Objectives. The monitoring of fracture healing is a complex process. Typically, successive radiographs are performed and an emerging calcification of the fracture area is evaluated. The aim of this study was to investigate whether different bone healing patterns can be distinguished using a telemetric instrumented femoral internal plate fixator. Materials and Methods. An electronic telemetric system was developed to assess bone healing mechanically. The system consists of a telemetry module which is applied to an internal locking plate fixator, an external reader device, a sensor for measuring externally applied load and a laptop computer with processing software. By correlation between externally applied load and load measured in the implant, the elasticity of the osteosynthesis is calculated. The elasticity decreases with ongoing consolidation of a fracture or nonunion and is an appropriate parameter for the course of bone healing. At our centre, clinical application has been performed in 56 patients suffering nonunion or fracture of the femur. Results. A total of 39 cases of clinical application were reviewed for this study. In total, four different types of healing curves were observed: fast healing; slow healing; plateau followed by healing; and non-healing. Conclusion. The electronically instrumented
Traditionally, unstable anterior pelvic ring injuries have been stabilised with an external fixator or by internal fixation. Recently, a new percutaneous technique of placement of bilateral supraacetabular polyaxial screws and subcutaneous connecting bar to assemble an “internal fixator” has been described. We present the surgical technique and early clinical results of using this technique in twenty-five consecutive patients with a rotationally unstable pelvic ring injury and no diastasis of the symphysis pubis treated between April 2010 and December 2013. Additional posterior pelvic stabilisation with percutaneous iliosacral screws was used in 23 of these patients. The anterior device was routinely removed after three months. Radiological evidence of union of the anterior pelvic ring was seen in 24 of 25 patients at a minimum 6 month follow-up. Thirteen patients developed sensory deficits in the lateral femoral cutaneous nerve (five bilateral) and only one fully recovered. The anterior pelvic
Introduction: Increasing number of osteoporotic fractures of the femur, especially upper part of the femur creates everyday problem of health services. Treatment of these fractures has been improving markedly during the past 25 years. DHS, gamma nail and some other implants are very useful in everyday surgery. However some of complications still can not be resolved like cut out. Osteoporotic fractures in subtrochanteric area represent even bigger challenging. Diaphyseal fractures are also difficult to be treated. The main problem is quality of osteoporotic bone. Plate with parallel screws doesn’t provide reliable fixation. Intramedulary nails, because of wide channel in distal femur area also don’t provide desirable fixation stability. Material and Method: We analysed results of using of one new device: selfdynamisable
Despite its clinical significance, metaphyseal fracture healing has received little attention in research and experimental models have been limited. In particular it is not known to what extent the mechanical environment plays a role in metaphyseal fracture healing. Recently, a new murine internal fixation plate has been developed to stabilise fractures in the distal femur under highly standardised conditions. Goal of the current study was to modify this design, in order to be able to evaluate the influence of the fixator bending stiffness on metaphyseal fracture healing in mice. Adapting the existing single body design, resulting in low flexibility fixation, two new plates were developed with a decreased bending stiffness of approximately 65% and 45% of the original implant (100%). Pilot experiments were performed on 54 animals, whereas the mice were sacrificed and fracture healing assessed radiologically and biomechanically after 14 and 28 days. MicroCT evaluation confirmed that the osteotomy was created in the trabecular, metaphyseal bone of the distal mouse femora. All bones showed progressive fracture healing over time, with decreased implant stiffness leading to increased periosteal callus formation. These implants represent an important new research tool to study molecular and genetic aspects of metaphyseal fracture healing in mice under standardized mechanical conditions, in order to improve clinical treatment in challenging situations, such as in osteoporotic bone.
This involves a retrograde intramedullary nail with a unique “cruciate” configuration of distal locking bolts which stabilise the fractured condyles in relation to the shaft. The optimal geometrical configuration of the distal locking bolts has been developed using cadaver studies. Following finalisation of the design, mechanical bench testing of the implant and clinical trials have been completed according to a protocol agreed with the UK Medical Devices Agency. So far 36 patients have been treated using the implant which has proved to be effective and easy to use. Much less soft tissue dissection is required than when using conventional blade plates or DHS, or even newer “percutaneous” plating methods.
Following completion of clinical trials, the Medical Devices Agency has granted approval for general use of the implant. It is anticipated that this will greatly facilitate the management of distal femoral fractures particularly those involving intercondylar fracture patterns.
Abstract. Introduction. Intra-articular distal humerus OTA type C fractures are challenging to treat. When osteosynthesis is not feasible one can choose to do a primary arthroplasty of elbow or manage non-operatively. The indications for treatment of this fracture pattern are evolving. Objectives. We present our outcomes and complications when this cohort of patients was managed with either open reduction
Locking plates have led to important changes in bone fracture management, allowing flexible biological fracture fixation based on the principle of an
Since the early nineties clinical experience were gained with locking plates to stabilize long bone fractures. Firstly with a Point Contact Fixator, a device making the step from a conventional plate to an
The paper present our results in application of new method for nonunion treatment of the femoral diaphysis. The
Purpose of the study:. To determine the outcomes of cases converted from an external fixator to an
In recent years, plate osteosynthesis in metaphyseal and diaphyseal long bone fractures has been increasingly applied in a minimally invasive fashion. Several clinical studies describe a beneficial effect of the smaller additional soft tissue damage, resulting in satisfying fracture and soft tissue healing. However, is the surgical soft tissue damage really evidently smaller and the recovery faster?. A trauma model with severe, circumferential soft tissue damage to the distal right thigh and a distal multifragmentary (AO type C) femur fracture was carried out on 24 male sheep. After five days temporary external fixation, an
Introduction: Proximal tibial fractures continue to be problematic for orthopaedic surgeons. Continued problems in their managment include infection, soft tissue problems, failure of fixation and joint stiffness. Combining the concept of “biological plating” and locked
Total hip arthroplasty following pelvic or femoral trauma presents the joint surgeon with challenges not dissimilar to that of revision surgery. Careful preoperative evaluation and planning, and realistic assessment of risks and expectations is necessary. Complex acetabular fractures present the surgeon with a variety of challenges in conversion to total hip replacement (THR). Bone stock is the critical factor in achieving a stable acetabular reconstruction, particularly with regard to the posterior column. In patients who have undergone prior open reduction and internal fixation, routine radiographic examination will often be inconclusive as to the status of healing of fractures due to the presence of metal, and CAT scans will be similarly obfuscated by metal artefact. Therefore, the surgeon must be prepared for the possibility of bone stock deficiency at the time of reconstruction. Subclinical infection following ORIF is possible; all patients should be screened for this possibility with preoperative determination of the ESR and C-reactive protein. If these studies are elevated, aspiration of the hip under x-ray or ultrasound guidance should be considered. At the time of surgery, it is suggested that cultures be obtained prior to the administration of systemic antibiotics, and consideration given to intraoperative frozen section examination of tissue if infection is suspected. Removal of
Aim. Radiologic signs such as radiolucent lines around the implant, hardware fracture or displacement and periosteal reaction have been considered suggestive of implant-associated infection. The goal of this study is to assess the correlation of these signs with confirmed internal fixation-associated infection evaluated in a prospective cohort. Method. We evaluated the radiologic appearance of preoperative standard x-ray images in 421 surgeries performed in 380 patients with
Aim. Unexpected positive infections are distinct entity in prosthetic revision surgery. The prevalence and characteristics of unexpected positive cultures in internal fixation are however less established. The aim of this study was to describe the prevalence and characteristics of unexpected diagnosis of infection in a prospective cohort of revision surgeries following internal fixation. Method. We reviewed the microbiological results following 356 surgeries that included partial or complete removal of internal fixation, performed in 328 patients (54% male, mean age 53 ± 17 years), in which infection was not initially suspected. This prospective study was performed in a large single center for musculoskeletal surgery from 2013–2017. The implants most commonly removed were plate and/or screws (281 cases, 78,9%), followed by intramedullary nails (64 cases, 18,0%). The main indications for surgery were nonunion (89 cases, 25%) and symptomatic hardware (70 cases, 19,7%). All removed implants were sonicated, and tissue cultures were obtained depending on the surgeon's criteria. Diagnosis of infection was established by the presence of 2 or more positive tissue cultures (1 with a highly virulent microorganism), or ≥ 50 colony-forming units found in the sonication fluid. Results. Infection was confirmed in 47 cases (13,2%); diagnosis was obtained with tissue cultures in 5 cases (1,4%), sonication in 14 cases (3,9%) and a combination of both sonication and tissue samples in 28 cases (7,9%). In another 24 cases (6,7%), ≥ 50 CFU of low-virulence microorganisms were isolated in the sonication fluid, but no tissue samples were available to confirm the diagnosis. Low-virulent microorganisms such as Propionibacterium acnes (22 cases / 46,8%) or coagulase-negative Staphycoccci (13 cases, 27,7%) were most commonly isolated. Sonication was key for the diagnosis of 61,7% of unexpected-positive surgeries. Nearly half of the patients received a new implant (internal fixation in 40,4%; arthroplasty in 6,4%), but only 34% of the patients were treated with antibiotics on discharge. Conclusions. Unexpected diagnosis of infection occurs in approximately 13,2% of revision surgeries following internal fixation, most commonly due to low-virulent microorganisms. Sonication was key for the diagnosis of the majority of these infections. The clinical relevance of these infections remains unclear, though the insertion of new implants raises concern. We recommend sonication of all
Introduction. Fracture around the knee can lead to posttraumatic osteoarthritis (PTOA) of the knee. Malunion, malalignment, intra-articular osseous defects, retained
Accurate implant size estimation for internal fixation of long bone fractures can reduce intra-operative errors, operative time and radiation exposure. With the advent of pre-packed sterile implants, the exponential increase in the number of
Femoral periprosthetic fractures are rising in incidence. Their management is complex and carries a high associated mortality. Unlike native hip fractures, there are no guidelines advising on time to theatre in this group. We aim to determine whether delaying surgical intervention influences morbidity or mortality in femoral periprosthetic fractures. We identified all periprosthetic fractures around a hip or knee arthroplasty from our prospectively collated database between 2012 and 2021. Patients were categorized into early or delayed intervention based on time from admission to surgery (early = ≤ 36 hours, delayed > 36 hours). Patient demographics, existing implants, Unified Classification System fracture subtype, acute medical issues on admission, preoperative haemoglobin, blood transfusion requirement, and length of hospital stay were identified for all patients. Complication and mortality rates were compared between groups.Aims
Methods
This study investigated vancomycin-microbubbles (Vm-MBs) and meropenem (Mp)-MBs with ultrasound-targeted microbubble destruction (UTMD) to disrupt biofilms and improve bactericidal efficiency, providing a new and promising strategy for the treatment of device-related infections (DRIs). A film hydration method was used to prepare Vm-MBs and Mp-MBs and examine their characterization. Biofilms of methicillin-resistant Aims
Methods