Advertisement for orthosearch.org.uk
Results 1 - 20 of 116
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 751 - 758
1 Jul 2024
Yaxier N Zhang Y Song J Ning B

Aims. Given the possible radiation damage and inaccuracy of radiological investigations, particularly in children, ultrasound and superb microvascular imaging (SMI) may offer alternative methods of evaluating new bone formation when limb lengthening is undertaken in paediatric patients. The aim of this study was to assess the use of ultrasound combined with SMI in monitoring new bone formation during limb lengthening in children. Methods. In this retrospective cohort study, ultrasound and radiograph examinations were performed every two weeks in 30 paediatric patients undergoing limb lengthening. Ultrasound was used to monitor new bone formation. The number of vertical vessels and the blood flow resistance index were compared with those from plain radiographs. Results. We categorized the new bone formation into three stages: stage I (early lengthening), in which there was no obvious callus formation on radiographs and ultrasound; stage II (lengthening), in which radiographs showed low-density callus formation with uneven distribution and three sub-stages could be identified on ultrasound: in Ia punctate callus was visible; in IIb there was linear callus formation which was not yet connected and in IIc there was continuous linear callus. In stage III (healing), the bone ends had united, the periosteum was intact, and the callus had disappeared, as confirmed on radiographs, indicating healed bone. A progressive increase in the number of vertical vessels was noted in the early stages, peaking during stages IIb and IIc, followed by a gradual decline (p < 0.001). Delayed healing involved patients with a prolonged stage IIa or those who regressed to stage IIa from stages IIb or IIc during lengthening. Conclusion. We found that the formation of new bone in paediatric patients undergoing limb lengthening could be reliably evaluated using ultrasound when combined with the radiological findings. This combination enabled an improved assessment of the prognosis, and adjustments to the lengthening protocol. While SMI offered additional insights into angiogenesis within the new bone, its role primarily contributed to the understanding of the microvascular environment rather than directly informing adjustments of treatment. Cite this article: Bone Joint J 2024;106-B(7):751–758


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1273 - 1278
1 Nov 2022
Chowdhury JMY Ahmadi M Prior CP Pease F Messner J Foster PAL

Aims. The aim of this retrospective cohort study was to assess and investigate the safety and efficacy of using a distal tibial osteotomy compared to proximal osteotomy for limb lengthening in children. Methods. In this study, there were 59 consecutive tibial lengthening and deformity corrections in 57 children using a circular frame. All were performed or supervised by the senior author between January 2013 and June 2019. A total of 25 who underwent a distal tibial osteotomy were analyzed and compared to a group of 34 who had a standard proximal tibial osteotomy. For each patient, the primary diagnosis, time in frame, complications, and lengthening achieved were recorded. From these data, the frame index was calculated (days/cm) and analyzed. Results. All patients ended their treatment with successful lengthening and deformity correction. The frame index for proximal versus distal osteotomies showed no significant difference, with a mean 48.5 days/cm (30 to 85) and 48.9 days/cm (28 to 81), respectively (p = 0.896). In the proximal osteotomy group, two patients suffered complications (one refracture after frame removal and one failure of regenerate maturation with subsequent valgus deformity) compared to zero in the distal osteotomy group. Two patients in each group sustained obstacles that required intervention (one necessitated guided growth, one fibula lengthening, and two required change of wires). There was a similar number of problems (pin-site infections) in each group. Conclusion. Our data show that distal tibial osteotomies can be safely employed in limb lengthening for children using a circular frame, which has implications in planning a surgical strategy; for example, when treating a tibia with shortening and distal deformity, a second osteotomy for proximal lengthening is not required. Cite this article: Bone Joint J 2022;104-B(11):1273–1278


Bone & Joint Research
Vol. 7, Issue 7 | Pages 476 - 484
1 Jul 2018
Panagiotopoulou VC Davda K Hothi HS Henckel J Cerquiglini A Goodier WD Skinner J Hart A Calder PR

Objectives. The Precice nail is the latest intramedullary lengthening nail with excellent early outcomes. Implant complications have led to modification of the nail design. The aim of this study was to perform a retrieval study of Precice nails following lower-limb lengthening and to assess macroscopical and microscopical changes to the implants and evaluate differences following design modification, with the aim of identifying potential surgical, implant, and patient risk factors. Methods. A total of 15 nails were retrieved from 13 patients following lower-limb lengthening. Macroscopical and microscopical surface damage to the nails were identified. Further analysis included radiology and micro-CT prior to sectioning. The internal mechanism was then analyzed with scanning electron microscopy and energy dispersive x-ray spectroscopy to identify corrosion. Results. Seven male and three female patients underwent 12 femoral lengthenings. Three female patients underwent tibial lengthening. All patients obtained the desired length with no implant failure. Surface degradation was noted on the telescopic part of every nail design, less on the latest implants. Microscopical analysis confirmed fretting and pitting corrosion. Following sectioning, black debris was noted in all implants. The early designs were found to have fractured actuator pins and the pin and bearings showed evidence of corrosive debris. The latest designs showed evidence of biological deposits suggestive of fluid ingress within the nail but no corrosion. Conclusion. This study confirms less internal corrosion following modification, but evidence of titanium debris remains. We recommend no change to current clinical practice. However, potential reuse of the Precice nail, for secondary limb lengthening in the same patient, should be undertaken with caution. Cite this article: V. C. Panagiotopoulou, K. Davda, H. S. Hothi, J. Henckel, A. Cerquiglini, W. D. Goodier, J. Skinner, A. Hart, P. R. Calder. A retrieval analysis of the Precice intramedullary limb lengthening system. Bone Joint Res 2018;7:476–484. DOI: 10.1302/2046-3758.77.BJR-2017-0359.R1


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 130 - 132
1 Jan 1992
Maffulli N Hughes T Fixsen J

Limb lengthening in nine patients was monitored by radiographs and by ultrasound scans. The distraction gap appeared as a sonolucent area within which echogenic foci developed soon after distraction commenced. By seven weeks a new cortex was detected, and medullary canal began to develop between seven and eight weeks. Ultrasound scanning can be used to measure distraction, but it was not as useful as radiographs in detecting angulation. Its use in patients undergoing limb lengthening could reduce their exposure to radiation


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 583 - 587
1 Apr 2005
Szöke G Lee S Simpson AHRW Prescott J

Little is known about the increase in length of tendons in postnatal life or of their response to limb lengthening procedures. A study was carried out in ten young and nine adult rabbits in which the tibia was lengthened by 20% at two rates 0.8 mm/day and 1.6 mm/day. The tendon of the flexor digitorum longus (FDL) muscle showed a significant increase in length in response to lengthening of the tibia. The young rabbits exhibited a significantly higher increase in length in the FDL tendon compared with the adults. There was no difference in the amount of lengthening of the FDL tendon at the different rates. Of the increase in length which occurred, 77% was in the proximal half of the tendon. This investigation demonstrated that tendons have the ability to lengthen during limb distraction. This occurred to a greater extent in the young who showed a higher proliferative response, suggesting that there may be less need for formal tendon lengthening in young children


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1394 - 1399
1 Oct 2009
Oh C Song H Kim J Choi J Min W Park B

Ten patients, who were unsuitable for limb lengthening over an intramedullary nail, underwent lengthening with a submuscular locking plate. Their mean age at operation was 18.5 years (11 to 40). After fixing a locking plate submuscularly on the proximal segment, an external fixator was applied to lengthen the bone after corticotomy. Lengthening was at 1 mm/day and on reaching the target length, three or four screws were placed in the plate in the distal segment and the external fixator was removed. All patients achieved the pre-operative target length at a mean of 4.0 cm (3.2 to 5.5). The mean duration of external fixation was 61.6 days (45 to 113) and the mean external fixation index was 15.1 days/cm (13.2 to 20.5), which was less than one-third of the mean healing index (48 days/cm (41.3 to 55). There were only minor complications. Lengthening with a submuscular locking plate can successfully permit early removal of the fixator with fewer complications and is a useful alternative in children or when nailing is difficult


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 938 - 942
1 Jul 2006
Singh S Lahiri A Iqbal M

Limb lengthening by callus distraction and external fixation has a high rate of complications. We describe our experience using an intramedullary nail (Fitbone) which contains a motorised and programmable sliding mechanism for limb lengthening and bone transport. Between 2001 and 2004 we lengthened 13 femora and 11 tibiae in ten patients (seven men and three women) with a mean age of 32 years (21 to 47) using this nail. The indications for operation were short stature in six patients and developmental or acquired disorders in the rest. The mean lengthening achieved was 40 mm (27 to 60). The mean length of stay in hospital was seven days (5 to 9). The mean healing index was 35 days/cm (18.8 to 70.9). There were no cases of implant-related infection or malunion


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1666 - 1669
1 Dec 2006
Shisha T Kiss S Pap K Simpson H Szöke G

The response of the muscle is critical in determining the functional outcome of limb lengthening. We hypothesised that muscle response would vary with age and therefore studied the response of the muscles during tibial lengthening in ten young and ten mature rabbits. A bromodeoxyuridine technique was used to identify the dividing cells. The young rabbits demonstrated a significantly greater proliferative response to the distraction stimulus than the mature ones. This was particularly pronounced at the myotendinous junction, but was also evident within the muscle belly. Younger muscle adapted better to lengthening, suggesting that in patients in whom a large degree of muscle lengthening is required it may be beneficial to carry out this procedure when they are young, in order to achieve the optimal functional result


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 259 - 265
1 Mar 2004
Saldanha KAN Saleh M Bell MJ Fernandes JA

We performed limb lengthening and correction of deformity of nine long bones of the lower limb in six children (mean age, 14.7 years) with osteogenesis imperfecta (OI). All had femoral lengthening and three also had ipsilateral tibial lengthening. Angular deformities were corrected simultaneously. Five limb segments were treated using a monolateral external fixator and four with the Ilizarov frame. In three children, lengthening was done over previously inserted femoral intramedullary rods. The mean lengthening achieved was 6.26 cm (mean healing index, 33.25 days/cm). Significant complications included one deep infection, one fracture of the femur and one anterior angulation deformity of the tibia. The abnormal bone of OI tolerated the external fixators throughout the period of lengthening without any episodes of migration of wires or pins through the soft bone. The regenerate bone formed within the time which is normally expected in limb-lengthening procedures performed for other conditions. We conclude that despite the abnormal bone characteristics, distraction osteogenesis to correct limb-length discrepancy and angular deformity can be performed safely in children with OI


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 545 - 549
1 Aug 1986
De Bastiani G Aldegheri R Renzi Brivio L Trivella G

We have compared, in rabbits, two techniques of limb lengthening by distraction of the epiphyseal plate using a unilateral external fixation frame. In all cases, 14 mm of symmetrical lengthening without deviation was achieved. With rapid distraction at rates of 1 mm per day (distractional epiphyseolysis) separation of the epiphysis from the metaphysis occurred by day 7, and by day 70 almost complete ossification of the cartilage and the elongated segment was evident. In contrast, slow distraction at 0.25 mm every 12 hours (chondrodiatasis) produced hyperplasia of growth cartilage without any evidence of detachment at 28 days, the end of the distraction period. By day 70 the epiphyseal plate had returned to normal thickness with normal cellular morphology, while the lengthened segment was occupied by ossified tissue. The significance of these findings is discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 121 - 124
1 Jan 1990
Galardi G Comi G Lozza L Marchettini P Novarina M Facchini R Paronzini A

Limb lengthening is used to correct leg length discrepancy and to increase stature. The reported frequency of peripheral nerve complications varies from 5% to 30%, but is probably underestimated. Damage may be direct or be caused by overstretching of the nerves. We have used electrophysiological tests to evaluate five patients during bilateral tibial lengthening by the Ilizarov method. Results after 24 to 107 days of lengthening showed electromyographic evidence of partial muscle denervation in all 10 limbs, with reduced motor conduction velocities in two tibial nerves and three common peroneal nerves. The sensory conduction velocity in the sural nerve was always unchanged. A clear relationship was shown between the amount of tibial lengthening and the degree of electrophysiological abnormality. Our results suggest that subclinical nerve damage is a very frequent complication of tibial lengthening


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 788 - 792
1 Jun 2011
Schiedel FM Pip S Wacker S Pöpping J Tretow H Leidinger B Rödl R

We report the results of intramedullary leg lengthening conducted between 2002 and 2009 using the Intramedullary Skeletal Kinetic Distractor in 69 unilateral lengthenings involving 58 femora and 11 tibiae. We identified difficulties that occurred during the treatment and assessed whether they were specifically due to the implant or independent of it. Paley’s classification for evaluating problems, obstacles and complications with external fixators was adopted, and implant-specific difficulties were continuously noted. There were seven failures requiring premature removal of the device, in four due to nail breakage and three for other reasons, and five unsuccessful outcomes after completion of the lengthening. In all, 116 difficulties were noted in 45 patients, with only 24 having problem-free courses. In addition to the difficulties arising from the use of external fixators, there were almost the same number again of implant-specific difficulties.

Nevertheless, successful femoral lengthening was achieved in 52 of the 58 patients (90%). However, successful tibial lengthening was only achieved in five of 11 patients (45%).


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 146 - 146
1 Jan 1990
Hadlow A Nicol R


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 639 - 643
1 May 2011
Burghardt RD Herzenberg JE Specht SC Paley D

Between October 2001 and September 2009 we lengthened 242 lower-limb segments in 180 patients using the Intramedullary Skeletal Kinetic Distractor (ISKD). Mechanical failure was defined either as breakage of the ISKD or failure of the internal mechanism to activate. Retrieved nails which failed mechanically were examined by the manufacturer for defects. In all, 15 ISKDs in 12 patients (13 limbs) failed mechanically representing an overall failure rate of 6.2%, with fracture of the device occurring in ten of the 15 failures. Two nails in one patient failed to lengthen and had to be replaced. The manufacturer detected an error in the assembly of the nail, which prompted a wide recall. One nail jammed after being forcefully inserted, and two nails failed to lengthen fully. Lengthening was achieved in all 12 patients, although three required a second operation to exchange a defective nail for a new, functioning device.

The ISKD is a complex mechanical device which lengthens by the oscillation of two telescopic sections connected by a threaded rod. The junction between these sections is surrounded by a keyring collar. This keyring collar is the weakest part of the device.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 550 - 556
1 Aug 1986
De Bastiani G Aldegheri R Renzi Brivio L Trivella G

We describe a technique for slow, progressive, symmetrical distraction of the growth plate using a lightweight dynamic axial fixation system. Results are given for the elongation of 40 bony segments in children with limb-length discrepancies and 60 segments in children with achondroplasia or hypochondroplasia. Increases in limb length of up to 36% were obtained in non-achondroplastic and up to 64.5% in achondroplastic patients. There were no nerve or vascular lesions or bony infections and no case required a bone graft. Pin-track complications occurred in only 1.5%.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 178 - 178
1 Jan 1999
MONTGOMERY RJ


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 772 - 776
1 Sep 1998
Cheng JCY Cheung KW Ng BKW

Until recently the accepted treatment of choice for severe type-II fibular hemimelia has been Syme’s or Boyd’s amputation. The alternative of distraction lengthening using the Ilizarov technique is now available.

We report three patients (four limbs) with type-II fibular hemimelia who were treated by the Ilizarov technique and followed up for two to six years. Severe progressive procurvatum and valgus deformity of the tibia and valgus deformity and lateral subluxation of the ankle were found in all four limbs. Multiple additional soft-tissue and bony surgery was necessary. In view of these problems we feel that reappraisal of the indications for lengthening in type-II fibular hemimelia is necessary.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1563 - 1567
1 Nov 2010
Parmaksizoglu F Koprulu AS Unal MB Cansu E

We present the results of 13 patients who suffered severe injuries to the lower leg. Five sustained a traumatic amputation and eight a Gustilo-Anderson type IIIC open fracture. All were treated with debridement, acute shortening and stabilisation of the fracture and vascular reconstruction. Further treatment involved restoration of tibial length by callus distraction through the distal or proximal metaphysis, which was commenced soon after the soft tissues had healed (n = 8) or delayed until union of the fracture (n = 5).

All patients were male with a mean age of 28.4 years (17 to 44), and had sustained injury to the leg only. Chen grade II functional status was achieved in all patients. Although the number of patients treated with each strategy was limited, there was no obvious disadvantage in the early lengthening programme, which was completed more quickly.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 358 - 364
1 May 1993
Eyres K Bell M Kanis J

We studied the quantity and rate of formation of new bone during lengthening of 17 limb segments in 10 patients using dual-energy X-ray absorptiometry (DEXA), ultrasonography and radiography. Whereas new bone was detected by both DEXA and ultrasonography within 1 to 2 weeks of distraction, it was not visible on the radiographs until 4 to 8 weeks. Limb alignment and gap measurement were accurately assessed by DEXA without the need for standard radiographs or scanograms. With ultrasound the distraction gap appeared as an echolucent window which narrowed progressively producing a hyper-reflecting line after which further consolidation could not be assessed. As measured by DEXA the density of the new bone at this stage was approximately 45% of control values and did not represent normal cortication. Whereas ultrasound could be used to identify defects in mineralisation and to determine when to dynamise the fixator system, DEXA could measure the quantity and rate of formation of bone throughout lengthening.


Bone & Joint Research
Vol. 5, Issue 1 | Pages 1 - 10
1 Jan 2016
Burghardt RD Manzotti A Bhave A Paley D Herzenberg JE

Objectives

The purpose of this study was to compare the results and complications of tibial lengthening over an intramedullary nail with treatment using the traditional Ilizarov method.

Methods

In this matched case study, 16 adult patients underwent 19 tibial lengthening over nails (LON) procedures. For the matched case group, 17 patients who underwent 19 Ilizarov tibial lengthenings were retrospectively matched to the LON group.