Advertisement for orthosearch.org.uk
Results 1 - 20 of 611
Results per page:
Bone & Joint Open
Vol. 3, Issue 6 | Pages 485 - 494
13 Jun 2022
Jaubert M Le Baron M Jacquet C Couvreur A Fabre-Aubrespy M Flecher X Ollivier M Argenson J

Aims. Two-stage exchange revision total hip arthroplasty (THA) performed in case of periprosthetic joint infection (PJI) has been considered for many years as being the gold standard for the treatment of chronic infection. However, over the past decade, there have been concerns about its safety and its effectiveness. The purposes of our study were to investigate our practice, collecting the overall spacer complications, and then to analyze their risk factors. Methods. We retrospectively included 125 patients with chronic hip PJI who underwent a staged THA revision performed between January 2013 and December 2019. All spacer complications were systematically collected, and risk factors were analyzed. Statistical evaluations were performed using the Student's t-test, Mann-Whitney U test, and Fisher's exact test. Results. Our staged exchange practice shows poor results, which means a 42% mechanical spacer failure rate, and a 20% recurrent infection rate over the two years average follow-up period. Moreover, we found a high rate of spacer dislocation (23%) and a low rate of spacer fracture (8%) compared to the previous literature. Our findings stress that the majority of spacer complications and failures is reflecting a population with high comorbid burden, highlighted by the American Society of Anesthesiology grade, Charlson Comorbidity Index, and Lee score associations, as well as the cardiac, pulmonary, kidney, or hepatic chronic conditions. Conclusion. Our experience of a two-stage hip exchange revision noted important complication rates associated with high failure rates of polymethylmethacrylate spacers. These findings must be interpreted in the light of the patient’s comorbidity profiles, as the elective population for staged exchange has an increasing comorbid burden leading to poor results. In order to provide better results for this specific population, our conclusion suggests that comparative strategy studies are required to improve our therapeutic indication. Cite this article: Bone Jt Open 2022;3(6):485–494


Bone & Joint Open
Vol. 3, Issue 6 | Pages 455 - 462
6 Jun 2022
Nwankwo H Mason J Costa ML Parsons N Redmond A Parsons H Haque A Kearney RS

Aims

To compare the cost-utility of removable brace compared with cast in the management of adult patients with ankle fracture.

Methods

A within-trial economic evaluation conducted from the UK NHS and personnel social services (PSS) perspective. Health resources and quality-of-life data were collected as part of the Ankle Injury Rehabilitation (AIR) multicentre, randomized controlled trial over a 12-month period using trial case report forms and patient-completed questionnaires. Cost-utility analysis was estimated in terms of the incremental cost per quality adjusted life year (QALY) gained. Estimate uncertainty was explored by bootstrapping, visualized on the incremental cost-effectiveness ratio plane. Net monetary benefit and probability of cost-effectiveness were evaluated at a range of willingness-to-pay thresholds and visualized graphically.


Bone & Joint Research
Vol. 5, Issue 4 | Pages 106 - 115
1 Apr 2016
Gruber HE Ode G Hoelscher G Ingram J Bethea S Bosse MJ

Objectives. The biomembrane (induced membrane) formed around polymethylmethacrylate (PMMA) spacers has value in clinical applications for bone defect reconstruction. Few studies have evaluated its cellular, molecular or stem cell features. Our objective was to characterise induced membrane morphology, molecular features and osteogenic stem cell characteristics. Methods. Following Institutional Review Board approval, biomembrane specimens were obtained from 12 patient surgeries for management of segmental bony defects (mean patient age 40.7 years, standard deviation 14.4). Biomembranes from nine tibias and three femurs were processed for morphologic, molecular or stem cell analyses. Gene expression was determined using the Affymetrix GeneChip Operating Software (GCOS). Molecular analyses compared biomembrane gene expression patterns with a mineralising osteoblast culture, and gene expression in specimens with longer spacer duration (> 12 weeks) with specimens with shorter durations. Statistical analyses used the unpaired student t-test (two tailed; p < 0.05 was considered significant). Results. Average PMMA spacer in vivo time was 11.9 weeks (six to 18). Trabecular bone was present in 33.3% of the biomembrane specimens; bone presence did not correlate with spacer duration. Biomembrane morphology showed high vascularity and collagen content and positive staining for the key bone forming regulators, bone morphogenetic protein 2 (BMP2) and runt-related transcription factor 2 (RUNX2). Positive differentiation of cultured biomembrane cells for osteogenesis was found in cells from patients with PMMA present for six to 17 weeks. Stem cell differentiation showed greater variability in pluripotency for osteogenic potential (70.0%) compared with chondrogenic or adipogenic potentials (100% and 90.0%, respectively). Significant upregulation of BMP2 and 6, numerous collagens, and bone gla protein was present in biomembrane compared with the cultured cell line. Biomembranes with longer resident PMMA spacer duration (vs those with shorter residence) showed significant upregulation of bone-related, stem cell, and vascular-related genes. Conclusion. The biomembrane technique is gaining favour in the management of complicated bone defects. Novel data on biological mechanisms provide improved understanding of the biomembrane’s osteogenic potential and molecular properties. Cite this article: Dr H. E. Gruber. Osteogenic, stem cell and molecular characterisation of the human induced membrane from extremity bone defects. Bone Joint Res 2016;5:106–115. DOI: 10.1302/2046-3758.54.2000483


Bone & Joint Open
Vol. 1, Issue 4 | Pages 47 - 54
2 Apr 2020
Al-Mohrej OA Elshaer AK Al-Dakhil SS Sayed AI Aljohar S AlFattani AA Alhussainan TS

Introduction. Studies have addressed the issue of increasing prevalence of work-related musculoskeletal (MSK) pain among different occupations. However, contributing factors to MSK pain have not been fully investigated among orthopaedic surgeons. Thus, this study aimed to approximate the prevalence and predictors of MSK pain among Saudi orthopaedic surgeons working in Riyadh, Saudi Arabia. Methods. A cross-sectional study using an electronic survey was conducted in Riyadh. The questionnaire was distributed through email among orthopaedic surgeons in Riyadh hospitals. Standardized Nordic questionnaires for the analysis of musculoskeletal symptoms were used. Descriptive measures for categorical and numerical variables were presented. Student’s t-test and Pearson’s χ2 test were used. The level of statistical significance was set at p ≤ 0.05. Results. The response rate was 80.3%, with a total number of 179 of Saudi orthopaedic surgeons (173 males and six females). Of our sample, 67.0% of the respondents complained of having MSK pain. The most commonly reported MSK pain was lower back (74.0%), followed by neck (58.2%). Age and body mass index were implicated in the development of more than one type of MSK pain. Increased years of experience (≥ 6 years) was linked to shoulder/elbow, lower back, and hip/thigh pain. Smoking is widely associated with lower back pain development, whereas physicians who do not smoke and exercise regularly reported fewer pain incidences. Excessive bending and twisting during daily practice have been correlated with increased neck pain. Conclusion. MSK pain was found to be common among Saudi orthopaedic surgeons. Further extensive research should be conducted to understand and analyze the risk factors involved and search for possible improvements to avoid further complications. However, ergonomics education during surgical training could be effective at modifying behaviors and reducing MSK pain manifestations


Bone & Joint Research
Vol. 7, Issue 4 | Pages 289 - 297
1 Apr 2018
Sanghani-Kerai A Osagie-Clouard L Blunn G Coathup M

Objectives. This study aimed to assess the effect of age and osteoporosis on the proliferative and differentiating capacity of bone-marrow-derived mesenchymal stem cells (MSCs) in female rats. We also discuss the role of these factors on expression and migration of cells along the C-X-C chemokine receptor type 4 (CXCR-4) / stromal derived factor 1 (SDF-1) axis. Methods. Mesenchymal stem cells were harvested from the femora of young, adult, and osteopenic Wistar rats. Cluster of differentiation (CD) marker and CXCR-4 expression was measured using flow cytometry. Cellular proliferation was measured using Alamar Blue, osteogenic differentiation was measured using alkaline phosphatase expression and alizarin red production, and adipogenic differentiation was measured using Oil red O. Cells were incubated in Boyden chambers to quantify their migration towards SDF-1. Data was analyzed using a Student’s t-test, where p-values < 0.05 were considered significant. Results. CD marker expression and proliferation of the MSCs from the three groups was not significantly different. The young MSCs demonstrated significantly increased differentiation into bone and fat and superior migration towards SDF-1. The migration of SDF-1 doubled with young rats compared with the adult rats (p = 0.023) and it was four times higher when compared with cells isolated from ovariectomized (OVX) osteopenic rats (p = 0.013). Conclusion. Young rat MSCs are significantly more responsive to osteogenic differentiation, and, contrary to other studies, also demonstrated increased adipogenic differentiation compared with cells from adult and ostopenic rats. Young-rat-derived cells also showed superior migration towards SDF-1 compared with MSCs from OVX and adult control rats. Cite this article: A. Sanghani-Kerai, L. Osagie-Clouard, G. Blunn, M. Coathup. The influence of age and osteoporosis on bone marrow stem cells from rats. Bone Joint Res 2018;7:289–297. DOI: 10.1302/2046-3758.74.BJR-2017-0302.R1


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1175 - 1181
1 Sep 2018
Benca E Willegger M Wenzel F Hirtler L Zandieh S Windhager R Schuh R

Aims. The traditional transosseus flexor hallucis longus (FHL) tendon transfer for patients with Achilles tendinopathy requires two incisions to harvest a long tendon graft. The use of a bio-tenodesis screw enables a short graft to be used and is less invasive, but lacks supporting evidence about its biomechanical behaviour. We aimed, in this study, to compare the strength of the traditional transosseus tendon-to-tendon fixation with tendon-to-bone fixation using a tenodesis screw, in cyclical loading and ultimate load testing. Materials and Methods. Tendon grafts were undertaken in 24 paired lower-leg specimens and randomly assigned in two groups using fixation with a transosseus suture (suture group) or a tenodesis screw (screw group). The biomechanical behaviour was evaluated using cyclical and ultimate loading tests. The Student’s t-test was performed to assess statistically significant differences in bone mineral density (BMD), displacement, the slope of the load-displacement curves, and load to failure. Results. The screw group showed less displacement (loosening) during cyclical loading, which was significant during 300, 500, 600, 700, 800, 900, and 1000 cycles (p < 0.05: other cycles: 0.079 < p < 0.402). Compared with the suture group, the screw group had higher mean ultimate load values (133.6 N, . sd. 73.5 vs 110.1 N,. sd. 46.2; p = 0.416). Conclusion. Fixation of the FHL tendon with a tenodesis screw enables a less invasive procedure to be undertaken and shows similar biomechanical behaviour and primary strength compared with fixation using a transosseus suture. Cite this article: Bone Joint J 2018;100-B:1175–81


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 84 - 90
1 Jun 2019
Charette RS Sloan M Lee G

Aims. Total hip arthroplasty (THA) is gaining popularity as a treatment for displaced femoral neck fractures (FNFs), especially in physiologically younger patients. While THA for osteoarthritis (OA) has demonstrated low complication rates and increased quality of life, results of THA for acute FNF are not as clear. Currently, a THA performed for FNF is included in an institutional arthroplasty bundle without adequate risk adjustment, potentially placing centres participating in fracture care at financial disadvantage. The purpose of this study is to report on perioperative complication rates after THA for FNF compared with elective THA performed for OA of the hip. Patients and Methods. The American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP) database between 2008 and 2016 was queried. Patients were identified using the THA Current Procedural Terminology (CPT) code and divided into groups by diagnosis: OA in one and FNF in another. Univariate statistics were performed. Continuous variables were compared between groups using Student’s t-test, and the chi-squared test was used to compare categorical variables. Multivariate and propensity-matched logistic regression analyses were performed to control for risk factors of interest. Results. Analyses included 139 635 patients undergoing THA. OA was the indication in 135 013 cases and FNF in 4622 cases. After propensity matching, mortality within 30 days (1.8% vs 0.3%; p < 0.001) and major morbidity (24.2% vs 19%; p < 0.001) were significantly higher among FNF patients. Re-operation (3.7% vs 2.7%; p = 0.014) and re-admission (7.3% vs 5.5%; p = 0.002) were significantly higher among FNF patients. Hip fracture patients had significantly longer operative time and length of stay (LOS), and were significantly less likely to be discharged to their home. Multivariate analyses gave similar results. Conclusion. This large database study showed a higher risk of postoperative complications including mortality, major morbidity, re-operation, re-admission, prolonged operative time, increased LOS, and decreased likelihood of discharge home in patients undergoing THA for FNF compared with OA. While THA is a good option for FNF patients, there are increased costs and financial risks to centres with a joint arthroplasty bundle programme participating in fracture care. Cite this article: Bone Joint J 2019;101-B(6 Supple B):84–90


Bone & Joint Research
Vol. 6, Issue 10 | Pages 577 - 583
1 Oct 2017
Sallent A Vicente M Reverté MM Lopez A Rodríguez-Baeza A Pérez-Domínguez M Velez R

Objectives. To assess the accuracy of patient-specific instruments (PSIs) versus standard manual technique and the precision of computer-assisted planning and PSI-guided osteotomies in pelvic tumour resection. Methods. CT scans were obtained from five female cadaveric pelvises. Five osteotomies were designed using Mimics software: sacroiliac, biplanar supra-acetabular, two parallel iliopubic and ischial. For cases of the left hemipelvis, PSIs were designed to guide standard oscillating saw osteotomies and later manufactured using 3D printing. Osteotomies were performed using the standard manual technique in cases of the right hemipelvis. Post-resection CT scans were quantitatively analysed. Student’s t-test and Mann–Whitney U test were used. Results. Compared with the manual technique, PSI-guided osteotomies improved accuracy by a mean 9.6 mm (p < 0.008) in the sacroiliac osteotomies, 6.2 mm (p < 0.008) and 5.8 mm (p < 0.032) in the biplanar supra-acetabular, 3 mm (p < 0.016) in the ischial and 2.2 mm (p < 0.032) and 2.6 mm (p < 0.008) in the parallel iliopubic osteotomies, with a mean linear deviation of 4.9 mm (p < 0.001) for all osteotomies. Of the manual osteotomies, 53% (n = 16) had a linear deviation > 5 mm and 27% (n = 8) were > 10 mm. In the PSI cases, deviations were 10% (n = 3) and 0 % (n = 0), respectively. For angular deviation from pre-operative plans, we observed a mean improvement of 7.06° (p < 0.001) in pitch and 2.94° (p < 0.001) in roll, comparing PSI and the standard manual technique. Conclusion. In an experimental study, computer-assisted planning and PSIs improved accuracy in pelvic tumour resections, bringing osteotomy results closer to the parameters set in pre-operative planning, as compared with standard manual techniques. Cite this article: A. Sallent, M. Vicente, M. M. Reverté, A. Lopez, A. Rodríguez-Baeza, M. Pérez-Domínguez, R. Velez. How 3D patient-specific instruments improve accuracy of pelvic bone tumour resection in a cadaveric study. Bone Joint Res 2017;6:577–583. DOI: 10.1302/2046-3758.610.BJR-2017-0094.R1


Bone & Joint Research
Vol. 5, Issue 11 | Pages 586 - 593
1 Nov 2016
Rakhra KS Bonura AA Nairn R Schweitzer ME Kolanko NM Beaule PE

Objectives. The purpose of this study was to compare the thickness of the hip capsule in patients with surgical hip disease, either with cam-femoroacetabular impingement (FAI) or non-FAI hip pathology, with that of asymptomatic control hips. Methods. A total of 56 hips in 55 patients underwent a 3Tesla MRI of the hip. These included 40 patients with 41 hips with arthroscopically proven hip disease (16 with cam-FAI; nine men, seven women; mean age 39 years, 22 to 58) and 25 with non-FAI chondrolabral pathology (four men, 21 women; mean age 40 years, 18 to 63) as well as 15 asymptomatic volunteers, whose hips served as controls (ten men, five women; mean age 62 years, 33 to 77). The maximal capsule thickness was measured anteriorly and superiorly, and compared within and between the three groups with a gender subanalysis using student’s t-test. The correlation between alpha angle and capsule thickness was determined using Pearson’s correlation coefficient. Results. Superiorly, the hip capsule was significantly greater in cam- (p = 0.028) and non-FAI (p = 0.048) surgical groups compared with the asymptomatic group. Within groups, the superior capsule thickness was significantly greater than the anterior in cam- (p < 0.001) and non-FAI (p < 0.001) surgical groups, but not in the control group. There was no significant correlation between the alpha angle and capsule thickness. There were no gender differences identified in the thickness of the hip capsule. Conclusion. The thickness of the capsule does not differ between cam- and non-FAI diseased hips, and thus may not be specific for a particular aetiology of hip disease. The capsule is, however, thicker in diseased surgical hips compared with asymptomatic control hips. Cite this article: K. S. Rakhra, A. A. Bonura, R. Nairn, M. E. Schweitzer, N. M. Kolanko, P. E. Beaule. Is the hip capsule thicker in diseased hips? Bone Joint Res 2016;5:586–593. DOI: 10.1302/2046-3758.511.2000495


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1279 - 1285
1 Dec 2023
Baker JF Nadar AC Jouflas AC Smith LS Sachdeva S Yakkanti MR Malkani AL

Aims

The use of cementless total knee arthroplasty (TKA) components has increased during the past decade. The initial design of cementless metal-backed patellar components had shown high failure rates due to many factors. The aim of this study was to evaluate the clinical results of a second-generation cementless, metal-backed patellar component of a modern design.

Methods

This was a retrospective review of 707 primary TKAs in 590 patients from a single institution, using a cementless, metal-backed patellar component with a mean follow-up of 6.9 years (2 to 12). A total of 409 TKAs were performed in 338 females and 298 TKAs in 252 males. The mean age of the patients was 63 years (34 to 87) and their mean BMI was 34.3 kg/m2 (18.8 to 64.5). The patients were chosen to undergo a cementless procedure based on age and preoperative radiological and intraoperative bone quality. Outcome was assessed using the Knee Society knee and function scores and range of motion (ROM), complications, and revisions.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 656 - 661
1 Jul 2024
Bolbocean C Hattab Z O'Neill S Costa ML

Aims

Cemented hemiarthroplasty is an effective form of treatment for most patients with an intracapsular fracture of the hip. However, it remains unclear whether there are subgroups of patients who may benefit from the alternative operation of a modern uncemented hemiarthroplasty – the aim of this study was to investigate this issue. Knowledge about the heterogeneity of treatment effects is important for surgeons in order to target operations towards specific subgroups who would benefit the most.

Methods

We used causal forest analysis to compare subgroup- and individual-level treatment effects between cemented and modern uncemented hemiarthroplasty in patients aged > 60 years with an intracapsular fracture of the hip, using data from the World Hip Trauma Evaluation 5 (WHiTE 5) multicentre randomized clinical trial. EuroQol five-dimension index scores were used to measure health-related quality of life at one, four, and 12 months postoperatively.


Aims

Achievement of accurate microbiological diagnosis prior to revision is key to reducing the high rates of persistent infection after revision knee surgery. The effect of change in the microorganism between the first- and second-stage revision of total knee arthroplasty for periprosthetic joint infection (PJI) on the success of management is not clear.

Methods

A two-centre retrospective cohort study was conducted to review the outcome of patients who have undergone two-stage revision for treatment of knee arthroplasty PJI, focusing specifically on isolated micro-organisms at both the first- and second-stage procedure. Patient demographics, medical, and orthopaedic history data, including postoperative outcomes and subsequent treatment, were obtained from the electronic records and medical notes.


Aims

This study investigated vancomycin-microbubbles (Vm-MBs) and meropenem (Mp)-MBs with ultrasound-targeted microbubble destruction (UTMD) to disrupt biofilms and improve bactericidal efficiency, providing a new and promising strategy for the treatment of device-related infections (DRIs).

Methods

A film hydration method was used to prepare Vm-MBs and Mp-MBs and examine their characterization. Biofilms of methicillin-resistant Staphylococcus aureus (MRSA) and Escherichia coli were treated with different groups. Biofilm biomass differences were determined by staining. Thickness and bacterial viability were observed with confocal laser scanning microscope (CLSM). Colony counts were determined by plate-counting. Scanning electron microscopy (SEM) observed bacterial morphology.


Bone & Joint Open
Vol. 4, Issue 2 | Pages 110 - 119
21 Feb 2023
Macken AA Prkić A van Oost I Spekenbrink-Spooren A The B Eygendaal D

Aims

The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry.

Methods

All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for survival analysis, and a logistic regression model was used to assess the factors associated with revision.


Bone & Joint Research
Vol. 5, Issue 9 | Pages 387 - 392
1 Sep 2016
Morris WZ Fowers CA Yuh RT Gebhart JJ Salata MJ Liu RW

Objectives. The spinopelvic relationship (including pelvic incidence) has been shown to influence pelvic orientation, but its potential association with femoroacetabular impingement has not been thoroughly explored. The purpose of this study was to prove the hypothesis that decreasing pelvic incidence is associated with increased risk of cam morphology. Methods. Two matching cohorts were created from a collection of cadaveric specimens with known pelvic incidences: 50 subjects with the highest pelvic incidence (all subjects > 60°) and 50 subjects with the lowest pelvic incidence (all subjects < 35°). Femoral version, acetabular version, and alpha angles were directly measured from each specimen bilaterally. Cam morphology was defined as alpha angle > 55°. Differences between the two cohorts were analysed with a Student’s t-test and the difference in incidence of cam morphology was assessed using a chi-squared test. The significance level for all tests was set at p < 0.05. Results. Cam morphology was identified in 47/100 (47%) femurs in the cohort with pelvic incidence < 35° and in only 25/100 (25%) femurs in the cohort with pelvic incidence > 60° (p = 0.002). The mean alpha angle was also greater in the cohort with pelvic incidence < 35° (mean 53.7°, . sd. 10.7° versus mean 49.7°, . sd. 10.6°; p = 0.008). Conclusions. Decreased pelvic incidence is associated with development of cam morphology. We propose a novel theory wherein subjects with decreased pelvic incidence compensate during gait (to maintain optimal sagittal balance) through anterior pelvic tilt, creating artificial anterior acetabular overcoverage and recurrent impingement that increases risk for cam morphology. Cite this article: W. Z. Morris, C. A. Fowers, R. T. Yuh, J. J. Gebhart, M. J. Salata, R. W. Liu. Decreasing pelvic incidence is associated with greater risk of cam morphology. Bone Joint Res 2016;5:387–392. DOI: 10.1302/2046-3758.59.BJR-2016-0028.R1


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 3 - 8
1 Jul 2021
Roberts HJ Barry J Nguyen K Vail T Kandemir U Rogers S Ward D

Aims

While interdisciplinary protocols and expedited surgical treatment improve the management of hip fractures in the elderly, the impact of such interventions on patients specifically undergoing arthroplasty for a femoral neck fracture is not clear. We sought to evaluate the efficacy of an interdisciplinary protocol for the management of patients with a femoral neck fracture who are treated with an arthroplasty.

Methods

In 2017, our institution introduced a standardized interdisciplinary hip fracture protocol. We retrospectively reviewed adult patients who underwent hemiarthroplasty (HA) or total hip arthroplasty (THA) for femoral neck fracture between July 2012 and March 2020, and compared patient characteristics and outcomes between those treated before and after the introduction of the protocol.


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1075 - 1081
17 Dec 2021
Suthar A Yukata K Azuma Y Suetomi Y Yamazaki K Seki K Sakai T Fujii H

Aims

This study aimed to investigate the relationship between changes in patellar height and clinical outcomes at a mean follow-up of 7.7 years (5 to 10) after fixed-bearing posterior-stabilized total knee arthroplasty (PS-TKA).

Methods

We retrospectively evaluated knee radiographs of 165 knees, which underwent fixed-bearing PS-TKA with patella resurfacing. The incidence of patella baja and changes in patellar height over a minimum of five years of follow-up were determined using Insall-Salvati ratio (ISR) measurement. We examined whether patella baja (ISR < 0.8) at final follow-up affected clinical outcomes, knee joint range of motion (ROM), and Knee Society Score (KSS). We also assessed inter- and intrarater reliability of ISR measurements and focused on the relationship between patellar height reduction beyond measurement error and clinical outcomes.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 477 - 480
1 Apr 2007
Spencer JM Chauhan SK Sloan K Taylor A Beaver RJ

We previously compared the component alignment in total knee replacement using a computer-navigated technique with a conventional jig-based method. We randomly allocated 71 patients to undergo either computer-navigated or conventional replacement. An improved alignment was seen in the computer-navigated group. The patients were then followed up post-operatively for two years, using the Knee Society score, the Short Form-36 health survey, the Western Ontario and McMaster Universities osteoarthritis index, the Bartlett Patellar pain questionnaire and the Oxford knee score, to assess functional outcome. At two years post-operatively 60 patients were available for assessment, 30 in each group and 62 patients completed a postal survey. No patient in either group had undergone revision. All variables were analysed for differences between the groups either by Student’s t-test or the Mann-Whitney U test. Differences between the two groups did not reach significance for any of the outcome measures at any time point. At two years postoperatively, the frequency of mild to severe anterior pain was not significantly different (p = 0.818), varying between 44% (14) for the computer-navigated group, and 47% (14) for the conventionally-replaced group. The Bartlett Patellar score and the Oxford knee score were also not significantly different (t-test p = 0.161 and p = 0.607, respectively). The clinical outcome of the patients with a computer-navigated knee replacement appears to be no different to that of a more conventional jig-based technique at two years post-operatively, despite the better alignment achieved with computer-navigated surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 434 - 440
1 Apr 2009
Dall GF Ohly NE Ballantyne JA Brenkel IJ

We analysed which pre-operative factors could be used to predict the length of in-patient stay following unilateral primary total hip replacement undertaken for osteoarthritis. Data were collected prospectively from 2302 patients undergoing primary total hip replacement over a nine-year period. The relationships between the various pre-operative factors and length of stay were studied separately using either Student’s t-test or Pearson’s correlation, and then subjected to multiple linear regression analysis. The mean length of stay was 8.1 days (median 7; 3 to 58). After adjusting for the effects of other pre-operative factors, younger age, male gender, higher combined Harris hip function and activity score, higher general health perception dimension of the Short-Form 36 score, and non-steroidal anti-inflammatory drug use were all found to be significantly associated with a reduced length of stay


Bone & Joint Open
Vol. 3, Issue 1 | Pages 77 - 84
24 Jan 2022
Onishi E Ota S Fujita S Tsukamoto Y Yamashita S Hashimura T Matsunaga K Yasuda T

Aims

This study aimed to evaluate sagittal spinopelvic alignment (SSPA) in the early stage of rapidly destructive coxopathy (RDC) compared with hip osteoarthritis (HOA), and to identify risk factors of SSPA for destruction of the femoral head within 12 months after the disease onset.

Methods

This study enrolled 34 RDC patients with joint space narrowing > 2 mm within 12 months after the onset of hip pain and 25 HOA patients showing femoral head destruction. Sharp angle was measured for acetabular coverage evaluation. Femoral head collapse ratio was calculated for assessment of the extent of femoral head collapse by RDC. The following parameters of SSPA were evaluated using the whole spinopelvic radiograph: pelvic tilt (PT), sacral slope (SS), pelvic incidence (PI), sagittal vertical axis (SVA), thoracic kyphosis angle (TK), lumbar lordosis angle (LL), and PI-LL.