Our aim was to investigate the predictive factors for the development
of a rebound phenomenon after temporary hemiepiphysiodesis in children
with genu valgum. We studied 37 limbs with idiopathic genu valgum who were treated
with hemiepiphyseal stapling, and with more than six months remaining
growth at removal of the staples. All children were followed until
skeletal maturity or for more than two years after removal of the
staples.Aims
Patients and Methods
Permanent growth arrest of the longer bone is
an option in the treatment of minor leg-length discrepancies. The
use of a tension band plating technique to produce a temporary epiphysiodesis
is appealing as it avoids the need for accurate timing of the procedure
in relation to remaining growth. We performed an animal study to
establish if control of growth in a long bone is possible with tension
band plating. Animals (pigs) were randomised to temporary epiphysiodesis
on either the right or left tibia. Implants were removed after ten
weeks. Both tibiae were examined using MRI at baseline, and after
ten and 15 weeks. The median interphyseal distance was significantly shorter
on the treated tibiae after both ten weeks (p = 0.04) and 15 weeks
(p = 0.04). On T1-weighted images the metaphyseal water
content was significantly reduced after ten weeks on the treated
side (p = 0.04) but returned to values comparable with the untreated
side at 15 weeks (p = 0.14). Return of growth was observed in all
animals after removal of implants. Temporary epiphysiodesis can be obtained using tension band plating.
The technique is not yet in common clinical practice but might avoid
the need for the accurate timing of epiphysiodesis. Cite this article: