Advertisement for orthosearch.org.uk
Results 1 - 50 of 300
Results per page:
Bone & Joint Research
Vol. 1, Issue 6 | Pages 118 - 124
1 Jun 2012
Grawe B Le T Williamson S Archdeacon A Zardiackas L

Objectives. We aimed to further evaluate the biomechanical characteristics of two locking screws versus three standard bicortical screws in synthetic models of normal and osteoporotic bone. Methods. Synthetic tubular bone models representing normal bone density and osteoporotic bone density were used. Artificial fracture gaps of 1 cm were created in each specimen before fixation with one of two constructs: 1) two locking screws using a five-hole locking compression plate (LCP) plate; or 2) three non-locking screws with a seven-hole LCP plate across each side of the fracture gap. The stiffness, maximum displacement, mode of failure and number of cycles to failure were recorded under progressive cyclic torsional and eccentric axial loading. Results. Locking plates in normal bone survived 10% fewer cycles to failure during cyclic axial loading, but there was no significant difference in maximum displacement or failure load. Locking plates in osteoporotic bone showed less displacement (p = 0.02), but no significant difference in number of cycles to failure or failure load during cyclic axial loading (p = 0.46 and p = 0.25, respectively). Locking plates in normal bone had lower stiffness and torque during torsion testing (both p = 0.03), but there was no significant difference in rotation (angular displacement) (p = 0.84). Locking plates in osteoporotic bone showed lower torque and rotation (p = 0.008), but there was no significant difference in stiffness during torsion testing (p = 0.69). Conclusions. The mechanical performance of locking plate constructs, using only two screws, is comparable to three non-locking screw constructs in osteoporotic bone. Normal bone loaded with either an axial or torsional moment showed slightly better performance with the non-locking construct


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 963 - 968
1 Nov 1999
Krettek C Stephan C Schandelmaier P Richter M Pape HC Miclau T

Intramedullary nailing of metaphyseal fractures may be associated with deformity as a result of instability after fixation. Our aim was to evaluate the clinical use of Poller screws (blocking screws) as a supplement to stability after fixation with statically locked intramedullary nails of small diameter. We studied, prospectively, 21 tibial fractures, 10 in the proximal third and 11 in the distal third in 20 patients after the insertion of Poller screws over a mean period of 18.5 months (12 to 29). All fractures had united. Healing was evident radiologically at a mean of 5.4 ± 2.1 months (3 to 12) with a mean varus-valgus alignment of −1.0° (−5 to 3) and mean antecurvatum-recurvatum alignment of 1.6° (−6 to 11). The mean loss of reduction between placement of the initial Poller screw and follow-up was 0.5° in the frontal plane and 0.4° in the sagittal plane. There were no complications related to the Poller screw. The clinical outcome, according to the Karström-Olerud score, was not influenced by previous or concomitant injuries in 18 patients and was judged as excellent in three (17%), good in seven (39%), satisfactory in six (33%), fair in one (6%), and poor in one (6%)


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 274 - 282
1 Feb 2022
Grønhaug KML Dybvik E Matre K Östman B Gjertsen J

Aims. The aim of this study was to investigate if there are differences in outcome between sliding hip screws (SHSs) and intramedullary nails (IMNs) with regard to fracture stability. Methods. We assessed data from 17,341 patients with trochanteric or subtrochanteric fractures treated with SHS or IMN in the Norwegian Hip Fracture Register from 2013 to 2019. Primary outcome measures were reoperations for stable fractures (AO Foundation/Orthopaedic Trauma Association (AO/OTA) type A1) and unstable fractures (AO/OTA type A2, A3, and subtrochanteric fractures). Secondary outcome measures were reoperations for A2, A3, and subtrochanteric fractures individually, one-year mortality, quality of life (EuroQol five-dimension three-level index score), pain (visual analogue scale (VAS)), and satisfaction (VAS) for stable and unstable fractures. Hazard rate ratios (HRRs) for reoperation were calculated using Cox regression analysis with adjustments for age, sex, and American Society of Anesthesiologists score. Results. Reoperation rate was lower after surgery with IMN for unstable fractures one year (HRR 0.82, 95% confidence interval (CI) 0.70 to 0.97; p = 0.022) and three years postoperatively (HRR 0.86, 95% CI 0.74 to 0.99; p = 0.036), compared with SHS. For individual fracture types, no clinically significant differences were found. Lower one-year mortality was found for IMN compared with SHS for stable fractures (HRR 0.87; 95% CI 0.78 to 0.96; p = 0.007), and unstable fractures (HRR 0.91, 95% CI 0.84 to 0.98; p = 0.014). Conclusion. This national register-based study indicates a lower reoperation rate for IMN than SHS for unstable trochanteric and subtrochanteric fractures, but not for stable fractures or individual fracture types. The choice of implant may not be decisive to the outcome of treatment for stable trochanteric fractures in terms of reoperation rate. One-year mortality rate for unstable and stable fractures was lower in patients treated with IMN. Cite this article: Bone Joint J 2022;104-B(2):274–282


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 603 - 612
1 Jun 2024
Ahmad A Egeland EH Dybvik EH Gjertsen J Lie SA Fenstad AM Matre K Furnes O

Aims. This study aimed to compare mortality in trochanteric AO/OTA A1 and A2 fractures treated with an intramedullary nail (IMN) or sliding hip screw (SHS). The primary endpoint was 30-day mortality, with secondary endpoints at 0 to 1, 2 to 7, 8 to 30, 90, and 365 days. Methods. We analyzed data from 26,393 patients with trochanteric AO/OTA A1 and A2 fractures treated with IMNs (n = 9,095) or SHSs (n = 17,298) in the Norwegian Hip Fracture Register (January 2008 to December 2020). Exclusions were made for patients aged < 60 years, pathological fractures, pre-2008 operations, contralateral hip fractures, fractures other than trochanteric A1/A2, and treatments other than IMNs or SHSs. Kaplan-Meier and Cox regression analyses adjusted for type of fracture, age, sex, cognitive impairment, American Society of Anesthesiologists (ASA) grade, and time period were conducted, along with calculations for number needed to harm (NNH). Results. In unadjusted analyses, there was no significant difference between IMN and SHS patient survival at 30 days (91.8% vs 91.1%; p = 0.083) or 90 days (85.4% vs 84.5%; p = 0.065), but higher one-year survival for IMNs (74.5% vs 73.3%; p = 0.031) compared with SHSs. After adjustments, no significant difference in 30-day mortality was found (hazard rate ratio (HRR) 0.94 (95% confidence interval (CI) 0.86 to 1.02(; p = 0.146). IMNs exhibited higher mortality at 0 to 1 days (HRR 1.63 (95% CI 1.13 to 2.34); p = 0.009) compared with SHSs, with a NNH of 556, but lower mortality at 8 to 30 days (HRR 0.89 (95% CI 0.80 to 1.00); p = 0.043). No differences were observed in mortality at 2 to 7 days (HRR 0.94 (95% CI 0.79 to 1.11); p = 0.434), 90 days (HRR 0.95 (95% CI 0.89 to 1.02); p = 0.177), or 365 days (HRR 0.97 (95% CI 0.92 to 1.02); p = 0.192). Conclusion. This study found no difference in 30-day mortality between IMNs and SHSs. However, IMNs were associated with a higher mortality at 0 to 1 days and a marginally lower mortality at 8 to 30 days compared with SHSs. The observed differences in mortality were small and should probably not guide choice of treatment. Cite this article: Bone Joint J 2024;106-B(6):603–612


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 775 - 781
1 Apr 2021
Mellema JJ Janssen S Schouten T Haverkamp D van den Bekerom MPJ Ring D Doornberg JN

Aims. This study evaluated variation in the surgical treatment of stable (A1) and unstable (A2) trochanteric hip fractures among an international group of orthopaedic surgeons, and determined the influence of patient, fracture, and surgeon characteristics on choice of implant (intramedullary nailing (IMN) versus sliding hip screw (SHS)). Methods. A total of 128 orthopaedic surgeons in the Science of Variation Group evaluated radiographs of 30 patients with Type A1 and A2 trochanteric hip fractures and indicated their preferred treatment: IMN or SHS. The management of Type A3 (reverse obliquity) trochanteric fractures was not evaluated. Agreement between surgeons was calculated using multirater kappa. Multivariate logistic regression models were used to assess whether patient, fracture, and surgeon characteristics were independently associated with choice of implant. Results. The overall agreement between surgeons on implant choice was fair (kappa = 0.27 (95% confidence interval (CI) 0.25 to 0.28)). Factors associated with preference for IMN included USA compared to Europe or the UK (Europe odds ratio (OR) 0.56 (95% CI 0.47 to 0.67); UK OR 0.16 (95% CI 0.12 to 0.22); p < 0.001); exposure to IMN only during training compared to surgeons that were exposed to both (only IMN during training OR 2.6 (95% CI 2.0 to 3.4); p < 0.001); and A2 compared to A1 fractures (Type A2 OR 10 (95% CI 8.4 to 12); p < 0.001). Conclusion. In an international cohort of orthopaedic surgeons, there was a large variation in implant preference for patients with A1 and A2 trochanteric fractures. This is due to surgeon bias (country of practice and aspects of training). The observation that surgeons favoured the more expensive implant (IMN) in the absence of convincing evidence of its superiority suggests that surgeon de-biasing strategies may be a useful focus for optimizing patient outcomes and promoting value-based healthcare. Cite this article: Bone Joint J 2021;103-B(4):775–781


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 696 - 702
1 May 2016
Theologis AA Burch S Pekmezci M

Aims. We compared the accuracy, operating time and radiation exposure of the introduction of iliosacral screws using O-arm/Stealth Navigation and standard fluoroscopy. Materials and Methods. Iliosacral screws were introduced percutaneously into the first sacral body (S1) of ten human cadavers, four men and six women. The mean age was 77 years (58 to 85). Screws were introduced using a standard technique into the left side of S1 using C-Arm fluoroscopy and then into the right side using O-Arm/Stealth Navigation. The radiation was measured on the surgeon by dosimeters placed under a lead thyroid shield and apron, on a finger, a hat and on the cadavers. Results. There were no neuroforaminal breaches in either group. The set-up time for the O-Arm was significantly longer than for the C-Arm, while total time for placement of the screws was significantly shorter for the O-Arm than for the C-Arm (p = 0.001). The mean absorbed radiation dose during fluoroscopy was 1063 mRad (432.5 mRad to 4150 mRad). No radiation was detected on the surgeon during fluoroscopy, or when he left the room during the use of the O-Arm. The mean radiation detected on the cadavers was significantly higher in the O-Arm group (2710 mRem standard deviation (. sd. ) 1922) than during fluoroscopy (11.9 mRem . sd 14.8). (p < 0.01). Conclusion. O-Arm/Stealth Navigation allows for faster percutaneous placement of iliosacral screws in a radiation-free environment for surgeons, albeit with the same accuracy and significantly more radiation exposure to cadavers, when compared with standard fluoroscopy. Take home message: Placement of iliosacral screws with O-Arm/Stealth Navigation can be performed safely and effectively. Cite this article: Bone Joint J 2016;98-B:696–702


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 83 - 91
1 Jan 2019
Whitehouse MR Berstock JR Kelly MB Gregson CL Judge A Sayers A Chesser TJ

Aims. The aim of this study was to investigate the association between the type of operation used to treat a trochanteric fracture of the hip and 30-day mortality. Patients and Methods. Data on 82 990 patients from the National Hip Fracture Database were analyzed using generalized linear models with incremental case-mix adjustment for patient, non-surgical and surgical characteristics, and socioeconomic factors. Results. The use of short and long intramedullary nails was associated with an increase in 30-day mortality (adjusted odds ratio (OR) 1.125, 95% confidence interval (CI) 1.040 to 1.218; p = 0.004) compared with the use of sliding hip screws (12.5% increase). If this were causative, it would represent 98 excess deaths over the four-year period of the study and one excess death would be caused by treating 112 patients with an intramedullary nail rather than a sliding hip screw. Conclusion. There is a 12.5% increase in the risk of 30-day mortality associated with the use of an intramedullary nail compared with a sliding hip screw in the treatment of a trochanteric fractures of the hip


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1259 - 1264
1 Sep 2011
Wähnert D Windolf M Brianza S Rothstock S Radtke R Brighenti V Schwieger K

We investigated the static and cyclical strength of parallel and angulated locking plate screws using rigid polyurethane foam (0.32 g/cm. 3. ) and bovine cancellous bone blocks. Custom-made stainless steel plates with two conically threaded screw holes with different angulations (parallel, 10° and 20° divergent) and 5 mm self-tapping locking screws underwent pull-out and cyclical pull and bending tests. The bovine cancellous blocks were only subjected to static pull-out testing. We also performed finite element analysis for the static pull-out test of the parallel and 20° configurations. In both the foam model and the bovine cancellous bone we found the significantly highest pull-out force for the parallel constructs. In the finite element analysis there was a 47% more damage in the 20° divergent constructs than in the parallel configuration. Under cyclical loading, the mean number of cycles to failure was significantly higher for the parallel group, followed by the 10° and 20° divergent configurations. In our laboratory setting we clearly showed the biomechanical disadvantage of a diverging locking screw angle under static and cyclical loading


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 652 - 657
1 May 2014
Griffin XL Parsons N Achten J Costa ML

We compared a new fixation system, the Targon Femoral Neck (TFN) hip screw, with the current standard treatment of cannulated screw fixation. This was a single-centre, participant-blinded, randomised controlled trial. Patients aged 65 years and over with either a displaced or undisplaced intracapsular fracture of the hip were eligible. The primary outcome was the risk of revision surgery within one year of fixation. A total of 174 participants were included in the trial. The absolute reduction in risk of revision was of 4.7% (95% CI 14.2 to 22.5) in favour of the TFN hip screw (chi-squared test, p = 0.741), which was less than the pre-specified level of minimum clinically important difference. There were no significant differences in any of the secondary outcome measures. We found no evidence of a clinical difference in the risk of revision surgery between the TFN hip screw and cannulated screw fixation for patients with an intracapsular fracture of the hip. Cite this article: Bone Joint J 2014;96-B:652–7


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 548 - 554
1 Apr 2014
Sun H Luo CF Zhong B Shi HP Zhang CQ Zeng BF

Our aim was to compare polylevolactic acid screws with titanium screws when used for fixation of the distal tibiofibular syndesmosis at mid-term follow-up. A total of 168 patients, with a mean age of 38.5 years (18 to 72) who were randomly allocated to receive either polylevolactic acid (n = 86) or metallic (n = 82) screws were included. The Baird scoring system was used to assess the overall satisfaction and functional recovery post-operatively. The demographic details and characteristics of the injury were similar in the two groups. The mean follow-up was 55.8 months (48 to 66). The Baird scores were similar in the two groups at the final follow-up. Patients in the polylevolactic acid group had a greater mean dorsiflexion (p = 0.011) and plantar-flexion of the injured ankles (p < 0.001). In the same group, 18 patients had a mild and eight patients had a moderate foreign body reaction. In the metallic groups eight had mild and none had a moderate foreign body reaction (p <  0.001). In total, three patients in the polylevolactic acid group and none in the metallic group had heterotopic ossification (p = 0.246). We conclude that both screws provide adequate fixation and functional recovery, but polylevolactic acid screws are associated with a higher incidence of foreign body reactions. Cite this article: Bone Joint J 2014;96-B:548–54


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 76 - 81
1 Jan 2005
Pajarinen J Lindahl J Michelsson O Savolainen V Hirvensalo E

We treated 108 patients with a pertrochanteric femoral fracture using either the dynamic hip screw or the proximal femoral nail in this prospective, randomised series. We compared walking ability before fracture, intra-operative variables and return to their residence. Patients treated with the proximal femoral nail (n = 42) had regained their pre-operative walking ability significantly (p = 0.04) more often by the four-month review than those treated with the dynamic hip screw (n = 41). Peri-operative or immediate post-operative measures of outcome did not differ between the groups, with the exception of operation time. The dynamic hip screw allowed a significantly greater compression of the fracture during the four-month follow-up, but consolidation of the fracture was comparable between the two groups. Two major losses of reduction were observed in each group, resulting in a total of four revision operations. Our results suggest that the use of the proximal femoral nail may allow a faster postoperative restoration of walking ability, when compared with the dynamic hip screw


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1210 - 1215
1 Sep 2017
Parker MJ Cawley S

Aims. To compare the outcomes for trochanteric fractures treated with a sliding hip screw (SHS) or a cephalomedullary nail. Patients and Methods. A total of 400 patients with a trochanteric hip fracture were randomised to receive a SHS or a cephalomedullary nail (Targon PFT). All surviving patients were followed up to one year from injury. Functional outcome was assessed by a research nurse blinded to the implant used. Results. Recovery of mobility, as assessed by a mobility scale, was superior for those treated with the intramedullary nail compared with the SHS at eight weeks, three and nine months (p-values between 0.01 and 0.04), the difference at six and 12 months was not statistically significant (p = 0.15 and p = 0.18 respectively). The mean difference was around 0.4 points (0.3 to 0.5) on a nine point scale. Surgical time for the nail was four minutes less than that for the SHS (p < 0.001). Fracture healing complications were similar for the two groups. There were no statistically significant differences between implants for any other recorded outcomes including the need for post-operative blood transfusion, wound healing complications, general medical complications, hospital stay or mortality. Conclusion. This study confirms the findings of a previous study that both methods of treatment produce similar results, although intramedullary fixation does result in marginally improved regain of mobility in comparison with the SHS. Cite this article: Bone Joint J 2017;99-B:1210–15


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1699 - 1705
1 Dec 2014
Boyle MJ Gao R Frampton CMA Coleman B

Our aim was to compare the one-year post-operative outcomes following retention or removal of syndesmotic screws in adult patients with a fracture of the ankle that was treated surgically. A total of 51 patients (35 males, 16 females), with a mean age of 33.5 years (16 to 62), undergoing fibular osteosynthesis and syndesmotic screw fixation, were randomly allocated to retention of the syndesmotic screw or removal at three months post-operatively. The two groups were comparable at baseline. . One year post-operatively, there was no significant difference in the mean Olerud–Molander ankle score (82.4 retention vs 86.7 removal, p = 0.367), the mean American Orthopedic Foot and Ankle Society ankle-hindfoot score (88.6 vs 90.1, p = 0.688), the mean American Academy of Orthopedic Surgeons foot and ankle score (96.3 vs 94.0, p = 0.250), the mean visual analogue pain score (1.0 vs 0.7, p = 0.237), the mean active dorsiflexion (10.2° vs 13.0°, p = 0.194) and plantar flexion (33.6° vs 31.3°, p = 0.503) of the ankle, or the mean radiological tibiofibular clear space (5.0 mm vs 5.3 mm, p = 0.276) between the two groups. A total of 19 patients (76%) in the retention group had a loose and/or broken screw one year post-operatively. . We conclude that removal of a syndesmotic screw produces no significant functional, clinical or radiological benefit in adult patients who are treated surgically for a fracture of the ankle. Cite this article: Bone Joint J 2014;96-B:1699–1705


We evaluated the outcome of treatment of nonunion of an intracapsular fracture of the femoral neck in young patients using two cannulated screws and a vascularised bone graft. A total of 32 patients (15 women and 17 men, with a mean age of 36.5 years; 20 to 50) with failed internal fixation of an intracapsular fracture were included in the study. Following removal of the primary fixation, two cannulated compression screws were inserted with a vascularised iliac crest bone graft based on the ascending branch of the lateral femoral circumflex artery. At a mean follow-up of 6.8 years (4 to 10), union was achieved in 27 hips (84%). A total of five patients with a mean age of 40.5 years (35 to 50) had a persistent nonunion and underwent total hip arthroplasty as also did two patients whose fracture united but who developed osteonecrosis of the femoral head two years post-operatively. Statistical analysis showed that younger patients achieved earlier and more reliable union (p < 0.001). The functional outcome, as assessed by the Harris Hip score, was better in patients aged < 45 years compared with those aged > 45 years (p < 0.001). . These findings suggest that further fixation using two cannulated compression screws and a vascularised iliac crest bone graft is an effective salvage treatment in patients aged <  45 years, in whom osteosynthesis of a displaced intracapsular fractures of the femoral neck has failed. Cite this article: Bone Joint J 2015; 97-B:988–91


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 398 - 404
1 Mar 2015
Fang C Lau TW Wong TM Lee HL Leung F

The spiral blade modification of the Dynamic Hip Screw (DHS) was designed for superior biomechanical fixation in the osteoporotic femoral head. Our objective was to compare clinical outcomes and in particular the incidence of loss of fixation. . In a series of 197 consecutive patients over the age of 50 years treated with DHS-blades (blades) and 242 patients treated with conventional DHS (screw) for AO/OTA 31.A1 or A2 intertrochanteric fractures were identified from a prospectively compiled database in a level 1 trauma centre. Using propensity score matching, two groups comprising 177 matched patients were compiled and radiological and clinical outcomes compared. In each group there were 66 males and 111 females. Mean age was 83.6 (54 to 100) for the conventional DHS group and 83.8 (52 to 101) for the blade group. Loss of fixation occurred in two blades and 13 DHSs. None of the blades had observable migration while nine DHSs had gross migration within the femoral head before the fracture healed. There were two versus four implant cut-outs respectively and one side plate pull-out in the DHS group. There was no significant difference in mortality and eventual walking ability between the groups. Multiple logistic regression suggested that poor reduction (odds ratio (OR) 11.49, 95% confidence intervals (CI) 1.45 to 90.9, p = 0.021) and fixation by DHS (OR 15.85, 95%CI 2.50 to 100.3, p = 0.003) were independent predictors of loss of fixation. . The spiral blade design may decrease the risk of implant migration in the femoral head but does not reduce the incidence of cut-out and reoperation. Reduction of the fracture is of paramount importance since poor reduction was an independent predictor for loss of fixation regardless of the implant being used. Cite this article: Bone Joint J 2015;97-B:398–404


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 66 - 71
1 Jan 2008
McQueen MM Gelbke MK Wakefield A Will EM Gaebler C

We randomly allocated 60 consecutive patients with fractures of the waist of the scaphoid to percutaneous fixation with a cannulated Acutrak screw or immobilisation in a cast. The range of movement, the grip and pinch strength, the modified Green/O’Brien functional score, return to work and sports, and radiological evidence of union were evaluated at each follow-up visit. Patients were followed sequentially for one year. Those undergoing percutaneous screw fixation showed a quicker time to union (9.2 weeks vs 13.9 weeks, p < 0.001) than those treated with a cast. There was a trend towards a higher rate of nonunion in the non-operative group, although this was not statistically significant. Patients treated by operation had a more rapid return of function and to sport and full work compared with those managed conservatively. There was a very low complication rate. We recommend that all active patients should be offered percutaneous stabilisation for fractures of the waist of the scaphoid


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1495 - 1497
1 Nov 2007
Jones BG Mehin R Young D

Intramedullary tibial nailing was performed in ten paired cadavers and the insertion of a medial-to-lateral proximal oblique locking screw was simulated in each specimen. Anatomical dissection was undertaken to determine the relationship of the common peroneal nerve to the cross-screw. The common peroneal nerve was contacted directly in four tibiae and the cross-screw was a mean of 2.6 mm (1.0 to 10.7) away from the nerve in the remaining 16. Iatrogenic injury to the common peroneal nerve by medial-to-lateral proximal oblique locking screws is therefore a significant risk during tibial nailing


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1347 - 1350
1 Oct 2006
Karn NK Singh GK Kumar P Shrestha B Singh MP Gowda MJ

We conducted a randomised controlled trial to compare external fixation of trochanteric fractures of the femur with the more costly option of the sliding hip screw. Patients in both groups were matched for age (mean 67 years, 50 to 100) and gender. We excluded all pathological fractures, patients presenting at more than one week, fractures with subtrochanteric extension or reverse obliquity, multiple fractures or any bone and joint disease interfering with rehabilitation. The interval between injury and operation, the duration of surgery, the amount of blood loss, the length of hospital stay and the cost of treatment were all significantly higher in the sliding hip screw group (p < 0.05). The time to union, range of movement, mean Harris hip scores and Western Ontario and McMaster University knee scores were comparable at six months. The number of patients showing shortening or malrotation was too small to show a significant difference between the groups. Pin-track infection occurred in 18 patients (60%) treated with external fixation, whereas there was a single case of wound infection (3.3%) in the sliding hip screw group


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1406 - 1409
1 Oct 2013
Wähnert D Lange JH Schulze M Gehweiler D Kösters C Raschke MJ

The augmentation of fixation with bone cement is increasingly being used in the treatment of severe osteoporotic fractures. We investigated the influence of bone quality on the mechanics of augmentation of plate fixation in a distal femoral fracture model (AO 33 A3 type). Eight osteoporotic and eight non-osteoporotic femoral models were randomly assigned to either an augmented or a non-augmented group. Fixation was performed using a locking compression plate. In the augmented group additionally 1 ml of bone cement was injected into the screw hole before insertion of the screw. Biomechanical testing was performed in axial sinusoidal loading. Augmentation significantly reduced the cut-out distance in the osteoporotic models by about 67% (non-augmented mean 0.30 mm (. sd. 0.08) vs augmented 0.13 mm (. sd. 0.06); p = 0.017). There was no statistical reduction in this distance following augmentation in the non-osteoporotic models (non-augmented mean 0.15 mm (. sd. 0.02) vs augmented 0.15 mm (. sd. 0.07); p = 0.915). In the osteoporotic models, augmentation significantly increased stability (p = 0.017). Cite this article: Bone Joint J 2013;95-B:1406–9


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 705 - 710
1 May 2015
Ozmeric A Yucens M Gultaç E Açar HI Aydogan NH Gül D Alemdaroglu KB

We hypothesised that the anterior and posterior walls of the body of the first sacral vertebra could be visualised with two different angles of inlet view, owing to the conical shape of the sacrum. Six dry male cadavers with complete pelvic rings and eight dry sacrums with K-wires were used to study the effect of canting (angling the C-arm) the fluoroscope towards the head in 5° increments from 10° to 55°. Fluoroscopic images were taken in each position. Anterior and posterior angles of inclination were measured between the upper sacrum and the vertical line on the lateral view. Three authors separately selected the clearest image for overlapping anterior cortices and the upper sacral canal in the cadaveric models. The dry bone and K-wire models were scored by the authors, being sure to check whether the K-wire was in or out. In the dry bone models the mean score of the relevant inlet position of the anterior or posterior inclination was 8.875 (standard deviation (. sd. ) 0.35), compared with the inlet position of the opposite inclination of –5.75 (. sd. 4.59). We found that two different inlet views should be used separately to evaluate the borders of the body of the sacrum using anterior and posterior inclination angles of the sacrum, during placement of iliosacral screws. Cite this article: Bone Joint J 2015;97-B:705–10


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1520 - 1523
1 Nov 2005
Attias N Lindsey RW Starr AJ Borer D Bridges K Hipp JA

We created virtual three-dimensional reconstruction models from computed tomography scans obtained from patients with acetabular fractures. Virtual cylindrical implants were placed intraosseously in the anterior column, the posterior column and across the dome of the acetabulum. The maximum diameter which was entirely contained within the bone was determined for each position of the screw. In the same model, the cross-sectional diameters of the columns were measured and compared to the maximum diameter of the corresponding virtual implant. We found that the mean maximum diameter of virtual implant accommodated by the anterior columns was 6.4 mm and that the smallest diameter of the columns was larger than the maximum diameter of the equivalent virtual implant. This study suggests that the size of the screw used for percutaneous fixation of acetabular fractures should not be based solely on the measurement of cross-sectional diameter and that virtual three-dimensional reconstructions might be useful in pre-operative planning


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 411 - 418
1 Apr 2003
Ziran BH Smith WR Towers J Morgan SJ

Various techniques have been used for the fixation of the posterior pelvis, each with disadvantages specific to the technique. In this study, a new protocol involving the placement of posterior pelvic screws in the CT suite is described and evaluated. A total of 66 patients with unstable pelvic ring injuries was stabilised under local anaesthesia with sedation. The mean length of time for the procedure was 26 minutes per screw. There were no technical difficulties or misplaced screws and no cases of infection or nonunion. All patients stated that they would choose to have the CT scan procedure again rather than a procedure requiring general anaesthesia. The charges for the procedure were approximately £1840 ($2800) per operation. CT-guided placement of iliosacral screws is a safe, feasible, and cost-effective alternative to radiologically-guided placement in the operating theatre in selected patients


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 114 - 121
1 Jan 2014
Pekmezci M McDonald E Buckley J Kandemir U

We investigated a new intramedullary locking nail that allows the distal interlocking screws to be locked to the nail. We compared fixation using this new implant with fixation using either a conventional nail or a locking plate in a laboratory simulation of an osteoporotic fracture of the distal femur. A total of 15 human cadaver femora were used to simulate an AO 33-A3 fracture pattern. Paired specimens compared fixation using either a locking or non-locking retrograde nail, and using either a locking retrograde nail or a locking plate. The constructs underwent cyclical loading to simulate single-leg stance up to 125 000 cycles. Axial and torsional stiffness and displacement, cycles to failure and modes of failure were recorded for each specimen. When compared with locking plate constructs, locking nail constructs had significantly longer mean fatigue life (75 800 cycles (. sd. 33 900) vs 12 800 cycles (. sd. 6100); p = 0.007) and mean axial stiffness (220 N/mm (. sd. 80) vs 70 N/mm (. sd. 18); p = 0.005), but lower mean torsional stiffness (2.5 Nm/° (. sd. 0.9) vs 5.1 Nm/° (. sd. 1.5); p = 0.008). In addition, in the nail group the mode of failure was either cut-out of the distal screws or breakage of nails, and in the locking plate group breakage of the plate was always the mode of failure. Locking nail constructs had significantly longer mean fatigue life than non-locking nail constructs (78 900 cycles (. sd. 25 600) vs 52 400 cycles (. sd. 22 500); p = 0.04). The new locking retrograde femoral nail showed better stiffness and fatigue life than locking plates, and superior fatigue life to non-locking nails, which may be advantageous in elderly patients. Cite this article: Bone Joint J 2014;96-B:114–21


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1073 - 1078
1 Aug 2008
Little NJ Verma V Fernando C Elliott DS Khaleel A

We compared the outcome of patients treated for an intertrochanteric fracture of the femoral neck with a locked, long intramedullary nail with those treated with a dynamic hip screw (DHS) in a prospective randomised study. Each patient who presented with an extra-capsular hip fracture was randomised to operative stabilisation with either a long intramedullary Holland nail or a DHS. We treated 92 patients with a Holland nail and 98 with a DHS. Pre-operative variables included the Mini Mental test score, patient mobility, fracture pattern and American Society of Anesthesiologists grading. Peri-operative variables were anaesthetic time, operating time, radiation time and blood loss. Post-operative variables were time to mobilising with a frame, wound infection, time to discharge, time to fracture union, and mortality. We found no significant difference in the pre-operative variables. The mean anaesthetic and operation times were shorter in the DHS group than in the Holland nail group (29.7 vs 40.4 minutes, p < 0.001; and 40.3 vs 54 minutes, p < 0.001, respectively). There was an increased mean blood loss within the DHS group versus the Holland nail group (160 ml vs 78 ml, respectively, p < 0.001). The mean time to mobilisation with a frame was shorter in the Holland nail group (DHS 4.3 days, Holland nail 3.6 days, p = 0.012). More patients needed a post-operative blood transfusion in the DHS group (23 vs seven, p = 0.003) and the mean radiation time was shorter in this group (DHS 0.9 minutes vs Holland nail 1.56 minutes, p < 0.001). The screw of the DHS cut out in two patients, one of whom underwent revision to a Holland nail. There were no revisions in the Holland nail group. All fractures in both groups were united when followed up after one year. We conclude that the DHS can be implanted more quickly and with less exposure to radiation than the Holland nail. However, the resultant blood loss and need for transfusion is greater. The Holland nail allows patients to mobilise faster and to a greater extent. We have therefore adopted the Holland nail as our preferred method of treating intertrochanteric fractures of the hip


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 241 - 248
1 Feb 2012
Firoozabadi R McDonald E Nguyen T Buckley JM Kandemir U

Filling the empty holes in peri-articular locking plates may improve the fatigue strength of the fixation. The purpose of this in vitro study was to investigate the effect of plugging the unused holes on the fatigue life of peri-articular distal femoral plates used to fix a comminuted supracondylar fracture model. A locking/compression plate was applied to 33 synthetic femurs and then a 6 cm metaphyseal defect was created (AO Type 33-A3). The specimens were then divided into three groups: unplugged, plugged with locking screw only and fully plugged holes. They were then tested using a stepwise or run-out fatigue protocol, each applying cyclic physiological multiaxial loads. All specimens in the stepwise group failed at the 770 N load level. The mean number of cycles to failure for the stepwise specimen was 25 500 cycles (. sd. 1500), 28 800 cycles (. sd.  6300), and 26 400 cycles (. sd. 2300) cycles for the unplugged, screw only and fully plugged configurations, respectively (p = 0.16). The mean number of cycles to failure for the run-out specimens was 42 800 cycles (. sd. 10 700), 36 000 cycles (. sd. 7200), and 36 600 cycles (. sd.  10 000) for the unplugged, screw only and fully plugged configurations, respectively (p = 0.50). There were also no differences in axial or torsional stiffness between the constructs. The failures were through the screw holes at the level of comminution. In conclusion, filling the empty combination locking/compression holes in peri-articular distal femur locking plates at the level of supracondylar comminution does not increase the fatigue life of the fixation in a comminuted supracondylar femoral fracture model (AO 33-A3) with a 6 cm gap


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 23 - 29
1 Jan 2002
Vossinakis IC Badras LS

In a prospective, randomised study we have compared the pertrochanteric external fixator (PF) with the sliding hip screw (SHS) in 100 consecutive patients who were allocated randomly to the two methods of treatment. Details of the patients and the patterns of fracture were similar in both groups. Follow-up was for six months. Use of the PF was associated with significantly less blood loss, a shorter operating time, reduced postoperative pain, shorter hospitalisation (p < 0.001), earlier mobilisation (p < 0.001) and a reduced rate of mechanical complications (p < 0.01). Superficial infection was significantly more common with the PF (p < 0.01), but without long-term adverse consequences. There were no differences in the healing of the fracture, mortality or final functional outcome. Our results indicate that the external fixator is an effective and safe device for treating pertrochanteric fractures and should be considered as a useful alternative to conventional fixation with the sliding hip screw


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 391 - 397
1 Mar 2012
Parker MJ Bowers TR Pryor GA

In a randomised trial involving 598 patients with 600 trochanteric fractures of the hip, the fractures were treated with either a sliding hip screw (n = 300) or a Targon PF intramedullary nail (n = 300). The mean age of the patients was 82 years (26 to 104). All surviving patients were reviewed at one year with functional outcome assessed by a research nurse blinded to the treatment used. The intramedullary nail was found to have a slightly increased mean operative time (46 minutes (. sd. 12.3) versus 49 minutes (. sd. 12.7), p < 0.001) and an increased mean radiological screening time (0.3 minutes (. sd. 0.2) versus 0.5 minutes (. sd. 0.3), p <  0.001). Operative difficulties were more common with the intramedullary nail. There was no statistically significant difference between implants for wound healing complications (p = 1), or need for post-operative blood transfusion (p = 1), and medical complications were similarly distributed in both groups. There was a tendency to fewer revisions of fixation or conversion to an arthroplasty in the nail group, although the difference was not statistically significant (nine versus three cases, p = 0.14). The extent of shortening, loss of hip flexion, mortality and degree of residual pain were similar in both groups. The recovery of mobility was superior for those treated with the intramedullary nails (p = 0.01 at one year from injury). In summary, both implants produced comparable results but there was a tendency to better return of mobility for those treated with the intramedullary nail


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 74 - 77
1 Jan 2003
Simonis RB Nuñez VA Khaleel A

Between 1993 and 2000 we treated 14 patients with nonunion of fractures of the distal humerus; 11 had already had previous fixation which had failed. The mean time to surgery was 21 months after injury. All the fractures were very low which made it difficult to obtain a firm hold of the small distal fragment. The problem of fixation was addressed by inserting a Coventry infant hip screw into the humeral condyles. The screw has a thread of wide diameter which gives excellent purchase on the small distal fragment. The condyles can then be compressed on to the humeral shaft using a 4.5 mm narrow tibial dynamic plate. Of these 14 difficult cases of nonunion, 12 progressed to union


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 418 - 421
1 May 1997
Inoue G Shionoya K

We describe a semi-closed method of Herbert screw fixation for acute fractures of the scaphoid. All 40 patients treated achieved solid union with satisfactory wrist function. This technique gave a significantly shorter time to union and allowed an earlier return to manual labour compared with conservative treatment. There were no complications. Semi-closed insertion requires considerable skill, but produces consistently satisfactory results after minimal exposure of the scaphoid


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1210 - 1217
1 Sep 2007
Peyser A Weil YA Brocke L Sela Y Mosheiff R Mattan Y Manor O Liebergall M

Limited access surgery is thought to reduce post-operative morbidity and provide faster recovery of function. The percutaneous compression plate (PCCP) is a recently introduced device for the fixation of intertrochanteric fractures with minimal exposure. It has several potential mechanical advantages over the conventional compression hip screw (CHS). Our aim in this prospective, randomised, controlled study was to compare the outcome of patients operated on using these two devices. We randomised 104 patients with intertrochanteric fractures (AO/OTA 31.A1–A2) to surgical treatment with either the PCCP or CHS and followed them for one year postoperatively. The mean operating blood loss was 161.0 ml (8 to 450) in the PCCP group and 374.0 ml (11 to 980) in the CHS group (Student’s t-test, p < 0.0001). The pain score and ability to bear weight were significantly better in the PCCP group at six weeks post-operatively. Analysis of the radiographs in a proportion of the patients revealed a reduced amount of medial displacement in the PCCP group (two patients, 4%) compared with the CHS group (10 patients, 18.9%); Fisher’s exact test, p < 0.02. The PCCP device was associated with reduced intra-operative blood loss, less postoperative pain and a reduced incidence of collapse of the fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 19 - 22
1 Jan 2002
Kosygan KP Mohan R Newman RJ

We performed a randomised, prospective trial in 111 patients with intertrochanteric fractures of the hip comparing the use of the Gotfried percutaneous compression plate (PCCP) with that of the classic hip screw (CHS). Blood loss and transfusion requirement were less in the PCCP group but the operating time was significantly longer. The complication rate after operation was similar in both groups, and at a minimum follow-up of six months there was no difference in the rates of fracture healing or implant failure. The PCCP gives results which are similar to those obtained with a conventional device. Its suggested advantages seem to be theoretical rather than practical and, being a fixed-angle implant, it is not universally applicable


Bone & Joint Open
Vol. 5, Issue 6 | Pages 457 - 463
2 Jun 2024
Coviello M Abate A Maccagnano G Ippolito F Nappi V Abbaticchio AM Caiaffa E Caiaffa V

Aims. Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of TAD as a risk factor in a cephalic double-screw nail. Methods. A retrospective study was conducted on 112 patients treated for intertrochanteric femur fracture with a double proximal screw nail (Endovis BA2; EBA2) from January to September 2021. The analyzed variables were age, sex, BMI, comorbidities, fracture type, side, time of surgery, quality of reduction, pre-existing therapy with bisphosphonate for osteoporosis, screw placement in two different views, and TAD. The last follow-up was at 12 months. Logistic regression was used to study the potential factors of screw cut-out, and receiver operating characteristic curve to identify the threshold value. Results. A total of 98 of the 112 patients met the inclusion criteria. Overall, 65 patients were female (66.3%), the mean age was 83.23 years (SD 7.07), and the mean follow-up was 378 days (SD 36). Cut-out was observed in five patients (5.10%). The variables identified by univariate analysis with p < 0.05 were included in the multivariate logistic regression model were screw placement and TAD. The TAD was significant with an odds ratio (OR) 5.03 (p = 0.012) as the screw placement with an OR 4.35 (p = 0.043) in the anteroposterior view, and OR 10.61 (p = 0.037) in the lateral view. The TAD threshold value identified was 29.50 mm. Conclusion. Our study confirmed the risk factors for cut-out in the double-screw nail are comparable to those in the single screw. We found a TAD value of 29.50 mm to be associated with a risk of cut-out in double-screw nails, when good fracture reduction is granted. This value is higher than the one reported with single-screw nails. Therefore, we suggest the role of TAD should be reconsidered in well-reduced fractures treated with double-screw intramedullary nail. Cite this article: Bone Jt Open 2024;5(6):457–463


Bone & Joint Open
Vol. 5, Issue 1 | Pages 46 - 52
19 Jan 2024
Assink N ten Duis K de Vries JPM Witjes MJH Kraeima J Doornberg JN IJpma FFA

Aims. Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery. Methods. A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group. Results. A total of 15 patients were treated with 3D surgical planning in which 83 screws were placed by using drilling guides. The median deviation of the achieved screw trajectory from the planned trajectory was 3.4° (interquartile range (IQR) 2.5 to 5.4) and the difference in entry points (i.e. plate position) was 3.0 mm (IQR 2.0 to 5.5) compared to the 3D preoperative planning. The length of 72 screws (86.7%) were according to the planning. Compared to the historical cohort, 3D-guided surgery showed an improved surgical reduction in terms of median gap (3.1 vs 4.7 mm; p = 0.126) and step-off (2.9 vs 4.0 mm; p = 0.026). Conclusion. The use of 3D surgical planning including drilling guides was feasible, and facilitated accurate screw directions, screw lengths, and plate positioning. Moreover, the personalized approach improved fracture reduction as compared to a historical cohort. Cite this article: Bone Jt Open 2024;5(1):46–52


Bone & Joint Open
Vol. 5, Issue 1 | Pages 37 - 45
19 Jan 2024
Alm CE Karlsten A Madsen JE Nordsletten L Brattgjerd JE Pripp AH Frihagen F Röhrl SM

Aims. Despite limited clinical scientific backing, an additional trochanteric stabilizing plate (TSP) has been advocated when treating unstable trochanteric fractures with a sliding hip screw (SHS). We aimed to explore whether the TSP would result in less post operative fracture motion, compared to SHS alone. Methods. Overall, 31 patients with AO/OTA 31-A2 trochanteric fractures were randomized to either a SHS alone or a SHS with an additional TSP. To compare postoperative fracture motion, radiostereometric analysis (RSA) was performed before and after weightbearing, and then at four, eight, 12, 26, and 52 weeks. With the “after weightbearing” images as baseline, we calculated translations and rotations, including shortening and medialization of the femoral shaft. Results. Similar migration profiles were observed in all directions during the course of healing. At one year, eight patients in the SHS group and 12 patients in the TSP group were available for analysis, finding a clinically non-relevant, and statistically non-significant, difference in total translation of 1 mm (95% confidence interval -4.7 to 2.9) in favour of the TSP group. In line with the migration data, no significant differences in clinical outcomes were found. Conclusion. The TSP did not influence the course of healing or postoperative fracture motion compared to SHS alone. Based on our results, routine use of the TSP in AO/OTA 31-A2 trochanteric fractures cannot be recommended. The TSP has been shown, in biomechanical studies, to increase stability in sliding hip screw constructs in both unstable and intermediate stable trochanteric fractures, but the clinical evidence is limited. This study showed no advantage of the TSP in unstable (AO 31-A2) fractures in elderly patients when fracture movement was evaluated with radiostereometric analysis. Cite this article: Bone Jt Open 2024;5(1):37–45


Bone & Joint Open
Vol. 4, Issue 8 | Pages 584 - 593
15 Aug 2023
Sainio H Rämö L Reito A Silvasti-Lundell M Lindahl J

Aims. Several previously identified patient-, injury-, and treatment-related factors are associated with the development of nonunion in distal femur fractures. However, the predictive value of these factors is not well defined. We aimed to assess the predictive ability of previously identified risk factors in the development of nonunion leading to secondary surgery in distal femur fractures. Methods. We conducted a retrospective cohort study of adult patients with traumatic distal femur fracture treated with lateral locking plate between 2009 and 2018. The patients who underwent secondary surgery due to fracture healing problem or plate failure were considered having nonunion. Background knowledge of risk factors of distal femur fracture nonunion based on previous literature was used to form an initial set of variables. A logistic regression model was used with previously identified patient- and injury-related variables (age, sex, BMI, diabetes, smoking, periprosthetic fracture, open fracture, trauma energy, fracture zone length, fracture comminution, medial side comminution) in the first analysis and with treatment-related variables (different surgeon-controlled factors, e.g. plate length, screw placement, and proximal fixation) in the second analysis to predict the nonunion leading to secondary surgery in distal femur fractures. Results. We were able to include 299 fractures in 291 patients. Altogether, 31/299 fractures (10%) developed nonunion. In the first analysis, pseudo-R. 2. was 0.27 and area under the receiver operating characteristic curve (AUC) was 0.81. BMI was the most important variable in the prediction. In the second analysis, pseudo-R. 2. was 0.06 and AUC was 0.67. Plate length was the most important variable in the prediction. Conclusion. The model including patient- and injury-related factors had moderate fit and predictive ability in the prediction of distal femur fracture nonunion leading to secondary surgery. BMI was the most important variable in prediction of nonunion. Surgeon-controlled factors had a minor role in prediction of nonunion. Cite this article: Bone Jt Open 2023;4(8):584–593


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 387 - 393
1 Apr 2024
Dean BJF Riley N Little C Sheehan W Gidwani S Brewster M Dhiman P Costa ML

Aims. There is a lack of published evidence relating to the rate of nonunion seen in occult scaphoid fractures, diagnosed only after MRI. This study reports the rate of delayed union and nonunion in a cohort of patients with MRI-detected acute scaphoid fractures. Methods. This multicentre cohort study at eight centres in the UK included all patients with an acute scaphoid fracture diagnosed on MRI having presented acutely following wrist trauma with normal radiographs. Data were gathered retrospectively for a minimum of 12 months at each centre. The primary outcome measures were the rate of acute surgery, delayed union, and nonunion. Results. A total of 1,989 patients underwent acute MRI for a suspected scaphoid fracture during the study period, of which 256 patients (12.9%) were diagnosed with a previously occult scaphoid fracture. Of the patients with scaphoid fractures, six underwent early surgical fixation (2.3%) and there was a total of 16 cases of delayed or nonunion (6.3%) in the remaining 250 patients treated with cast immobilization. Of the nine nonunions (3.5%), seven underwent surgery (2.7%), one opted for non-surgical treatment, and one failed to attend follow-up. Of the seven delayed unions (2.7%), one (0.4%) was treated with surgery at two months, one (0.4%) did not attend further follow-up, and the remaining five fractures (1.9%) healed after further cast immobilization. All fractures treated with surgery had united at follow-up. There was one complication of surgery (prominent screw requiring removal). Conclusion. MRI-detected scaphoid fractures are not universally benign, with delayed or nonunion of scaphoid fractures diagnosed only after MRI seen in over 6% despite appropriate initial immobilization, with most of these patients with nonunion requiring surgery to achieve union. This study adds weight to the evidence base supporting the use of early MRI for these patients. Cite this article: Bone Joint J 2024;106-B(4):387–393


Bone & Joint Open
Vol. 4, Issue 8 | Pages 602 - 611
21 Aug 2023
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims. To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture. Methods. This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty). Results. Eight female (29%) and 20 male trainees (71%), mean age 29.4 years, performed 317 DHS operations and 243 hemiarthroplasties during ten months of follow-up. Primary analysis was a random effect model with surgeon-level fixed effects of patient condition, patient age, and surgeon experience, with a random intercept for surgeon. Under the intention-to-treat principle, for hemiarthroplasty there was better implant position in favour of cadaveric training, measured by leg length discrepancy ≤ 10 mm (odds ratio (OR) 4.08 (95% confidence interval (CI) 1.17 to 14.22); p = 0.027). There were significantly fewer postoperative blood transfusions required in patients undergoing hemiarthroplasty by cadaveric-trained compared to standard-trained surgeons (OR 6.00 (95% CI 1.83 to 19.69); p = 0.003). For DHS, there was no significant between-group difference in implant position as measured by tip-apex distance ≤ 25 mm (OR 6.47 (95% CI 0.97 to 43.05); p = 0.053). No between-group differences were observed for any secondary clinical outcomes. Conclusion. Trainees randomized to additional cadaveric training performed hip fracture fixation with better implant positioning and fewer postoperative blood transfusions in hemiarthroplasty. This effect, which was previously unknown, may be a consequence of the intervention. Further study is required. Cite this article: Bone Jt Open 2023;4(8):602–611


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1182 - 1189
1 Oct 2024
Nisar S Lamb J Johansen A West R Pandit H

Aims. To determine if patient ethnicity among patients with a hip fracture influences the type of fracture, surgical care, and outcome. Methods. This was an observational cohort study using a linked dataset combining data from the National Hip Fracture Database and Hospital Episode Statistics in England and Wales. Patients’ odds of dying at one year were modelled using logistic regression with adjustment for ethnicity and clinically relevant covariates. Results. A total of 563,640 patients were included between 1 April 2011 and 1 October 2020. Of these, 476,469 (85%) had a coded ethnicity for analysis. Non-white patients tended to be younger (mean 81.2 vs 83.0 years), and were more commonly male (34.9% vs 28.5%; p < 0.001). They were less likely to be admitted from institutional care (12.9% vs 21.8%; p < 0.001), to have normal cognition (53.3% vs 62.0%; p < 0.001), and to be free of comorbidities (22.0% vs 26.8%; p < 0.001), but were more likely to be from the most deprived areas (29.4% vs 17.3%; p < 0.001). Non-white patients were more likely to experience delay to surgery for medical reasons (14.8% vs 12.7%; p < 0.001), more likely to be treated with an intramedullary nail or a sliding hip screw (52.5% vs 45.1%; p < 0.001), and less likely to be mobilized by the day after surgery (74.3% vs 79.0%; p < 0.001). Mortality was higher among non-white inpatients (9.2% vs 8.4% for white), but was lower at one year after hip fracture (26.6% vs 30.3%). Conclusion. Our study identified serious problems with the quality of NHS ethnicity data. Despite this, we have shown that there is complex variation in case-mix and hip fracture morphology between ethnic groups. We have also identified variations in care received between ethnic groups, and that disparities in healthcare may contribute to poorer outcome. Inpatient mortality is higher in non-white patients, although this finding reverses after discharge, and one-year mortality is lower. Patients from ethnic minority backgrounds experience disparities in healthcare, however at one year postoperatively non-white patients have a statistically significant lower mortality after controlling for relevant clinical covariates. Cite this article: Bone Joint J 2024;106-B(10):1182–1189


Bone & Joint Open
Vol. 3, Issue 10 | Pages 741 - 745
1 Oct 2022
Baldock TE Dixon JR Koubaesh C Johansen A Eardley WGP

Aims. Patients with A1 and A2 trochanteric hip fractures represent a substantial proportion of trauma caseload, and national guidelines recommend that sliding hip screws (SHS) should be used for these injuries. Despite this, intramedullary nails (IMNs) are routinely implanted in many hospitals, at extra cost and with unproven patient outcome benefit. We have used data from the National Hip Fracture Database (NHFD) to examine the use of SHS and IMN for A1 and A2 hip fractures at a national level, and to define the cost implications of management decisions that run counter to national guidelines. Methods. We used the NHFD to identify all operations for fixation of trochanteric fractures in England and Wales between 1 January 2021 and 31 December 2021. A uniform price band from each of three hip fracture implant manufacturers was used to set cost implications alongside variation in implant use. Results. We identified 18,156 A1 and A2 trochanteric hip fractures in 162 centres. Of these, 13,483 (74.3%) underwent SHS fixation, 2,352 (13.0%) were managed with short IMN, and 2,321 (12.8%) were managed with long IMN. Total cost of IMN added up to £1.89 million in 2021, and the clinical justification for this is unclear since rates of IMN use varied from 0% to 97% in different centres. Conclusion. Most trochanteric hip fractures are managed with SHS, in keeping with national guidelines. There is considerable variance between hospitals for implant choice, despite the lack of evidence for clinical benefit and cost-effectiveness of more expensive nailing systems. This suggests either a lack of awareness of national guidelines or a choice not to follow them. We encourage provider units to reassess their practice if outwith the national norm. Funding bodies should examine implant use closely in this population to prevent resource waste at a time of considerable health austerity. Cite this article: Bone Jt Open 2022;3(10):741–745


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1266 - 1272
1 Nov 2022
Farrow L Brasnic L Martin C Ward K Adam K Hall AJ Clement ND MacLullich AMJ

Aims. The aim of this study was to examine perioperative blood transfusion practice, and associations with clinical outcomes, in a national cohort of hip fracture patients. Methods. A retrospective cohort study was undertaken using linked data from the Scottish Hip Fracture Audit and the Scottish National Blood Transfusion Service between May 2016 and December 2020. All patients aged ≥ 50 years admitted to a Scottish hospital with a hip fracture were included. Assessment of the factors independently associated with red blood cell transfusion (RBCT) during admission was performed, alongside determination of the association between RBCT and hip fracture outcomes. Results. A total of 23,266 individual patient records from 18 hospitals were included. The overall rate of blood transfusion during admission was 28.7% (n = 6,685). There was inter-hospital variation in transfusion rate, ranging from 16.6% to 37.4%. Independent perioperative factors significantly associated with RBCT included older age (90 to 94 years, odds ratio (OR) 3.04 (95% confidence interval (CI) 2.28 to 4.04); p < 0.001), intramedullary fixation (OR 7.15 (95% CI 6.50 to 7.86); p < 0.001), and sliding hip screw constructs (OR 2.34 (95% CI 2.19 to 2.50); p < 0.001). Blood transfusion during admission was significantly associated with higher rates of 30-day mortality (OR 1.35 (95% CI 1.19 to 1.53); p < 0.001) and 60-day mortality (OR 1.54 (95% CI 1.43 to 1.67); p < 0.001), as well as delays to postoperative mobilization, higher likelihood of not returning to their home, and longer length of stay. Conclusion. Blood transfusion after hip fracture was common, although practice varied nationally. RBCT is associated with adverse outcomes, which is most likely a reflection of perioperative anaemia, rather than any causal effect. Use of RBCT does not appear to reverse this effect, highlighting the importance of perioperative blood loss reduction. Cite this article: Bone Joint J 2022;104-B(11):1266–1272


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 294 - 298
1 Feb 2021
Hadeed MM Prakash H Yarboro SR Weiss DB

Aims. The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an intramedullary nail using a biomechanical model. This was used as a surrogate for immediate weight-bearing postoperatively. The goal was to help inform postoperative protocols. Methods. A biomechanical model of distal metaphyseal tibial fractures was created using a fourth-generation composite bone model. Three fracture patterns were tested: spiral, oblique, and multifragmented. Each fracture extended to within 4 cm to 5 cm of the plafond. The models were nearly-anatomically reduced and stabilized with an intramedullary nail and three distal locking screws. Cyclic loading was performed to simulate normal gait. Loading was completed in compression at 3,000 N at 1 Hz for a total of 70,000 cycles. Displacement (shortening, coronal and sagittal angulation) was measured at regular intervals. Results. The spiral and oblique fracture patterns withstood simulated weight-bearing with minimal displacement. The multifragmented model had early implant failure with breaking of the distal locking screws. The spiral fracture model shortened by a mean of 0.3 mm (SD 0.2), and developed a mean coronal angulation of 2.0° (SD 1.9°) and a mean sagittal angulation of 1.2° (SD 1.1°). On average, 88% of the shortening, 74% of the change in coronal alignment, and 75% of the change in sagittal alignment occurred in the first 2,500 cycles. No late acceleration of displacement was noted. The oblique fracture model shortened by a mean of 0.2 mm (SD 0.1) and developed a mean coronal angulation of 2.4° (SD 1.6°) and a mean sagittal angulation of 2.6° (SD 1.4°). On average, 44% of the shortening, 39% of the change in coronal alignment, and 79% of the change in sagittal alignment occurred in the first 2,500 cycles. No late acceleration of displacement was noted. Conclusion. For spiral and oblique fracture patterns, simulated weight-bearing resulted in a clinically acceptable degree of displacement. Most displacement occurred early in the test period, and the rate of displacement decreased over time. Based on this model, we offer evidence that early weight-bearing appears safe for well reduced oblique and spiral fractures, but not in multifragmented patterns that have poor bone contact. Cite this article: Bone Joint J 2021;103-B(2):294–298


Bone & Joint Open
Vol. 5, Issue 2 | Pages 147 - 153
19 Feb 2024
Hazra S Saha N Mallick SK Saraf A Kumar S Ghosh S Chandra M

Aims

Posterior column plating through the single anterior approach reduces the morbidity in acetabular fractures that require stabilization of both the columns. The aim of this study is to assess the effectiveness of posterior column plating through the anterior intrapelvic approach (AIP) in the management of acetabular fractures.

Methods

We retrospectively reviewed the data from R G Kar Medical College, Kolkata, India, from June 2018 to April 2023. Overall, there were 34 acetabulum fractures involving both columns managed by medial buttress plating of posterior column. The posterior column of the acetabular fracture was fixed through the AIP approach with buttress plate on medial surface of posterior column. Mean follow-up was 25 months (13 to 58). Accuracy of reduction and effectiveness of this technique were measured by assessing the Merle d’Aubigné score and Matta’s radiological grading at one year and at latest follow-up.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 72 - 81
1 Jan 2023
Stake IK Ræder BW Gregersen MG Molund M Wang J Madsen JE Husebye EE

Aims

The aim of this study was to compare the functional and radiological outcomes and the complication rate after nail and plate fixation of unstable fractures of the ankle in elderly patients.

Methods

In this multicentre study, 120 patients aged ≥ 60 years with an acute unstable AO/OTA type 44-B fracture of the ankle were randomized to fixation with either a nail or a plate and followed for 24 months after surgery. The primary outcome measure was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score. Secondary outcome measures were the Manchester-Oxford Foot Questionnaire, the Olerud and Molander Ankle score, the EuroQol five-dimension questionnaire, a visual analogue score for pain, complications, the quality of reduction of the fracture, nonunion, and the development of osteoarthritis.


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 449 - 454
15 Mar 2023
Zhang C Wang C Duan N Zhou D Ma T

Aims

The aim of this study was to assess the safety and clinical outcome of patients with a femoral shaft fracture and a previous complex post-traumatic femoral malunion who were treated with a clamshell osteotomy and fixation with an intramedullary nail (IMN).

Methods

The study involved a retrospective analysis of 23 patients. All had a previous, operatively managed, femoral shaft fracture with malunion due to hardware failure. They were treated with a clamshell osteotomy between May 2015 and March 2020. The mean age was 42.6 years (26 to 62) and 15 (65.2%) were male. The mean follow-up was 2.3 years (1 to 5). Details from their medical records were analyzed. Clinical outcomes were assessed using the quality of correction of the deformity, functional recovery, the healing time of the fracture, and complications.


Bone & Joint Open
Vol. 5, Issue 6 | Pages 524 - 531
24 Jun 2024
Woldeyesus TA Gjertsen J Dalen I Meling T Behzadi M Harboe K Djuv A

Aims

To investigate if preoperative CT improves detection of unstable trochanteric hip fractures.

Methods

A single-centre prospective study was conducted. Patients aged 65 years or older with trochanteric hip fractures admitted to Stavanger University Hospital (Stavanger, Norway) were consecutively included from September 2020 to January 2022. Radiographs and CT images of the fractures were obtained, and surgeons made individual assessments of the fractures based on these. The assessment was conducted according to a systematic protocol including three classification systems (AO/Orthopaedic Trauma Association (OTA), Evans Jensen (EVJ), and Nakano) and questions addressing specific fracture patterns. An expert group provided a gold-standard assessment based on the CT images. Sensitivities and specificities of surgeons’ assessments were estimated and compared in regression models with correlations for the same patients. Intra- and inter-rater reliability were presented as Cohen’s kappa and Gwet’s agreement coefficient (AC1).


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 795 - 800
1 Jul 2023
Parsons N Achten J Costa ML

Aims

To report the outcomes of patients with a fracture of the distal tibia who were treated with intramedullary nail versus locking plate in the five years after participating in the Fixation of Distal Tibia fracture (FixDT) trial.

Methods

The FixDT trial reported the results for 321 patients randomized to nail or locking plate fixation in the first 12 months after their injury. In this follow-up study, we report the results of 170 of the original participants who agreed to be followed up until five years. Participants reported their Disability Rating Index (DRI) and health-related quality of life (EuroQol five-dimension three-level questionnaire) annually by self-reported questionnaire. Further surgical interventions related to the fracture were also recorded.


Bone & Joint Open
Vol. 4, Issue 4 | Pages 273 - 282
20 Apr 2023
Gupta S Yapp LZ Sadczuk D MacDonald DJ Clement ND White TO Keating JF Scott CEH

Aims

To investigate health-related quality of life (HRQoL) of older adults (aged ≥ 60 years) after tibial plateau fracture (TPF) compared to preinjury and population matched values, and what aspects of treatment were most important to patients.

Methods

We undertook a retrospective, case-control study of 67 patients at mean 3.5 years (SD 1.3; 1.3 to 6.1) after TPF (47 patients underwent fixation, and 20 nonoperative management). Patients completed EuroQol five-dimension three-level (EQ-5D-3L) questionnaire, Lower Limb Function Scale (LEFS), and Oxford Knee Scores (OKS) for current and recalled prefracture status. Propensity score matching for age, sex, and deprivation in a 1:5 ratio was performed using patient level data from the Health Survey for England to obtain a control group for HRQoL comparison. The primary outcome was the difference in actual (TPF cohort) and expected (matched control) EQ-5D-3L score after TPF.


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1369 - 1378
1 Dec 2022
van Rijckevorsel VAJIM de Jong L Verhofstad MHJ Roukema GR

Aims

Factors associated with high mortality rates in geriatric hip fracture patients are frequently unmodifiable. Time to surgery, however, might be a modifiable factor of interest to optimize clinical outcomes after hip fracture surgery. This study aims to determine the influence of postponement of surgery due to non-medical reasons on clinical outcomes in acute hip fracture surgery.

Methods

This observational cohort study enrolled consecutively admitted patients with a proximal femoral fracture, for which surgery was performed between 1 January 2018 and 11 January 2021 in two level II trauma teaching hospitals. Patients with medical indications to postpone surgery were excluded. A total of 1,803 patients were included, of whom 1,428 had surgery < 24 hours and 375 had surgery ≥ 24 hours after admission.


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1385 - 1391
1 Oct 2018
Qvist AH Væsel MT Jensen CM Jensen SL

Aims. Recent studies of nonoperatively treated displaced midshaft clavicular fractures have shown a high incidence of nonunion and unsatisfactory functional outcome. Some studies have shown superior functional results and higher rates of healing following operative treatment. The aim of this study was to compare the outcome in these patients after nonoperative management with those treated with fixation. Patients and Methods. In a multicentre, parallel randomized controlled trial, 146 adult patients with an acute displaced fracture of the midthird of the clavicle were randomized to either nonoperative treatment with a sling (71, 55 men and 16 women with a mean age of 39 years, 18 to 60) or fixation with a pre-contoured plate and locking screws (75, 64 men and 11 women with a mean age of 40 years, 18 to 60). Outcome was assessed using the Disabilities of the Arm, Shoulder and Hand (DASH) Score, the Constant Score, and radiographical evidence of union. Patients were followed for one year. Results. A total of 60 patients in the nonoperative group and 64 in the operative group completed one-year follow-up. At three months’ follow-up, both the median DASH (1.7 vs 8.3) and median Constant scores (97 vs 90) were significantly better in the operated group (both p = 0.02). After six months and one year, there was no difference in the median DASH or Constant scores. The rate of nonunion was lower in the operative group (2 vs 11 patients, p < 0.02). Nine patients in the nonoperative group underwent surgery for nonunion. The plate was subsequently removed in 16 patients (25%). One patient had a new fracture after removal of the plate and one underwent revision surgery for failure of fixation. Conclusion. Fixation of a displaced midshaft clavicular fracture using a pre-contoured plate and locking screws results in faster functional recovery and a higher rate of union compared with nonoperative management, but the function of the shoulder is equal after six months and at one year. Cite this article: Bone Joint J 2018;100-B:1385–91


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 766 - 771
1 Jun 2020
Coughlin TA Nightingale JM Myint Y Forward DP Norrish AR Ollivere BJ

Aims. Hip fractures in patients < 60 years old currently account for only 3% to 4% of all hip fractures in England, but this proportion is increasing. Little is known about the longer-term patient-reported outcomes in this potentially more active population. The primary aim is to examine patient-reported outcomes following isolated hip fracture in patients aged < 60 years. The secondary aim is to determine an association between outcomes and different types of fracture pattern and/or treatment implants. Methods. All hip fracture patients aged 18 to 60 years admitted to a single centre over a 15-year period were used to identify the study group. Fracture pattern (undisplaced intracapsular, displaced intracapsular, and extracapsular) and type of operation (multiple cannulated hip screws, angular stable fixation, hemiarthroplasty, and total hip replacement) were recorded. The primary outcome measures were the Oxford Hip Score (OHS), the EuroQol five-dimension questionnaire (EQ-5D-3L), and EQ-visual analogue scale (VAS) scores. Preinjury scores were recorded by patient recall and postinjury scores were collected at a mean of 57 months (9 to 118) postinjury. Ethics approval was obtained prior to study commencement. Results. A total of 72 patients were included. There was a significant difference in pre- and post-injury OHS (mean 9.8 point reduction (38 to -20; p < 0.001)), EQ-5D (mean 0.208 reduction in index (0.897 to -0.630; p < 0.001)), and VAS , and VAS (mean 11.6 point reduction (70 to -55; p < 0.001)) Fracture pattern had a significant influence on OHS (p < 0.001) with extracapsular fractures showing the least favourable long-term outcome. Fixation type also impacted significantly on OHS (p = 0.011) with the worst outcomes in patients treated by hemiarthroplasty or angular stable fixation. Conclusion. There is a significant reduction in function and quality of life following injury, with all three patient-reported outcome measures used, indicating that this is a substantial injury in younger patients. Treatment with hemiarthroplasty or angular stable devices in this cohort were associated with a less favourable hip score outcome. Cite this article: Bone Joint J 2020;102-B(6):766–771