Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 508 - 515
1 Apr 2017
Haefeli PC Marecek GS Keel MJB Siebenrock KA Tannast M

Aims

The aims of this study were to determine the cumulative ten-year survivorship of hips treated for acetabular fractures using surgical hip dislocation and to identify factors predictive of an unfavourable outcome.

Patients and Methods

We followed up 60 consecutive patients (61 hips; mean age 36.3 years, standard deviation (sd) 15) who underwent open reduction and internal fixation for a displaced fracture of the acetabulum (24 posterior wall, 18 transverse and posterior wall, ten transverse, and nine others) with a mean follow-up of 12.4 years (sd 3).


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 405 - 411
1 Mar 2012
Keel MJB Ecker TM Cullmann JL Bergmann M Bonel HM Büchler L Siebenrock KA Bastian JD

A new anterior intrapelvic approach for the surgical management of displaced acetabular fractures involving predominantly the anterior column and the quadrilateral plate is described. In order to establish five ‘windows’ for instrumentation, the extraperitoneal space is entered along the lateral border of the rectus abdominis muscle. This is the so-called ‘Pararectus’ approach. The feasibility of safe dissection and optimal instrumentation of the pelvis was assessed in five cadavers (ten hemipelves) before implementation in a series of 20 patients with a mean age of 59 years (17 to 90), of whom 17 were male. The clinical evaluation was undertaken between December 2009 and December 2010. The quality of reduction was assessed with post-operative CT scans and the occurrence of intra-operative complications was noted. In cadavers, sufficient extraperitoneal access and safe instrumentation of the pelvis were accomplished. In the patients, there was a statistically significant improvement in the reduction of the fracture (pre- versus post-operative: mean step-off 3.3 mm (sd 2.6) vs 0.1 mm (sd 0.3), p < 0.001; and mean gap 11.5 mm (sd 6.5) vs 0.8 mm (sd 1.3), p < 0.001). Lesions to the peritoneum were noted in two patients and minor vascular damage was noted in a further two patients. Multi-directional screw placement and various plate configurations were feasible in cadavers without significant retraction of soft tissues.

In the treatment of acetabular fractures predominantly involving the anterior column and the quadrilateral plate, the Pararectus approach allowed anatomical restoration with minimal morbidity related to the surgical access.