Advertisement for orthosearch.org.uk
Results 1 - 20 of 81
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1316 - 1320
1 Oct 2006
Azodi OS Bellocco R Eriksson K Adami J

We carried out a retrospective cohort study of 3309 patients undergoing primary total hip replacement to examine the impact of tobacco use and body mass index on the length of stay in hospital and the risk of short term post-operative complications. Heavy tobacco use was associated with an increased risk of systemic post-operative complications (p = 0.004). Previous and current smokers had a 43% and 56% increased risk of systemic complications, respectively, when compared with non-smokers. In heavy smokers, the risk increased by 121%. A high body mass index was significantly associated with an increased mean length of stay in hospital of between 4.7% and 7%. The risk of systemic complications was increased by 58% in the obese. Smoking and body mass index were not significantly related to the development of local complications. Greater efforts should be taken to reduce the impact of preventable life style factors, such as smoking and high body mass index, on the post-operative course of total hip replacement


Bone & Joint Research
Vol. 6, Issue 8 | Pages 506 - 513
1 Aug 2017
Sims AL Farrier AJ Reed MR Sheldon TA

Objectives. The objective of this study was to assess all evidence comparing the Thompson monoblock hemiarthroplasty with modular unipolar implants for patients requiring hemiarthroplasty of the hip with respect to mortality and complications. Methods. A literature search was performed to identify all relevant literature. The population consisted of patients undergoing hemiarthroplasty of the hip for fracture. The intervention was hemiarthroplasty of the hip with a comparison between Thompson and modular unipolar prostheses. Pubmed, Embase, CINAHL, Web of Science, PROSPERO and the Cochrane Central Register of Controlled Trials. The study designs included were randomised controlled trials (RCTs), well designed case control studies and retrospective or prospective cohort studies. Studies available in any language, published at any time until September 2015 were considered. Studies were included if they contained mortality or complications. Results. The initial literature search identified 4757 items for examination. Four papers were included in the final review. The pooled odds ratio for mortality was 1.3 (95% confidence Interval 0.78 to 2.46) favouring modular designs. The pooled odds ratio for post-operative complications was 1.1 (95% CI 0.79 to 1.55) favouring modular designs. Outcomes were reported at 12 or six months. These papers all contained potential sources of bias and significant clinical heterogeneity. Conclusion. The current evidence comparing monoblock versus modular implants in patients undergoing hemiarthroplasty is weak. Confidence intervals around the pooled odds ratios are broad and incorporate a value of one. Direct comparison of outcomes from these papers is fraught with difficulty and, as such, may well be misleading. A well designed randomised controlled trial would be helpful to inform evidence-based implant selection. Cite this article: A. L. Sims, A. J. Farrier, M. R. Reed, T. A. Sheldon. Thompson hemiarthroplasty versus modular unipolar implants for patients requiring hemiarthroplasty of the hip: A systematic review of the evidence. Bone Joint Res 2017;6:–513. DOI: 10.1302/2046-3758.68.BJR-2016-0256.R1


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 314 - 319
1 Mar 2005
Buttaro MA Pusso R Piccaluga F

Bone allografts can store and release high levels of vancomycin. We present our results of a two-stage treatment for infected hip arthroplasty with acetabular and femoral impaction grafting using vancomycin-loaded allografts. We treated 29 patients (30 hips) by removal of the implants, meticulous debridement, parenteral antibiotic therapy and second-stage reconstruction using vancomycin-supplemented impacted bone allografts and a standard cemented Charnley femoral component. The mean follow-up was 32.4 months (24 to 60). Infection control was obtained in 29 cases (re-infection rate of 3.3%; 95% confidence interval 0.08 to 17) without evidence of progressive radiolucent lines, demarcation or graft resorption. One patient had a further infection ten months after revision caused by a different pathogen. Associated post-operative complications were one traumatic periprosthetic fracture at 14 months, a single dislocation in two hips and four displacements of the greater trochanter. Vancomycin-supplemented allografts restored bone stock and provided sound fixation with a low incidence of further infection


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 790 - 795
1 Jun 2005
Eren A Ömeroglu H Güven M Ugutmen E Altintas F

We treated 26 hips (24 consecutive patients) with residual dysplasia by a technique of incomplete triple pelvic osteotomy. The mean age of the patients was 21.6 years. The mean values for the pre-operative centre-edge angle of Wiberg, the refined centre-edge angle, the acetabular angle of Sharp, the modified acetabular angle and femoral head lateralisation were 7.7°, −3.1°, 49.3°, 53.2° and 17.2 mm, respectively. After a mean follow-up of 3.3 years they were 27.0°, 13.0°, 38.9°, 44.3° and 15.9 mm, respectively (p < 0.05). The osteoarthritic grading changed adversely in one hip. The mean pre-operative and latest Harris hip scores were 74.9 and 93.0, respectively (p < 0.05). This technique provides a stable osteotomy with maintenance of the posterior column which allows early mobilisation and minimal internal fixation. The technique is not complex and requires minimal blood transfusion. The use of an image intensifier is not necessary and harvesting of a subcristal bone graft avoids post-operative complications at the donor site


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 173 - 178
1 Feb 2016
Sassoon A Nam D Jackups R Johnson SR Nunley RM Barrack RL

Aims. This study investigated whether the use of tranexamic acid (TXA) decreased blood loss and transfusion related cost following surface replacement arthroplasty (SRA). . Methods. A retrospective review of patients treated with TXA during a SRA, who did not receive autologous blood (TXA group) was performed. Two comparison groups were established; the first group comprised of patients who donated their own blood pre-operatively (auto group) and the second of patients who did not donate blood pre-operatively (control). Outcomes included transfusions, post-operative haemoglobin (Hgb), complications, and length of post-operative stay. . Results. Between 2009 and 2013, 150 patients undergoing SRA were identified for inclusion: 51 in the auto, 49 in the control, and 50 in the TXA group. There were no differences in the pre-operative Hgb concentrations between groups. The mean post-operative Hgb was 11.3 g/dL (9.1 to 13.6) in the auto and TXA groups, and 10.6 g/dL (8.1 to 12.1)in the control group (p = 0.001). Accounting for cost of transfusions, administration of TXA, and length of stay, the cost per patient was $1731, $339, and $185 for the auto, control and TXA groups, respectively. . Discussion. TXA use demonstrated higher post-operative Hgb concentrations when compared with controls and decreased peri-operative costs. Take home message: Tranexamic acid safely limits allogeneic transfusion, maintains post-operative haemoglobin, and decreases direct and indirect transfusion related costs in surface replacement arthroplasty. Cite this article: Bone Joint J 2016;98-B:173–8


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 31 - 35
1 Jan 2018
Berend KR Lombardi AV Berend ME Adams JB Morris MJ

Aims

To examine incidence of complications associated with outpatient total hip arthroplasty (THA), and to see if medical comorbidities are associated with complications or extended length of stay.

Patients and Methods

From June 2013 to December 2016, 1279 patients underwent 1472 outpatient THAs at our free-standing ambulatory surgery centre. Records were reviewed to determine frequency of pre-operative medical comorbidities and post-operative need for overnight stay and complications which arose.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 175 - 183
1 Feb 2017
Morita D Hasegawa Y Okura T Osawa Y Ishiguro N

Aims

Transtrochanteric rotational osteotomy (TRO) is performed for young patients with non-traumatic osteonecrosis of the femoral head (ONFH) to preserve the hip. We aimed to investigate the long-term outcomes and the risk factors for failure 15 years after this procedure.

Patients and Methods

This study included 95 patients (111 hips) with a mean age of 40 years (21 to 64) who underwent TRO for ONFH. The mean follow-up was 18.2 years (3 to 26). Kaplan–Meier survivorship analyses were performed with conversion to total hip arthroplasty (THA) and radiological failure due to secondary collapse of the femoral head or osteoarthritic changes as the endpoint. Multivariate analyses were performed to assess risk factors for each outcome.


The Bone & Joint Journal
Vol. 99-B, Issue 1_Supple_A | Pages 31 - 36
1 Jan 2017
Haynes J Nam D Barrack RL

Aims

The purpose of our study is to summarise the current scientific findings regarding the impact of obesity on total hip arthroplasty (THA); specifically the influence of obesity on the timing of THA, incidence of complications, and effect on clinical and functional outcomes.

Materials and Methods

We performed a systematic review that was compliant with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines to identify prospective studies from the PubMed/Medline, Embase, and Cochrane Library databases that evaluated primary THA in obese (body mass index (BMI) ≥ 30 kg/m2) patients.


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 187 - 193
1 Feb 2016
Lash NJ Whitehouse MR Greidanus NV Garbuz DS Masri BA Duncan CP

Aims

We present a case series of ten metal-on-polyethylene total hip arthroplasties (MoP THAs) with delayed dislocation associated with unrecognised adverse local tissue reaction due to corrosion at the trunnion and pseudotumour formation.

Methods

The diagnosis was not suspected in nine of the ten patients (six female/four male; mean age 66 years), despite treatment in a specialist unit (mean time from index surgery to revision was 58 months, 36 to 84). It was identified at revision surgery and subsequently confirmed by histological examination of resected tissue. Pre-operative assessment and culture results ruled out infection. A variety of treatment strategies were used, including resection of the pseudotumour and efforts to avoid recurrent dislocation.


Bone & Joint Research
Vol. 5, Issue 8 | Pages 338 - 346
1 Aug 2016
MacLeod AR Sullivan NPT Whitehouse MR Gill HS

Objectives

Modular junctions are ubiquitous in contemporary hip arthroplasty. The head-trunnion junction is implicated in the failure of large diameter metal-on-metal (MoM) hips which are the currently the topic of one the largest legal actions in the history of orthopaedics (estimated costs are stated to exceed $4 billion). Several factors are known to influence the strength of these press-fit modular connections. However, the influence of different head sizes has not previously been investigated. The aim of the study was to establish whether the choice of head size influences the initial strength of the trunnion-head connection.

Materials and Methods

Ti-6Al-4V trunnions (n = 60) and two different sizes of cobalt-chromium (Co-Cr) heads (28 mm and 36 mm; 30 of each size) were used in the study. Three different levels of assembly force were considered: 4 kN; 5 kN; and 6 kN (n = 10 each). The strength of the press-fit connection was subsequently evaluated by measuring the pull-off force required to break the connection. The statistical differences in pull-off force were examined using a Kruskal–Wallis test and two-sample Mann–Whitney U test. Finite element and analytical models were developed to understand the reasons for the experimentally observed differences.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1027 - 1035
1 Aug 2016
Pereira LC Kerr J Jolles BM

Aims

Using a systematic review, we investigated whether there is an increased risk of post-operative infection in patients who have received an intra-articular corticosteroid injection to the hip for osteoarthritis prior to total hip arthroplasty (THA).

Methods

Studies dealing with an intra-articular corticosteroid injection to the hip and infection following subsequent THA were identified from databases for the period between 1990 to 2013. Retrieved articles were independently assessed for their methodological quality.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 754 - 760
1 Jun 2016
Malek IA Royce G Bhatti SU Whittaker JP Phillips SP Wilson IRB Wootton JR Starks I

Aims

We assessed the difference in hospital based and early clinical outcomes between the direct anterior approach and the posterior approach in patients who undergo total hip arthroplasty (THA).

Patients and Methods

The outcome was assessed in 448 (203 males, 245 females) consecutive patients undergoing unilateral primary THA after the implementation of an ‘Enhanced Recovery’ pathway. In all, 265 patients (mean age: 71 years (49 to 89); 117 males and 148 females) had surgery using the direct anterior approach (DAA) and 183 patients (mean age: 70 years (26 to 100); 86 males and 97 females) using a posterior approach. The groups were compared for age, gender, American Society of Anesthesiologists grade, body mass index, the side of the operation, pre-operative Oxford Hip Score (OHS) and attendance at ‘Joint school’. Mean follow-up was 18.1 months (one to 50).


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 901 - 909
1 Jul 2016
Amstutz HC Le Duff MJ

Aims

Hip resurfacing arthroplasty (HRA) is an alternative to conventional total hip arthroplasty for patients with osteonecrosis (ON) of the femoral head. Our aim was to report the long-term outcome of HRA, which is not currently known.

Patients and Methods

Long-term survivorship, clinical scores and radiographic results for 82 patients (99 hips) treated with HRA for ON over a period of 18 years were reviewed retrospectively. The mean age of the 67 men and 15 women at the time of surgery was 40.8 years (14 to 64). Patients were resurfaced regardless of the size of the osteonecrotic lesion.


Aims

To investigate the longevity of uncemented fixation of a femoral component in total hip arthroplasty (THA) in patients with Dorr type C proximal femoral morphology.

Patients and Methods

A total of 350 consecutive uncemented THA in 320 patients were performed between 1983 and 1987, by a single surgeon using the Taperloc femoral component. The 63 patients (68 hips) with Dorr type C proximal femoral morphology were the focus of this review. The mean age of the patients was 69 years (24 to 88) and mean follow-up was 16.6 years (ten to 29). Survival analysis included eight patients (eight hips) who died without undergoing revision surgery prior to obtaining ten years follow-up. All 55 surviving patients (60 hips) were available for clinical assessment and radiographic review. As a comparator group, the survival and implant fixation in the remaining 282 THAs (257 patients) with Dorr type A and B morphology were evaluated. The mean age of these patients was 52 years (20 to 82).


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 320 - 325
1 Mar 2016
Gundtoft PH Pedersen AB Schønheyder HC Overgaard S

Aims

The purpose of this study was to validate the diagnosis of periprosthetic joint infection (PJI) in the Danish Hip Arthroplasty Register (DHR).

Patients and Methods

We identified a cohort of patients from the DHR who had undergone primary total hip arthroplasty (THA) since 1 January 2005 and followed them until first-time revision, death, emigration or until 31 December 2012.

Revision for PJI, as registered in the DHR, was validated against a benchmark which included information from microbiology databases, prescription registers, clinical biochemistry registers and clinical records.

We estimated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for PJI in the DHR alone and in the DHR when combined with microbiology databases.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1470 - 1474
1 Nov 2015
Selvarajah E Hooper G Grabowski K Frampton C Woodfield TBF Inglis G

Polyethylene wear debris can cause osteolysis and the failure of total hip arthroplasty. We present the five-year wear rates of a highly cross-linked polyethylene (X3) bearing surface when used in conjunction with a 36 mm ceramic femoral head.

This was a prospective study of a cohort of 100 THAs in 93 patients. Pain and activity scores were measured pre- and post-operatively. Femoral head penetration was measured at two months, one year, two years and at five years using validated edge-detecting software (PolyWare Auto).

At a mean of 5.08 years (3.93 to 6.01), 85 hips in 78 patients were available for study. The mean age of these patients was 59.08 years (42 to 73, the mean age of males (n = 34) was 59.15 years, and females (n = 44) was 59.02 years). All patients had significant improvement in their functional scores (p < 0.001). The steady state two-dimensional linear wear rate was 0.109 mm/year. The steady state volumetric wear rate was 29.61 mm3/year. No significant correlation was found between rate of wear and age (p = 0.34), acetabular component size (p = 0.12) or clinical score (p = 0.74).

Our study shows low steady state wear rates at five years in X3 highly cross-linked polyethylene in conjunction with a 36 mm ceramic femoral head. The linear wear rate was almost identical to the osteolysis threshold of 0.1 mm/year recommended in the literature.

Cite this article: Bone Joint J 2015;97-B:1470–4.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 299 - 305
1 Mar 2014
Bell KR Clement ND Jenkins PJ Keating JF

We performed a case–control study to compare the rates of further surgery, revision and complications, operating time and survival in patients who were treated with either an uncemented hydroxyapatite-coated Corail bipolar femoral stem or a cemented Exeter stem for a displaced intracapsular fracture of the hip. The mean age of the patients in the uncemented group was 82.5 years (53 to 97) and in the cemented group was 82.7 years (51 to 99) We used propensity score matching, adjusting for age, gender and the presence or absence of dementia and comorbidities, to produce a matched cohort receiving an Exeter stem (n = 69) with which to compare the outcome of patients receiving a Corail stem (n = 69). The Corail had a significantly lower all-cause rate of further surgery (p = 0.016; odds ratio (OR) 0.18, 95% CI 0.04 to 0.84) and number of hips undergoing major further surgery (p = 0.029; OR 0.13, 95% CI 0.01 to 1.09). The mean operating time was significantly less for the Corail group than for the cemented Exeter group (59 min [12 to 136] vs 70 min [40 to 175], p = 0.001). The Corail group also had a lower risk of a peri-prosthetic fracture (p = 0.042; OR 0.19, 95% CI 0.01 to 1.42) . There was no difference in the mortality rate between the groups. There were significantly fewer complications in the uncemented group, suggesting that the use of this stem would result in a decreased rate of morbidity in these frail patients. Whether this relates to an improved functional outcome remains unknown.

Cite this article: Bone Joint J 2014;96-B:299–305.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1455 - 1458
1 Nov 2014
Amanatullah DF Rachala SR Trousdale RT Sierra RJ

Dysplasia of the hip, hypotonia, osteopenia, ligamentous laxity, and mental retardation increase the complexity of performing and managing patients with Down syndrome who require total hip replacement (THR). We identified 14 patients (six males, eight females, 21 hips) with Down syndrome and degenerative disease of the hip who underwent THR, with a minimum follow-up of two years from 1969 to 2009. In seven patients, bilateral THRs were performed while the rest had unilateral THRs. The mean clinical follow-up was 5.8 years (standard deviation (sd) 4.7; 2 to 17). The mean Harris hip score was 37.9 points (sd 7.8) pre-operatively and increased to 89.2 (sd 12.3) at final follow-up (p = 1x10-9). No patient suffered a post-operative dislocation. In three patients, four hips had revision THR for aseptic loosening at a mean follow-up of 7.7 years (sd 6.3; 3 to 17). This rate of revision THR was higher than expected. Our patients with Down syndrome benefitted clinically from THR at mid-term follow-up.

Cite this article: Bone Joint J 2014;96-B:1455–8.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1338 - 1344
1 Oct 2015
te Stroet MAJ Keurentjes JC Rijnen WHC Gardeniers JWM Verdonschot N Slooff TJJH Schreurs BW

We present the results of 62 consecutive acetabular revisions using impaction bone grafting and a cemented polyethylene acetabular component in 58 patients (13 men and 45 women) after a mean follow-up of 27 years (25 to 30). All patients were prospectively followed. The mean age at revision was 59.2 years (23 to 82).

We performed Kaplan–Meier (KM) analysis and also a Competing Risk (CR) analysis because with long-term follow-up, the presence of a competing event (i.e. death) prevents the occurrence of the endpoint of re-revision.

A total of 48 patients (52 hips) had died or had been re-revised at final review in March 2011. None of the deaths were related to the surgery. The mean Harris hip score of the ten surviving hips in ten patients was 76 points (45 to 99).

The KM survivorship at 25 years for the endpoint ‘re-revision for any reason’ was 58.0% (95% confidence interval (CI) 38 to 73) and for ‘re-revision for aseptic loosening’ 72.1% (95% CI 51 to 85). With the CR analysis we calculated the KM analysis overestimates the failure rate with respectively 74% and 93% for these endpoints. The current study shows that acetabular impaction bone grafting revisions provide good clinical results at over 25 years.

Cite this article: Bone Joint J 2015;97-B:1338–44.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 617 - 622
1 May 2015
Haddad FS Konan S Tahmassebi J

The aim of this study was to evaluate the ten-year clinical and functional outcome of hip resurfacing and to compare it with that of cementless hip arthroplasty in patients under the age of 55 years.

Between 1999 and 2002, 80 patients were enrolled into the study: 24 were randomised (11 to hip resurfacing, 13 to total hip arthroplasty), 18 refused hip resurfacing and chose cementless total hip arthroplasty with a 32 mm bearing, and 38 insisted on resurfacing. The mean follow-up for all patients was 12.1 years (10 to 14).

Patients were assessed clinically and radiologically at one year, five years and ten years. Outcome measures included EuroQol EQ5D, Oxford, Harris hip, University of California Los Angeles and University College Hospital functional scores.

No differences were seen between the two groups in the Oxford or Harris hip scores or in the quality of life scores. Despite a similar aspiration to activity pre-operatively, a higher proportion of patients with a hip resurfacing were running and involved in sport and heavy manual labour after ten years.

We found significantly higher function scores in patients who had undergone hip resurfacing than in those with a cementless hip arthroplasty at ten years. This suggests a functional advantage for hip resurfacing. There were no other attendant problems.

Cite this article: Bone Joint J 2015; 97-B:617–22.