly hard to acquire by trainees. Virtual reality (VR) training using headsets and motion-tracked controllers can simulate complex open procedures in a fully immersive operating theatre. The present study aimed to determine if trainees trained using VR perform better than those using conventional preparation for performing total hip arthroplasty (THA).

Patients and Methods

A total of 24 surgical trainees (seven female, 17 male; mean age 29 years (28 to 31)) volunteered to participate in this observer-blinded 1:1 randomized controlled trial. They had no prior experience of anterior approach THA. Of these 24 trainees, 12 completed a six-week VR training programme in a simulation laboratory, while the other 12 received only conventional preparatory materials for learning THA. All trainees then performed a cadaveric THA, assessed independently by two hip surgeons. The primary outcome was technical and non-technical surgical performance measured by a THA-specific procedure-based assessment (PBA). Secondary outcomes were step completion measured by a task-specific checklist, error in acetabular component orientation, and procedure duration.


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1459 - 1463
1 Nov 2019
Enishi T Yagi H Higuchi T Takeuchi M Sato R Yoshioka S Nakamura M Nakano S

Aims

Rotational acetabular osteotomy (RAO) is an effective joint-preserving surgical treatment for acetabular dysplasia. The purpose of this study was to investigate changes in muscle strength, gait speed, and clinical outcome in the operated hip after RAO over a one-year period using a standard protocol for rehabilitation.

Patients and Methods

A total of 57 patients underwent RAO for acetabular dysplasia. Changes in muscle strength of the operated hip, 10 m gait speed, Japanese Orthopaedic Association (JOA) hip score, and factors correlated with hip muscle strength after RAO were retrospectively analyzed.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 760 - 767
1 Jul 2019
Galea VP Rojanasopondist P Laursen M Muratoglu OK Malchau H Bragdon C

Aims

Vitamin E-diffused, highly crosslinked polyethylene (VEPE) and porous titanium-coated (PTC) shells were introduced in total hip arthroplasty (THA) to reduce the risk of aseptic loosening. The purpose of this study was: 1) to compare the wear properties of VEPE to moderately crosslinked polyethylene; 2) to assess the stability of PTC shells; and 3) to report their clinical outcomes at seven years.

Patients and Methods

A total of 89 patients were enrolled into a prospective study. All patients received a PTC shell and were randomized to receive a VEPE liner (n = 44) or a moderately crosslinked polyethylene (ModXLPE) liner (n = 45). Radiostereometric analysis (RSA) was used to measure polyethylene wear and component migration. Differences in wear were assessed while adjusting for body mass index, activity level, acetabular inclination, anteversion, and head size. Plain radiographs were assessed for radiolucency and patient-reported outcome measures (PROMs) were administered at each follow-up.


Bone & Joint Research
Vol. 8, Issue 10 | Pages 443 - 450
1 Oct 2019
Treacy RBC Holland JP Daniel J Ziaee H McMinn DJW

Objectives

Modern metal-on-metal (MoM) hip resurfacing arthroplasty (HRA), while achieving good results with well-orientated, well-designed components in ideal patients, is contraindicated in women, men with head size under 50 mm, or metal hypersensitivity. These patients currently have no access to the benefits of HRA. Highly crosslinked polyethylene (XLPE) has demonstrated clinical success in total hip arthroplasty (THA) and, when used in HRA, potentially reduces metal ion-related sequelae. We report the early performance of HRA using a direct-to-bone cementless mono-bloc XLPE component coupled with a cobalt-chrome femoral head, in the patient group for whom HRA is currently contraindicated.

Methods

This is a cross-sectional, observational assessment of 88 consecutive metal-on-XLPE HRAs performed in 84 patients between 2015 and 2018 in three centres (three surgeons, including the designer surgeon). Mean follow-up is 1.6 years (0.7 to 3.9). Mean age at operation was 56 years (sd 11; 21 to 82), and 73% of implantations were in female patients. All patients were individually counselled, and a detailed informed consent was obtained prior to operation. Primary resurfacing was carried out in 85 hips, and three cases involved revision of previous MoM HRA. Clinical, radiological, and Oxford Hip Score (OHS) assessments were studied, along with implant survival.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1042 - 1049
1 Sep 2019
Murphy MP Killen CJ Ralles SJ Brown NM Hopkinson WJ Wu K

Aims

Several radiological methods of measuring anteversion of the acetabular component after total hip arthroplasty (THA) have been described. These are limited by low reproducibility, are less accurate than CT 3D reconstruction, and are cumbersome to use. These methods also partly rely on the identification of obscured radiological borders of the component. We propose two novel methods, the Area and Orthogonal methods, which have been designed to maximize use of readily identifiable points while maintaining the same trigonometric principles.

Patients and Methods

A retrospective study of plain radiographs was conducted on 160 hips of 141 patients who had undergone primary THA. We compared the reliability and accuracy of the Area and Orthogonal methods with two of the current leading methods: those of Widmer and Lewinnek, respectively.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 540 - 546
1 May 2019
Juneau D Grammatopoulos G Alzahrani A Thornhill R Inacio JR Dick A Vogel KI Dobransky J Beaulé PE Dwivedi G

Aims

Cardiac magnetic resonance (CMR) was used to assess whether cardiac function or tissue composition was affected in patients with well-functioning metal-on-metal hip resurfacing arthroplasties (MoMHRA) when compared with a group of controls, and to assess if metal ion levels correlated with any of the functional or structural parameters studied.

Patients and Methods

In all, 30 participants with no significant cardiac history were enrolled: 20 patients with well-functioning MoMHRA at mean follow-up of 8.3 years post-procedure (ten unilateral, ten bilateral; 17 men, three women) and a case-matched control group of ten non-MoM total hip arthroplasty patients (six men, four women). The mean age of the whole cohort (study group and controls) at the time of surgery was 50.6 years (41.0 to 64.0). Serum levels of cobalt and chromium were measured, and all patients underwent CMR imaging, including cine, T2* measurements, T1 and T2 mapping, late gadolinium enhancement, and strain measurements.


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 2 - 8
1 Jun 2019
Aggarwal VK Weintraub S Klock J Stachel A Phillips M Schwarzkopf R Iorio R Bosco J Zuckerman JD Vigdorchik JM Long WJ

Aims

We studied the impact of direct anterior (DA) versus non-anterior (NA) surgical approaches on prosthetic joint infection (PJI), and examined the impact of new perioperative protocols on PJI rates following all surgical approaches at a single institution.

Patients and Methods

A total of 6086 consecutive patients undergoing primary total hip arthroplasty (THA) at a single institution between 2013 and 2016 were retrospectively evaluated. Data obtained from electronic patient medical records included age, sex, body mass index (BMI), medical comorbidities, surgical approach, and presence of deep PJI. There were 3053 male patients (50.1%) and 3033 female patients (49.9%). The mean age and BMI of the entire cohort was 62.7 years (18 to 102, sd 12.3) and 28.8 kg/m2 (13.3 to 57.6, sd 6.1), respectively. Infection rates were calculated yearly for the DA and NA approach groups. Covariates were assessed and used in multivariate analysis to calculate adjusted odds ratios (ORs) for risk of development of PJI with DA compared with NA approaches. In order to determine the effect of adopting a set of infection prevention protocols on PJI, we calculated ORs for PJI comparing patients undergoing THA for two distinct time periods: 2013 to 2014 and 2015 to 2016. These periods corresponded to before and after we implemented a set of perioperative infection protocols.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1424 - 1433
1 Nov 2018
Amstutz HC Le Duff MJ

Aims

This study presents the long-term survivorship, risk factors for prosthesis survival, and an assessment of the long-term effects of changes in surgical technique in a large series of patients treated by metal-on-metal (MoM) hip resurfacing arthroplasty (HRA).

Patients and Methods

Between November 1996 and January 2012, 1074 patients (1321 hips) underwent HRA using the Conserve Plus Hip Resurfacing System. There were 787 men (73%) and 287 women (27%) with a mean age of 51 years (14 to 83). The underlying pathology was osteoarthritis (OA) in 1003 (75.9%), developmental dysplasia of the hip (DDH) in 136 (10.3%), avascular necrosis in 98 (7.4%), and other conditions, including inflammatory arthritis, in 84 (6.4%).


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1551 - 1558
1 Dec 2018
Clohisy JC Pascual-Garrido C Duncan S Pashos G Schoenecker PL

Aims

The aims of this study were to review the surgical technique for a combined femoral head reduction osteotomy (FHRO) and periacetabular osteotomy (PAO), and to report the short-term clinical and radiological results of a combined FHRO/PAO for the treatment of selected severe femoral head deformities.

Patients and Methods

Between 2011 and 2016, six female patients were treated with a combined FHRO and PAO. The mean patient age was 13.6 years (12.6 to 15.7). Clinical data, including patient demographics and patient-reported outcome scores, were collected prospectively. Radiologicalally, hip morphology was assessed evaluating the Tönnis angle, the lateral centre to edge angle, the medial offset distance, the extrusion index, and the alpha angle.


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1320 - 1329
1 Oct 2018
Metcalfe D Peterson N Wilkinson JM Perry DC

Aims

The aim of this study was to describe temporal trends and survivorship of total hip arthroplasty (THA) in very young patients, aged ≤ 20 years.

Patients and Methods

A descriptive observational study was undertaken using data from the National Joint Registry (NJR) for England, Wales, Northern Ireland and the Isle of Man between April 2003 and March 2017. All patients aged ≤ 20 years at the time of THA were included and the primary outcome was revision surgery. Descriptive statistics were used to summarize the data and Kaplan–Meier estimates calculated for the cumulative implant survival.


Aims

The aim of this study was to examine the efficacy and safety of multiple boluses of intravenous (IV) tranexamic acid (TXA) on the hidden blood loss (HBL) and inflammatory response following primary total hip arthroplasty (THA).

Patients and Methods

A total of 150 patients were allocated randomly to receive a single bolus of 20 mg/kg IV TXA before the incision (group A), a single bolus followed by a second bolus of 1 g IV-TXA three hours later (group B) or a single bolus followed by two boluses of 1 g IV-TXA three and six hours later (group C). All patients were treated using a standard peri-operative enhanced recovery protocol. Primary outcomes were HBL and the level of haemoglobin (Hb) as well as the levels of C-reactive protein (CRP) and interleukin-6 (IL-6) as markers of inflammation. Secondary outcomes included the length of stay in hospital and the incidence of venous thromboembolism (VTE).


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 867 - 874
1 Jul 2018
Makarewich CA Anderson MB Gililland JM Pelt CE Peters CL

Aims

For this retrospective cohort study, patients aged ≤ 30 years (very young) who underwent total hip arthroplasty (THA) were compared with patients aged ≥ 60 years (elderly) to evaluate the rate of revision arthroplasty, implant survival, the indications for revision, the complications, and the patient-reported outcomes.

Patients and Methods

We retrospectively reviewed all patients who underwent primary THA between January 2000 and May 2015 from our institutional database. A total of 145 very young and 1359 elderly patients were reviewed. The mean follow-up was 5.3 years (1 to 18). Logistic generalized estimating equations were used to compare characteristics and the revision rate. Survival was evaluated using Kaplan–Meier curves and hazard rates were created using Cox regression.


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 853 - 861
1 Jul 2018
Leunig M Hutmacher JE Ricciardi BF Impellizzeri FM Rüdiger HA Naal FD

Aims

The classical longitudinal incision used for the direct anterior approach (DAA) to the hip does not follow the tension lines of the skin and can lead to impaired wound healing and poor cosmesis. The purpose of this retrospective study was to determine the satisfaction with the scar, and functional and radiographic outcomes comparing the classic longitudinal incision with a modified skin crease ‘bikini’ when the DAA is used for total hip arthroplasty (THA).

Patients and Methods

A total of 964 patients (51% female; 59% longitudinal, 41% ‘bikini’) completed a follow-up questionnaire between two and four years postoperatively, including the Oxford Hip Score (OHS), the University of North Carolina ‘4P’ scar scale (UNC4P) and two items for assessing the aesthetic appearance of the scar and symptoms of numbness. The positioning of the components, rates of heterotopic ossification (HO) and rates of revision were assessed.


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 143 - 151
1 Feb 2018
Bovonratwet P Malpani R Ottesen TD Tyagi V Ondeck NT Rubin LE Grauer JN

Aims

The aim of this study was to compare the rate of perioperative complications following aseptic revision total hip arthroplasty (THA) in patients aged ≥ 80 years with that in those aged < 80 years, and to identify risk factors for the incidence of serious adverse events in those aged ≥ 80 years using a large validated national database.

Patients and Methods

Patients who underwent aseptic revision THA were identified in the 2005 to 2015 National Surgical Quality Improvement Program (NSQIP) database and stratified into two age groups: those aged < 80 years and those aged ≥ 80 years. Preoperative and procedural characteristics were compared. Multivariate regression analysis was used to compare the risk of postoperative complications and readmission. Risk factors for the development of a serious adverse event in those aged ≥ 80 years were characterized.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 724 - 731
1 Jun 2017
Mei-Dan O Jewell D Garabekyan T Brockwell J Young DA McBryde CW O’Hara JN

Aims

The aim of this study was to evaluate the long-term clinical and radiographic outcomes of the Birmingham Interlocking Pelvic Osteotomy (BIPO).

Patients and Methods

In this prospective study, we report the mid- to long-term clinical outcomes of the first 100 consecutive patients (116 hips; 88 in women, 28 in men) undergoing BIPO, reflecting the surgeon’s learning curve. Failure was defined as conversion to hip arthroplasty. The mean age at operation was 31 years (7 to 57). Three patients (three hips) were lost to follow-up.


Bone & Joint 360
Vol. 4, Issue 5 | Pages 34 - 36
1 Oct 2015
Starkie R


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1322 - 1327
1 Oct 2015
Gray BL Stambough JB Baca GR Schoenecker PL Clohisy JC

We report patient-reported outcomes and complications associated with contemporary periacetabular osteotomy (PAO) surgery in treating symptomatic acetabular dysplasia and compare these outcomes with total hip arthroplasty (THA) in patients with similar demographic details. Two consecutive cohorts included patients between aged 18 to 40 years who had undergone either PAO (100 hips; 24 male, 76 female) or THA (55 hips; 18 male, 37 female). At a mean follow-up of 5.9 years (2 to 13), there was significant improvement in the modified Harris hip pain (p < 0.001, PAO and p < 0.001, THA), function (p < 0.001, PAO and p = 0.001, THA), and total scores (p < 0.001, PAO and p < 0.001, THA) within each cohort. There were no significant differences in the clinical outcome scores between the groups. Complication rates were low and similar in each cohort (p = 0.68). Similar to THA, contemporary PAO surgery is a clinically effective procedure that improves function and activity levels, provides pain relief and is associated with an acceptable complication rate.

Cite this article: Bone Joint J 2015;97-B:1322–7.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 589 - 594
1 May 2016
Kornuijt A Das D Sijbesma T van der Weegen W

Aims

In order to prevent dislocation of the hip after total hip arthroplasty (THA), patients have to adhere to precautions in the early post-operative period. The hypothesis of this study was that a protocol with minimal precautions after primary THA using the posterolateral approach would not increase the short-term (less than three months) risk of dislocation.

Patients and Methods

We prospectively monitored a group of unselected patients undergoing primary THA managed with standard precautions (n = 109, median age 68.9 years; interquartile range (IQR) 61.2 to 77.3) and a group who were managed with fewer precautions (n = 108, median age 67.2 years; IQR 59.8 to 73.2). There were no significant differences between the groups in relation to predisposing risk factors. The diameter of the femoral head ranged from 28 mm to 36 mm; meticulous soft-tissue repair was undertaken in all patients. The medical records were reviewed and all patients were contacted three months post-operatively to confirm whether they had experienced a dislocation.


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 22 - 28
1 Jan 2017
Khan OH Malviya A Subramanian P Agolley D Witt JD

Aims

Periacetabular osteotomy is an effective way of treating symptomatic hip dysplasia. We describe a new minimally invasive technique using a modification of the Smith-Peterson approach.

We performed a prospective, longitudinal cohort study to assess for any compromise in acetabular correction when using this approach, and to see if the procedure would have a higher complication rate than that quoted in the literature for other approaches. We also assessed for any improvement in functional outcome.

Patients and Methods

From 168 consecutive patients (189 hips) who underwent acetabular correction between March 2010 and March 2013 we excluded those who had undergone previous pelvic surgery for DDH and those being treated for acetabular retroversion. The remaining 151 patients (15 men, 136 women) (166 hips) had a mean age of 32 years (15 to 56) and the mean duration of follow-up was 2.8 years (1.2 to 4.5). In all 90% of cases were Tönnis grade 0 or 1. Functional outcomes were assessed using the Non Arthritic Hip Score (NAHS), University of California, Los Angeles (UCLA) and Tegner activity scores.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 883 - 889
1 Jul 2015
Jassim SS Patel S Wardle N Tahmassebi J Middleton R Shardlow DL Stephen A Hutchinson J Haddad FS

Oxidised zirconium (OxZi) has been developed as an alternative bearing surface for femoral heads in total hip arthroplasty (THA). This study has investigated polyethylene wear, functional outcomes and complications, comparing OxZi and cobalt–chrome (CoCr) as part of a three-arm, multicentre randomised controlled trial. Patients undergoing THA from four institutions were prospectively randomised into three groups. Group A received a CoCr femoral head and highly cross-linked polyethylene (XLPE) liner; Group B received an OxZi femoral head and XLPE liner; Group C received an OxZi femoral head and ultra-high molecular weight polyethylene (UHMWPE) liner. At five years, 368 patients had no statistically significant differences in short-form-36 (p = 0.176 mental, p = 0.756 physical), Western Ontario and McMaster Universities Osteoarthritis Index (p = 0.847), pain scores (p = 0.458) or complications. The mean rate of linear wear was 0.028 mm/year (standard deviation (sd) 0.010) for Group A, 0.023 mm/year (sd 0.010) for Group B, and 0.09 mm/year (sd 0.045) for Group C. Penetration was significantly higher in the UHMWPE liner group compared with both XLPE liner groups (p < 0.001) but no significant difference was noted between CoCr and OxZi when articulating with XLPE (p = 0.153). In this, the largest randomised study of this bearing surface, it appears that using a XLPE acetabular liner is more important in reducing THA component wear than the choice of femoral head bearing, at mid-term follow-up. There is a non-significant trend towards lower wear, coupling OxZi rather than CoCr with XLPE but long-term analysis is required to see if this observation changes with time and becomes significant.

Cite this article: Bone Joint J 2015;97-B:883–9.


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1333 - 1341
1 Oct 2016
van der Voort P Valstar ER Kaptein BL Fiocco M van der Heide HJL Nelissen RGHH

Aims

The widely used and well-proven Palacos R (a.k.a. Refobacin Palacos R) bone cement is no longer commercially available and was superseded by Refobacin bone cement R and Palacos R + G in 2005. However, the performance of these newly introduced bone cements have not been tested in a phased evidence-based manner, including roentgen stereophotogrammetric analysis (RSA).

Patients and Methods

In this blinded, randomised, clinical RSA study, the migration of the Stanmore femoral component was compared between Refobacin bone cement R and Palacos R + G in 62 consecutive total hip arthroplasties. The primary outcome measure was femoral component migration measured using RSA and secondary outcomes were Harris hip score (HHS), Hip disability and Osteoarthritis Outcome Score (HOOS), EuroQol 5D (EQ-5D) and Short Form 36 (SF-36).


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 730 - 735
1 Jun 2016
Bsat S Frei H Beaulé PE

The acetabular labrum is a soft-tissue structure which lines the acetabular rim of the hip joint. Its role in hip joint biomechanics and joint health has been of particular interest over the past decade. In normal hip joint biomechanics, the labrum is crucial in retaining a layer of pressurised intra-articular fluid for joint lubrication and load support/distribution. Its seal around the femoral head is further regarded as a contributing to hip stability through its suction effect. The labrum itself is also important in increasing contact area thereby reducing contact stress. Given the labrum’s role in normal hip joint biomechanics, surgical techniques for managing labral damage are continuously evolving as our understanding of its anatomy and function continue to progress. The current paper aims to review the anatomy and biomechanical function of the labrum and how they are affected by differing surgical techniques.

Take home message: The acetabular labrum plays a critical role in hip function and maintaining and restoring its function during surgical intervention remain an essential goal.

Cite this article: Bone Joint J 2016;98-B:730–5.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1027 - 1035
1 Aug 2016
Pereira LC Kerr J Jolles BM

Aims

Using a systematic review, we investigated whether there is an increased risk of post-operative infection in patients who have received an intra-articular corticosteroid injection to the hip for osteoarthritis prior to total hip arthroplasty (THA).

Methods

Studies dealing with an intra-articular corticosteroid injection to the hip and infection following subsequent THA were identified from databases for the period between 1990 to 2013. Retrieved articles were independently assessed for their methodological quality.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 291 - 297
1 Mar 2016
Rogmark C Leonardsson O

This review summarises the evidence for the treatment of displaced fractures of the femoral neck in elderly patients. Results from randomised clinical trials and national register studies are presented when available.

The advantages of arthroplasty compared with internal fixation are supported by several studies. A number of studies contribute to the discussions of total hip arthroplasty (THA) versus hemiarthroplasty and unipolar versus bipolar hemiarthroplasty, but no clear-cut evidence-based recommendation can be made. THA may be particularly advantageous for active, lucid patients with a relatively long life expectancy. For patients who are physiologically older, hemiarthoplasty is probably satisfactory, and for the oldest patients with more comorbidities, unipolar implants are considered to be sufficient. If the hospital can support emergency THA surgery in sufficient numbers and quality, there may be few patients who warrant bipolar hemiarthroplasty.

The direct lateral approach reduces the risk of dislocation compared with the posterior approach. Cemented implants lower the risk of periprosthetic fracture and its subsequent morbidity and mortality. As the risk of peri-operative death related to bone cement can be reduced by adequate measures, cemented implants are recommended in fracture cases.

Take home message: There remains a great variation in the surgical management of patients with a hip fracture, and an evidence-based approach should improve the outcomes for this vulnerable patient group.

Cite this article: Bone Joint J 2016;98-B:291–7.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1175 - 1182
1 Sep 2015
Bisseling P de Wit BWK Hol AM van Gorp MJ van Kampen A van Susante JLC

Patients from a randomised trial on resurfacing hip arthroplasty (RHA) (n = 36, 19 males; median age 57 years, 24 to 65) comparing a conventional 28 mm metal-on-metal total hip arthroplasty (MoM THA) (n = 28, 17 males; median age 59 years, 37 to 65) and a matched control group of asymptomatic patients with a 32 mm ceramic-on-polyethylene (CoP) THA (n = 33, 18 males; median age 63 years, 38 to 71) were cross-sectionally screened with metal artefact reducing sequence-MRI (MARS-MRI) for pseudotumour formation at a median of 55 months (23 to 72) post-operatively. MRIs were scored by consensus according to three different classification systems for pseudotumour formation.

Clinical scores were available for all patients and metal ion levels for MoM bearing patients.

Periprosthetic lesions with a median volume of 16 mL (1.5 to 35.9) were diagnosed in six patients in the RHA group (17%), one in the MoM THA group (4%) and six in the CoP group (18%). The classification systems revealed no clear differences between the groups. Solid lesions (n = 3) were exclusively encountered in the RHA group. Two patients in the RHA group and one in the MoM THA group underwent a revision for pseudotumour formation. There was no statistically significant relationship between clinical scoring, metal ion levels and periprosthetic lesions in any of the groups.

Periprosthetic fluid collections are seen on MARS-MRI after conventional CoP THA and RHA and may reflect a soft-tissue collection or effusion.

Currently available MRI classification systems seem to score these collections as pseudotumours, causing an-overestimatation of the incidence of pseudotumours.

Cite this article: Bone Joint J 2015;97-B:1175–82.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1011 - 1021
1 Aug 2013
Krishnan H Krishnan SP Blunn G Skinner JA Hart AJ

Following the recall of modular neck hip stems in July 2012, research into femoral modularity will intensify over the next few years. This review aims to provide surgeons with an up-to-date summary of the clinically relevant evidence. The development of femoral modularity, and a classification system, is described. The theoretical rationale for modularity is summarised and the clinical outcomes are explored. The review also examines the clinically relevant problems reported following the use of femoral stems with a modular neck.

Joint replacement registries in the United Kingdom and Australia have provided data on the failure rates of modular devices but cannot identify the mechanism of failure. This information is needed to determine whether modular neck femoral stems will be used in the future, and how we should monitor patients who already have them implanted.

Cite this article: Bone Joint J 2013;95-B:1011–21.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 734 - 740
1 Jun 2015
den Hartog YM Mathijssen NMC van Dasselaar NT Langendijk PNJ Vehmeijer SBW

Only limited data are available regarding the infiltration of local anaesthetic for total hip arthroplasty (THA), and no studies were performed for THA using the anterior approach.

In this prospective, randomised placebo-controlled study we investigated the effect of both standard and reverse infiltration of local anaesthetic in combination with the anterior approach for THA. The primary endpoint was the mean numeric rating score for pain four hours post-operatively. In addition, we recorded the length of hospital stay, the operating time, the destination of the patient at discharge, the use of pain medication, the occurrence of side effects and pain scores at various times post-operatively.

Between November 2012 and January 2014, 75 patients were included in the study. They were randomised into three groups: standard infiltration of local anaesthetic, reversed infiltration of local anaesthetic, and placebo. There was no difference in mean numeric rating score for pain four hours post-operatively (p = 0.87). There were significantly more side effects at one and eight hours post-operatively in the placebo group (p = 0.02; p = 0.03), but this did not influence the mobilisation of the patients. There were no differences in all other outcomes between the groups.

We found no clinically relevant effect when the infiltration of local anaesthetic with ropivacaine and epinephrine was used in a multimodal pain protocol for THA using the anterior approach.

Cite this article: Bone Joint J 2015; 97-B:734–40.


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 458 - 462
1 Apr 2015
Nishihara S Hamada M

Tranexamic acid (TXA) has been used to reduce blood loss during total hip arthroplasty (THA), but its use could increase the risk of venous thromboembolic disease (VTE). Several studies have reported that TXA does not increase the prevalence of deep vein thrombosis (DVT), but most of those used routine chemical thromboprophylaxis, thereby masking the potential increased risk of TXA on VTE. We wished to ascertain whether TXA increases the prevalence of VTE in patients undergoing THA without routine chemical thromboprophylaxis. We carried out a retrospective case-control study in 254 patients who underwent a primary THA, 127 of whom received TXA (1 g given pre-operatively) and a control group of 127 who did not. All patients had mechanical but no chemical thomboprophylaxis. Each patient was examined for DVT by bilateral ultrasonography pre-operatively and on post-operative days 1 and 7. TXA was found to statistically significantly increase the incidence of total DVT on post-operative day 7 compared with the control group (24 (18.9%) and 12 (9.4%), respectively; p < 0.05) but most cases of DVT were isolated distal DVT, with the exception of one patient with proximal DVT in each group. One patient in the control group developed a non-fatal symptomatic pulmonary embolism (PE). The use of TXA did not appear to affect the prevalence of either proximal DVT or PE.

Cite this article: Bone Joint J 2015; 97-B:458–62.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 45 - 49
1 Jan 2015
Tokarski AT Novack TA Parvizi J

We hypothesised that the use of tantalum (Ta) acetabular components in revision total hip arthroplasty (THA) was protective against subsequent failure due to infection. We identified 966 patients (421 men, 545 women and 990 hips) who had undergone revision THA between 2000 and 2013. The mean follow up was 40.2 months (3 months to 13.1 years). The mean age of the men and women was 62.3 years (31 to 90) and 65.1 years (25 to 92), respectively.

Titanium (Ti) acetabular components were used in 536 hips while Ta components were used in 454 hips. In total, 73 (7.3%) hips experienced subsequent acetabular failure. The incidence of failure was lower in the Ta group at 4.4% (20/454) compared with 9.9% (53/536) in the Ti group (p < 0.001, odds ratio 2.38; 95% CI 1.37 to 4.27). Among the 144 hips (64 Ta, 80 Ti) for which revision had been performed because of infection, failure due to a subsequent infection was lower in the Ta group at 3.1% (2/64) compared with 17.5% (14/80) for the Ti group (p = 0.006).

Thus, the use of Ta acetabular components during revision THA was associated with a lower incidence of failure from all causes and Ta components were associated with a lower incidence of subsequent infection when used in patients with periprosthetic joint infection.

Cite this article: Bone Joint J 2015;97-B:45–9.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1594 - 1599
1 Dec 2014
Hwang KT Kim YH Kim YS Ryu JA

We investigated the incidence of soft-tissue lesions after small head metal-on-metal total hip replacement (MoM THR). Between December 1993 and May 1999, 149 patients (195 hips) underwent primary cementless MoM THR.

During the follow-up period, three patients (five THRs) died and eight patients (14 THRs) were lost to follow-up. We requested that all patients undergo CT evaluation. After exclusion of five patients (six THRs) who had undergone a revision procedure, and 22 (28 THRs) who were unwilling to take part in this study, 111 patients (142 THRs) were evaluated. There were 63 men (88 THRs) and 48 women (54 THRs) with a mean age of 45.7 years (37 to 56) at the time of surgery. The mean follow-up was 15.4 years (13 to 19). A soft-tissue lesion was defined as an abnormal peri-prosthetic collection of fluid, solid lesion or asymmetrical soft-tissue mass.

At final follow-up, soft-tissue lesions were found in relation to 28 THRs (19.7%), including 25 solid and three cystic lesions. They were found in 20 men and eight women; 26 lesions were asymptomatic and two were symptomatic. The mean maximal diameter of the soft-tissue lesion was 42.3 mm (17 to 135). The relatively high rate of soft-tissue lesions observed with small head MoM THR remains a concern.

Cite this article: Bone Joint J 2014;96-B:1594–9.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1459 - 1463
1 Nov 2014
Lee YK Ha YC Koo KH

Large femoral heads have become popular in total hip replacement (THR) as a method of reducing the risk of dislocation. However, if large heads are used in ceramic-on-ceramic THR, the liner must be thinner, which may increase the risk of fracture. To compare the rates of ceramic fracture and dislocation between 28 mm and 32 mm ceramic heads, 120 hips in 109 patients (51 men and 58 women, mean age 49.2 years) were randomised to THR with either a 28 mm or a 32 mm ceramic articulation. A total of 57/60 hips assigned to the 28 mm group and 55/60 hips assigned to the 32 mm group were followed for at least five years. No ceramic component fractures occured in any patient in either group. There was one dislocation in the 32 mm group and none in the 28 mm group (p = 0.464). No hip had detectable wear, focal osteolysis or prosthetic loosening. In our small study the 32 mm ceramic articulation appeared to be safe in terms of ceramic liner fracture.

Cite this article: Bone Joint J 2014;96-B:1459–63.


Bone & Joint Research
Vol. 3, Issue 11 | Pages 321 - 327
1 Nov 2014
Palmer AJR Ayyar-Gupta V Dutton SJ Rombach I Cooper CD Pollard TC Hollinghurst D Taylor A Barker KL McNally EG Beard DJ Andrade AJ Carr AJ Glyn-Jones S

Aims

Femoroacetabular Junction Impingement (FAI) describes abnormalities in the shape of the femoral head–neck junction, or abnormalities in the orientation of the acetabulum. In the short term, FAI can give rise to pain and disability, and in the long-term it significantly increases the risk of developing osteoarthritis. The Femoroacetabular Impingement Trial (FAIT) aims to determine whether operative or non-operative intervention is more effective at improving symptoms and preventing the development and progression of osteoarthritis.

Methods

FAIT is a multicentre superiority parallel two-arm randomised controlled trial comparing physiotherapy and activity modification with arthroscopic surgery for the treatment of symptomatic FAI. Patients aged 18 to 60 with clinical and radiological evidence of FAI are eligible. Principal exclusion criteria include previous surgery to the index hip, established osteoarthritis (Kellgren–Lawrence ≥ 2), hip dysplasia (centre-edge angle < 20°), and completion of a physiotherapy programme targeting FAI within the previous 12 months. Recruitment will take place over 24 months and 120 patients will be randomised in a 1:1 ratio and followed up for three years. The two primary outcome measures are change in hip outcome score eight months post-randomisation (approximately six-months post-intervention initiation) and change in radiographic minimum joint space width 38 months post-randomisation. ClinicalTrials.gov: NCT01893034.

Cite this article: Bone Joint Res 2014;3:321–7.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1441 - 1448
1 Nov 2014
Bali K Railton P Kiefer GN Powell JN

We report the clinical and radiological outcome of subcapital osteotomy of the femoral neck in the management of symptomatic femoroacetabular impingement (FAI) resulting from a healed slipped capital femoral epiphysis (SCFE). We believe this is only the second such study in the literature.

We studied eight patients (eight hips) with symptomatic FAI after a moderate to severe healed SCFE. There were six male and two female patients, with a mean age of 17.8 years (13 to 29).

All patients underwent a subcapital intracapsular osteotomy of the femoral neck after surgical hip dislocation and creation of an extended retinacular soft-tissue flap. The mean follow-up was 41 months (20 to 84). Clinical assessment included measurement of range of movement, Harris Hip Score (HHS) and Western Ontario and McMaster Universities Osteoarthritis score (WOMAC). Radiological assessment included pre- and post-operative calculation of the anterior slip angle (ASA) and lateral slip angle (LSA), the anterior offset angle (AOA) and centre head–trochanteric distance (CTD). The mean HHS at final follow-up was 92.5 (85 to 100), and the mean WOMAC scores for pain, stiffness and function were 1.3 (0 to 4), 1.4 (0 to 6) and 3.6 (0 to 19) respectively. There was a statistically significant improvement in all the radiological measurements post-operatively. The mean ASA improved from 36.6° (29° to 44°) to 10.3° (5° to 17°) (p <  0.01). The mean LSA improved from 36.6° (31° to 43°) to 15.4° (8° to 21°) (p < 0.01). The mean AOA decreased from 64.4° (50° to 78°) 32.0° (25° to 39°) post-operatively (p < 0.01). The mean CTD improved from -8.2 mm (-13.8 to +3.1) to +2.8 mm (-7.6 to +11.0) (p < 0.01). Two patients underwent further surgery for nonunion. No patient suffered avascular necrosis of the femoral head.

Subcapital osteotomy for patients with a healed SCFE is more challenging than subcapital re-orientation in those with an acute or sub-acute SCFE and an open physis. An effective correction of the deformity, however, can be achieved with relief of symptoms related to impingement.

Cite this article: Bone Joint J 2014;96-B:1441–8.