Arthroplasty has been shown to generate the most waste among all orthopaedic subspecialties, and it is estimated that hip and knee arthroplasty generate in excess of three million kg of waste annually in the UK. Infectious waste generates up to ten times more CO2 compared with recycled waste, and previous studies have shown that over 90% of waste in the infectious stream is misallocated. We assessed the effect of real-time waste segregation by an unscrubbed team member on waste generation in knee and hip arthroplasty cases, and compared this with a simple educational intervention during the ‘team brief’ at the start of the operating list across two sites. Waste was categorized into five categories: infectious, general, recycling, sharps, and linens. Each category was weighed at the end of each case using a digital weighing scale. At Site A (a tertiary orthopaedic hospital), pre-intervention data were collected for 16 total knee arthroplasy (TKA) and 15 total hip arthroplasty (THA) cases. Subsequently, for ten TKA and ten THA cases, an unscrubbed team member actively segregated waste in real-time into the correct streams. At Site B (a district general hospital), both pre- and post-intervention groups included ten TKA and ten THA cases. The intervention included reminding staff during the ‘team brief’ to segregate waste correctly.Aims
Methods
Deep surgical site infection (SSI) remains an unsolved problem after hip fracture. Debridement, antibiotic, and implant retention (DAIR) has become a mainstream treatment in elective periprosthetic joint infection; however, evidence for DAIR after infected hip hemiarthroplaty is limited. Patients who underwent a hemiarthroplasty between March 2007 and August 2018 were reviewed. Multivariable binary logistic regression was performed to identify and adjust for risk factors for SSI, and to identify factors predicting a successful DAIR at one year.Aims
Methods
The COVID-19 pandemic posed significant challenges to healthcare systems across the globe in 2020. There were concerns surrounding early reports of increased mortality among patients undergoing emergency or non-urgent surgery. We report the morbidity and mortality in patients who underwent arthroplasty procedures during the UK first stage of the pandemic. Institutional review board approval was obtained for a review of prospectively collected data on consecutive patients who underwent arthroplasty procedures between March and May 2020 at a specialist orthopaedic centre in the UK. Data included diagnoses, comorbidities, BMI, American Society of Anesthesiologists grade, length of stay, and complications. The primary outcome was 30-day mortality and secondary outcomes were prevalence of SARS-CoV-2 infection, medical and surgical complications, and readmission within 30 days of discharge. The data collated were compared with series from the preceding three months.Aims
Methods
Infection after surgery increases treatment costs and is associated with increased mortality. Hip fracture patients have historically had high rates of methicillin-resistant A total of 13,503 patients who presented with a hip fracture over 17 years formed the study population. Multivariable logistic regression was performed to determine risk factors for MRSA and SSI. Autoregressive integrated moving average (ARIMA) modelling adjusted for temporal trends in rates of MRSA. Kaplan-Meier estimators were generated to assess for changes in mortality.Aims
Methods
Wrist block has been used to provide pain relief
for many procedures on the hand and wrist but its role in arthroscopy
of the wrist remains unexplored. Chondrotoxicity has been a concern
with the intra-articular infiltration of local anaesthetic. We aimed
to evaluate and compare the analgesic effect of portal and wrist
joint infiltration with a wrist block on the pain experienced by
patients after arthroscopy of the wrist. A prospective, randomised, double-blind trial was designed and
patients undergoing arthroscopy of the wrist under general anaesthesia
as a day case were recruited for the study. Levo-bupivacaine was
used for both techniques. The effects were evaluated using a ten-point
visual analogue scale, and the use of analgesic agents was also
compared. The primary outcomes for statistical analyses were the
mean pain scores and the use of analgesia post-operatively. A total of 34 patients (63% females) were recruited to the portal
and joint infiltration group and 32 patients (59% males) to the
wrist block group. Mean age was 40.8 years in the first group and
39.7 years in the second group (p >
0.05). Both techniques provided
effective pain relief in the first hour and 24 hours post-operatively
but wrist block gave better pain scores at bedtime on the day of
surgery (p = 0.007) and at 24 hours post-operatively (p = 0.006). Wrist block provides better and more reliable analgesia in patients
undergoing arthroscopy of the wrist without exposing patients to
the risk of chondrotoxicity. Cite this article: